SHOWVEN F5-01207005 uFlamer Volcano Flamer Machine User Manual

June 13, 2024
Showven

SHOWVEN F5-01207005 uFlamer Volcano Flamer Machine

Warning

  • Unauthorized repair are prohibited, it may cause serious incident.
  • Make sure power supply in consistent with the rated voltage of the equipment, and the  socket must well grounded. Unplug and turn off the machine when not use
  • Before connect the power cable, communication DMX cable should well connected and ensure the command keep at firing OFF status. And safety lock stay at test mode.
  • The device can only be placed horizontally. Safety distances are marked on the device (at least 15m in all projection directions, at least 10m to the other sides of the device).
  • After turning on the device, no person allows to stay in the danger area. Ensure all persons that are part of the show be informed about the safety distance, risks and functions of the device.
  • Always have a CO2 fire extinguisher and an extinguishing blanket in case of needed.
  • If there be any doubt as to the safety operation of the device in any circumstances, the device should be taken out of service immediately. Be sure the device is in good operating condition before use. If fail to fire correctly, immediately shut down and check it accordingly. Any questions please always contact  SHOWVEN(info@showven.cn) for help.
  • Be sure to use high quality flame fluid, otherwise, it is easily lead to failure or danger. Be careful when refill the flame fluid tank. Please keep flame fluid away from heat source, sparks, fire or other possibility of ignition. Do not smoke!
  • The operator responsible for the control of uFlamer Volcano must always have a clear view of the device, so that he/she can stop the show immediately when there is danger. The main AC power switch should near operator. So that operator can turn off the power of all devices in case of abnormal.
  • The device shall not be altered and applied to other use purpose.

Disclaimers :
SHOWVEN technologies Co., Ltd excludes liability for unsafe situations, accidents and damages resulting from:

  1. Ignoring warnings or regulations as shown on flamer or this manual.
  2. Use for other applications or circumstances other than those indicated herein.
  3. Changes to the flamer, including use of non-original spare parts.
  4. Removed safety cover without authorization from SHOWVEN.
  5. Use this machine by unqualified or untrained personnel.
  6. Improper use of machine.

Foreword

Thanks for choosing SHOWVEN uFlamer Volcano. Please read following manual carefully and completely before operating this product. Operate according to instructions is very important for safety, and can elongate the service life of the machine.
Strictly follow the instruction in the manual when operate uFlamer Volcano. If you have any doubts, please contact SHOWVEN technologies Co., Ltd by info@showven.cn.
We assume the person who use or come in contact with the device are familiar with how the device should be handled. This includes proper use, maintenance and repair of the machine as defined in this user manual.

Functional Characteristics

\5-heads liquid flamer
\Independent control of each head
\Internal pump, plug and play system
\Flames up to 10m
\Reinforced stainless steel housing
\25L built-in stainless steel fuel tank
\Support automatic refueling station
\Real-time fuel level display, both electronically and mechanically
\Safety switch key
\Integrated valve block design
\Premium and independent jet valve
\Customized water-proof ignitor
\IPX3 rain-proof, can be used in rainy day
\DMX control, with both 3-pin and 5-pin XLR port
\ Compatible with fireworks firing system

Technical Specifications

\ DIMENSION: 630x460x405mm
\ HOUSING MATERIAL: 304 STAINLESS STEEL
\ WEIGHT:48Kg
\ WORK POWER: 2000W
\ INPUT:100-120V & 200-240V, 50/60Hz
\ FLAMER HEIGHT: 8-10m
\ FLAME ANGLES: 5 directions
\ FUEL: ISOPAR, ISOPROPANOL, BIOETHANOL
\ FUEL TANK CAPACITY: 25L
\ FUEL CONSUMPTION: 60mL/s per nozzle
\ WORK TEMP.: -20 to 50
\ INTERFACE: SEETRONIC 3-PIN & 5-PIN XLR
NEUTRIK PowerCON TRUE1
\ IGNITION: High voltage electron ignition
\ CONTROL: DMX, 9-60V PYRO SIGNAL
\ WATER PROOF LEVEL: IPX3

