WESTERMO L110-F2G Industrial Ethernet 10 Port Switch User Manual
- June 13, 2024
- westermo
Table of Contents
L110-F2G Industrial Ethernet 10 Port Switch
Lynx L110-F2G & L210-F2G Industrial Ethernet 10-Port
Switch
Specifications
Interface Specifications
Number of Ports: 10
General Information
Legal Information: The contents of this
document are provided as is. Except as required by applicable law,
no warranties of any kind are made in relation to the accuracy and
reliability or contents of this document, either expressed or
implied, including but not limited to the implied warranties of
merchantability and fitness for a particular purpose. Westermo
reserves the right to revise this document or withdraw it at any
time without prior notice. Under no circumstances shall Westermo be
responsible for any loss of data or income or any special,
incidental, and consequential or indirect damages howsoever caused.
More information about Westermo can be found at
www.westermo.com.
About This Guide: This guide is intended for
installation engineers and users of the Westermo products. It
includes information on safety and regulations, a product
description, installation instructions, and technical
specifications.
Software Tools: Related software tools are
available at https://www.westermo.com/support/productsupport.
License and Copyright for Included FLOSS: This
product includes software developed by third parties, including
Free/Libre Open Source Software (FLOSS). The specific license terms
and copyright associated with the software are included in each
software package respectively. Please visit the product web page
for more information. Upon request, the applicable source code will
be provided. A nominal fee may be charged to cover shipping and
media. Please direct any source code request to your normal sales
or support channel.
WeOS Management Guide: This product runs WeOS 4
(Westermo Operating System). Instructions for quick start,
configuration, factory reset, and use of USB port are found in the
WeOS Management Guide at www.westermo.com.
Safety and Regulations
Level of Warning | Description |
---|---|
WARNING | Indicates a potentially hazardous situation that may result in |
personal injury or major damage to the product.
CAUTION| Provides information to avoid misuse of the product, confusion,
or misunderstanding that may result in minor injury or moderate
damage to the product.
NOTICE| Used for highlighting general, important information that may
result in no personal injury but minor damage to the product.
NOTE| Provides additional notes and information.
w w w. we s t e r m o. c o m
Lynx L110-F2G & L210-F2G
Industrial Ethernet 10-Port Switch
OS
Table of Contents
1. General Information ……………………………………………………………… 4 1.1. Legal Information
…………………………………………………………. 4 1.2. About This Guide …………………………………………………………. 4 1.3.
Software Tools ……………………………………………………………. 4 1.4. License and Copyright for
Included FLOSS …………………………… 4 1.5. WeOS Management Guide ……………………………………………… 4
2. Safety and Regulations …………………………………………………………. 5 2.1. Warning Levels
…………………………………………………………… 5 2.2. Safety Information ……………………………………………………….. 6
2.3. Care Recommendations ………………………………………………… 8 2.4. Product Disposal
…………………………………………………………. 8 2.5. Compliance Information …………………………………………………. 9
2.5.1. Agency Approvals and Standards Compliance ……………….. 9 2.5.2. UL 62368-1
Notice ……………………………………………….. 9 2.5.3. UL 62368-1 DC Mains Notice ……………………………………
9 2.5.4. FCC Part 15.105 Class A Notice ……………………………… 10 2.5.5. AREMA
…………………………………………………………… 10 2.5.6. Corrosive Environment …………………………………………. 11
2.5.7. Simplified Declaration of Conformity ………………………….. 12
3. Product Description ……………………………………………………………. 13 3.1. Product Description
…………………………………………………….. 13 3.2. Available Models ……………………………………………………….. 13
3.3. Hardware Overview ……………………………………………………. 14 3.4. Connector Information
…………………………………………………. 15 3.4.1. Ethernet Connection TX ……………………………………….. 15
3.4.2. Power Input ……………………………………………………… 16 3.4.3. I/O Connection
………………………………………………….. 16 3.4.4. Connection to the Console Port ………………………………..
