ENGINEERED SYSTEMS 4AC17L Split System Air Conditioner Up To 17 Seer Owner’s Manual

June 9, 2024
ENGINEERED SYSTEMS

ENGINEERED SYSTEMS 4AC17L Split System Air Conditioner Up To 17 Seer

COMPRESSOR

  • High-efficiency scroll compressor
  • R410A refrigerant
  • Internally protected against high temperature motor overload conditions
  • Heavy-duty compressor sound blanket for quiet operation (optional accessory)

CABINET

  • Full metal louvered construction to protect the coil/hail protection
  • Individual louver panels; 4 screws to remove for ease of coil cleaning and service
  • Corner-mounted controls for easy service
  • Baked polyester paint finished over galvanized steel for maximum durability
  • 45-degree offset valves for easy service

COILS

  • Omni guard ™ total corrosion protection technology designed coil
  • Enhanced tube-and-fin coil design featuring MHT™ Technology
  • Lanced fins for maximum heat transfer
  • Every coil factory tested for leakproof construction
  • Raised coil prevents debris from impeding airflow

COMPONENTS

  • Factory installed high and low pressure switches
  • Thread-on pressure switches with Schrader core for simple, quick replacement
  • Filter drier shipped loose for installation flexibility
  • Fan orifice for smoother airflow and sound level reduction
  • Charged for 15 feet of line set

WARRANTY

10 year limited warranty on compressor
10 year limited warranty on all parts, extended warranty available*

*Warranty provides for a total of 10 years of limited warranty coverage (Standard 5-year limited parts warranty plus an additional 5-year limited extended parts warranty). Warranty must be registered online within 60 days of installation to qualify for 10-year coverage. Unregistered equipment defaults to 5-year coverage. See full warranty at www.alliedair.com for terms, conditions and exclusions.

NOTE:
For the latest ratings, please see www.alliedratings.com or www.AHRIdirectory.org

MODEL NUMBER GUIDE

Model Number Guide

PHYSICAL AND ELECTRICAL DATA

Model

| Voltage/Hz/Phase| Voltage Range| Min. Circuit Amp.| Max. Over Current Device (amps)| Compressor| Outdoor Fan Motor
---|---|---|---|---|---|---
Rated Load (amps)| Locked Rotor (amps)| Rated Load (amps)| Rated HP|

Nom. RPM

4AC17L18P

| 208-230/60/1| 197-253| 12.0| 15| 8.8| 42.6| 1.0| 1/6| 825
4AC17L24P| 208-230/60/1| 197-253| 15.4| 20| 11.7| 59.5| 0.7| 1/8|

1075

4AC17L30P

| 208-230/60/1| 197-253| 18.4| 25| 14.1| 71.3| 0.7| 1/8| 1075
4AC17L36P| 208-230/60/1| 197-253| 17.4| 30| 13.1| 83.1| 1.0| 1/6|

825

4AC17L41P

| 208-230/60/1| 197-253| 21.9| 35| 15.4| 92.1| 2.6| 1/3| 825
4AC17L42P| 208-230/60/1| 197-253| 24.6| 35| 18.6| 110.0| 1.4| 1/4|

825

4AC17L47P

| 208-230/60/1| 197-253| 27.5| 35| 19.9| 110.0| 2.6| 1/3| 825
4AC17L48P| 208-230/60/1| 197-253| 33.0| 50| 25.0| 120.0| 1.7| 1/4|

825

4AC17L59P

| 208-230/60/1| 197-253| 35.5| 50| 26.3| 140.6| 2.6| 1/3| 825
4AC17L60P| 208-230/60/1| 197-253| 31.3| 50| 23.9| 124.5| 1.4| 1/4|

825

UNIT DIMENSIONS (IN.)

Model

| Dimensions (inch)| Shipping Weight (Lbs.)
---|---|---
A – Width| B – Depth|

C – Height

4AC17L18P

| 28.25| 28.25| 29.25| 155
4AC17L24P| 28.25| 28.25| 37.25|

170

4AC17L30P

| 28.25| 28.25| 29.25| 180
4AC17L36P| 28.25| 28.25| 37.25|

200

4AC17L41P

| 32.25| 32.25| 33.25| 225
4AC17L42P| 32.25| 32.25| 33.25|

225

4AC17L47P

| 32.25| 32.25| 33.25| 225
4AC17L48P| 28.25| 28.25| 43.25|

230

4AC17L59P

| 32.25| 32.25| 43.25| 260
4AC17L60P| 32.25| 32.25| 43.25|

260

SOUND RATINGS

Model

| Sound Power1| Estimated Sound Pressure (dBA)2
---|---|---

Approximate Distance3

3.3 Feet (1 Meter)| 6.6 Feet (2 Meters)|

9.8 Feet (3 Meters)

4AC17L18P

| 73| 65| 59| 55
4AC17L24P| 75| 67| 61|

57

4AC17L30P

| 76| 68| 62| 58
4AC17L36P| 76| 68| 62|

58

4AC17L41P

| 75| 67| 61| 57
4AC17L42P| 76| 68| 62|

58

4AC17L47P

| 76| 68| 62| 58
4AC17L48P| 78| 70| 64|

60

4AC17L59P

| 78| 70| 64| 60
4AC17L60P| 80| 72| 66|

62

  1. Rated in accordance with AHRI standard 270 (2015). AHRI Standard 270 establishes a method of rating outdoor unitary equipment in terms of Sound Power.
  2. Rated in accordance with AHRI standard 275 (2018). AHRI Standard 275 provides the calculations for estimating the A-Weighted Sound Pressure at a given distance from the equipment. That is a more useful number because that is what humans will hear.
  3. Based only on distance factor; other factors may change this value such as:
  • Unit location (reflective surfaces adjacent to the unit)
  • Barrier shielding sources
  • Sound path/elevation
  • Outside noise sources

