MITSUBISHI ELECTRIC MUZ-GS15NAHZ H2i Wall Mounted Air Conditioning System Owner’s Manual

June 13, 2024
Mitsubishi Electric

MITSUBISHI-ELECTRIC-LOGO

MITSUBISHI ELECTRIC MUZ-GS15NAHZ H2i Wall-Mounted Air Conditioning System

MITSUBISHI-ELECTRIC-MUZ-GS15NAHZ-H2i-Wall-Mounted-Air-Conditioning-System-
PRODUCT

Product Information

  • Product Name: MSZ-GS15NA & MUZ-GS15NAHZ
  • Job Name: System Reference
  • Indoor Unit: 15,000 BTU/H Wall-Mounted Indoor Unit
  • Outdoor Unit: 15,000 BTU/H Hyper Heat Pump Outdoor Unit
  • Date: [Date]
  • Specifications: MSZ-GS15NA & MUZ-GS15NAHZ

Electrical:

  • Voltage: 208/230 V AC (Indoor Unit), 208/230 V AC (Outdoor Unit)
  • Current: [Current]
  • Operating Temperature Range: [Temperature Range]

Dimensions:

  • Indoor Unit: [W x D x H: In. [mm]]
  • Outdoor Unit: [W x D x H: In. [mm]]

Weight:

  • Indoor Unit: [Lbs. [kg]]
  • Outdoor Unit : [Lbs. [kg]]

Product Usage Instructions

  1. Ensure the electrical supply is compatible with the voltage requirements of the indoor and outdoor units.
  2. Select a suitable location for the installation of the indoor unit on a wall.
  3. Install the outdoor unit in a well-ventilated area, following the recommended clearances.
  4. Connect the indoor and outdoor units using the appropriate refrigerant piping.
  5. Mount any required accessories, such as the lines mounting pad or stand.
  6. If using a wired remote controller, connect it to the indoor unit.
  7. Ensure proper condensate drainage by installing the condensate disconnect switch and filter.
  8. If using a remote sensor or wireless remote controller, follow the specific instructions provided for their installation.

Note: For detailed information on accessories, refer to the user manual.

INDOOR UNIT FEATURES

  • Slim wall-mounted indoor units provide zone comfort control
  • Dual Barrier Coating applied to the heat exchanger, vanes and fan to prevent hydrophilic and hydrophobic dirt build-up
  • Optional Microparticle Filter designed to capture PM2.5
  • The outdoor unit powers the indoor unit, and should a power outage occur, the system is automatically restarted when power returns
  • Quiet operation
  • Smart Set: recalls a preferred preset temperature setting at the touch of a button
  • Built-in backup/auxiliary heater control available
  • Multiple fan speed options: Quiet, Low, Medium, High, Super-high, Auto
  • Multiple control options available:
  • Back-lit screen handheld remote controller (provided with the unit)
  • kumo cloud® smart device app for remote access
  • Third-party interface options
  • Wired or wireless controllers

OUTDOOR UNIT FEATURES

  • INVERTER-driven compressor and LEV provide high efficiency and comfort while using only the energy needed to maintain maximum performance
  • Hyper-heating performance offers 100% heating capacity at 5°F
  • Hot-Start Technology: no cold air rush at equipment startup or when restarting after Defrost Cycle
  • Quiet outdoor unit operation
  • Built-in base pan heater
  • Innovative DC fan motor leads to high efficiency and reliability
  • Blue Fin anti-corrosion treatment applied to the outdoor unit heat exchanger for increased coil protection and longer life
  • Rated for 2,000 hours spraying time per ASTM B117 Standard

SPECIFICATIONS

MSZ-GS15NA & MUZ-GS15NAHZ

Cooling at 95°F1

| Maximum Capacity| BTU/H| 18,200
---|---|---|---
Rated Capacity| BTU/H| 14,000
Minimum Capacity| BTU/H| 3,100
Maximum Power Input| W| 2,020
Rated Power Input| W| 1,100
Moisture Removal| Pints/h| 2.5
Sensible Heat Factor| 0.80
Power Factor [208V / 230V]| %| 93.0 / 93.0

