Installation Instructions
Healthcare Lighting HNLM4
Wet Location
LED IMPORTANT SAFETY INSTRUCTIONS
READ AND FOLLOW ALL SAFETY INSTRUCTIONS!
SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION
- To reduce the risk of death, personal injury or property damage from fire, electric shock, falling parts, cuts/abrasions, and other hazards please read all warnings and instructions included with and on the fixture box and all fixture labels.
- Before installing, servicing, or performing routine maintenance upon this equipment, follow these general precautions.
- Installation and service of luminaires should be performed by a qualified licensed electrician.
- Maintenance of the luminaires should be performed by person(s) familiar with the luminaires’ construction and operation and any hazards involved. Regular fixture maintenance programs are recommended.
- It will occasionally be necessary to clean the outside of the refractor/lens. Frequency of cleaning will depend on ambient dirt level and minimum light output which is acceptable to user. Refractor/lens should be washed in a solution of warm water and any mild, non-abrasive household detergent, rinsed with clean water and wiped dry. Should optical assembly become dirty on the inside, wipe refractor/lens and clean in above manner, replacing damaged gaskets as necessary.
- DO NOT INSTALL DAMAGED PRODUCT! This luminaire has been properly packed so that no parts should have been damaged during transit. Inspect to confirm. Any part damaged or broken during or after assembly should be replaced.
- Recycle: For information on how to recycle LED electronic products, please visit www.epa.gov.
- These instructions do not purport to cover all details or variations in equipment nor to provide every possible contingency to meet in connection with installation, operation, or maintenance. Should further information be desired or should particular problems arise which are not covered sufficiently for the purchaser’s or owner’s purposes, this matter should be referred to Acuity Brands Lighting, Inc.
WARNING
RISK OF ELECTRIC SHOCK
- Disconnect or turn off power before installation or servicing.
- Verify that supply voltage is correct by comparing it with the luminaire label information.
- Make all electrical and grounded connections in accordance with the National Electrical Code (NEC) and any applicable local code requirements.
- All wiring connections should be capped with UL approved recognized wire connectors.
CAUTION
RISK OF INJURY
- Wear gloves and safety glasses at all times when removing luminaire from carton, installing, servicing or performing maintenance.
- Avoid direct eye exposure to the light source while it is on.
WARNING
RISK OF BURN
-
Allow lamp/fixture to cool before handling.
Do not touch enclosure or light source. -
Do not exceed maximum wattage marked on luminaire label.
-
Follow all manufacturer’s warnings, recommendations and restrictions for: driver type, burning position, mounting locations/methods, replacement and recycling.
CAUTION
RISK OF FIRE
- Keep combustible and other materials that can burn, away from lamp/lens.
- Do not operate in close proximity to persons, combustible materials or substances affected by heat or drying.
CAUTION: RISK OF PRODUCT DAMAGE
Never connect components under load.
Do not mount or support these fixtures in a manner that can cut the outer
jacket or damage wire insulation.
Controls for dimming, auto-sensing, or remote control of a luminaire that are
not factory-wired to the luminaire must be checked for compatibility with the
luminaire prior to installation. LED fixtures must be powered directly off a
switched circuit.
Unless individual product specifications deem otherwise: Do not restrict
fixture ventilation. Allow for some volume of airspace around fixture. Avoid
covering LED fixtures with insulation, foam, or other material that will
prevent convection or conduction cooling.
Unless individual product specifications deem otherwise: Do not exceed
fixtures maximum ambient temperature.
Only use fixture in its intended location.
LED products are Polarity Sensitive. Ensure proper Polarity before
installation.
Electrostatic Discharge (ESD): ESD can damage LED fixtures. Personal grounding
equipment must be worn during all installation or servicing of the unit.
Do not touch individual electrical components as this can cause ESD, shorten
lamp life, or alter performance.
Some components inside the fixture may not be serviceable. In the unlikely
event your unit may require service, stop using the unit immediately and
contact an ABL representative for assistance.