17 3.5. LED Indicators ………………………………………………………….. 18 3.6. SFP Transceivers
………………………………………………………. 18 3.7. Supported Transceivers ……………………………………………….. 19
3.8. Deviations ……………………………………………………………….. 19 3.9. Dimensions
……………………………………………………………… 20
4. Installation ………………………………………………………………………. 21 4.1. Mounting
………………………………………………………………… 21 4.2. Removal of Product ……………………………………………………. 21
4.3. Cooling …………………………………………………………………… 22 4.4. Getting Started
………………………………………………………….. 22 4.5. Configuration Via a Web Browser
…………………………………….. 23 4.6. Factory Default …………………………………………………………. 23
5. Specifications …………………………………………………………………… 25 5.1. Interface Specifications
………………………………………………… 25
2
Lynx L110-F2G & L210-F2G
5.2. Type Tests and Environmental Conditions …………………………… 28 6. Revision Notes …………………………………………………………………. 31
Lynx L110-F2G & L210-F2G
3
1. General Information
1.1. Legal Information The contents of this document are provided “as is”.
Except as required by applicable law, no warranties of any kind are made in
relation to the accuracy and reliability or contents of this document, either
expressed or implied, including but not limited to the implied warranties of
merchantability and fitness for a particular purpose. Westermo reserves the
right to revise this document or withdraw it at any time without prior notice.
Under no circumstances shall Westermo be responsible for any loss of data or
income or any special, incidental, and consequential or indirect damages
howsoever caused.
More information about Westermo can be found at www.westermo.com.
1.2. About This Guide This guide is intended for installation engineers and
users of the Westermo products.
It includes information on safety and regulations, a product description,
installation instructions and technical specifications.
1.3. Software Tools Related software tools are available at
https://www.westermo.com/support/productsupport.
1.4. License and Copyright for Included FLOSS This product includes software
developed by third parties, including Free/Libre Open Source Software (FLOSS).
The specific license terms and copyright associated with the software are
included in each software package respectively. Please visit the product web
page for more information.
Upon request, the applicable source code will be provided. A nominal fee may
be charged to cover shipping and media. Please direct any source code request
to your normal sales or support channel.
1.5. WeOS Management Guide This product runs WeOS 4 (Westermo Operating
System). Instructions for quick start, configuration, factory reset and use of
USB port are found in the WeOS Management Guide at www.westermo.com.
4
Lynx L110-F2G & L210-F2G
2. Safety and Regulations
2.1. Warning Levels Warning signs are provided to prevent personal injuries and/or damages to the product. The following levels are used:
Level of warning Description
Indicates a potentially hazardous situation
Consequence personal injury
Possible death or major injury
Consequence material damage
Major damage to the product
WARNING
Indicates a potentially hazardous situation
Minor or moderate injury
Moderate damage to the product
CAUTION
Provides information in order to avoid misuse of the product, confusion or misunderstanding
No personal injury
Minor damage to the product
NOTICE
Used for highlighting general, No personal injury but important information
Minor damage to the product
NOTE
Table 1. Warning levels
Lynx L110-F2G & L210-F2G
5
2.2. Safety Information Before installation: Read this manual completely and
gather all information available on the product. Make sure it is fully
understood. Check that your application does not exceed the safe operating
specifications for the product.
SAFETY DURING INSTALLATION The product must be installed and operated by
qualified service personnel and installed into an apparatus cabinet or
similar, where access is restricted to service personnel only. Refer to
chapter Compliance Information to see the required level of qualified service
personnel according to safety standards. Before energising and connecting
communication cables to the product, ensure a protective earthing conductor is
first connected to the protective earthing terminal (only valid for metallic
housings). Westermo recommends a cross-sectional area of at least 4 mm2. If
the product does not have a protective earthing terminal, then the DIN-rail
must be connected to protective earth. Upon removal of the product, disconnect
the product from the power supply and all other communication ports before
disconnecting the protective earthing conductor.
HAZARDOUS VOLTAGE Do not open an energised product. Hazardous voltage may
occur when connected to a power supply.
PROTECTIVE FUSE It must be possible to disconnect manually from the power
supply. Ensure compliance to national installation regulations. Replacing the
internal fuse must only be performed by Westermo qualified personnel.
POWER SUPPLY CONNECTION There are safety regulations governing the power
source that can be used in conjunction with the product. Refer to chapter
Interface Specifications.
6
Lynx L110-F2G & L210-F2G
REDUCE THE RISK OF FIRE To reduce the risk of fire, use only telecommunication
line cords with a cable diameter of AWG 26 or larger. Regarding power cable
dimensions, see chapter Interface Specifications.
CLASS 1 LASER PRODUCT Do not look directly into a fibre optical port or any
connected fibre, although the product is designed to meet the Class 1 Laser
regulations and complies with 21 CFR 1040.10 and 1040.11.
HANDLING OF SFP TRANSCEIVERS SFP transceivers are supplied with plugs to avoid
contamination inside the optical port. They are very sensitive to dust and
dirt. If the fibre optic cable is disconnected from the product, a protective
plug must be used on the transmitter/receiver. The protective plug must be
kept on during transportation. The fibre optic cable must be handled the same
way.