Heating at 47°F2

| Maximum Capacity| BTU/H| 20,900
Rated Capacity| BTU/H| 14,000
Minimum Capacity| BTU/H| 4,800
Maximum Power Input| W| 2,030
Rated Power Input| W| 1,140
Power Factor [208V / 230V]| %| 95.0 / 95.0

Heating at 17°F3

| Maximum Capacity| BTU/H| 16,800
Rated Capacity| BTU/H| 8,700
Maximum Power Input| W| 2,020
Rated Power Input| W| 950

Heating at 5°F4

| Maximum Capacity| BTU/H| 14,000
Maximum Power Input| W| 2,150
Heating at -5°F6| Maximum Capacity| BTU/H| 11,910
Heating at -13°F7| Maximum Capacity| BTU/H| 9,820

Efficiency

| SEER2| 21.0
EER21| 12.75
HSPF2 [IV]| 9.4
COP at 47°F2| 3.6
COP at 17°F at Maximum Capacity3| 2.44
COP at 5°F at Maximum Capacity4| 1.91
COP at -5°F at Maximum Capacity6| 1.62
COP at -13°F at Maximum Capacity7| 1.33
ENERGY STAR® Certified| Yes

Electrical

| Voltage, Phase, Frequency| 208/230, 1, 60
Guaranteed Voltage Range| V AC| 187 – 253
Voltage: Indoor – Outdoor, S1-S2| V AC| 208/230
Voltage: Indoor – Outdoor, S2-S3| V DC| 24
Short-circuit Current Rating [SCCR]| kA| 5
Recommended Fuse/Breaker Size (Oudoor)| A| 15
Recommended Wire Size [Indoor – Outdoor]| AWG| 14
Power Supply| Indoor unit is powered by the outdoor unit

Indoor Unit

| MCA| A| 1.0
Fan Motor Full Load Amperage| A| 0.75
Fan Motor Output| W| 30
Airflow Rate at Cooling, Dry| CFM| 191–253–316–400–504
Airflow Rate at Cooling, Wet| CFM| 172–228–285–360–454
Airflow Rate at Heating, Dry| CFM| 191–231–285–348–437
Sound Pressure Level [Cooling]| dB[A]| 26–32–38–44–49
Sound Pressure Level [Heating]| dB[A]| 26–30–35–40–46
Drain Pipe Size| In. [mm]| 5/8 [15.88]
Coating on Heat Exchanger| Dual Barrier Coating
External Finish Color| Munsell 1.0Y 9.2/0.2
Unit Dimensions| W x D x H: In. [mm]| 31-7/16 x 9-1/8 x 11-5/8 [798 x 232 x 295]
Package Dimensions| W x D x H: In. [mm]| 33-1/2 x 12 x 14 [850 x 300 x 350]
Unit Weight| Lbs. [kg]| 23 [10.4]
Package Weight| Lbs. [kg]| 26 [11.5]
Indoor Unit Operating Temperature Range| Cooling Intake Air Temp [Maximum / Minimum]*| °F| 90 DB, 73 WB / 67 DB, 57 WB
Heating Intake Air Temp [Maximum / Minimum]| °F| 80 DB / 70 DB

NOTES:

