Single column controller instruction manual
Function introduction
Intelligent single column controller has the following characteristics:
- It can control two motors` output to achieve synchronous operation;
- Showing the operating height every time;
- Four-phase position setting and outage memoty;
- It will rebound when meeting resistance.
System parameters
- Input voltage:DC29V;
- Input current: recommending above 1.8A and according to the load;
- Maximum output voltage of motor interface:DC29V;
- Maximum output current of motor interface:4A;
- Operating temperature:0~40℃
- Working humidity:20~90%;
- Storage temperature:20~70℃.
System connection
- Handheld controller
- Main controller
- telecontroller
- Non-part of the system
Motor interfase plug definition
Motor power:+(-) 0~29VDC Motor power:(+)-
Hall switch:2ch
Hall switch:GND
Hall switch: 1ch 5VDC
Hall switch:Vcc
Fault code and its treatment
- Fault code Err1 When the manual controller shows Er1,it`s a foult of Err1.It meas there is something wrong with M1 interface channel (see the following picture).For exemple ,motors are not connected in a positive way;Hall signal boar is not connected; Paper line,etc.
After the problem is eliminated, presing the″ down button″ more than 3 secnds to eliminate the fault, and the machine retuns to the reset state.
System reset
-
Prompt reset
When the manual controller shows ″RST″(see the following picture),the whole system needs to reset maunally. -
Line reset
When the manual controller shows the minimum heigh(for example,for a system with a reset height of 60cm,see the following picture),pressing″down button″ more than 5 seconds. When the manual controller shows RST,releasing the hand and starting to reset system. -
Reset method
When the manual controller shows ″RST″(see the following figure),pressing the ″down button″ and don`t let go. Column began to shorten.the speed could be slow.Observing other damages during operation,if so,let go.
The colunm will rise5~10mm after a short time when it reach the lowest point.
After all arrive,rising a small distance.
When the manual controller ″RST″disapper(see the following picture),releasing
the hand and end at resetting.
Preset the target height
-
The number of presetting target height:
The system provide 4 sets of target height,all of them can be saved more than 10 years. -
Initial preset target height:
The 4 sets of target height ,all of which are the minimum height before manually preset other parameters. -
Daleting the date of target height:
The system does not set the erase function separately.Setting the new paremeter of the target height ,the old one will be automatically erased. -
The way of presetting target height:
At any height(reset state,wrong state unable to perform this operation),can set the paremeter into 1~4 keys.
For example:Set the curren height of 97 to key 2 Press ″S″ to display ″SET″
In 2 seconds,pressing 2 before ″SET″ disappears Displaying ″S-2″means setting over. -
The way of using target height:
At any height(reset state,wrong state unable to perform this operation),can quickly reache for the target height by 1~4 keys.
The way to change height
-
Colunm elongation
-
Operating by Handheld controller :Using″up button″ to achieve longation operation,stopping when travel limit.Releasing hand is the order to stop but not quickly.It stops after a short distance.
-
Operating by telecontroller :Using″up button″ to achieve longation operation,stopping when travel limit.Releasing hand is not the order to stop,passing any key again will stop,but not quickly.It stops after a short distance.
-
Colunm shortening
-
Operating by Handheld controller Using″down button″ to achieve shorten operation,stopping when travel limit.Releasing hand is the order to stop but not quickly.It stops after a short distance.
-
Operating by telecontroller :Using″ down button″ to achieve longation operation, stopping when travel limit.Releasing hand is not the order to stop,passing any key again will stop, but not quickly. It stops after a short distance.
Telecontroller operation
-
Matching window period
Matching window period is repowering after 3 seconds. There will be buzzing sound when the period stop. -
Right code
In matching window period, passing the ″up button″ longly and waiting for 4 long and 3 short intervals of buzzing sound,it means righting code is over. -
Slow rise and fall
In all modes,the motor starts and stops in a new speed change mode, named slow rise and fall,to avoid large impact for desktop when starting and stopping. -
Backtracking when encountering obstacles
In addation to the reset state,when working ,the mechanical structure encounter a sudden changes from loading ,which will cause the contrller to carry out a fallback operation to prevent external sound of injury.
P:When resetting,please pay special attention to whether there are people or objects under the table that may cause harm.