BURG Intro.Code Electronic Code Lock Instruction Manual
- June 12, 2024
- BURG
Table of Contents
Intro.Code Electronic Code Lock Intro.Code
Operating Manual
www.burg.de
Intro.Code Electronic Code Lock
Intro.Code A LED
B number key
C confirmation key
D reset hole
E stator
F battery compartment
G battery
H micro USB port
I closure hole
Indroduction
The electronic code lock Intro.Code is the entry into a new dimension of
digital security for steel and wooden furniture.
With its simple operation by numerical code, the lock makes everyday life
easier and impresses with its high-quality materials.
Especially the solid metal knob convinces with its noble matt chrome surface.
The lock adapts to any installation situation, thanks to common mounting holes
and replaceable cam.
Important: Please observe all warnings and read through the entire
operating instructions before you begin with the configuration.
General
The latest version of this guide is available at:
www.burg.de
Scan here for instruction video:
https://www.youtube.com/watch?v=wWhzKN0dIm0
Data Sheet
Technical Data
Dimension | Ø 43,3 mm |
---|---|
Battery | VARTA CR2450 (1x) |
Locking cycles | 3,000 |
Working temperature | -20° C to 55° C rel. humidity: 10% – 85% |
Mode | Multi-user mode, Private mode |
Material | Housing: Zamak |
Front cap: plastic
Cam: steel
Mounting dimension| 16 mm x 19 mm
Lock attachment| M19 nut (1x)
Locking direction| Left (90°), door hinge: DIN right
Right (90°), door hinge: DIN left
Cam type| B
Max. door thickness| 18 mm
Code length| 4 to 15 digits
User code (default)| 1234
Master code (default)| 4321
No. of master codes| max. 1
No. of user codes| max. 1
Scope of Delivery
- 1x locking system
- 1x cam fixing screw2 M4 x 8 mm
- 1x washer 12 mm (DIN 9021 M4)
- 1x M19 nut
- cam type B
for single packaging:
1x length 53 mm, without crank (1-36 RIH-501 G)
1x length 40 mm, crank 3 mm (1-36 RIH-514 K)
1x length 40 mm, cranking 6 mm (1-36 RIH-515 K) for industry packaging: order related
1The lock is approved for VARTA brand batteries. The use of other batteries
may result in a reduced number of possible locking cycles.
2The use of a screw with a different length may cause damage to the lock.
Optional Accessories
- opening and reset pin
- anti-twist protection (W-MSZ-01)
Default Settings
Mode | Multi-user mode 3 |
---|---|
Fake code function | Off |
Features
- ergonomic handling and high-quality design
- external battery change
- easy to retrofit, e.g. for replacement of mechanical cam locks
- latch adjustable in 45° steps
- emergency power supply via micro USB port
Product Dimensions
3Applies from versions EIRR-007 to
EIRR-010. Private Mode applies to earlier versions.
Functional Description
Mode: Fixed Assigned Authorization (private mode) In this mode, a user code is
preset with which the lock can be operated. The lock unlocks when the stored
user code is entered. A code that has not been saved is rejected by the lock.
This mode is suitable for user groups where the user rights are not to change
permanently, e.g. for an office cabinet.
Mode: Multi-User Authorization (multi-user mode)
In this mode, user codes are only valid for a single locking operation. The
lock locks when a user code is entered and unlocks when the same code is
entered. When unlocking, this code is deleted from the lock so that a new user
code can be used. The lock remains in the open state until a new user code is
used for locking. This mode is suitable for changing user groups where the
locker is only used temporarily or once, e.g. in a sports facility.
Master code
The master code authorizes the programming of the lock. In addition, the
master code can unlock the lock independently of the set mode (emergency
opening). In multi-user mode, the code used for locking is deleted after the
master code is entered.
Note: We recommend programming a private master code before putting the
lock into operation.
LED Locking Indication
If the lock is in the locked state, the green LED flashes briefly every three
seconds.
Battery Warning
If the battery voltage falls below a certain level, the LED lights up briefly
when the code is entered. If the voltage falls into the critical range, the
lock can no longer be operated.
Block Mode
If an incorrect code is entered four times in succession, the lock locks for
60 seconds. During this time, the lock rejects any code entry.
Fake Code Function
To prevent the user code from being read when it is entered, the fake code
function can be activated. In this case, a non-valid code (fake code) is
entered before or after the correct code is entered. This code may have a
maximum of 15 digits.
Configuration
-
Change the Mode
a) Multi-user mode (default)
1. Enter master code and press . A longer beep and the green LED confirm the successful process.
2. Directly press and hold the button for 2 seconds.
The green LED starts flashing.
3. Press again. Enter the numbers 4 and 4 .
4. Confirm with . A longer beep confirms the successful process.
Note: Changing the mode does not reset the lock to the default setting.
b) Private Mode
1. Enter master code and press . A longer beep and the green LED confirm the successful process.
2. Directly press and hold the button for 2 seconds.
The green LED starts flashing.
3. Press again. Enter the numbers 4 and 3 .
4. Confirm with . A longer beep confirms the successful process.
Note: Changing the mode does not reset the lock to the default setting. -
Set the Master Code and User Code
a) Master code
1. Enter current master code and press . A longer beep and the green LED confirm the successful process.
2. Directly press and hold the button for 2 seconds.
The green LED starts flashing.
