HNLM6 Healthcare Wayfinder Or Directional Marker Instruction Manual

June 13, 2024
HealthCare

HNLM6 Healthcare Wayfinder Or Directional Marker

Product Information

  • Product Name: Healthcare Lighting HNLM6
  • Product Type: LED Luminaire
  • Manufacturer: HealthCare Lighting
  • Manufacturer Address: One Lithonia Way, Conyers, GA 30012
  • Manufacturer Phone: 800-315-4963
  • Website: www.acuitybrands.com

Important Safety Instructions

  • Disconnect or turn off power before installation or servicing to avoid the risk of electric shock.
  • Verify the supply voltage by comparing it with the luminaire label information.
  • Make all electrical and grounded connections in accordance with the National Electrical Code (NEC) and any applicable local code requirements.
  • Cap all wiring connections with UL approved recognized wire connectors.
  • Wear gloves and safety glasses when handling, installing, servicing, or performing maintenance on the luminaire.
  • Avoid direct eye exposure to the light source while it is on.
  • Allow the lamp/fixture to cool before handling and do not touch the enclosure or light source.
  • Do not exceed the maximum wattage marked on the luminaire label.
  • Keep combustible materials away from the lamp/lens and do not operate in close proximity to persons or substances affected by heat or drying to reduce the risk of fire.
  • Never connect components under load and avoid mounting or supporting the fixtures in a way that can damage the outer jacket or wire insulation.
  • Check compatibility of controls for dimming, auto-sensing, or remote control with the luminaire prior to installation.
  • Power LED fixtures directly off a switched circuit.
  • Ensure proper polarity before installation as LED products are polarity sensitive.
  • Use personal grounding equipment during installation or servicing to prevent electrostatic discharge (ESD) that can damage LED fixtures.
  • Do not touch individual electrical components as it can cause ESD, shorten lamp life, or alter performance.
  • If service is required, contact an ABL representative for assistance.

IMPORTANT SAFETY INSTRUCTIONS

READ AND FOLLOW ALL SAFETY INSTRUCTIONS!
SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION

  • To reduce the risk of death, personal injury or property damage from fire, electric shock, falling parts, cuts/abrasions, andother hazards please read all warnings and instructions included with and on the fixture box and all fixture labels.
  • Before installing, servicing, or performing routine maintenance upon this equipment, follow these general precautions.
  • Installation and service of luminaires should be performed by a qualified licensed electrician.
  • Maintenance of the luminaires should be performed by person(s) familiar with the luminaires’ construction and operationand any hazards involved. Regular fixture maintenance programs are recommended.
  • It will occasionally be necessary to clean the outside of the refractor/lens. Frequency of cleaning will depend on ambientdirt level and minimum light output which is acceptable to user. Refractor/lens should be washed in a solution of warmwater and any mild, non-abrasive household detergent, rinsed with clean water and wiped dry. Should optical assemblybecome dirty on the inside, wipe refractor/lens and clean in above manner, replacing damaged gaskets as necessary.
  • DO NOT INSTALL DAMAGED PRODUCT! This luminaire has been properly packed so that no parts should have beendamaged during transit. Inspect to confirm. Any part damaged or broken during or after assembly should be replaced.
  • Recycle: For information on how to recycle LED electronic products, please visit www.epa.gov.
  • These instructions do not purport to cover all details or variations in equipment nor to provide every possible contingencyto meet in connection with installation, operation, or maintenance. Should further information be desired or shouldparticular problems arise which are not covered sufficiently for the purchaser’s or owner’s purposes, this matter should bereferred to Acuity Brands Lighting, Inc.

WARNING: RISK OF ELECTRIC SHOCK

  • Disconnect or turn off power beforeinstallation or servicing.
  • Verify that supply voltage is correct bycomparing it with the luminaire labelinformation.
  • Make all electrical and groundedconnections in accordance with the NationalElectrical Code (NEC) and any applicablelocal code requirements.
  • All wiring connections should be cappedwith UL approved recognized wireconnectors.

WARNING: RISK OF BURN

  • Allow lamp/fixture to cool before handling.Do not touch enclosure or light source.
  • Do not exceed maximum wattage marked onluminaire label.
  • Follow all manufacturer’s warnings,recommendations and restrictions for: drivertype, burning position, mountinglocations/methods, replacement andrecycling.

CAUTION: RISK OF INJURY

  • Wear gloves and safety glasses at all timeswhen removing luminaire from carton,installing, servicing or performingmaintenance.
  • Avoid direct eye exposure to the light sourcewhile it is on.

CAUTION: RISK OF FIRE

  • Keep combustible and other materials thatcan burn, away from lamp/lens.
  • Do not operate in close proximity to persons,combustible materials or substancesaffected by heat or drying.

CAUTION: RISK OF PRODUCT DAMAGE

  • Never connect components under load.
  • Do not mount or support these fixtures in a manner that can cut the outer jacket or damage wire insulation.
  • Controls for dimming, auto-sensing, or remote control of a luminaire that are not factory-wired to theluminaire must be checked for compatibility with the luminaire prior to installation. LED fixtures must bepowered directly off a switched circuit.
  • Unless individual product specifications deem otherwise: Do not restrict fixture ventilation. Allow for somevolume of airspace around fixture. Avoid covering LED fixtures with insulation, foam, or other material thatwill prevent convection or conduction cooling.
  • Unless individual product specifications deem otherwise: Do not exceed fixtures maximum ambienttemperature.
  • Only use fixture in its intended location.
  • LED products are Polarity Sensitive. Ensure proper Polarity before installation.
  • Electrostatic Discharge (ESD): ESD can damage LED fixtures. Personal grounding equipment must be wornduring all installation or servicing of the unit.
  • Do not touch individual electrical components as this can cause ESD, shorten lamp life, or alterperformance.
  • Some components inside the fixture may not be serviceable. In the unlikely event your unit may requireservice, stop using the unit immediately and contact an ABL representative for assistance.
  • Always read the fixtures complete installation instructions prior to installation for any additional fixturespecific warnings.
  • Always ensure that the electrical distribution system is up to NEC (and any applicable local code)requirements.
  • Verify that power distribution system has proper grounding. Lack of proper earth ground can lead to fixturefailure and may void warranty.

FCC STATEMENT

Choose either Part 15 OR Part 18 and move to Installation Instructions under Delivery. Lithonia Outdoor will always use Part 15. All luminaires that contain electronic devices that generate frequencies above 9kHz from any component within the luminaire comply with Part 15 of the FCC Rules. Operation is subject to the following two conditions:

  1. This device may not cause harmful interference
  2. This device must accept any interference received, including interference that may cause undesired operation

This device complies with Part 18 of the FCC Rules but may cause interference with cordless and cell phones, radios, televisions, and other electronic devices. To correct the problem, move the device away from the luminaire or plug into a different outlet. This product may cause interference to radio equipment and should not be installed near maritime safety communications equipment or other critical navigation or communications equipment operating between 0.45-30MHz.

Failure to follow any of these instructions could void product warranties. For a complete listing of product Terms and Conditions, please visit www.acuitybrands.com.

Our Brands

Indoor/Outdoor

  • Lithonia Lighting
  • Carandini
  • Holophane
  • RELOC
  • Light Concepts

Indoor Lighting

  • Aculux
  • Gotham
  • Indy
  • Juno
  • Mark Architectural Lighting
  • Peerless
  • Renaissance Lighting
  • Winona Lighting

Outdoor Lighting

  • American Electric Lighting
  • Antique Street Lamps
  • Hydrel
  • Tersen

Controls

  • DARK TO LIGHT
  • LC&D
  • ROAM
  • Sensor Switch
  • Synergy

Daylighting

  • SunOptics

Acuity Brands Lighting, Inc. assumes no responsibility for claims arising out of improper or careless installation or handling of its products.

Installation Steps

The HNLM6 is designed to mount to a standard switch box mounted flush to the wall surface.
A box with a minimum depth of 2-1/8” is required. The Steel City “4G4D” series is recommended.

HNLM6-Healthcare-Wayfinder-Or-Directional-Marker-fig-1

  1. Refer to the wiring diagrams on the next page to determine the appropriate connections for the project.
  2. Connect supply wires to driver input wires (A) per wiring diagram.
  3. Set LED unit (B) in box and secure to box with screws (by others).
  4. Align studs on back of faceplate (C) over receivers in LED unit.
  5. Press faceplate onto LED unit.

Maintenance & Cleaning

  • No regular maintenance is required. The LED module & driver are non-serviceable components with a 50,000 hours operating life to 70% initial output.
  • At 100,000 hours light output will be approximately 50% of initial. Clean the fixture with a soft cloth moistened with mild soap and water.

Wiring

POWER SUPPLY / DIMMING

This model is available with Dimming drivers in both 120V and 277V input versions. Dimming drivers require a 0-10V fluorescent-type dimming control. For non-dimming installations, cap the purple and pink wires.
Read all instructions before installation. Do not make live connections!

NON-DIMMING INSTALLATIONS

HNLM6-Healthcare-Wayfinder-Or-Directional-Marker-fig-2

  • Connect WHITE wire to power NEUTRAL.
  • Connect BLACK wire to power HOT.
  • Connect GREEN wire to power GROUND.

DIMMING INSTALLATIONS

The integral dimming driver is designed to the 0-10V IC dimming specification 60929 and is compatible with common 0-10V dimmers and dimming systems. Do NOT connect line voltage to dimming input wires.

HNLM6-Healthcare-Wayfinder-Or-Directional-Marker-fig-3

  • Connect WHITE wire to power NEUTRAL.
  • Connect BLACK wire to power HOT.
  • Connect VIOLET wire to POSITIVE INPUT of Dimming Control.
  • Connect PINK wire to NEGATIVE INPUT of Dimming Control.

Contact

HealthCare Lighting

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

HealthCare User Manuals

Related Manuals