CORROSIVE GASES If the product is placed in a corrosive environment, it is
important that all unused connector sockets are protected with a suitable
plug, in order to avoid corrosion attacks on the gold plated connector pins.
ELECTROSTATIC DISCHARGE (ESD) Prevent electrostatic discharge damage to
internal electronic parts by discharging your body to a grounding point (e.g.
use a wrist strap).
HOT SURFACE Be aware that the surface of this product may become hot. When it
is operated at high temperatures, the external surface may exceed Touch
Temperature Limit according to the product’s relevant electrical safety
standard.
Lynx L110-F2G & L210-F2G
7
2.3. Care Recommendations Follow the care recommendations below to maintain
full operation of the product and to fulfill the warranty obligations:
· Do not drop, knock or shake the product. Rough handling above the
specification may cause damage to internal circuit boards.
· Use a dry or slightly water-damp cloth to clean the product. Do not use
harsh chemicals, cleaning solvents or strong detergents.
· Do not paint the product. Paint can clog the product and prevent proper
operation.
If the product is used in a manner not according to specification, the
protection provided by the equipment may be impaired. If the product is not
working properly, contact the place of purchase, the nearest Westermo
distributor office or Westermo technical support.
2.4. Product Disposal This symbol means that the product shall not be treated
as unsorted municipal waste when disposing of it. It needs to be handed over
to an applicable collection point for recycling electrical and electronic
equipment. By ensuring the product is disposed of correctly, you will help to
reduce hazardous substances and prevent potential negative consequences to
both the environment and human health, which could be caused by inappropriate
disposal.
Figure 1. WEEE symbol for treatment of product disposal
8
Lynx L110-F2G & L210-F2G
2.5. Compliance Information
2.5.1. Agency Approvals and Standards Compliance
Type
Approval/Compliance
EMC Environmental
· EN/IEC 61000-6-1, Immunity residential environments · EN/IEC 61000-6-2,
Immunity industrial environments · EN/IEC 61000-6-4, Emission industrial
environments · EN 50121-4/IEC 62236-4, Railway signalling and
telecommunications apparatus
· NEMA TS 2, Traffic Controller Assemblies with NTCIP Requirementsa.
Safety
· UL 62368-1, Safety Communication Technology
Marine
· DNV GL rules for classification – Ships and offshore unitsb.
a.Valid for Lx10-F2G-12VDC b.Valid for Lx10-F2G
Table 2. Agency approvals and standards compliance
2.5.2. UL 62368-1 Notice This product has been tested and found compliant to UL 62368-1, Safety for Communication Technology. In accordance with the definitions of the standard, this product shall be handled by instructed personnel. Energy source classifications are according to following:
Electrical energy source Power port ES1
Serial port ES1
Ethernet port ES1, TNV-1
I/O port
ES1
Power source
Power port PS3
Thermal energy source Enclosure
TS1
Mechanical energy source Enclosure
MS1
Radiation energy source SFP
RS1
Table 3. UL 62368-1 notice
2.5.3. UL 62368-1 DC Mains Notice In accordance with UL 62368-1, Annex DVD and
DVH then Westermo does not recommend using the mechanical enclosure/chassis
(PE) as a conductive part of the sourced earthed DC power system in a DC mains
distribution networks. If so, the transient protective barriers are
compromised, and the product will not be compliant to evaluated standards and
immunity performance according to type test table in the user guide.
The earthing electrodes shall be located at the source in the DC distribution
system and separate earth and protective earth conductors shall be provided
throughout the system.
Lynx L110-F2G & L210-F2G
9
The field wiring shall be sufficient fixated and the protective cap for the
power connector, which is supplied with the product, shall be used on DC
voltages higher than 60 VDC.
2.5.4. FCC Part 15.105 Class A Notice This product has been tested and found
to comply with the limits for a Class A digital device, pursuant to Part 15 of
the FCC Rules.
These limits are designed to provide reasonable protection against harmful
interference when the product is operated in a commercial environment.
This product generates, uses, and can radiate radio frequency energy and, if
not installed and used in accordance with the user manual, may cause harmful
interference to radio communications. Operation of this product in a
residential area is likely to cause harmful interference in which case the
user will be required to correct the interference at the users own expense.
2.5.5. AREMA L110-F2G-12VDC has been tested according to AREMA Part 11.3.3,
11.5.1 and 11.5.2.