Always read the fixtures complete installation instructions prior to
installation for any additional fixture specific warnings.
Always ensure that the electrical distribution system is up to NEC (and any
applicable local code) requirements.
Verify that power distribution system has proper grounding. Lack of proper
earth ground can lead to fixture failure and may void warranty.
Choose either Part 15 OR Part 18 and move to Page 3 Installation Instructions
under Delivery. Lithonia Outdoor will always use Part 15.
All luminaires that contain electronic devices that generate frequencies above
9kHz from any component within the luminaire comply with Part 15 of the FCC
Rules. Operation is subject to the following two conditions:
- This device may not cause harmful interference
- This device must accept any interference received, including interference that may cause undesired operation
This device complies with Part 18 of the FCC Rules but may cause interference with cordless and cell phones, radios, televisions, and other electronic devices. To correct the problem, move the device away from the luminaire or plug into a different outlet. This product may cause interference to radio equipment and should not be installed near maritime safety communications equipment or other critical navigation or communications equipment operating between 0.45-30MHz.
Failure to follow any of these instructions could void product warranties. For a complete listing of product Terms and Conditions, please visit www.acuitybrands.com.
Our Brands
Indoor/Outdoor
Lithonia Lighting
Carandini
Holophane
RELOC
Light Concepts| Indoor Lighting
Aculux
Gotham
Indy
Juno
Mark Architectural Lighting
Peerless
Renaissance Lighting
Winona Lighting
---|---
Outdoor Lighting
American Electric Lighting
Antique Street Lamps
Hydrel
Tersen| Controls
DARK TO LIGHT
LC&D
ROAM
Sensor Switch
Synergy
Daylighting
SunOptics
Acuity Brands Lighting, Inc. assumes no responsibility for claims arising out
of improper or careless installation or handling of its products.
ABL LED General Warnings, Form No. 503.203 © 2010, 2016 Acuity Brands
Lighting, Inc. All rights reserved. 12/01/10
The HNLM4 is designed to mount to a standard switch box mounted flush to the
wall surface.
A box with a minimum depth of 2-1/8” is required. The Steel City 72171 series
is recommended.
Installation Steps:
- Refer to the wiring diagrams on the next page to determine the appropriate connections for the project.
- Attach mounting plate (B) to junction box with screws (by others).
- Connect supply wires to driver input wires (A) per wiring diagram.
- Remove and discard nuts holding screws (D) to LED unit and faceplate (C). Do not separate LED unit from faceplate.
- Apply silicone sealant to gasket on back of faceplate.
- Set LED unit in box and align holes in faceplate to holes in box. Attach LED unit and faceplate to mounting plate with screws (D).
Maintenance & Cleaning:
No regular maintenance is required. The LED module & driver are non-
serviceable components with a 50,000 hours operating life to 70% initial
output. At 100,000 hours light output will be approximately 50% of initial.
Clean the fixture with a soft cloth moistened with mild soap and water.
Wiring:
POWER SUPPLY / DIMMING This model is available with Dimming drivers in both 120V and 277V input versions. Dimming drivers require a 0-10V fluorescent-type dimming control. For non-dimming installations, cap the purple and pink wires.
Read all instructions before installation. Do not make live connections!
NON-DIMMING INSTALLATIONS
Connect WHITE wire to power NEUTRAL.
Connect BLACK wire to power HOT.
Connect GREEN wire to power GROUND.
DIMMING INSTALLATIONS
The integral dimming driver is designed to the 0-10V IEC dimming specification
60929 and is compatible with common 0-10V dimmers and dimming systems. Do NOT
connect line voltage to dimming input wires.
Connect WHITE wire to power NEUTRAL.
Connect BLACK wire to power HOT.
Connect VIOLET wire to POSITIVE INPUT of Dimming Control.
Connect PINK wire to NEGATIVE INPUT of Dimming Control.
HealthCare Lighting
One Lithonia Way, Conyers, GA 30012
Phone: 800-315-4963
www.acuitybrands.com