Characteristics

  • The wireless twilight dimmer measures the light intensity and based on a set value, it sends the command to switch on the lights or pull the blinds up or down.

  • It can be combined with multifunctional switching units and blind switches.

  • The increased IP65 protection is suited to mounting on the wall or in harsh environments.

  • Integrated sensor for measuring illumination, settable in 3 ranges 1 – 100.000 lx.

  • Selection of function:
    a) twilight switch – automatically switches on upon a decrease in ambient light intensity, switches off upon an increase (appropriate for garden lights, advertisements, public lighting, etc.).
    b) light switch – automatically switches on upon an increase in ambient light intensity, switches off upon a decrease (appropriate for offices, restaurants, rooms, etc.).

  • Settable delay up to 2 minutes to eliminate unwanted switching caused by surrounding influences.

  • The twilight switch may control up to 32 units in the installation.

  • The programming button on the regulator is used for:
    a) setting a function with a switching or blind unit. b) ascertaining battery status. c) ascertaining signal quality between the unit and dimmer.

  • Battery power (1.5 V / 2x AAA – included in supply) with battery life of around 2 years based on the number of controlled units.

  • Range up to 160 m (in open space), if the signal is insufficient between the controller and unit, use the signal repeater RFRP-20 or protocol component RFIO2 that support this feature.

  • Communication frequency with bidirectional protocol iNELS RF Control.

Control options

  • he twilight / light switch RFSOU-1 can control:
    switches:
    RFSA-11B/61B/62B, RFSA-61M/66M, RFSAI-61B, RFSC-11/61, RFUS-11/61, RFJA-12B dimmers:
    RFDA-11B/71B, RFDA-73M/RGB (mode WHITE), RFDEL-71B, RFDSC-11/71 (switches light on/off, cannot set lighting intensity)

  • option of operating with RF Touch

  • option of operating with signal repeater RFRP-20

Assembly

mounting in harsh environments inELS RFSOU-1 Twilight Switch Instruction
Manual - Assembly

Place the twilight / light switch so that it is not close to any light sources and devices that could influence the ambient light sensor.

Radio frequency signal penetration through various construction materials

inELS RFSOU-1 Twilight Switch Instruction Manual - Radio frequency signal
penetration through various construction materials

Indication, settings

Before starting the programming / manual control, open the actuator housing using a screwdriver.
After completing programming / manual control, snap the housing closed again.

Prior to programming or setting the unit, use a screwdriver to open the cover.
Indication and control units are located inside the box.

  • Red LED – indication of communication and modes.

  • Green LED – indication of communication.

  • By pressing Prog for < 1s, the RFSOU-1 unit communicates with programmed units according to the selected function.

  • Setting the potentiometer Lux Fine:
    – fine adjustment of light intensity within the range.

  •  Setting the switch Range (lx):
    – selection or range.
    – within range light/twilight switch.

  • Setting of switch Function:
    – selection of unit type.
    – function setting

inELS RFSOU-1 Twilight Switch Instruction Manual - table
1,2

Note: each change in the settings of the potentiometer and rotating switches must be confirmed by pressing the Prog button.

Programming with RF actuators

inELS RFSOU-1 Twilight Switch Instruction Manual - Programming with RF
actuators

Programming RFJA

inELS RFSOU-1 Twilight Switch Instruction Manual - Programming
RFJA

Programming RF units with communication via RFRP-2

Programming

inELS RFSOU-1 Twilight Switch Instruction Manual -
Programming

Programming with the RF control unit RF Touch

inELS RFSOU-1 Twilight Switch Instruction Manual - Programming with the RF
control unit RF Touch

Delete actuator

Deleting one position of the transmitter (RFSA, RFDA)

inELS RFSOU-1 Twilight Switch Instruction Manual - Deleting one position of
the transmitter

Deleting one position of the transmitter (RFJA)inELS RFSOU-1 Twilight
Switch Instruction Manual - Deleting one position of the
transmitter Deleting the entire memory

inELS RFSOU-1 Twilight Switch Instruction Manual - Deleting the entire
memory

Function

By pressing the Prog button < 1s, the RFSOU-1 communicates with the programmed units according to the selected function and then indicates the battery status and successful connection to the programmed units.
Indicating the battery status
After terminating communication, the red LED flashes according to the battery status:
– 1x – battery OK.
– 2x – weak battery.
Indication of successful connection
If RF units are programmed in the RFSOU-1 and one of the functions 1, 2, 3, 7, 8 or 9 is selected, 2s after battery indication, successful connection is indicated:
– 2x red LED flashes in a 1-second interval – not possible to connect with any of the programmed units.
– 1x green LED flashes – connection was successful with at least one of the programmed units.
– 2x green LED flashes in a 1-second interval – connection with all programmed RF units.
Note: When setting functions 4, 5 and 6 (with RF Touch), RFSOU-1 does not indicate connection.

Replacement of a battery

inELS RFSOU-1 Twilight Switch Instruction Manual - Replacement of a
battery

Technical parameters

inELS RFSOU-1 Twilight Switch Instruction Manual - Technical
parameters

  • pay attention to the operating temperature of batteries
    Attention:
    When you instal iNELS RF Control system, you have to keep minimal distance 1 cm between each units.
    Between the individual commands must be an interval of at least 1s.

Warning

Instruction manual is designated for mounting and also for user of the device. It is always a part of its packing. Installation and connection can be carried out only by a person with adequate professional qualification upon understanding this instruction manual and functions of the device, and while observing all valid regulations. Trouble-free function of the device also depends on transportation, storing and handling. In case you notice any sign of damage, deformation, malfunction or missing part, do not install this device and return it to its seller. It is necessary to treat this product and its parts as electronic waste after its lifetime is terminated. Before starting installation, make sure that all wires, connected parts or terminals are deenergized. While mounting and servicing observe safety regulations, norms, directives and professional, and export regulations for working with electrical devices. Do not touch parts of the device that are energized ­ life threat. Due to transmissivity of RF signal, observe correct location of RF components in a building where the installation is taking place. RF Control is designated only for mounting in interiors. Devices are not designated for installation into exteriors and humid spaces. The must not be installed into metal switchboards and into plastic switchboards with metal door ­ transmissivity of RF signal is then impossible. RF Control is not recommended for pulleys etc. ­ radiofrequency signal can be shielded by an obstruction, interfered, battery of the transceiver can get flat etc. and thus disable remote control.