Wayfinder HNLM3 Healthcare Wayfinder Or Directional Marker With Face Illumination Square Junction Box Instruction Manual

June 13, 2024
HealthCare

Wayfinder HNLM3 Healthcare Wayfinder Or Directional Marker With Face

Illumination Square Junction Box Instruction Manual

READ AND FOLLOW ALL SAFETY INSTRUCTIONS!

SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION

  • To reduce the risk of death, personal injury or property damage from fire, electric shock, falling parts, cuts/abrasions, and other hazards please read all warnings and instructions included with and on the fixture box and all fixture
  • Before installing, servicing, or performing routine maintenance upon this equipment, follow these general
  • Installation and service of luminaires should be performed by a qualified licensed electrician.
  • Maintenance of the luminaires should be performed by person(s) familiar with the luminaires’ construction and operation and any hazards Regular fixture maintenance programs are recommended.
  • It will occasionally be necessary to clean the outside of the refractor/lens. Frequency of cleaning will depend on ambient dirt level and minimum light output which is acceptable to user. Refractor/lens should be washed in a solution of warm water and any mild, non-abrasive household detergent, rinsed with clean water and wiped dry. Should optical assembly become dirty on the inside, wipe refractor/lens and clean in above manner, replacing damaged gaskets as
  • DO NOT INSTALL DAMAGED PRODUCT! This luminaire has been properly packed so that no parts should have been damaged during Inspect to confirm. Any part damaged or broken during or after assembly should be replaced.
  • Recycle: For information on how to recycle LED electronic products, please visit epa.gov.
  • These instructions do not purport to cover all details or variations in equipment nor to provide every possible contingency to meet in connection with installation, operation, or maintenance. Should further information be desired or should particular problems arise which are not covered sufficiently for the purchaser’s or owner’s purposes, this matter should be referred to Acuity Brands Lighting,

WARNING RISK OF ELECTRIC SHOCK

  • Disconnect or turn off power before installation or servicing.
  •  Verify that supply voltage is correct by comparing it with the luminaire label information.
  •  Make all electrical and grounded connections in accordance with the National Electrical Code (NEC) and any applicable local code requirements.
  •  All wiring connections should be capped with UL approved recognized wire connectors

CAUTION: RISK OF PRODUCT DAMAGE

  • Never connect components under
  • Do not mount or support these fixtures in a manner that can cut the outer jacket or damage wire
  • Controls for dimming, auto-sensing, or remote control of a luminaire that are not factory-wired to the luminaire must be checked for compatibility with the luminaire prior to installation. LED fixtures must be powered directly off a switched
  • Unless individual product specifications deem otherwise: Do not restrict fixture ventilation. Allow for some volume of airspace around fixture. Avoid covering LED fixtures with insulation, foam, or other material that will prevent convection or conduction
  • Unless individual product specifications deem otherwise: Do not exceed fixtures maximum ambient
  • Only use fixture in its intended
  • LED products are Polarity Ensure proper Polarity before installation.
  • Electrostatic Discharge (ESD): ESD can damage LED fixtures. Personal grounding equipment must be worn during all installation or servicing of the
  • Do not touch individual electrical components as this can cause ESD, shorten lamp life, or alter
  • Some components inside the fixture may not be serviceable. In the unlikely event your unit may require service, stop using the unit immediately and contact an ABL representative for
  • Always read the fixtures complete installation instructions prior to installation for any additional fixture specific
  • Always ensure that the electrical distribution system is up to NEC (and any applicable local code)
  • Verify that power distribution system has proper grounding. Lack of proper earth ground can lead to fixture failure and may void

Choose either Part 15 OR Part 18 and move to Page 3 Installation Instructions under Delivery. Lithonia Outdoor will always use Part 15. All luminaires that contain electronic devices that generate frequencies above 9kHz from any component within the luminaire comply with Part 15 of the FCC Rules. Operation is subject to the following two conditions:

  • This device may not cause harmful interference
  • This device must accept any interference received, including interference that may cause undesired operation

This device complies with Part 18 of the FCC Rules but may cause interference with cordless and cell phones, radios, televisions, and other electronic devices. To correct the problem, move the device away from the luminaire or plug into a different outlet. This product may cause interference to radio equipment and should not be installed near maritime safety communications equipment or other critical navigation or communications equipment operating between 0.45-30MHz.

Failure to follow any of these instructions could void product warranties. For a complete listing of product Terms and Conditions, please visit www.acuitybrands.com.

Revision B I-HNLM3_WET Revision Date 10112021

HealthCare Lighting One Lithonia Way, Conyers, GA 30012 Phone: 800-315-4963 www.acuitybrands.com
The HNLM3 is designed to mount to a standard switch box mounted flush to the wall surface.A box with a minimum depth of 2-1/8” is required. The Steel City 72171 series is recommended

Installation Steps:

  1. Refer to the wiring diagrams on the next page to determine the appropriate connections for the project.
  2. Attach mounting plate (B) to junction box with screws (by others).
  3. Connect supply wires to driver input wires (A) per wiring diagram.
  4. Remove and discard nuts holding screws (D) to LED unit and faceplate (C). Do not separate LED unit from
  5. Apply silicone sealant to gasket on back of
  6. Set LED unit in box and align holes in faceplate to holes in box. Attach LED unit and faceplate to mounting plate with screws (D).

Maintenance & Cleaning:

No regular maintenance is required. The LED module & driver are non- serviceable components with a 50,000 hours operating life to 70% initial output. At 100,000 hours light output will be approximately 50% of initial. Clean the fixture with a soft cloth moistened with mild soap and water.

Wiring:

POWER SUPPLY! DIMMING This model is available with Dimming drivers in both 120V and 277V input versions. Dimming drivers require a 0-10V fluorescent-type dimming control. For non-dimming installations, cap the purple and pink wires.
Read all instructions before installation. Do not make live connections!
NON-DIMMING INSTALLATIONS Connect WHITE wire to power NEUTRAL Connect BLACK wire to power HOT. Connect GREEN wire to power GROUND

DIMMING INSTALLATIONS

The integral dimming driver is designed to the 0-10V IEC dimming specification 60929 and is compatible with common 0-10V dimmers and dimming systems. Do NOT connect line voltage to dimming input wires. Correct WHITE wire to power NEUTRAL. Connect BLACK wire to power HOT. Connect VIOLET wire to POSITIVE INPUT of Dimming Control. Connect PINK wire to NEGATIVE INPUT of Dimming Control.