  • AHRI Rated Conditions 1Cooling (Indoor // Outdoor) °F 80 DB, 67 WB // 95 DB, 75 WB (Rated data is determined at a fixed compressor speed) 2Heating at 47°F (Indoor // Outdoor) °F 70 DB, 60 WB // 47 DB, 43 WB 3Heating at 17°F (Indoor // Outdoor) °F 70 DB, 60 WB // 17 DB, 15 WB
  • Conditions 4Heating at 5°F (Indoor // Outdoor) °F 70 DB, 60 WB // 5 DB, 4 WB
  • Indoor/Outdoor Unit Operating Temperature Range (Cooling Air Temp [Maximum / Minimum]):
  • Applications should be restricted to comfort cooling only; equipment cooling applications are not recommended for low ambient temperature conditions.
  • Outdoor Unit Operating Temperature Range (Cooling Thermal Lock-out / Re-start Temperatures; Heating Thermal Lock-out / Re-start Temperatures):
  • System cuts out in heating mode to avoid thermistor error and automatically restarts at these temperatures.
Outdoor Unit MCA A 10.0
MOCP A 15
Fan Motor Full Load Amperage A 0.5
Airflow Rate [Cooling / Heating] CFM 1166 / 1152
Refrigerant Control LEV
Defrost Method Reverse Cycle
Coating on Heat Exchanger Blue Fin Coating
Sound Pressure Level, Cooling1 dB(A) 49
Sound Pressure Level, Heating2 dB(A) 51
Compressor Type DC inverter driven Twin Rotary
Compressor Model SNB140FQUMT
Compressor Rated Load Amps A 7.4
Compressor Locked Rotor Amps A 9.2
Compressor Oil [Type // Charge] oz. FV50S // 11.8
External Finish Color Munsell 3Y 7.8/1/1
Base Pan Heater Built-in
Unit Dimensions W x D x H: In. [mm] 31-1/2 x 11-1/4 x 21-5/8 [800 x 285 x

550]
Package Dimensions| W x D x H: In. [mm]| 37 x 15 x 24-1/2 [940 x 380 x 630]
Unit Weight| Lbs. [kg]| 85 [38]
Package Weight| Lbs. [kg]| 92 [42]
Outdoor Unit Operating Temperature Range| Cooling Air Temp [Maximum / Minimum]*| °F| 115 DB / 14 DB
Cooling Thermal Lock-out / Re-start Temperatures| °F| -4 / 0
Heating Air Temp [Maximum / Minimum]| °F| 75 DB, 65 WB / -13 DB, -14 WB
Heating Thermal Lock-out / Re-start Temperatures
| °F| -22 / -14
Refrigerant| Type| R410A
Pre-Charged Refrigerant Amount| Lbs, oz| 2.0, 9.0
Maximum Pre-Charged Piping Length| Ft. [m]| 25.0 [7.5]
Additional Refrigerant Charge Per Additional Piping Length| oz./Ft. [g/m]| 1.08 [20]
Piping| Gas Pipe Size O.D. [Flared]| In.[mm]| 1/2 [12.70]
Liquid Pipe Size O.D. [Flared]| In.[mm]| 1/4 [6.35]
Maximum Piping Length| Ft. [m]| 65 [20]
Maximum Height Difference| Ft. [m]| 40 [12]
Maximum Number of Bends| 10

NOTES:

  • AHRI Rated Conditions 1Cooling (Indoor // Outdoor) °F 80 DB, 67 WB // 95 DB, 75 WB

  • (Rated data is determined at a fixed compressor speed) 2Heating at 47°F (Indoor // Outdoor) °F 70 DB, 60 WB // 47 DB, 43 WB 3Heating at 17°F (Indoor // Outdoor) °F 70 DB, 60 WB // 17 DB, 15 WB

  • Conditions 4Heating at 5°F (Indoor // Outdoor) °F 70 DB, 60 WB // 5 DB, 4 WB

  • Indoor/Outdoor Unit Operating Temperature Range (Cooling Air Temp [Maximum / Minimum]):

  • Applications should be restricted to comfort cooling only; equipment cooling applications are not recommended for low ambient temperature conditions.
    Outdoor Unit Operating Temperature Range (Cooling Thermal Lock-out / Re- start Temperatures; Heating Thermal Lock-out / Re-start Temperatures):

  • System cuts out in heating mode to avoid thermistor error and automatically restarts at these temperatures.