3. Enter new master code and confirm with . A longer beep and the green LED confirm the successful process.
Note: User code and master code must not be the same.
Only one master code can be stored. During the storage process, the old master code is overwritten.
b) User Code (Private Mode)
1. Enter current user code and press . A longer beep and the green LED confirm the successful process.
2. Directly press and hold the button for 2 seconds.
The green LED starts flashing.
3. Enter new user code and confirm with . A longer beep and the green LED confirm the successful process.
Note: User code and master code must not be the same.
Only one master code can be stored. During the storage process, the old master code is overwritten.
c) Reset User Code
To reset the user code, the master code is entered.
When the master code is entered, the lock unlocks.
Multi-user mode: the active user code is deleted.
Private mode: the active user code is reset to factory setting ( 1-2-3-4). -
Activate / Deactivate Fake Code Function
1. Enter master code and press . A longer beep and the green LED confirm the successful process.
2. Directly press and hold the button for 2 seconds.
The green LED starts flashing.
3. Press again.
To activate, enter the numbers 4 and 2 .
To deactivate, enter the numbers 4 and 1 .
4. Confirm with . A longer beep confirms the successful process.
Operation
-
Private Mode
a) Unlock
1. Enter user code and press . A longer beep and the green LED confirm the successful process.
2. Turn the knop to the open position within 3 seconds.
Note: The lock signals an incorrect code entry with three consecutive beeps.
b) Lock
The lock locks automatically within 4 seconds. The red LED
flashes briefly. To close, turn the knob back to the starting
position until it engages. -
Mutli User Mode
a) Lock
1. Close the door and turn the knob back to its original position.
2. Press . The green LED starts flashing.
3. Enter user code and press . A longer beep and the red LED confirm the successful process.
b) Unlock
1. Enter user code and press . A longer beep and the green LED confirm the successful process.
2. Turn the knop to the open position within 3 seconds.
Note: The lock signals an incorrect code entry with three consecutive beeps. -
Unlock via Master Code
1. Enter master code and press . A longer beep and the green LED confirm the successful process.
Multi-user mode: the active user code is deleted.
Private mode: the active user code is reset to factory setting ( 1-2-3-4).
Note: The lock signals an incorrect master code entry with three consecutive beeps.
Emergency Power Supply
If the battery voltage is insufficient, the locking system can be connected to an external power supply (e.g. power supply unit, notebook or power bank) via the micro-USB connection using a micro-USB cable. The locking system can then be operated normally.
Battery Replacement
Note: We recommend to replace the batteries at the first battery warning.
-
Press the reset pin into the closure hole on the side of the lock. Turn the housing slightly to the left and pull it forward.
-
Remove the battery compartment and replace the battery according to the symbols ( + / – ) (Fig. p. 2).
Note: The surface of the battery must be free of residues and fingerprints, otherwise malfunctions may occur. If the surface is dirty, it must be cleaned with a dry cloth. -
Replace the battery compartment, slide the housing back onto the lock and turn until it clicks into place.
Note: The lock is approved for VARTA brand batteries. The use of other batteries may result in a reduced number of possible locking cycles.
Reset to Default Settings
To reset the lock, press the reset pin briefly into the reset hole on the
back. All stored data will be deleted from the lock.
Important: The reset hole can only be operated in the disassembled state.
Disposal and Battery Note
EU Directive 2012/19/EU regulates the proper take-back, treatment and
recycling of used electronic equipment.
Every consumer is required by law to dispose of batteries, accumulators or
electrical and electronic equipment („waste equipment“) powered by batteries
or accumulators separately from household waste, as they contain harmful
substances and valuable resources. Disposal can be done at a collection or
take-back point approved for this purpose, e.g. a local recycling center.
Waste equipment, batteries or rechargeable batteries are accepted there free
of charge and recycled in an environmentally friendly and resource-saving
manner.
Waste equipment, used batteries or rechargeable batteries can also be returned
to us. The return must be sufficiently stamped to the address below.
The following symbol on the waste electrical equipment, batte- ries or
accumulators indicates that they must not be disposed of with household waste:
Caution when using batteries!
The battery may explode or release flammable gases if it is mishandled,
destroyed, or the wrong type of battery is used. Do not recharge the battery,
disassemble it, expose it to extremely high temperatures or throw it into a
fire.
On batteries containing harmful substances, you will find indications in the
form of abbreviations for the ingredients cadmium (Cd), mercury (Hg) and lead
(Pb) in each case.
BURG Lüling GmbH & Co. KG
Volmarsteiner Str. 52
58089 Hagen (Germany)
+ 49 (0) 23 35 63 08-0
info@burg.de
www.burg.de
Intro.Code | 06-2023
Rev. 04
Image rights: cover, wood texture, Maksym Chornii / 123rf
Documents / Resources
| BURG
Intro.Code Electronic Code
Lock
[pdf] Instruction Manual
Intro.Code Electronic Code Lock, Electronic Code Lock, Code Lock, Lock
---|---
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>