Port
Test
Remark
DC Power 3 x UN, 80 ms UN (max)=24 VDC when powered from a vital signal battery
Table 4. AREMA Part 11.3.3 C.4. – Signal equipment surge withstand capability for DC input port
Class C Class D Class E Remarks
Temperature
X
X
X
Relative humidity
X
X
X
Vibration
X
X
X
Mechanical shock
X
X
X
Dielectric strength
X Tested with 1.5 kVAC rms
Table 5. AREMA Part 11.5.1. – Environmental Class
10
Lynx L110-F2G & L210-F2G
Enclosure port
Radiated RF immunity Power Frequency Magnetic Field Pulse Magnetic Field
DC power port
EFT/Burst Surge (1.2/50s) Conducted RF
DI-, DO-port
EFT/Burst Surge (1.2/50s) Conducted RF
Ethernet ports
EFT/Burst Surge (1.2/50s) Conducted RF
Serial ports
EFT/Burst Surge (1.2/50s) Conducted RF
External
X X X
X X
X X
X X X
X X X
Table 6. AREMA Part 11.5.2. – Exposure Class
Internal
X X X
X X X
X X X
X X X
X X X
AREMA Part 11.3.3.E. – Equipment surge withstand documentation DC power port
1. Maximum normal circuit voltage when powered from a vital signal battery is
24 VDC 2. Surge protection clamping voltage is 58.1 VDC 3. Maximum energy
handling capability is 2 J, 1 ms
2.5.6. Corrosive Environment This product has been successfully tested in a
corrosion test according to IEC 60068-2-60, method 3. This means that the
product meets the requirements to be placed in an environment classified as
ISA-S71.04 class G3.
CORROSIVE GASES If the product is placed in a corrosive environment, it is important that all unused connector sockets are protected with a suitable plug, in order to avoid corrosion attacks on the gold plated connector pins.
Lynx L110-F2G & L210-F2G
11
2.5.7. Simplified Declaration of Conformity Hereby, Westermo declares that
this product is in compliance with applicable EU directives and UK
legislations. The full declaration of conformity and other detailed
information is available at www.westermo.com/support/product-support.
Figure 2. The European Conformity and the UK Conformity Assessment markings
12
Lynx L110-F2G & L210-F2G
3. Product Description
3.1. Product Description The Lynx series consists of layer 2 or layer 3
industrial Ethernet switches, powered by WeOS, the Westermo network operating
system. The Lynx switches are the most compact switches or device servers on
the market, available with various ports depending on model, whereof two are
100 Mbit or Gbit SFP transceivers.
The Lynx series is designed for simple use in industrial applications, from
the robust DIN rail clip solution to the configurable fault contact and the
industrial level of dual power inputs.
Only industrial grade components are used which ensures a long service life. A
wide operating temperature range of -40 to +74°C (-40 to +165°F) can be
achieved with no moving parts or cooling holes in the case.
The Lynx series has been tested both by Westermo and external test institutes
to meet many EMC, isolation, vibration and shock standards, all to the highest
levels suitable for heavy industrial environments and rail trackside
applications.
WeOS has been developed by Westermo to offer cross platform and future proof
solutions. WeOS delivers unique functionality in legacy IP solutions,
supporting Modbus Gateway, virtual COM, modem replacement or several options
in dual TCP applications. For more WeOS functionality, please see the WeOS
datasheet.
3.2. Available Models
Art. no.
3643-0100 3643-0110 3643-0105
Model
L110-F2G L110-F2G-12VDC L210-F2G
100 Mbit TX ports
8 8 8
Gbit SFP ports
2 2 2
Serial ports
–
SW Rated voltage
L2 24-48 VDC L2 12-48 VDC L3 24-48 VDC
Lynx L110-F2G & L210-F2G
13
3.3. Hardware Overview
1
2
3
No. 1 3 5
5
Description LED indicators Power connection Ethernet connection TX
4
No. 2 4
Figure 3. Location of interface ports and LED indicators
Description SFP transceivers I/O connection
14
Lynx L110-F2G & L210-F2G
1
2
3
No. 1 3
Description I/O connection Accessorie cable, art. no. 1211-2027
No. 2
Description Console port
Figure 4. Location of interface ports, bottom view
3.4. Connector Information
3.4.1. Ethernet Connection TX
Illustration
Pin no. 1 2 3 4 5 6 7 8
Shield
Table 7. Ethernet connection TX
Signal TD+ TDRD+
RD-
Direction In/Out In/Out In/Out In/Out –
Description Transmitted/Received data Transmitted/Received data
Transmitted/Received data
Not connected Not connected Transmitted/Received data Not connected Not
connected Connected to PE
Lynx L110-F2G & L210-F2G
15
3.4.2. Power Input
Illustration
1 2 3 4
Position 1 2 3 4
Table 8. Power input
Product marking +DC1 +DC2 -COM -COM
Direction Input Input Input Input
Description Supply voltage Supply voltage
Common Common
The product supports redundant power connection. The positive inputs are +DC1
and +DC2, the negative input for both supplies are -COM. Connect the primary
voltage (e.g. +24 VDC) to the +DC1 pin and return to one of the -COM pins on
the power input.