INDOOR UNIT ACCESSORIES: MSZ-GS15NA

Control Interface CN24 Relay Kit □ CN24RELAY-KIT-CM3
IT Extender □ PAC-WHS01IE-E
kumo station® for kumo cloud® □ PAC-WHS01HC-E
Procon BACnet® and Modbus® Interface □ PAC-UKPRC001-CN-1
System Control Interface □ MAC-334IF-E
USNAP Adapter □ PAC-WHS01UP-E
Wireless Interface for kumo cloud® □ PAC-USWHS002-WF-2
Remote Sensor Wired Remote Sensor □ M21EAA307
Wireless temperature and humidity sensor for kumo cloud® □ PAC-USWHS003-TH-1
Wired Remote Controller Deluxe Wired MA Remote Controller† □ PAR-40MAAU
Simple Ductless Wired Remote Controller □ PAC-SDW01RC-1
Simple MA Remote Controller† □ PAC-YT53CRAU-J
Touch MA Controller† □ PAR-CT01MAU-SB
Wireless Remote Controller kumo touch™ RedLINK™ Wireless Controller □ MHK2
Lockdown bracket for remote controller □ RCMKP1CB

Condensate

| Blue Diamond (Advanced) Mini Condensate Pump w/ Reservoir & Sensor (208/230V) [recommended]| □ X87-721
Blue Diamond (MegaBlue Advanced) Condensate Pump w/ Reservoir & Sensor| □ X87-835
Blue Diamond Alarm Extension Cable — 6.5 Ft.| □ C13-192
Blue Diamond MultiTank — collection tank for use with multiple pumps| □ C21-014
Blue Diamond Sensor Extension Cable — 15 Ft.| □ C13-103
Drain Pan Level Sensor/Control| □ SS610E
Fascia Kit for MicroBlue Pump, mounts the MicroBlue and sensor directly beneath indoor unit| □ T18-016
Sauermann Condensate Pump| □ SI30-230
Disconnect Switch| (30A/600V/UL) [fits 2” X 4” utility box] – Black| □ TAZ- MS303
(30A/600V/UL) [fits 2” X 4” utility box] – White| □ TAZ-MS303W
Filter| Anti-allergy Enzyme Filter| □ MAC-408FT-E
Microparticle (PM2.5) Filter| □ MAC-EMF515FT-E

NOTES:
PAC-SF40RM-E (Unable to use with wireless remote controller)

OUTDOOR UNIT ACCESSORIES: MUZ-GS15NAHZ

Lineset| 15’ x 1/4” x 15’ / 3/8” Lineset (Twin-Tube Insulation)| □ MLS143812T-15
---|---|---
30’ x 1/4” x 30’ / 3/8” Lineset (Twin-Tube Insulation)| □ MLS143812T-30
50’ x 1/4” x 50’ / 3/8” Lineset (Twin-Tube Insulation)| □ MLS143812T-50
65’ x 1/4” x 65’ / 3/8” Lineset (Twin-Tube Insulation)| □ MLS143812T-65
Mounting Pad| Condensing Unit Mounting Pad: 24” x 42” x 3”| □ ULTRILITE2
Outdoor Unit 3-1/4 inch Mounting Base (Pair) – Plastic| □ DSD-400P
Stand| 18” Single Fan Stand| □ QSMS1801M
24” Single Fan Stand| □ QSMS2401M
Condenser Wall Bracket – Stainless Steel Finish| □ QSWBSS
Outdoor Unit Stand — 12” High| □ QSMS1201M

INDOOR UNIT DIMENSIONS

MSZ-GS15NAMITSUBISHI-ELECTRIC-MUZ-GS15NAHZ-H2i-Wall-Mounted-Air-
Conditioning-System-FIG-1

OUTDOOR UNIT DIMENSIONS: MUZ-GS15NAHZMITSUBISHI-ELECTRIC-MUZ-GS15NAHZ-
H2i-Wall-Mounted-Air-Conditioning-System-FIG-2

REQUIRED SPACE

  1. 1 4 in. or more when front and sides of the unit are clear
  2. When any 2 sides of left, right and rear of the unit are clear
  • FORM# MSZ-GS15NA & MUZ-GS15NAHZ – 202306
  • Specifications are subject to change without notice.
  • 1340 Satellite Boulevard Suwanee, GA 30024 Toll Free: 800-433-4822 www.mehvac.com
  • © 2023 Mitsubishi Electric Trane HVAC US LLC. All rights reserved.