Structure of uFlamer Volcano

Structure Of Uflamer Volcano

  1. Fuel Tank Lid
  2. Top Panel
  3. Handle
  4. Control Panel
  5. Safety Loop

Connection dimension diagram of bottom bracket

Connection Dimension Diagram Of Bottom Bracket

Overview of Control Panel

Overview Of Control Panel

  1. LCD screen operate panel
  2. Pressure indicator
  3. Safety indicator
  4. 5-pin XLR Socket
  5. 110V/220V Power Socket
  6.  Auto-reset Fuse
  7. Fuel Input Quick Coupler (G1/4, ISO7241B
  8. Safety Lock
  9. ON/OFF Switch
  10. 3-pin XLR Socket
  11. DC 9V-60V fireworks igniter signal port

Operation Panel

LED Display Area:

RX : Radio receiving (reserved)
DMX : DMX signal. Flash means DMX signal available, otherwise no DMX signal
ERR : Light on when there is an error
PUMP : Light on when pump is running

Button Functions:

MENU: Switch interface to setup parameter;
+ : Parameter Up
: Parameter Down
ENTER: Confirm and save parameters (screen will flash when parameters saved)
Note: screen display will switch to main interface if not press button in 10s.

Welcome Interface:

First Line: Product model and software version
Second Line: Equipment series number

Main Interface:

First Line
DMX DMX address 1(value from 1-512);
M Channel Mode 6CH-P
6CH-P: professional channel mode;
6CH-N: normal channel mode
6CH-S: safety channel mode

Second Line
P : Pressure Value 100 (100=10bar)
L : Liquid level 50%

Alert Message:

Alert Message Explanation
E0 Test Mode
Factory Mode DMX signal blocked in factory mode
Invert ON When turned on, all angles will be mirrored
Prim Valve ON Priming Valve is open
E1 Pressure Err Pressurizer for about 13s, pressure value failed to reach

100%, system will report E1.

Possible fault: No fuel, pump failure, pipeline problem etc.

E2 P Relief Err| Pipeline can’t release pressure leads to pressure relief error.

Possible fault: pressure release valve failure, pipeline problem or

control system problem etc.

E4 Ext Ignite ON| The Ext Ignite Time is switched to ON
E6 Tip Err| if the machine slant over 45° , it stops running, system will report E6
---|---
E7 Low Fuel| When fuel       0 report E7 low fuel

Interface setup:

6CH Normal Mode / 6CH Pro Mode
Press “MENU” to switch through setup menu.

Menu Range Explanation
Set DMX Address 1~512 DMX address setup

6CH Safe Mode
Press “MENU” to switch through setup menu.

Menu Range Explanation
Set DMX Address 1~512 DMX address setup
Safety Address 1~512 Safety Address

Advanced Interface:

Press “MENU” 3s enters advanced interface, press “MENU” to switch interface, press “MENU” 3s
can back to main interface.

Menu Contents Explanation
Drive Test OFF / Pump / Igniter / Relief Valve / Jet Valve
1. Pump Pump running 1s, if pressure reached the target value, the pump will

not running. Keep safety Lock located at USER MODE

before test.

2. Igniter| Ignition from head No.1 to 5
3. Relief Valve| Relief valve will be on and off 3 times
4. Priming Valve| Priming Valve will on and off 3 times
5. Jet Valve 1| 6s after Relief Valve was on, related Jet Valve will on and off 3 times. Keep safety Lock located at USER MODE before test.
6. Jet Valve 2
7. Jet Valve 3
8. Jet Valve 4
9. Jet Valve 5
Ext Ignite| OFF  / ON| Trigger through 9-60V Ext Ignite signal (such as fireworks ignitor signal) ON/OFF switch. Firing all 5 heads.
Ext Ignite Time| 0.1-2.0 S| Firing time setup when activated through

Ext Ignite signal

Language| English / Chinese| Language switch
Mode Select| OFF  / ON| Turn ON/OFF tip over function
DMX channel mode| 6CH Normal Mode / 6CH Pro Mode/ 6CH Safe Mode| DMX channel mode switch, detail info please check 5.DMX control
Default Parameter| OFF   / ON| Reset default parameter settings
Invert| OFF   / ON| When turned on, all angles will be mirrored.
Fuel Input| OFF   / ON| When ON, operators can fuel machine

through Fuel Input Quick Coupler

PV ON Fuel level| 0-80% (default value

20%)

| When fuel level lower than set value, priming valve will turn on automatically.
---|---|---
PV Off Fuel Level| 10%-100% (default value

100%)

| When fuel level reached set value, priming valve will turn off automatically
PV EMER OPEN| OFF  / ON| Default value is OFF

ON: Turn on the Priming Valve for 3s

Current Voltage| 12V| Mainboard power supply voltage display

Operation Instructions

Direction explanation
Please read the safety distance printed on top panel of CIRCLE FLAMER carefully.