3.4.3. I/O Connection
Illustration
1 2 3 4
Pin no. 1 2 3 4
Product marking Status + Status –
Digital in + Digital in –
Direction Output Output Input Input
Description Status relay contact (alarm) Status relay contact (alarm)
Digital in + Digital in –
Table 9. I/O connection
The Status output is a potential free, opto-isolated, normally closed, solid-
state relay. This can be configured to monitor various alarm events within the
unit, see WeOS Management Guide. An external load in series with an external
voltage source is required for proper functionality. For voltage/current, see
Interface Specifications.
The Digital in is an opto-isolated digital input, which can be used to monitor
external events. For voltage/current, see Interface Specifications.
External load
1
V Status –
2
3
V Digital in
4
–
Figure 5. Digital in
16
Lynx L110-F2G & L210-F2G
3.4.4. Connection to the Console Port The console port can be used to connect
to the CLI (Command Line Interface).
1. Connect the serial diagnostic cable to the console port (use only Westermo
cable 1211-2027).
2. Connect cable to your computer (USB port, if drivers are needed they can
be downloaded from the Westermo web).
3. Use a terminal emulator and connect with correct speed and format (115200,
8N1) to the assigned port.
For more information about the CLI, see the WeOS Management guide.
Accessories Description Westermo console cable RJ45 to DB9 cable
Table 10. Accessories table
Art. no. 1211-2027 1211-2210
Lynx L110-F2G & L210-F2G
17
3.5. LED Indicators
LED ON
DC1 DC2 FRNT
RSTP USR1 Ethernet 1 to 10
Status
Description
OFF
Product has no power
GREEN
All OK, no alarm condition
GREEN BLINK
Location indicator (“Here I am!”). Activated when connected to WeConfig tool, or upon request from web or/and CLI. RED BLINK during boot indicates pending cable factory reset.
RED
Alarm condition, or until product has started
up. (Alarm conditions are configurable, see
WeOS4 Management Guide)
OFF
Product has no power
GREEN
Power OK on DC1
RED
Power failure on DC1
OFF
Product has no power
GREEN
Voltage present on DC2
RED
Power failure on DC2
OFF
FRNT disabled
GREEN
FRNT OK
RED
FRNT error
BLINK
Product configured as FRNT focal point
OFF
RSTP disabled
GREEN
RSTP enabled
BLINK
Product selected as RSTP/STP root switch
Configurable, see WeOS4 Management Guide
OFF
No link
GREEN
Link established
GREEN FLASH Data traffic indication
YELLOW
Port alarm, or port is set in blocking state by link redundancy protocol
Table 11. LED indicators
Illustration
3.6. SFP Transceivers
The product supports UL and IEC certified transceivers only. See Westermo’s
modular transceivers datasheets 100 Mbit and 1 Gbit for supported SFP
transceivers, which can be downloaded from the product support pages at
www.westermo.com/support/productsupport.
18
Lynx L110-F2G & L210-F2G
Each SFP slot can hold one SFP transceiver. See “Transceiver User Guide
6100-0000” for transceiver handling instructions, which also can be downloaded
from the product support pages at www.westermo.com/support/product-support.
In the event of contamination, the optical connectors in the SFP transceivers
should only be cleaned by the use of forced nitrogen and some kind of cleaning
stick. Recommended cleaning fluids are methyl-, ethyl-, isopropyl- or isobutyl
alcohol, hexane or naphtha.
3.7. Supported Transceivers Firmware prior to 4.4.0 accepts Westermo branded
transceivers only. From 4.5.0 other transceivers are accepted with a notice
and the product will no longer be UL approved. Temperature specifications are
also depending on the used transceivers.
HANDLING OF SFP TRANSCEIVERS SFP transceivers are supplied with plugs to avoid
contamination inside the optical port. They are very sensitive to dust and
dirt. If the fibre optic cable is disconnected from the product, a protective
plug must be used on the transmitter/receiver. The protective plug must be
kept on during transportation. The fibre optic cable must be handled the same
way.
3.8. Deviations With copper transceiver 1100-0148, the specified operating
temperature of the product is 0 to 50ºC. FRNT reconfiguration times can not be
guaranteed with copper transceivers.
Lynx L110-F2G & L210-F2G
19
100 ±1
3.9. Dimensions Dimensions are stated in mm and are regardless of model.
52 ±1
96 ±1 92 ±1
34 ±1
Max 7,5mm Min 4mm
Figure 6. Dimensional drawing
20
Lynx L110-F2G & L210-F2G
4. Installation
4.1. Mounting This product should be mounted on a 35 mm DIN-rail, which is
horizontally mounted inside an apparatus cabinet or similar. It is recommended
that the DIN-rail is connected to ground. Snap on the product to the DIN-rail
according to the figure.
Figure 7. Mounting of product 4.2. Removal of Product This product has an
integrated DIN-clip. To remove the product, press down the support at the back
with a screwdriver and lift it off the DIN-rail.
Figure 8. Removal of product
Lynx L110-F2G & L210-F2G
21
4.3. Cooling This product uses convection cooling. Spacing is recommended for
the use of the product in full operating temperature range and service life.
To avoid obstructing the airflow around the product, use the following spacing
rules.
Minimum spacing of 25 mm (1 inch) above/below and 10 mm (0.4 inches)
left/right of the product is recommended.
10mm
10mm
Figure 9. Miminum spacing of product
REDUCE THE RISK OF FIRE To reduce the risk of fire, use only telecommunication
line cords with a cable diameter of AWG 26 or larger. Regarding power cable
dimensions, see chapter Interface Specifications.
4.4. Getting Started This product runs the Westermo Operating System (WeOS)
which provides several management tools that can be used for configuration of
the unit.
· WeConfig tool This is a custom Westermo tool used for discovery of attached
Westermo product.
· Web Configuration of the product using the web browser.
· CLI Configuration of the product via the Command Line Interface. Username:
admin Password: westermo
If the computer is located in the same subnet as the switch you can easily use
a web browser to configure the product. Within the web you can configure most
of the available functions. If you are not sure about the subnet consult
your network administrator.
22
Lynx L110-F2G & L210-F2G
For advanced network settings and more diagnostic information, please use the
CLI. Detailed documentation is available in the chapter “The Command Line
Management Tool” in the WeOS Management Guide.
Factory default: IP address: 192.168.2.200 Netmask: 255.255.255.0 Gateway:
disabled
4.5. Configuration Via a Web Browser The product can easily be configured via
a web browser. Open the link http://192.168.2.200 in your web browser, and you
will be prompted with a login screen, where the default settings are:
Username: admin Password: westermo
Once logged in, use the extensive integrated help function describing all
configuration options.
Two common task when configuring a new switch is to assign appropriate IP
settings, and to change the password of the admin account. The password can be
up to 64 characters long, and should consist of printable ASCII characters
(ASCII 33-126); ‘Space’ is not a valid password character.
NOTE Version of WeConfig tool must be 10.3.0 or higher.
4.6. Factory Default It is possible to set the product to factory default
settings by using two straight standard Ethernet RJ-45 cables.
1. Power off the product and disconnect all Ethernet cables (copper and
fibre). 2. Connect one Ethernet cable between Ethernet ports 3 and 10, and the
other between
Ethernet ports 6 and 7. The ports need to be connected directly by an Ethernet
cable, i.e., not via a hub or switch. Use a straight cable not a cross-over
cable when connecting the ports. 3. Power on the product. 4. Wait for the
product to start up. Control that the ON LED is flashing red. The product is
now ready to be either reset to factory default or to boot as normal.
To go ahead with factory reset:
Lynx L110-F2G & L210-F2G
23
NOTE Do not power off the product while the factory reset process is in
progress.
· Acknowledge that you wish to conduct the factory reset by unplugging the
Ethernet cables. The ON LED will stop flashing. This initiates the factory
reset process, and after approximately 1 minute the product will restart with
factory default settings. When the product has booted up, the ON LED will show
a green light, and is now ready to use.
To boot as normal:
· To skip the factory reset process, just wait for approximately 30 seconds
(after the ON LED starts flashing RED) without unplugging the Ethernet cables.
The product will conduct a normal boot with the existing settings.
24
Lynx L110-F2G & L210-F2G
5. Specifications
5.1. Interface Specifications
DC, Power port
Rated voltage Operating voltage Rated current
Lx10-F2G: 24 – 48 VDC 19 – 60 VDC 240 mA at 24 VDC 120 mA at 48 VDC
Rated frequency Inrush current
DC 22.7 mA2s at 48 VDC
Startup current Polarity Redundant power input Isolation Connector Conductor cross section Stripping length cable Tightening torque, terminal screw Terminal torque, screw flange Shielded cable
2 x rated current Reverse polarity protected Yes All other ports Detachable
screw terminal 0.2-2.5 mm² (AWG 24-12) 7 mm 0.5 – 0.6 Nm
0.3 Nm Not required
Lx10-F2G-12VDC: 12 – 48 VDC 9.8 – 60 VDC 420 mA at 12 VDC 220 mA at 24 VDC 115
mA at 48 VDC
53 mA2s at 12 VDC 20 mA2s at 48 VDC
Ethernet TX Electrical specification Data rate Duplex Circuit type Transmission range Isolation Connector Cabling Conductive chassis Number of ports
IEEE std 802.3 10 Mbit/s, 100 Mbit/s, manual or auto Full or half, manual or auto TNV-1 Up to 150 m with CAT5e cable or better All other ports RJ-45, auto MDI/MDI-X Shielded CAT5e or better is recommended Yes 8
Lynx L110-F2G & L210-F2G
25
Ethernet SFP pluggable connections (FX or TX)
Electrical specification
IEEE std 802.3
Data rate
100 Mbit/s, 1000 Mbit/s, transceivers supported
Duplex
Full or Auto, depending on transceiver
Transmission range
Depending on transceiver
Connection
SFP slot holding fibre transceiver or copper transceiver
Number of ports
1 or 2
I/O connection, Relay output
Maximum voltage/current
60 VDC/80 mA
Connect resistance
Maximum 30
Isolation
To all other ports
Connector
Detachable screw terminal
Conductor cross section
0.14 – 1.5 mm² (AWG 28-16)
Stripping length cable
7 mm
Tightening torque, terminal screw
0.22 – 0.25 Nm
Terminal torque, screw flange 0.3 Nm
I/O connection, Digital input
Maximum voltage/load current
60 VDC/2mA
Isolation
To all other ports
Connector
Detachable screw terminal
Conductor cross section
0.14 – 1.5 mm² (AWG 28-16)
Stripping length cable
7 mm
Tightening torque, terminal screw
0.22 – 0.25 Nm
Terminal torque, screw flange 0.3 Nm
Voltage levels
Logic one: >12 VDC Logic zero: <1 VDC
26
Lynx L110-F2G & L210-F2G
Console port Electrical specification Data rate Circuit type Data format Connection
TTL-level 115.2 kbit/s SELV 8 data bits, no parity, 1 stop bit, no flow control 2.5 mm jack, use only Westermo cable 1211-2027
Lynx L110-F2G & L210-F2G
27
5.2. Type Tests and Environmental Conditions
Environmental phenomena ESD Fast transients
Surge
Basic standard
EN 61000-4-2
Description Enclosure
EN 61000-4-4 EN 61000-4-5
Power port Earth port Ethernet ports I/O port Power port
Ethernet ports I/O port
Power frequency magnetic field
Pulsed magnetic field
Radiated RF immunity
EN 61000-4-8
EN 61000-4-9 EN 61000-4-3
Enclosure
Enclosure Enclosure
Conducted RF immunity
Radiated RF emission
EN 61000-4-6
CISPR 16-2-3 IEC 60945 ANSI C63,4
Power port Signal ports Earth port Enclosure
Conducted RF emission Compass safe distance
CISPR 16-2-1 IEC 60945 ANSI C63,4
IEC 60945
Power port Signal ports
Enclosure
Supply voltage surge Power supply failure
AREMA
DNVGLCG-0339
Power port Power port
Test levels
Contact: ±6 kV Air: ±8 kV ± 2 kV, direct coupling
± 2 kV, capacitive coupling clamp
L-E: ± 2 kV, 12 , 9 F, 1.2/50 s L-E: ± 2 kV, 42 , 0.5 F, 1.2/50 s L-L: ± 1 kV,
2 , 18 F, 1.2/50 s L-L: ± 1 kV, 42 , 0,5 F, 1.2/50 s L-E: ± 2 kV, 2 , direct
on shield, 1.2/50 µs L-E, L-L: ± 1 kV, 12 , 9 F, 1.2/50 s L-E, L-L: ±2 kV, 42
, 0.5 F, 1.2/50 s 300 A/m; 0, 16.7, 50, 60 Hz
300 A/m 20 V/m at (80 – 2700) MHz 10 V/m at (2.7 – 6) GHz 1 kHz sine, 80% AM
