Product Information
Specifications
- Unit Type: 4-Way Ceiling Cassette
- Cooling Capacity (Nominal): 5,000 BTU/H
- Heating Capacity (Nominal): 5,600 BTU/H
- Power Source: 208/230V, 1-phase, 60 Hz
- Power Consumption:
- Cooling: 0.02 kW
- Heating: 0.02 kW
- Current:
- Cooling: 0.19 A
- Heating: 0.14 A
- MCA (Minimum Circuit Ampacity):
- Cooling: 0.24 A
- Heating: 0.19 A
- Maximum Overcurrent Protection (MOCP): 15 A
- External Finish: Galvanized Steel Sheet
- External Dimensions: 22-7/16 x 22-7/16 x 8-3/16 inches [570 x 570 x 208 mm]
- Net Weight: 28.9 lbs [13.1 kg]
- Heat Exchanger: Cross fin (Aluminum fin and copper tube)
FAQ
- Q: What is the cooling capacity of the TPLFYP005FM140A ceiling cassette unit?
- A: The cooling capacity is 5,000 BTU/H.
- Q: What is the power source requirement for this unit?
- A: The unit requires a voltage of 208/230V, 1-phase, 60 Hz.
- Q: How do I control the temperature and mode of the unit?
- A: You can use either the control interface or the provided remote controller to set the desired temperature and mode.
- Q: How often should I clean or replace the air filter?
- A: It is recommended to clean or replace the air filter every 3 to 6 months, depending on usage and air quality.
GENERAL FEATURES
- Square edge, sleek design
- 3D i-see Sensor™ available as an option
- Improved installation features*
- Occupancy detection*
- Energy saving features*
- Improved occupant comfort
- Four fan speed settings including auto-fan
- Individual vane settings
- 2’ x 2’ size matches size of many ceiling tiles
- Corner-pocket design for simplified installation
- Built-in condensate lift mechanism designed to provide up to 33” of lift
- Ventilation air intake supported
Requires a PAR-33MAA-J controller
Specifications
Specifications | System |
---|---|
Unit Type | TPLFYP005FM140A |
Cooling capacity (Nominal)1 | BTU/H |
Heating capacity (Nominal)1 | BTU/H |
Power source | Voltage, Phase, Hertz |
Power Consumption
| Cooling| kW| 0.02
Heating| kW| 0.02
Current
| Cooling| A| 0.19
Heating| A| 0.14
MCA| A| 0.24
Maximum Overcurrent Protection (MOCP)| A| 15
External finish| Galvanized steel sheet
External Dimensions| In. [mm]| 22-7/16 x 22-7/16 x 8-3/16 [570 x 570 x 208]
Net weight| Lbs [kg]| 28.9 [13.1]
Heat exchanger| Cross fin (Aluminum fin and copper tube)
Fan
| Type x quantity| Turbo fan x 1
Airflow rate| CFM| 230–265–280
Motor type| DC motor
Motor Output| kW| 0.05
Motor FLA| A| 0.19
Sound pressure level (Measured in anechoic room)| dB(A)| 26–28–30
Air filter| PP honeycomb fabric (long life type)
Refrigerant| Type| R410A
Diameter of refrigerant pipe (O.D.)
| Liquid (High Pressure)| In. [mm]| 1/4 [6.35] Flare
Gas (Low Pressure)| In. [mm]| 1/2 [12.7] Flare
Diameter of drain pipe| In. [mm]| O.D. 1-1/4 [32]
NOTES
- Cooling / Heating capacity indicated at the maximum value at operation under the following conditions:
- Cooling | Indoor: 80° F (26.7° C) DB / 67° F (19.4° C) WB; Outdoor 95° F (35° C) DB
- Heating | Indoor: 70° F (21.1° C) DB; Outdoor 47° F (8.3° C) DB / 43° F (6.1° C) WB
INDOOR UNIT ACCESSORIES
INDOOR UNIT ACCESSORIES: TPLFYP005FM140A
Control Interface
| Connector cable for remote display| □ PAC-SA88HA-EP
---|---|---
IT Extender| □ PAC-WHS01IE-E
kumo station® for kumo cloud®| □ TAC-WHS01HC-E
Procon BACnet® and Modbus® Interface| □ PAC-UKPRC001-CN-1
Thermostat Interface| □ PAC-US444CN-1
Thermostat Interface| □ PAC-US445CN-1
Remote Sensor
| Flush Mount Remote Temperature Sensor| □ PAC-USSEN002-FM-1
Flush Mount Temperature Sensor| □ PAC-USSEN001-FM-1
Remote Temperature Sensor| □ PAC-SE41TS-E
Terminal Signal Adapter
| Terminal Signal Adapter| □ PAC-IT51AD-E
Terminal Signal Adapter| □ PAC-IT52AD-E
Wired Remote Controller
| Deluxe Wired MA Remote Controller†| □ TAR-40MAAU
Simple Ductless Wired Remote Controller| □ PAC-SDW01RC-1
Simple MA Remote Controller†| □ TAC-YT53CRAU-J
Smart ME Remote Controller – Backlit touchscreen| □ TAR-U01MEDU-K
Touch MA Controller†| □ TAR-CT01MAU-SB
Wireless Remote Controller
| kumo touch™ RedLINK™ Wireless Controller| □ MHK2
Wireless MA Receiver| □ PAR-SR32MA-E
Wireless MA Remote Controller| □ TAR-FL32MA-E
Wireless Receiver| □ PAR-WSC009FA-E
Wireless Remote Contoller| □ PAR-SL101A-E
Wireless Signal Receiver Panel| □ PAR-SR4LU-E
Condensate
| Blue Diamond (Advanced) Mini Condensate Pump w/ Reservoir & Sensor
(208/230V) [recommended]| □ X87-721
Blue Diamond (MicroBlue) Mini Condensate Pump (110/208/230V) up to 18,000
BTU/H| □ X86-003
Refco Condensate Pump (100-240 VAC) up to 120,000 BTU/H| □ COMBI
Control Interface
| CN24 Relay Kit| □ CN24RELAY-KIT-CM3
Remote Operation Adapter‡| □ PAC-SF40RM-E
Grille| Grille| □ TLP-18FAU
i-see Sensor® Panel
| 3D i-see Sensor® Corner Panel| □ PAC-SF1ME-E
Grille with 3D i-see Sensor®| □ TLP-18FAEU
NOTES
- High efficiency filter requires use of multi-function casement: PAC-SJ41TM-E
INDOOR UNIT DIMENSIONS
INDOOR UNIT DIMENSIONS: TPLFYP005FM140A
More Information
- Job Name: …………………..
- System Reference: …………………..
- Date: …………………..
Specifications are subject to change without notice.
© 2023 Mitsubishi Electric Trane HVAC US LLC. All rights reserved.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>