Direction Explanation

1.1-5 indicate the related head number of uFlamer Volcano. Right side one is head 1, head 3 is in the middle, left side is head 5.
2. Audience side and control side are indicated in the picture.
3. Safety distances for uFlamer Volcano are indicated in above picture. At least 15m in all projection directions, at least 10m to the audience side and control side.

Quick Operation Sheet

Immediately upon receiving the machine, carefully unpack the packing carton, check the machine received in good condition. Ensure safety operation of machine, please do following below operation procedures when operate uFlamer Volcano.

Operation step Schematic diagram and explanation Explanation
Installation The device can only be placed horizontally, if placed on truss,
please locked with extra safety ropes.
Locate safety lock at TEST MODE Before operate machine please locate safety

lock at TEST MODE. TEST MODE: operator can test the device, but the fuel ejection function disabled, so there is no fuel eject and flames.

USER MODE: the device can

| | generate flames normally. Please strictly follow the safety distance requirement, remove all human, animal or flammable objects in the danger area.
---|---|---
Fueling| | Please fuelling with high quality fuel according to requirement of this manual
Power and DMX cable connection| | Make sure power supply in consistent with the rated voltage of the equipment, and the socket must well grounded.
Switch ON the machine| | Please confirm safety lock located at TEST MODE before switch on the POWER ON/OFF.
Set DMX address| Quick Operation Sheet| Please refer to 5. DMX control.
Compression| | Host controller: Press ”pre -heat” button (light on) DMX console: switch DMX value of channel 6 to 50 -200
Check device status in TEST MODE| | Reconfirm safety lock located at TEST MODE before test. In this status, igniter will activated, but there is no flame.
Pressure Relief| | Host controller: Press “pre -heat” key (light off) DMX console: switch DMX value of channel 6 to 0 -49/201 -255
Press the safety lock to USER MODE| Quick Operation
Sheet| Before switch to USER MODE, Please strictly follow the safety distance requirement s, remove all human, animal or flammable objects in the danger area.
Pressurize| | Host controller: Press” pre -heat” button (light on) DMX console: switch DMX value of channel 6 to 50 -200
Input firing sequence| Quick Operation Sheet| For example, if want to firing sequence 31 Host Controller: input 31 @sequence DMX console: channel 5 DMX value @ 80 -81
Firing| Quick Operation Sheet| Host controller: Press “FIRING” key DMX console: switch DMX value of channel 3 to 254 -255
Pressure Relief| | Relief pressure when show finished or CIRCLE FLAMER not use for a long period. Host controller: Press “pre-heat” key (light off) DMX console: switch DMX value of channel 6 to 0-49/201-255
Switch safety lock to TEST MODE| | Guarantee safety use for next time
Power off| | Power off, tear down power cable and DMX cable, pack up the device when it is cooled down.

Angle Definitions

Below schematic shows 5 heads and the projection directions of uFlamer Volcano from Audience Side view.

Angle Definitions

Firing sequence list

uFlamer Volcano with more than 97 preset firing sequences. Operator use related channel DMX value or sequence No. to access certain sequence. Sequence list as below:

Single Ignition Sequence List

Sequence No.| Ignition head No.| ****

Description

| Flame Activity| Firing Duration

(for reference)

| CH5 DMX

Reference

Value

---|---|---|---|---|---
1| 1| Single ignition SHORT

flame

| Static| 0.1s| 3-5
2| 2| Single ignition SHORT flame| Static| 0.1s| 6-7
3| 3| Single ignition SHORT| Static| 0.1s| 8-10
| | flame| | |
---|---|---|---|---|---
4| 4| Single ignition SHORT flame| Static| 0.1s| 11-12
5| 5| Single ignition SHORT flame| Static| 0.1s| 13-15
6| 1| Single ignition LONG flame| Static| 0.28s| 16-17
7| 2| Single ignition LONG

flame

| Static| 0.28s| 18-20
8| 3| Single ignition LONG flame| Static| 0.28s| 21-22
9| 4| Single ignition LONG

flame

| Static| 0.28s| 23-25
10| 5| Single ignition LONG

flame

| Static| 0.28s| 26-28

Step Sequences List

Sequence No.| Ignition head No.| Description| Flame Activity| Firing Duration (for reference)| CH5 DMX