ACCESSORIES

System Accessory Where Used Kit Number Purpose
Liquid Line Solenoid All models 60M52 Prevents liquid migration to the

compressor especially for high liquid riser applications
Low Ambient (cooling operation)| All models| 34M72| Enables cooling demand down to 30 °F. Will require freeze stat, CC heater and TXV
Compressor Short Cycle Protector| All models| 47J27| Delays compressor start 5-7 minutes to prevent short cycling
Hard Start| Copeland| 10J42| Scroll compressors usually do not require hard start; maybe needed for utility brown-out or low voltage areas
LG| 88M91
Crankcase Heater| 18, 24, 30, 36, 42| 93M04| Prevents liquid migration to compressor in cold weather
41, 47, 48, 59, 60| Factory Installed
Sound Cover| 18, 24, 30, 36, 41| 14W00| Lowers compressor sound level
42, 47, 48, 59, 60| 14W01
Additional System Accessories (indoor section)
TXV Kit| 18, 24, 30| H4TXV01| TXVs provide superior refrigerant flow control, comfort and efficiency compared to pistons
36, 41, 42, 47, 48| H4TXV02
59, 60| H4TXV03
Outdoor Thermostat – Electric Heat| All models| 10Z23| Prevents electric heat operation above specific ambient conditions
Outdoor Thermostat – Mounting Box| All models| 31461| Mounting box for outdoor thermostat
Freezestat| All models| 93G35| Protects the compressor at low suction pressure conditions
Overflow Switch| All models| 11U75| Turn the system off, if condensate water overflows due to clogged drain pipes
Blower Time Delay| All models| 58M81| Improves system efficiency and comfort
Single Point Power Supply| All models| 21H39| Provide single power source in one junction box
Auxiliary Blower Relay| All models| 85W66| Maybe required to select multiple indoor blower speeds

REFRIGERATION DATA

Model| **Refrig. Charge (oz.) *| Piston Size| TXV| Refrigerant Line Size| Outdoor Unit Connection| Indoor Unit Connection
---|---|---|---|---|---|---
Suction| Liquid| Suction| Liquid| Suction| Liquid**

4AC17L18P

| 72| 0.051| H4TXV01| 3/4| 3/8| 3/4| 3/8| 3/4| 3/8
4AC17L24P| 82| 0.059| H4TXV01| 3/4| 3/8| 3/4| 3/8| 3/4|

3/8

4AC17L30P

| 104| 0.067| H4TXV01| 3/4| 3/8| 3/4| 3/8| 3/4| 3/8
4AC17L36P| 136| 0.072| H4TXV02| 7/8| 3/8| 7/8| 3/8| 7/8|

3/8

4AC17L41P

| 140| N/A| H4TXV02| 7/8| 3/8| 7/8| 3/8| 7/8| 3/8
4AC17L42P| 146| 0.081| H4TXV02| 7/8| 3/8| 7/8| 3/8| 7/8|

3/8

4AC17L47P

| 157| N/A| H4TXV02| 7/8| 3/8| 7/8| 3/8| 7/8| 3/8
4AC17L48P| 152| 0.084| H4TXV02| 7/8| 3/8| 7/8| 3/8| 7/8|

3/8

4AC17L59P

| 190| N/A| H4TXV03| 1-1/8| 3/8| 1-1/8| 3/8| 7/8| 3/8
4AC17L60P| 200| 0.092| H4TXV03| 1-1/8| 3/8| 1-1/8| 3/8| 7/8|

3/8

*Factory charged for 15 feet of line set
** Adapter shipped with unit
† TXV only

COOLING PERFORMANCE WITH DTC1

Outdoor Model

| Indoor Model| Capacity (BTUH)| EER2| SEER2
---|---|---|---|---
4AC17L18P| EAC4X24B| 17600| 11.7|

14.3

4AC17L24P

| EAC4X30B| 23200| 11.7| 14.3
4AC17L30P| EAC4X30B| 28600| 11.7|

14.3

4AC17L36P

| EAC4X36B| 34200| 11.7| 14.3
4AC17L41P| EAC4X49C| 40500| 12.2|

14.8

4AC17L42P

| EAC4X49C| 41500| 11.7| 14.3
4AC17L47P| EAC4X60C| 45500| 11.7|

14.3

4AC17L48P

| EAC4X60C| 47000| 11.2| 13.8
4AC17L59P| EAC4X60C| 55000| 11.7|

14.3

4AC17L60P

| EAC4X60C| 57000| 11.2|

13.8

1 DTC = Designated Tested Combination

NOTE:
For the latest AHRI system matches please visit www.alliedratings.com or www.AHRIdirectory.org

Customer Support

1-800-448-5872
All specifications and illustrations subject to change without notice and without incurring obligations.
FORM NO. 4AC17L-100 (05/2022)
©2022 Allied Air Enterprises LLC, a Lennox International Inc. Company

Logo

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals