ENGINEERED SYSTEMS 4AC17L Split System Air Conditioner Up To 17 Seer Owner’s Manual
- June 9, 2024
- ENGINEERED SYSTEMS
Table of Contents
ENGINEERED SYSTEMS 4AC17L Split System Air Conditioner Up To 17 Seer
COMPRESSOR
- High-efficiency scroll compressor
- R410A refrigerant
- Internally protected against high temperature motor overload conditions
- Heavy-duty compressor sound blanket for quiet operation (optional accessory)
CABINET
- Full metal louvered construction to protect the coil/hail protection
- Individual louver panels; 4 screws to remove for ease of coil cleaning and service
- Corner-mounted controls for easy service
- Baked polyester paint finished over galvanized steel for maximum durability
- 45-degree offset valves for easy service
COILS
- Omni guard ™ total corrosion protection technology designed coil
- Enhanced tube-and-fin coil design featuring MHT™ Technology
- Lanced fins for maximum heat transfer
- Every coil factory tested for leakproof construction
- Raised coil prevents debris from impeding airflow
COMPONENTS
- Factory installed high and low pressure switches
- Thread-on pressure switches with Schrader core for simple, quick replacement
- Filter drier shipped loose for installation flexibility
- Fan orifice for smoother airflow and sound level reduction
- Charged for 15 feet of line set
WARRANTY
10 year limited warranty on compressor
10 year limited warranty on all parts, extended warranty available*
*Warranty provides for a total of 10 years of limited warranty coverage (Standard 5-year limited parts warranty plus an additional 5-year limited extended parts warranty). Warranty must be registered online within 60 days of installation to qualify for 10-year coverage. Unregistered equipment defaults to 5-year coverage. See full warranty at www.alliedair.com for terms, conditions and exclusions.
NOTE:
For the latest ratings, please see
www.alliedratings.com or
www.AHRIdirectory.org
MODEL NUMBER GUIDE
PHYSICAL AND ELECTRICAL DATA
Model
| Voltage/Hz/Phase| Voltage Range| Min. Circuit Amp.| Max.
Over Current Device (amps)| Compressor| Outdoor Fan Motor
---|---|---|---|---|---|---
Rated Load (amps)| Locked Rotor (amps)| Rated Load (amps)|
Rated HP|
Nom. RPM
4AC17L18P
| 208-230/60/1| 197-253| 12.0| 15| 8.8| 42.6| 1.0| 1/6| 825
4AC17L24P| 208-230/60/1| 197-253| 15.4| 20| 11.7| 59.5| 0.7| 1/8|
1075
4AC17L30P
| 208-230/60/1| 197-253| 18.4| 25| 14.1| 71.3| 0.7| 1/8| 1075
4AC17L36P| 208-230/60/1| 197-253| 17.4| 30| 13.1| 83.1| 1.0| 1/6|
825
4AC17L41P
| 208-230/60/1| 197-253| 21.9| 35| 15.4| 92.1| 2.6| 1/3| 825
4AC17L42P| 208-230/60/1| 197-253| 24.6| 35| 18.6| 110.0| 1.4| 1/4|
825
4AC17L47P
| 208-230/60/1| 197-253| 27.5| 35| 19.9| 110.0| 2.6| 1/3| 825
4AC17L48P| 208-230/60/1| 197-253| 33.0| 50| 25.0| 120.0| 1.7| 1/4|
825
4AC17L59P
| 208-230/60/1| 197-253| 35.5| 50| 26.3| 140.6| 2.6| 1/3| 825
4AC17L60P| 208-230/60/1| 197-253| 31.3| 50| 23.9| 124.5| 1.4| 1/4|
825
UNIT DIMENSIONS (IN.)
Model
| Dimensions (inch)| Shipping Weight (Lbs.)
---|---|---
A – Width| B – Depth|
C – Height
4AC17L18P
| 28.25| 28.25| 29.25| 155
4AC17L24P| 28.25| 28.25| 37.25|
170
4AC17L30P
| 28.25| 28.25| 29.25| 180
4AC17L36P| 28.25| 28.25| 37.25|
200
4AC17L41P
| 32.25| 32.25| 33.25| 225
4AC17L42P| 32.25| 32.25| 33.25|
225
4AC17L47P
| 32.25| 32.25| 33.25| 225
4AC17L48P| 28.25| 28.25| 43.25|
230
4AC17L59P
| 32.25| 32.25| 43.25| 260
4AC17L60P| 32.25| 32.25| 43.25|
260
SOUND RATINGS
Model
| Sound Power1| Estimated Sound Pressure (dBA)2
---|---|---
Approximate Distance3
3.3 Feet (1 Meter)| 6.6 Feet (2 Meters)|
9.8 Feet (3 Meters)
4AC17L18P
| 73| 65| 59| 55
4AC17L24P| 75| 67| 61|
57
4AC17L30P
| 76| 68| 62| 58
4AC17L36P| 76| 68| 62|
58
4AC17L41P
| 75| 67| 61| 57
4AC17L42P| 76| 68| 62|
58
4AC17L47P
| 76| 68| 62| 58
4AC17L48P| 78| 70| 64|
60
4AC17L59P
| 78| 70| 64| 60
4AC17L60P| 80| 72| 66|
62
- Rated in accordance with AHRI standard 270 (2015). AHRI Standard 270 establishes a method of rating outdoor unitary equipment in terms of Sound Power.