10 V, 80% AM, 1 kHz; (0.15-80) MHz
Class A (Industrial), 30 MHz to 6 GHz DNVGL-CG – Bridge and Deck Zone, 0.15
MHz to 2 GHz FCC Part 15 B, Class A, 6.5 GHz Class B (Residential), 0.15 to 30
MHz DNVGL-CG – Bridge and Deck Zone, 10 kHz to 30 MHz Standard compass (5.4°/H
deviation) = 15 cm Steering/standby steering /emergency compass (18°/H
deviation) = 10 cm 3 x UN, 80 ms (72 VDC)a. UN-100 %, 30 s
28
Lynx L110-F2G & L210-F2G
Environmental phenomena Power supply variation
Immunity to conducted low frequency interference Dielectric strength
Basic standard DNVGLCG-0339 DNVGLCG-0339
UL 62368-1
UL 62368-1 IEEE 802.3
Insulation resistance
DNVGLCG-0339
a.Only valid for L110-F2G-12VDC
Table 12. EMC and electrical conditions
Description
Power port
Power port
Power port to all other ports I/O port to all other ports Ethernet ports to
all other ports Power port to all other ports
Test levels 1.3 x UN (62.4 VDC), 0.75 x UN (18 VDC), 15 min 3 Vrms, 0.05 to 10
kHz 1.5 kVrms, 50 Hz, 1 min
500 VDC, 60 s, > 3 G
Lynx L110-F2G & L210-F2G
29
Environmental phenomena
Temperatures
Basic standard
EN 60068-2-1 EN 60068-2-2
Description Operational
Test levels
Lx10-F2G-12VDC: -40 to +74°C (-40 to +165°F)a.
Humidity
Altitude Service life MTBF Vibration
EN 60068-2-30
MIL-HDBK 217F IEC 60068-2-6 (sine)
Storage and transpor t Operational Storage and transpor t Operational
Operational
Operational
Lx10-F2G: -40 to +70°C (-40 to +158°F) -50 to +85°C (-58 to +185°F)
5-95 % relative humidity
2000 m/80 kPa 10 years 630,000 hours
3 – 13.2 Hz: 1 mm 13.2 – 100 Hz 0.7 g
5.5 – 30 Hz: 1.5 g
30 – 50 Hz: 0.42 mm 50 – 500 Hz: 4.2 gb.
Shock
IEC 60068-2-27
Operational
30 g, 11 ms 100 g, 6 msb.
Bump
IEC 60068-2-27
Operational
10 g, 11 ms
Enclosure
UL 62368-1
Zinc
Fire enclosure
Weight
0.7 kg
Degree of protection EN 60529
Enclosure
IP40
Cooling
Convection
a.Refer to “Safety and Regulations” chapter regarding touch temperature b.Might require Ethernet cables to be fastened close to the unit.
Table 13. Environmental and mechanical conditions
30
Lynx L110-F2G & L210-F2G
6. Revision Notes
Revision Rev. S
Rev. R
Date 2023-05
2022-06
Rev. Q Rev. P
2022-02 2021-04
Rev. O
–
Change description
3.4.4 Connection to the Console Port; accessories updated, 3.5 LED Indicators;
text updated
1.3 Software Tools; link updated, 3.5 LED Indicators; text updated, 4.6
Factory Default; text updated, 5.2 Type Tests and Environmental Conditions;
text updated (Altitude)
2.5.3 UL 62368-1 DC Mains Notice added
2.5.1 Agency Approvals and Standards Compliance updated, 2.5.2 UL 62368-1
Notice new chapter, 2.5.6 Simplified Declaration of Conformity text and logo
updated, 5.2 Type Tests and Environmental Conditions updated
Westermo logo updated, illustrations updated from brown to blue, new
information structure throughout the manual, 1.2 About This Guide – new
chapter, 2 Safety and Regulations – entire chapter updated, 2.5.3 AREMA – new
chapter, 3.1. Product Description updated, 3.2. Available Models new chapter,
3.5 LED Indicators updated, 3.6 SFP Transceivers updated, 3.9 Dimensions – new
chapter, 4.1 Mounting updated, 4.2 Removal of Product updated, 5.1 Interface
Specifications updated
Lynx L110-F2G & L210-F2G
31
Westermo · Metallverksgatan 6, SE-721 30 Västerås, Sweden Tel +46 16 42 80 00
Fax +46 16 42 80 01 E-mail: info@westermo.com www.westermo.com
6643-2213 REV. S 2023 05 @ Westermo Network Technologies AB, Sweden
References
- Westermo ᐅ Robust and Secure Industrial Networking Solutions
- Product support, user guides and software downloads ᐅ Westermo
- Product support, user guides and software downloads ᐅ Westermo