- Product Information
- Product Usage Instructions
- Foreword
- Technical Support and Assistance
- General Safety Instructions
- Product Overview
- Specifications
- Block Diagram
- Mechanical Dimensions
- Device Setup
- DEVICE CONNECTION
- DISPOSAL AND WARRANTY
- FCC Statement
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Vantron S108 Series Unmanaged Industrial Switches
Product Information
Vantron is a world-leading provider of embedded/IoT products and solutions. The S108 Series Unmanaged Industrial Switches are designed to meet the needs of industrial environments.
Features
- Unmanaged switch for industrial use
- Provides reliable and efficient network connectivity
- Multiple Ethernet jacks for easy device connection
- LED indicators for monitoring network status
Specifications
- Version: 1.2
- Website: www.vantrontech.com
Product Usage Instructions
Introduction
In this chapter, you will find an overview of the product, its features, unpacking instructions, and specifications.
Device Connection
This chapter provides information on how to use the S108 Series Unmanaged Switches and describes a typical connection setup.
Disposal and Warranty
This chapter covers guidelines for proper disposal of the product and information about the warranty.
Revision History
No. | Description | Date |
---|---|---|
V1.0 | First release | Oct. 21, 2022 |
V1.1 | Updated I/O description | Jan. 8, 2023 |
V1.2 | Updated the setup instructions | May 17, 2023 |
Foreword
Thank you for purchasing Vantron Industrial Switch (“the Switch” or “the Product”). S108 series is a combination of four unmanaged switch models, including S108-B, S108-F, S108-R and S108-FR. This manual is largely based on S108-FR for illustration, and therefore some of the functions mentioned here may not be applicable to your product. This manual intends to provide guidance and assistance necessary on setting up, operating and maintaining the Product. Please read this manual and make sure you understand the structure and functionality of the Product before putting it into use.
Intended Users
This manual is intended for:
- Network administrators
- Technical support engineers
- Other users
Copyright
Vantron Technology, Inc. (“Vantron”) reserves all rights of this manual,
including the right to change the content, form, product features, and
specifications contained herein at any time without prior notice. An up-to-
date version of this manual is available at
www.vantrontech.com.
The trademarks in this manual, registered or not, are properties of their
respective owners. Under no circumstances shall any part of this user manual
be copied, reproduced, translated, or sold. This manual is not intended to be
altered or used for other purposes unless otherwise permitted in writing by
Vantron. Vantron reserves the right of all publicly released copies of this
manual.
Disclaimer
While all information contained herein has been carefully checked to assure
its accuracy in technical details and typography, Vantron does not assume any
responsibility resulting from any error or features of this manual, nor from
improper uses of this manual or the software.
It is our practice to change part numbers when published ratings or features
are changed, or when significant structure changes are made. However, some
specifications of the Product may be changed without notice.
Technical Support and Assistance
Should you have any question about the Product that is not covered in this manual, contact your sales representative for solution. Please include the following information in your question:
- Product name and PO number;
- Complete description of the problem;
- Error message you received, if any.
Vantron Technology, Inc.
Address: 48434 Milmont Drive, Fremont, CA 94538 Tel:
650-422-3128
Email: sales@vantrontech.com
Regulatory Information
The Product is designed to comply with:
- CE
- Part 15 of the FCC Rules
- UL
Please refer to Appendix for Regulatory Compliance Statement.
Symbology
This manual uses the following signs to prompt users to pay special attention
to relevant information.
- Caution for latent damage to system or human injury
- Attention to important information or regulations
General Safety Instructions
The Product is supposed be installed by knowledgeable, skilled persons familiar with local and/or international electrical codes and regulations. For your safety and prevention of damage to the Product and other equipment connected to it, please read and observe carefully the following safety instructions prior to installation and operation. Keep this manual well for future reference.
- Do not disassemble or otherwise modify the Product. Such action may cause heat generation, ignition, electronic shock, or other damages including human injury, and may void your warranty.
- Keep the Product away from heat source, such as heater, heat dissipater, or engine casing.
- Do not insert foreign materials into any opening of the Product as it may cause the Product to malfunction or burn out.
- To ensure proper functioning and prevent overheating of the Product, do not cover or block the ventilation holes of the Product.
- Follow the installation instructions with the installation tools provided or recommended.
- The use or placement of the operation tools shall comply with the code of practice of such tools to avoid short circuit of the Product.
- Cut off the power before inspection of the Product to avoid human injury or product damage.
Precautions for Power Cables and Accessories
- Use proper power source only. The Product supports 5V-36V power supply. Make sure the supply voltage falls within the specified range.
- Place the cables properly at places without extrusion hazards.
- Use only approved antenna(s). Non-approved antenna(s) may produce spurious or excessive RF transmitting power which may violate FCC limits.
Cleaning instructions:
- Power off the Product before cleaning
- Do not use spray detergent
- Clean with a damp cloth
- Do not try to clean exposed electronic components unless with a dust collector
Power off and contact Vantron technical support engineer in case of the following faults:
- The Product is damaged
- The temperature is excessively high
- Fault is still not solved after troubleshooting according to this manual
Do not use in combustible and explosive environment:
- Keep away from combustible and explosive environment
- Keep away from all energized circuits
- Unauthorized removal of the enclosure from the Product is not allowed
- Do not change components unless the power cable is unplugged
- In some cases, the Product may still have residual voltage even if the power cable is unplugged. Therefore, it is a must to remove and fully discharge the Product before replacement of the components.
Product Overview
- As part of Vantron’s overall solution for industrial automation, Vantron S108 series is a collection of four unmanaged industrial switches that feature 8 Gigabit Ethernet ports to demonstrate excellent data transfer performance.
- Vantron S108 series offers a Plug and Play solution that reduces users’ educational inputs and its compact size helps to save the user space. This series supports 12V~48V wide input voltage and -20℃ ~ +70℃ industrial-grade extended temperature range, and implements a fanless heat sink for device heat dissipation. Customers have the option of DIN-rail mounting or rack mounting depending on their installation environment.
- Switches are usually used in harsh environments that require stable operation and involve data interaction between a range of devices. Vantron S108 series is particularly designed for rail transit, smart city, intelligent mining, etc.
Features
Unpacking
The Product has been carefully packed with special attention to quality.
However, should you find anything damaged or missing, please contact your
sales representative in due time.
Actual accessories might vary slightly from the list above as the customer
order might differ from the standard configuration options.
Specifications
Model Name | S108-B | S108-F | S108-R | S108-FR |
---|
Ethernet
| ****
Interface
| 8 x RJ45, 10/100/1000 Base-T (X)
NA| 2 x SFP, 1000M| NA| 2 x SFP, 1000M
LED Indicator
| 2 x LED indicator on each RJ45 port
(Green: Link/Activity; Yellow: ON—1000M, OFF—10/100M) 2 x LED indicator for each SFP port (NA for S108-B/S108-R)
Standard| IEEE802.3, IEEE802.3u, IEEE802.3x, IEEE802.3z
Data Transfer
| Forwarding mode| Store-and-forward
MAC address table| 4K
Switching capability| 16Gbps
Packet forwarding
rate
| ****
11.9Mpp
Packet buffer| 2.5Mb
System Control
| Alarm relay| NA| 1 x 2-pin x 5.0mm (Current load: 1A @24VDC)
LED indicator
| 1 x Power indicator 1 x Status indicator 1 x Error indicator
Mechanical
| Dimensions| 170mm x 122mm x 50mm
Installation| DIN-rail mounting
MTBF| ≥30,000 H
IP rating| IP40
Power
| ****
Input
| 12V~48V DC, 1 x 4-pin x 5.0mm terminal block
(Dual redundant power supply, Over-current protection, Reverse polarity protection)
Consumption| <3W (Idle); < 7.5W (Full load)
Environment Condition
| Temperature| Operating: -20℃ ~ +70℃; Storage: -40℃ ~ +85℃
Humidity| Operating: RH 0-90% (Non-condensing)
EMC level| > EMC Level 3
Certification| CE, FCC, UL
Test Standard
| ****
Industrial Standard
| EMI
FCC CFR47 Part 15, EN55032/CISPR22, Class A EMS
IEC61000-4-2 (ESD): ±6kV (contact), ±8kV (air) IEC61000-4-3 (RS): 10V/m (80MHz~2GHz)
IEC61000-4-4 (EFT): Power port: ±2kV, Data port: ±1kV
IEC61000-4-5 (Surge): Power port: ±1kV/DM, ±2kV/CM, Data port: ±1kV/DM, ±2kV/CM IEC61000-4-6 (CS): 10V (150kHz~80MHz) (Mechanical)
IEC60068-2-6 (Vibration) IEC60068-2-27 (Shock)
IEC60068-2-32 (Free fall)
Block Diagram
Product Layout
Front View
Back View
Left side view
Mechanical Dimensions
170mm x 122mm x 50mm
Power Supply and Consumption
S108 series industrial switches work with 12V-48V DC power input supplied by a
DC connector that supports dual redundant power supply, and is reinforced by
over-current protection, reverse polarity protection. The power consumption of
the device is less than 3W when idled and less than 7.5W with full load.
Device Setup
Before using the switch, please follow the steps below to finish the device installation.
- Hold the switch uprightly
- Place the switch on the DIN rail at an angle with the clip at the top of the DIN rail bracket fit into one side of the DIN rail;
- Push the switch down to compress the spring of the bracket;
- Release the switch when there is enough space for the downside of the DIN rail bracket to fit the other side of the DIN rail
- Gently swing the switch to make sure the switch is fastened on the DIN rail;
- Insert one end of an Ethernet cable into any RJ45 port of the switch and the other end into a switch or server to connect the switch to the network;
- Use another Ethernet cable to connect a client device to another RJ45 port of the switch when necessary;
- Insert the terminal end of the DC power connector into the power terminal of the switch and the other end into the power cord;
- Plug the power adapter into a power outlet that meets the supply voltage requirement (12V to 48V DC) to turn on the device.
Starting the Device
S108 series unmanaged industrial switches offer a plug-and-play solution, and
users need only to connect the switch to a power source to start using the
device. There is no requirement for additional configurations
I/Os
Power connector
The switch implements a 4-pin 5.0mm power connector that supports dual
redundant power supply with over-current protection and reverse polarity
protection to ensure reliable operation of the device in a long term
Pin | Signal | Description |
---|---|---|
1 | V1+ | Primary power supply positive |
2 | V1- | Primary power supply negative |
3 | V2+ | Backup power positive |
4 | V2- | Backup power negative |
Relay
S108-R and S108-FR implement a relay connector that is designed to connect an
alarm to alert the user when there is a fault with any of the interface. The
connector supports a load capacity of 1A @24V DC.
Pin | Signal | Description |
---|---|---|
1 | Relay_in | Relay input |
2 | Relay_out | Relay output |
Grounding screw hole
With the grounding screw hole, users can ground the switch using an M3 screw
and a grounding wire
Reset button
The switch implements a pinhole reset button which enables the device to
reboot upon a short press.
Ethernet jacks
The switch offers eight RJ45 Ethernet jacks, supporting 10M/100M/1000M Base-T
data rate.
S108-F and S108-FR additionally implement two SFP ports, including SFP1
(marked as G9 on the enclosure) that supports 100M/1G data rate and SFP2 (G10)
that supports 100M/1G/2.5G auto adaptive data rate
Each Ethernet jack has two LED indicators to indicate the link/activity status
of the network. Description of the status indicator is detailed in the
following section.
Definition of LED Indicators
Definition of the three LED indicators that indicate the status of the switch is shown below.
LED Indicator | Description |
---|---|
PWR | Lights up when power is on |
RUN | Blinks slowly when the system functions properly |
FAULT | Lights up in the event of device malfunction, hardware error, etc. |
Link/activity indicator of RJ45 jacks
Each RJ45 jack (G1-G8) is provided with two LED indicators to indicate the
link/activity status of the network.
Definition of the each set of indicators is as follows
LED Indicator | Description |
---|
Link
| Off: 10/100M data rate
Solid green: 1000M data rate
Activity
| Off: link down
Solid green: link up
Blinking: data transferring
For S108-F and S108-FR, the two sets of LED indicators for the two SFP ports (G9-G10) are next to the device status LED indicators with separate screen printings.
Definition of the each set of indicators is as follows:
LED Indicator | Description |
---|
Link
| Off: link down
Solid green: link up
Activity
| Off: link down
Solid amber: link up
Blinking: data transferring
DEVICE CONNECTION
Usage of S108 Series Unmanaged Industrial Switches
- S108 series unmanaged industrial switches are plug-and-play devices that requires no complex setup. Such switches are typically used in smaller networks or to connect certain workgroups to a higher-level network without remote configuration, management, or monitoring options.
- The switches are suitable for any business network that wants to simplify the installation of wireless access points and IP-based surveillance cameras.
- Switches are usually used in harsh environments that require stable operation and involve data interaction between a range of devices. Vantron S108 series is particularly designed for rail transit, smart city, intelligent mining, etc
Typical Connection
The following is a simple connection topology of S108-FR in the application of
traffic surveillance.
DISPOSAL AND WARRANTY
Disposal
- When the device comes to end of life, you are suggested to properly dispose of the device for the sake of the environment and safety.
- Before you dispose of the device, please back up your data and erase it from the device.
- It is recommended that the device is disassembled before disposal in conformity with local regulations. Please ensure that the abandoned batteries are disposed of according to local regulations on waste disposal. Do not throw batteries into fire or put in a common waste canister as they are explosive. Products or product packages labeled with the
- sign of “explosive” should not be disposed of like household waste but delivered to specialized electrical & electronic waste recycling/disposal centers.
- Proper disposal of this sort of waste helps avoid harm and adverse effect on surroundings and people’s health. Please contact local organizations or recycling/disposal centers for more recycling/disposal methods of related products.
Product Warranty
VANTRON warrants to its CUSTOMER that the Product manufactured by VANTRON, or its subcontractors will conform strictly to the mutually agreed specifications and be free from defects in workmanship and materials (except that which is furnished by the CUSTOMER) upon shipment from VANTRON. VANTRON’s obligation under this warranty is limited to replacing or repairing, at its option, of the Product which shall, within 24 months after shipment, effective from invoice date, be returned to VANTRON’s factory with transportation fee paid by the CUSTOMER and which shall, after examination, be disclosed to VANTRON’s reasonable satisfaction to be thus defective. VANTRON shall bear the transportation fee for the shipment of the Product to the CUSTOMER
Out-of-Warranty Repair
VANTRON will furnish the repair services for the Product which are out-of-
warranty at VANTRON’s then-prevailing rates for such services. At the
customer’s request, VANTRON will provide components to the CUSTOMER for non-
warranty repair. VANTRON will provide this service as long as the components
are available in the market; and the CUSTOMER is requested to place a purchase
order upfront. Parts repaired will have an extended warranty of 3 months.
Returned Products
Any Product found to be defective and covered under warranty under Clause above shall be returned to VANTRON only upon the CUSTOMER’s receipt of and concerning a VANTRON-supplied Returned Materials Authorization (RMA) number. VANTRON shall supply an RMA, when required within three (3) working days of request by the CUSTOMER. VANTRON shall submit a new invoice to the CUSTOMER upon shipping of the returned products. Before the return of any products by the CUSTOMER due to rejection or warranty defect, the CUSTOMER shall afford VANTRON the opportunity to inspect such products at the CUSTOMER’s location and no Product so inspected shall be returned to VANTRON unless the cause for the rejection or defect is determined to be the responsibility of VANTRON. VANTRON shall in turn provide the CUSTOMER turnaround shipment on defective Product within fourteen (14) working days upon its receipt at VANTRON. If such turnaround cannot be provided by VANTRON due to causes beyond the control of VANTRON, VANTRON shall document such instances and notify the CUSTOMER immediately.
FCC Statement
This equipment has been tested and found to comply with the limits for a Class
A digital device, under part 15 of FCC Rules. These limits are designed to
provide reasonable protection against harmful interference in a commercial
environment. This equipment generates and can radiate radio frequency energy
and, if not installed and used in accordance with the instructions, may cause
harmful interference to radio communications. However, there is no guarantee
that interference will not occur in a particular installation. If this
equipment does cause harmful interference to radio or television reception,
which can be determined by turning the equipment off and on, the user is
encouraged to try to correct the interference by one or more of the following
measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and the receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
This device complies with Part 15 of FCC Rules. Operation is subject to the
following two conditions: (1) This device may not cause harmful interference,
and (2) This device must accept any interference received, including
interference that may cause undesired operation.
Note: The manufacturer is not responsible for any radio or TV interference
caused by unauthorized modifications to this equipment. Such modifications
could void the user’s authority to operate this equipment.
S108 Series Industrial Switches
www.vantrontech.com