Reference

Value

---|---|---|---|---|---
11| Step 1-5| SHORT flame Step

sequence

| L -> R| 0.54s| 29-30
12| Step 5-1| SHORT flame Step sequence| R -> L| 0.54s| 31-33
13| Step

1>3>5>2>4

| SHORT flame Step

sequence

| L>M>R>L>

R

| 0.54s| 34-35
14| Step

5>3>1>4>2

| SHORT flame Step

sequence

| R>M>L>R>

L

| 0.54s| 36-38
15| Step

1>5>2>3>4

| SHORT flame Step

sequence

| L>R>L>M>

R

| 0.54s| 39-40
16| Step 5>1>4>3>2| SHORT flame Step sequence| R>L>R>M> L| 0.54s| 41-43
17| Step1>5>2

4>3

| SHORT flame Step sequence| L>R>L>R> M| 0.54s| 44-45
18| Step 5>1>4>2>3| SHORT flame Step sequence| R>L>R>L> M| 0.54s| 46-48
19| Step

2>4>1>5>3

| SHORT flame Step

sequence

| L>R>L>R>

M

| 0.54s| 49-50
20| Step 4>2>5>1>3| SHORT flame Step sequence| R>L>R>L> M| 0.54s| 51-53
21| Step

2>4>3>1>5

| SHORT flame Step

sequence

| L>R>M>L>

R

| 0.54s| 54-56
22| Step

4>2>3>5>1

| SHORT flame Step

sequence

| R>L>M>R>

L

| 0.54s| 57-58
23| Step 2>3>4>1>5| SHORT flame Step sequence| L>M>R>L> R| 0.54s| 59-61
24| Step 4>3>2>5>1| SHORT flame Step sequence| R>M>L>R> L| 0.54s| 62-63
25| Step 3>1>5>2>4| SHORT flame Step sequence| M>L>R>L> R| 0.54s| 64-66
26| Step

3>5>1>4>2

| SHORT flame Step

sequence

| M>R>L>R>

L

| 0.54s| 67-68
27| Step

3>2>4>1>5

| SHORT flame Step

sequence

| M>L>R>L>

R

| 0.54s| 69-71
28| Step

3>4>2>5>1

| SHORT flame Step

sequence

| M>R>L>R>

L

| 0.54s| 72-73
29| Step 2>3>4| SHORT flame Step sequence| L>M>R| 0.32s| 74-76
---|---|---|---|---|---
30| Step 4>3>2| SHORT flame Step sequence| R>M>L| 0.32s| 77-79
31| Step 1>3>5| SHORT flame Step

sequence

| L>M>R| 0.32s| 80-81
32| Step 5>3>1| SHORT flame Step sequence| R>M>L| 0.32s| 82-84
33| Step 1>5| SHORT flame Step

sequence

| L->R| 0.21s| 85-86
34| Step 5>1| SHORT flame Step

sequence

| R->L| 0.21s| 87-89
35| Step 2>4| SHORT flame Step sequence| L->R| 0.21s| 90-91
36| Step 4>2| SHORT flame Step sequence| R->L| 0.21s| 92-94
37| Step 1-5| LONG flame Step

sequence

| L->R| 1.45s| 95-96
38| Step5-1| LONG flame Step

sequence

| R->L| 1.45s| 97-99
39| Step 1>3>5>2>4| LONG flame Step sequence| L>M>R>L> R| 1.45s| 100-101
40| Step

5>3>1>4>2

| LONG flame Step

sequence

| R>M>L>R>

L

| 1.45s| 102-104
41| Step

1>5>2>3>4

| LONG flame Step

sequence

| L>R>L>M>

R

| 1.45s| 105-107
42| Step 5>1>4>3>2| LONG flame Step sequence| R>L>R>M> L| 1.45s| 108-109
43| Step1>5>2

4>3

| LONG flame Step

sequence

| L>R>L>R>

M

| 1.45s| 110-112
44| Step

5>1>4>2>3

| LONG flame Step

sequence

| R>L>R>L>

M

| 1.45s| 113-114
45| Step

2>4>1>5>3

| LONG flame Step

sequence

| L>R>L>R>

M

| 1.45s| 115-117
46| Step

4>2>5>1>3

| LONG flame Step

sequence

| R>L>R>L>

M

| 1.45s| 118-119
47| Step 2>4>3>1>5| LONG flame Step sequence| L>R>M>L> R| 1.45s| 120-122
48| Step 4>2>3>5>1| LONG flame Step sequence| R>L>M>R> L| 1.45s| 123-124
49| Step

2>3>4>1>5

| LONG flame Step

sequence

| L>M>R>L>

R

| 1.45s| 125-127
50| Step 4>3>2>5>1| LONG flame Step sequence| R>M>L>R> L| 1.45s| 128-130
51| Step

3>1>5>2>4

| LONG flame Step

sequence

| M>L>R>L>

R

| 1.45s| 131-132
52| Step

3>5>1>4>2

| LONG flame Step

sequence

| M>R>L>R>

L

| 1.45s| 133-135
53| Step 3>2>4>1>5| LONG flame Step sequence| M>L>R>L> R| 1.45s| 136-137
54| Step 3>4>2>5>1| LONG flame Step sequence| M>R>L>R> L| 1.45s| 138-140
55| Step 2>3>4| LONG flame Step

sequence

| L>M>R| 0.86s| 141-142
56| Step 4>3>2| LONG flame Step sequence| R>M>L| 0.86s| 143-145
57| Step 1>3>5| LONG flame Step

sequence

| L>M>R| 0.86s| 146-147
58| Step 5>3>1| LONG flame Step sequence| R>M>L| 0.86s| 148-150
---|---|---|---|---|---
59| Step 1>5| LONG flame Step sequence| L>R| 0.57s| 151-152
60| Step 5>1| LONG flame Step

sequence

| R>L| 0.57s| 153-155
61| Step 2>4| LONG flame Step sequence| L>R| 0.57s| 156-158
62| Step 4>2| LONG flame Step

sequence

| R>L| 0.57s| 159-160
63| Step

15>3>24

| SHORT flame Step

sequence

| LR>M>LR| 0.40s| 161-163
64| Step 24>3>15| SHORT flame Step sequence| LR>M>LR| 0.40s| 164-165
65| Step 15>24>3| SHORT flame Step sequence| LR>LR>M| 0.40s| 166-168
66| Step

3>24>15

| SHORT flame Step

sequence

| M>LR>LR| 0.40s| 169-170
67| Step

3>15>24

| SHORT flame Step

sequence

| M>LR>LR| 0.40s| 171-173
68| Step 24>15>3| SHORT flame Step sequence| LR>LR>M| 0.40s| 174-175
69| Step

24>135

| SHORT flame Step

sequence

| LR>LMR| 0.25s| 176-178
70| Step

135>24

| SHORT flame Step

sequence

| LMR>LR| 0.25s| 179-181
71| Step 15>234| SHORT flame Step sequence| LR>LMR| 0.25s| 182-183
72| Step

234>15

| SHORT flame Step

sequence

| LMR>LR| 0.25s| 184-186
73| Step

15>3>24

| LONG flame Step

sequence

| LR>M>LR| 0.86s| 187-188
74| Step

24>3>15

| LONG flame Step

sequence

| LR>M>LR| 0.86s| 189-191
75| Step

15>24>3

| LONG flame Step

sequence

| LR>LR>M| 0.86s| 192-193
76| Step 3>24>15| LONG flame Step sequence| M>LR>LR| 0.86s| 194-196
77| Step 3>15>24| LONG flame Step sequence| M>LR>LR| 0.86s| 197-198
78| Step

24>15>3

| LONG flame Step

sequence

| LR>LR>M| 0.86s| 199-201
79| Step 24>135| LONG flame Step sequence| LR>LMR| 0.57s| 202-203
80| Step

135>24

| LONG flame Step

sequence

| LMR>LR| 0.57s| 204-206
81| Step

15>234

| LONG flame Step

sequence

| LR>LMR| 0.57s| 207-209
82| Step 234>15| LONG flame Step sequence| LMR>LR| 0.57s| 210-211

Multi ignition firing sequence list

Sequence No.| Ignition head No.| Description| Flame Activity| Firing Duration (for reference)| CH5 DMX

Reference

Value

---|---|---|---|---|---
83| 12345| Multi ignition SHORT flame| Static| 0.1s| 212-214
84| 1245| Multi ignition SHORT flame| Static| 0.1s| 215-216
---|---|---|---|---|---
85| 234| Multi ignition SHORT flame| Static| 0.1s| 217-219
86| 135| Multi ignition SHORT

flame

| Static| 0.1s| 220-221
87| 15| Multi ignition SHORT flame| Static| 0.1s| 222-224
88| 24| Multi ignition SHORT

flame

| Static| 0.1s| 225-226
89| 12345| Multi ignition LONG

flame

| Static| 0.28s| 227-229
90| 1245| Multi ignition LONG flame| Static| 0.28s| 230-232
91| 234| Multi ignition LONG flame| Static| 0.28s| 233-234
92| 135| Multi ignition LONG

flame

| Static| 0.28s| 235-237
93| 15| Multi ignition LONG

flame

| Static| 0.28s| 238-239
94| 24| Multi ignition LONG flame| Static| 0.28s| 240-242
95| 3| Multi ignition LONG

flame

| Static| User defined| 243-244
96| 234| simultaneously| Static| User defined| 245-247

97| 12345| simultaneously| Static| User defined| 248-255

DMX control

Normal Channel Mode

Channel Function
CH1 Manual mode head selection

0: all five heads                                 1-51: head NO.1 52-102: head NO.2                    103-153:  head NO.3

154-204: head NO. 4                            205-255: head NO.5

CH2| /
CH3| Ignition ON/OFF 0~253: ignition OFF; 254~255: ignition ON
CH4| Firing duration setup

0 and 255 is permanent firing (8s is limit duration firing time, 5 heads simultaneously firing limit time is 2s);

1~254 correspond to 10~2540ms duration time (Manual firing duration = DMX

Value * 10ms)

CH5| Program sequence setup

0-2: no preset sequence; set according to CH1 and CH4;

3~255: preset sequence. DMX Value = 2+ Sequence No. * 2.55 (round off). CH1 and

CH4 invalid.

CH6| Mode setup

0~49: Pressure Relief Mode (Emergency Stop) 50~200: Firing Mode

201~255: Pressure Relief Mode (Emergency Stop)

Professional Channel Mode

Channel Function
CH1 Head NO.1     0~253: Firing OFF    254~255: Firing ON
CH2 Head NO.2     0~253: Firing OFF    254~255: Firing ON
CH3 Head NO.3     0~253: Firing OFF    254~255: Firing ON
CH4 Head NO.4     0~253: Firing OFF    254~255: Firing ON
CH5 Head NO.5     0~253: Firing OFF    254~255: Firing ON
CH6 Mode setup

0~49: Pressure Relief Mode (Emergency Stop) 50~200: Firing Mode

201~255: Pressure Relief Mode (Emergency Stop)

Safety Channel Mode

Channel Function
CH1 Manual mode head selection

0: all five heads                                    1-51: head NO.1

52-102: head NO.2                              103-153:  head NO.3

154-204: head NO. 4                          205-255:  head NO.5

CH2| /
CH3| Ignition ON/OFF 0~253: ignition OFF; 254~255: ignition ON
CH4| Firing duration setup

0 and 255 is permanent firing (8s is limit duration firing time, 5 heads simultaneously firing limit time is 2s);

1~254 correspond to 10~2540ms duration time (Manual firing duration = DMX Value * 10ms)

CH5| Program sequence setup

0-2: no preset sequence; set according to CH1 and CH4.

3~255: preset sequence. DMX Value = 2+ Sequence No. * 2.55 (round off). CH1 and

CH4 invalid.

CH6| Mode setup

0~49: Pressure Relief Mode (Emergency Stop) 50~200: Firing Mode

201~255: Pressure Relief Mode (Emergency Stop)

SHOWVEN Flamer Nozzle Information

SHOWVEN offer two types of nozzles to generate different effect height. Nozzle M and Nozzle L. Standard configuration is Nozzle M.

Nozzle Types

  • SFSMA002 Nozzle M Short flame:5~7m Long flame:8~10m

  • SFSMA003 Nozzle L Short flame:3~5m Long flame:6~8m

Nozzle replacement

  • Change nozzle
    Use 14mm outer hexagon socket wrench to disassemble the nozzle, clean the nozzle and nozzle socket with air gun (air compressor), change a different nozzle and install it.

