BEA Jamb Camera with 5V Power Supply Instruction Manual
- June 13, 2024
- BEA
Table of Contents
BEA Jamb Camera with 5V Power Supply
DESCRIPTION
- camera
- housing
- power supply / video harness
COMPONENTS
DESCRIPTION | PART NUMBER |
---|---|
CMOS Camera | 12.1000 |
2.5 mm Lens | 50.5277 |
Power/Video Harness | 20.5316 |
Housing | 70.5528 |
Housing Screws | 50.1818 |
Camera Screws | 50.5276 |
User’s Guide | 75.5779 |
Mounting Template | 75.5780 |
REQUIRED TOOLS
TOOL
Power Drill
Tape Measurer
Magnetic Phillips #0
Phillips #2
1/8” Drill Bit
1 1/4” Drill Bit
Multimeter
Caulk & Caulking Gun
PRECAUTIONS
- Shut off all power going to header before attempting any wiring procedures.
- Maintain a clean & safe environment when working in public areas.
- Constantly be aware of pedestrian traffic around the door area.
- Always stop pedestrian traffic through the doorway when performing tests that may result in unexpected reactions by the door.
- ESD (electrostatic discharge): Circuit boards are vulnerable to damage by electrostatic discharge. Before handling any board ensure you dissipate your body’s ESD charge.
- Always check placement of all wiring before powering up to ensure that moving door parts will not catch any wires and cause damage to equipment.
- Ensure compliance with all applicable safety standards (i.e. ANSI A156.10) upon completion of installation.
- DO NOT attempt any internal repair of the components. All repairs and/or component replacements must be performed by
BEA, Inc. Unauthorized disassembly or repair:
- May jeopardize personal safety and may expose one to the risk of electrical shock.
- May adversely affect the safe and reliable performance of the product resulting in a voided warranty.
- The device should not be used for purposes other than its intended use. All other uses cannot be guaranteed by the manufacturer of the sensor.
- The installer of the door system is responsible for carrying out a risk assessment and installing the sensor and the door system in compliance with applicable national and international regulations and standards on door safety.
- The manufacturer of the sensor cannot be held responsible for incorrect installations or inappropriate adjustments of the sensor.
SAFETY
The door control unit and the door cover profile must be correctly grounded.
Only trained and qualified personnel may install and setup the sensor.
Always test the proper operation of the installation before leaving the premises.
The warranty is invalid if unauthorized repairs are made or attempted by unauthorized personnel.
The jamb cam focus is preset and is not adjustable.
The jamb cam must remain powered on when the door system is powered off.
Therefore, the jamb cam power supply must be wired to an external transformer
which is wired to the 120 VAC main power.
INSTALLATION
NOTE: Make sure power is OFF before installing jamb cams
-
Determine mounting location and apply mounting template to jamb
NOTE: For best results, horizontal center line of mounting template should be 54’’ from ground -
Predrill two (2) 1/8’’ mounting holes and one (1) 1 1/4’’ camera hole
-
Determine appropriate camera orientation and mount camera into housing
NOTE: If mounting on LEFT jamb, camera wire should lead towards housing window (out of housing) and if mounting on RIGHT jamb, camera wire should lead away from housing window (into housing) -
Plug camera into power/video harness
-
Route power/video harness up jamb into door header
-
Connect RCA video out from power/video harness into appropriate RCA video in
-
Wire nut red and black power wires to external transformer
-
Fasten housing onto jamb with supplied screws
NOTE: If mounting in exterior application, apply a bead of silicone caulk to back of housing.
TECHNICAL SPECIFICATIONS
Power Supply| 6.6 – 36 VDC (+/- 10%)
6 – 28 VAC (+/- 10%)
---|---
Operating Temperature| -22° to 140° F (-30° to 60° C) (RH 95% max)
Video Output| 1.0 (Vp-p) / 75Ω
Image Sensor| CMOS
Horizontal Resolution| 480 TVL
NTSC Output| 720 (H) x 480 (V)
Sync System| Inter-Sync
Frame Rate| 30 fps
Minimum Illumination| 0.01 LUX
AE Control| Auto
Gain Control| Auto
Electronic Shutter| 1 s ~ 1/10,000 s
S/N Ratio| >50 dB
AWB| Auto
Specifications are subject to change without prior notice.
All values measured in specific conditions.
TROUBLESHOOTING
No image displaying | Power not connected | Connect power wires | ||
---|---|---|---|---|
Power not correct | Verify appropriate voltage | |||
Bad camera | Replace camera | |||
Image upside down | Camera rotated incorrectly | Rotate camera 180 degrees | ||
Distorted image | Power not correct (too low) | Verify appropriate voltage, |
increase
Bad camera| Replace camera
Dirty window| Clean window
BEA, INC. INSTALLATION/SERVICE COMPLIANCE EXPECTATIONS
BEA, Inc., the sensor manufacturer, cannot be held responsible for incorrect
installations or incorrect adjustments of the sensor/device; therefore, BEA,
Inc. does not guarantee any use of the sensor/device outside of its intended
purpose. BEA, Inc. strongly recommends that installation and service
technicians be AAADM-certified for pedestrian doors, IDA-certified for doors/
gates, and factory-trained for the type of door/gate system. Installers and
service personnel are responsible for executing a risk assessment following
each installation/service performed, ensuring that the sensor/device system
performance is compliant with local, national, and international regulations,
codes, and standards.
Once installation or service work is complete, a safety inspection of the
door/gate shall be performed per the door/gate manufacturer’s recommendations
and/or per AAADM/ANSI/DASMA guidelines (where applicable) for best industry
practices. Safety inspections must be performed during each service call –
examples of these safety inspections can be found on an AAADM safety
information label (e.g. ANSI/DASMA 102, ANSI/DASMA 107, UL294, UL325, and
International Building Code). Verify that all appropriate industry signage,
warning labels, and placards are in place.
Customer Support
Tech Support & Customer Service:
1-800-523-2462
General Tech Questions: techservices-us@BEAsensors.com | Tech Docs:
www.BEAsensors.com
Read User Manual Online (PDF format)