- Rated in accordance with AHRI standard 275 (2018). AHRI Standard 275 provides the calculations for estimating the A-Weighted Sound Pressure at a given distance from the equipment. That is a more useful number because that is what humans will hear.
- Based only on distance factor; other factors may change this value such as:
- Unit location (reflective surfaces adjacent to the unit)
- Barrier shielding sources
- Sound path/elevation
- Outside noise sources
ACCESSORIES
System Accessory | Where Used | Kit Number | Purpose |
---|---|---|---|
Liquid Line Solenoid | All models | 60M52 | Prevents liquid migration to the |
compressor especially for high liquid riser applications
Low Ambient (cooling operation)| All models| 34M72| Enables cooling demand
down to 30 °F. Will require freeze stat, CC heater and TXV
Compressor Short Cycle Protector| All models| 47J27| Delays compressor start
5-7 minutes to prevent short cycling
Hard Start| Copeland| 10J42| Scroll compressors usually do not require hard
start; maybe needed for utility brown-out or low voltage areas
LG| 88M91
Crankcase Heater| 18, 24, 30, 36, 42| 93M04| Prevents liquid migration to
compressor in cold weather
41, 47, 48, 59, 60| Factory Installed
Sound Cover| 18, 24, 30, 36, 41| 14W00| Lowers compressor sound level
42, 47, 48, 59, 60| 14W01
Additional System Accessories (indoor section)
TXV Kit| 18, 24, 30| H4TXV01| TXVs provide superior refrigerant flow control,
comfort and efficiency compared to pistons
36, 41, 42, 47, 48| H4TXV02
59, 60| H4TXV03
Outdoor Thermostat – Electric Heat| All models| 10Z23| Prevents electric heat
operation above specific ambient conditions
Outdoor Thermostat – Mounting Box| All models| 31461| Mounting box for outdoor
thermostat
Freezestat| All models| 93G35| Protects the compressor at low suction pressure
conditions
Overflow Switch| All models| 11U75| Turn the system off, if condensate water
overflows due to clogged drain pipes
Blower Time Delay| All models| 58M81| Improves system efficiency and comfort
Single Point Power Supply| All models| 21H39| Provide single power source in
one junction box
Auxiliary Blower Relay| All models| 85W66| Maybe required to select multiple
indoor blower speeds
REFRIGERATION DATA
Model| **Refrig. Charge (oz.) *| Piston Size| TXV|
Refrigerant Line Size| Outdoor Unit Connection| Indoor Unit
Connection
---|---|---|---|---|---|---
Suction| Liquid| Suction| Liquid| Suction|
Liquid**
4AC17L18P
| 72| 0.051| H4TXV01| 3/4| 3/8| 3/4| 3/8| 3/4| 3/8
4AC17L24P| 82| 0.059| H4TXV01| 3/4| 3/8| 3/4| 3/8| 3/4|
3/8
4AC17L30P
| 104| 0.067| H4TXV01| 3/4| 3/8| 3/4| 3/8| 3/4| 3/8
4AC17L36P| 136| 0.072| H4TXV02| 7/8| 3/8| 7/8| 3/8| 7/8|
3/8
4AC17L41P
| 140| N/A| H4TXV02| 7/8| 3/8| 7/8| 3/8| 7/8| 3/8
4AC17L42P| 146| 0.081| H4TXV02| 7/8| 3/8| 7/8| 3/8| 7/8|
3/8
4AC17L47P
| 157| N/A| H4TXV02| 7/8| 3/8| 7/8| 3/8| 7/8| 3/8
4AC17L48P| 152| 0.084| H4TXV02| 7/8| 3/8| 7/8| 3/8| 7/8|
3/8
4AC17L59P
| 190| N/A| H4TXV03| 1-1/8| 3/8| 1-1/8| 3/8| 7/8| 3/8
4AC17L60P| 200| 0.092| H4TXV03| 1-1/8| 3/8| 1-1/8| 3/8| 7/8|
3/8
*Factory charged for 15 feet of line set
** Adapter shipped with unit
† TXV only
COOLING PERFORMANCE WITH DTC1
Outdoor Model
| Indoor Model| Capacity (BTUH)| EER2| SEER2
---|---|---|---|---
4AC17L18P| EAC4X24B| 17600| 11.7|
14.3
4AC17L24P
| EAC4X30B| 23200| 11.7| 14.3
4AC17L30P| EAC4X30B| 28600| 11.7|
14.3
4AC17L36P
| EAC4X36B| 34200| 11.7| 14.3
4AC17L41P| EAC4X49C| 40500| 12.2|
14.8
4AC17L42P
| EAC4X49C| 41500| 11.7| 14.3
4AC17L47P| EAC4X60C| 45500| 11.7|
14.3
4AC17L48P
| EAC4X60C| 47000| 11.2| 13.8
4AC17L59P| EAC4X60C| 55000| 11.7|
14.3
4AC17L60P
| EAC4X60C| 57000| 11.2|
13.8
1 DTC = Designated Tested Combination
NOTE:
For the latest AHRI system matches please visit
www.alliedratings.com or
www.AHRIdirectory.org
Customer Support
1-800-448-5872
All specifications and illustrations subject to change without notice and
without incurring obligations.
FORM NO. 4AC17L-100 (05/2022)
©2022 Allied Air Enterprises LLC, a Lennox International Inc. Company
References
Read User Manual Online (PDF format)