Nozzle disassemble tool: SFMET944

Change nozzle

  • Ignitor Position Adjustment
    After change the nozzle please adjust the ignitor’s position according to below parameters. The default position when we ship out from factory is for Nozzle M (standard nozzle). When replace to nozzle L (indoor nozzle) need to remove the ignitor a little bit to the center, makes the ignitor closer to the fuel stream.

Nozzle| a       mm| b       mm| Short flame height      m| Long flame height     m
---|---|---|---|---
M| 4 0.5| 4 0.5| 5~7| 8~10
L| 2.5          0.5| 4 0.5| 3~5| 6~8

Note: Do unplug the power cable when service flamer.

SHOWVEN host controller ZK6200/ZK6300

Hardware description:
\ MODEL: ZK6200/ZK6300
\ DIMENSION: 390×300×110mm
\ WEIGHT: 3.5kg
\ VOLTAGE: 100-240V, 50/60Hz
\ POWER: 15W
\ MAX CASCADE OF DEVICE: 18units (ZK6200)/ 54units (ZK6300)
\ SUPPORT MACHINES: SPARKULAR series, CIRCLE FLAMER series, SONICBOOM series

SHOWVEN host controller introduction:

  1. Standard DMX512 signal output
  2. Support 18uits (ZK6200) or 54units (ZK6300) of uFlamer Volcano
  3. 5 standard dynamic modes: Synchronization, Center to Ends, Ends to Center, Left to Right, Right to Left. And an user definable Special Effect mode, support 8 files, each file support 36000 lines maximum (effects lasts for 30min)
  4. Multi trigger sources: manual, music or midi input
  5. RDMX monitoring function: system can send back uFlamer Volcano working status info such as pressure, warming etc. and display on the screen
  6. Emergency stop function

Operational Panel

Operational Panel

  1. Cable connection area
  2. Manual firing operation region
  3. Mode selection area
  4. LCD display area
  5. Edit/Control area

Maintenance

  1. To maintain the system in good performance and running status, it is recommended to running the device at least once per month.
  2. Maintenance of the nozzle: Nozzle need to be cleaned up , and it is recommended that once every six months (depending on the environment and frequency of use). In the process of using the equipment, if the flame shape is seriously deformed or the fuel injection line is significantly  deformed or coarsened, the nozzle should be remove immediately for cleaning.
  3. Maintenance of the O-ring: If it is found that the O-ring of the nozzle is damaged or ageing when cleaning the nozzle, the O-ring should be replaced in time (material and size of O-ring:
    fluororubber O-ring, the outermost diameter is 14 mm, and the line diameter is 2 mm).

Accessories list

No. Part No. Description QTY
1 RMWAS025 Fluororubber O-ring 5
2 RMBOT036 Safety loop 2

Warranty Instructions

Sincere thanks for your choosing uFlamer Volcano, you will receive quality service from us.
▲ The product warranty period is one year. If there are any quality problems within 7 days after shipping out from our factory, we can exchange a brand new same model machine for you.
▲ We will offer free of charge maintenance service for machines which with hardware malfunction (except for the instrument damage caused by human factors)in warranty period. Please don’t repair machine without factory permission.

★ Below situations NOT included in warranty service:

  1. Damage caused by improper transportation, usage, management, and maintenance, or damage caused by human factors;
  2. Disassemble, modify or repair products without Showmen’s permission;
  3. Damage caused by external reasons (lightning strike, power supply etc)
  4. Damage caused by improper installation or use;
    For product damage not included in warranty range, we can provide paid service.
    ★ Invoice and warranty card are necessary when applying for maintenance service from SHOWVEN.

Warranty Card

Product Name:| | Serial No.|
---|---|---|---
Purchase Date:|
Tel:|
Address:|
Info. feedback about the problem:|
Actual problem:|
Maintenance

detail:

|
Service Engineer:| | Service Date:|

CUSTOMER SUPPORT

Tel: +86-731-83833068
Web: www.showven.cn E-mail: info@showven.cn
Add: Liyuan Economic Development Zone, Changsha, 410300, Hunan Province,
P.R.China

QR Code

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals