  • This product is a fixture that requires installation. It comes with various components including a mounting strap, outlet box, strap mounting screws, mounting screws, socket, long countersunk screw, canopy, frame, and short countersunk screws.
  • The fixture is designed to be installed with the sockets facing up.
  • For warranty information, please visit kichler.com/warranty.

Product Usage Instructions

  1. Remove two (2) short countersunk screws [G] from cover [H] (one on each side of cover). Remove one (1) long countersunk screw [I] from cover [H]. Carefully remove the cover from the frame [J]. Retain countersunk screws.
  2. Attach the mounting strap [A] to the outlet box [B] using the strap mounting screws [C]. The mounting strap can be adjusted to suit the position of the fixture. Ensure that the bent tabs at the outer edge of the mounting strap are pointing away from the wall at the 9 and 3 o’clock positions as shown in the illustration.
  3. Grounding instructions:
    • If the mounting strap is provided with a hole and two raised dimples, wrap the ground wire from the outlet box around the green ground screw and thread it into the hole.
    • If a cupped washer is provided, attach the ground wire from the outlet box under the cupped washer and green ground screw, and thread it into the mounting strap.

If the fixture is provided with a ground wire, connect it to the outlet box ground wire using a wire connector after following the above steps. Never connect the ground wire to the black or white power supply wires.

  1. Make wire connections according to the reference chart below:
    Connect Black or Red Supply Wire to:| Connect White Supply Wire to:
    ---|---
    Black| White
    Clear, Brown, Gold or Black without Tracer| Clear, Brown, Gold or Black with Tracer
    Insulated wire (other than green) with copper conductor| Insulated wire (other than green) with silver conductor

Note: When parallel wire (SPT 1 & SPT 2) is used, the neutral wire is square shaped or ridged and the other wire will be round in shape or smooth (See illustration).

  1. Push the canopy [F] to the wall, carefully aligning the mounting screw holes in the left and right sides of the mounting strap with the mounting screw holes in the left and right sides of the canopy. Make sure all wires are inside the canopy and do not get pinched between the mounting strap and canopy or wall and canopy of the fixture.
  2. Screw two (2) mounting screws [D] into the holes in the canopy and mounting strap to attach the fixture to the wall. One on the left side and one on the right side of the canopy. Tighten to secure.
  3. Insert recommended bulb(s) (not included).
  4. Attach cover [H] to frame [J] using the one (1) long countersunk screw [I] and the two (2) short countersunk screws [G] that were removed in Step 1. Tighten to secure.

FIXTURE DIAGRAM

KICHLER-59132BKT-Kroft-Two-Light-Outdoor-Wall-Mount-
FIG-1

PARTS LIST

  • [A] Mounting Strap
  • [B] Outlet Box (not supplied)
  • [C] Strap Mounting Screw (2)
  • [D] Mounting Screw (2)
  • [E] Socket
  • [F] Canopy
  • [G] Short Countersunk Screw (2)
  • [H] Cover
  • [I] Long Countersunk Screw
  • [J] Frame

CAUTION – RISK OF SHOCK:
Disconnect Power at the main circuit breaker panel or main fusebox before starting and during the installation.
WARNING

  1. This fixture is intended for installation in accordance with the National Electrical Code (NEC) and all local code specifications. If you are not familiar with code requirements, installation by a certified electrician is recommended. Failure to adhere to these codes and instructions may result in serious injury and/or property damage and will void the warranty.

INSTRUCTIONS FOR MOUNTING FIXTURES OUTDOORS AND/OR IN WET LOCATIONS

  1. The mounting surface should be clean, dry, flat, and 1/4” larger than the canopy on all sides. Any gaps between the mounting surface and canopy exceeding 3/16” should be corrected as required.
  2. With silicone caulking compound, caulk completely around where the back of the canopy meets the wall surface to prevent water from seeping into the outlet box.

CLEANING

  • Always be certain that the electric current is turned off before cleaning.
  • Only a soft damp cloth should be used. Harsh cleaning products may damage the finish.

INSTALLATION INSTRUCTIONS

  1. Remove two (2) short countersunk screws [G] from cover [H] (one on each side of cover). Remove one (1) long countersunk screw [I] from cover [H]. Carefully remove the cover from the frame [J]. Retain countersunk screws.

  2. Attach the mounting strap [A] to the outlet box [B] using the strap mounting screws [C]. The mounting strap can be adjusted to suit the position of the fixture.
    NOTE: The mounting strap should be installed with the bent tabs at the outer edge of the mounting strap pointing away from the wall, at the 9 and 3 o’clock position as shown.

  3. Grounding instructions: (See Illus. a or b).

    • On fixtures where the mounting strap is provided with a hole and two raised dimples, wrap ground wire from the outlet box around the green ground screw, and thread into the hole.
    • On fixtures where a cupped washer is provided, attach the ground wire from the outlet box under the cupped washer and green ground screw, and thread it into the mounting strap.
      If the fixture is provided with ground wire, connect the fixture ground wire to the outlet box ground wire with a wire connector after following the above steps. Never connect ground wire to black or white power supply wires .KICHLER-59132BKT-Kroft-Two-Light-Outdoor-Wall-Mount-
FIG-2
  4. Make wire connections. Reference the chart below for correct connections and wire accordingly.
    Connect Black or Red Supply Wire to:| Connect White Supply Wire to:
    ---|---
    Black| White
    Parallel cord (round & smooth)| Parallel cord (square & ridged)
    Clear, Brown, Gold or Black without Tracer| Clear, Brown, Gold or Black with Tracer
    Insulated wire (other than green) with copper conductor| Insulated wire (other than green) with silver conductor
    Note: When parallel wire (SPT 1 & SPT 2) is used. The neutral wire is square shaped or ridged and the other wire will be round in shape or smooth (See illus.)|

  5. NOTE: Fixture should be installed with sockets[E] facing UP.
    Push canopy [F] to the wall, carefully aligning the mounting screw holes on left and right side of the mounting strap with the mounting screw holes in the left and right side of the canopy.
    NOTE: Make sure all wires are inside the canopy and do not get pinched between the mounting strap and canopy or wall and canopy of the fixture.

  6. Screw two (2) mounting screws [D] into holes in the canopy and mounting strap to attach the fixture to the wall. One on the left side and one on the right side of the canopy. Tighten to secure.

  7. Insert recommended bulb(s) (not included).

  8. Attach cover [H] to frame [J] using the one (1) long countersunk screw [I] and the two (2) short countersunk screws [G] that were removed in Step 1. Tighten to secure.