MITSUBISHI ELECTRIC PLFY-EP48NEMU-ER1 48000 BTU-H 33 X 33 Inch 4-Way Ceiling Cassette Instructions

June 13, 2024
Mitsubishi Electric

CITYMULTI®
PLFY-EP48NEMU-ER1
48,000 BTU/H 33” X 33” 4-WAY CEILING CASSETTE

MITSUBISHI ELECTRIC PLFY-EP48NEMU-ER1 48000 BTU-H 33 X 33 Inch 4-Way Ceiling
Cassette

Job Name:
System Reference:
Date:

GENERAL FEATURES

  • Square edge, sleek design
  • 3D turbo fan enabling increased airflow
  • Built-in 3D i-see Sensor®*
  • Improved installation features*
  • Occupancy detection*
  • Energy saving features*
  • Improved occupant comfort
  • Four fan speed settings including auto-fan
  • Corner pocket design for simplified installation
  • Built-in condensate lift mechanism designed to provide up to 33-7/16″ of lift
  • Ventilation air intake supported

**3D i-See sensor® settings requires either PAR-40MAAU controller

Specifications System
Unit Type PLFY-EP48NEMU-ER1
Cooling capacity (Nominal)1 BTU/H
Heating capacity (Nominal)1 BTU/H
Power source Voltage, Phase, Hertz
Power Consumption Cooling
Heating kW
Current Cooling
Heating A
MCA A
Maximum Overcurrent Protection (MOCP) A
External finish Galvanized steel sheet
External Dimensions In. [mm]
Net weight Lbs [kg]
Heat exchanger Cross fin (Aluminum fin and copper tube)
Fan Type x quantity
Airflow rate CFM
Motor type DC motor
Motor Output kW
Motor FLA A
Sound pressure level (Measured in anechoic room) dB(A)
Air filter PP honeycomb (long life filter, anti-bacterial type)
Refrigerant Type
Diameter of refrigerant pipe (O.D.) Liquid (High Pressure)

[9.52] Flare
Gas (Low Pressure)| In. [mm]| 5/8 [15.88] Flare
Diameter of drain pipe| In. [mm]| O.D. 1-1/4 [32]

NOTES:
1 Cooling / Heating capacity indicated at the maximum value at operation under the following conditions:
Cooling | Indoor: 80° F (26.7° C) DB / 67° F (19.4° C) WB; Outdoor 95° F (35° C) DB
Heating | Indoor: 70° F (21.1° C) DB; Outdoor 47° F (8.3° C) DB / 43° F (6.1° C) WB

INDOOR UNIT ACCESSORIES: PLFY-EP48NEMU-ER1

Control Interface BACnet® and Modbus® Interface □ PAC-UKPRC001-CN-1
CN24 Relay Kit □ CN24RELAY-KIT-CM3
IT Extender □ PAC-WHS01IE-E
kumo station® for kumo cloud® □ PAC-WHS01HC-E
Thermostat Interface □ PAC-US444CN-1
Thermostat Interface □ PAC-US445CN-1
Remote Sensor Flush Mount Remote Temperature Sensor □ PAC-USSEN002-FM-1
Flush Mount Temperature Sensor □ PAC-USSEN001-FM-1
Terminal Signal Adapter Terminal Signal Adapter □ PAC-IT51AD-E
Terminal Signal Adapter □ PAC-IT52AD-E
Wired Remote Controller Deluxe Wired MA Remote Controller† □ PAR-40MAAU
Simple MA Remote Controller† □ PAC-YT53CRAU-J
Smart ME Remote Controller – Backlit touchscreen □ PAR-U01MEDU-K
Touch MA Controller† □ PAR-CT01MAU-SB
Wireless Remote Controller kumo touch™ Red LINK™ Wireless Controller □ MHK2
Wireless MA Receiver □ PAR-FA32MA-W
Wireless MA Remote Controller □ PAR-FL32MA-E
Wireless Remote Controller □ PAR-SL101A-E
Wireless Signal Receiver Panel □ PAR-SR4LU-E
Casement Multi-function Casement □ PAC-SJ41TM-E
Condensate Blue Diamond (Advanced) Mini Condensate Pump w/ Reservoir & Sensor
(208/230V) [recommended] □ X87-721
Blue Diamond (Mega Blue Advanced) Condensate Pump w/ Reservoir & Sensor

X87-835
Blue Diamond Multi Tank — collection tank for use with multiple pumps| □ C21-014
Blue Diamond Sensor Extension Cable — 15 Ft.| □ C13-103
Refco Condensate Pump (100-240 VAC) up to 120,000 BTU/H| □ COMBI
Sauermann Condensate Pump| □ SI30-230
Filter| High Efficiency Filter Element**| □ PAC-SH59KF-E
Shutter Plate| Shutter Plate| □ PAC-SJ37SP-E

NOTES:
**High efficiency filter requires use of multi-function casement: PAC-SJ41TM-E

INDOOR UNIT DIMENSIONS: PLFY-EP48NEMU-ER1

NOTE

  1. PLEASE CHOOSE THE GRILLE FROM A STANDARD GRILLE, AUTO-GRILLE.

  2. REINFORCE THE SUSPENSION BOLT BY EARTHQUAKE RESISTANCE SUPPORTING MATERIAL WHICH USING FOR SWING PREVENTION IN ACCORDANCING WITH THE NECESSARY OF EARTHQUAKE RESISTANCE ETC.SPECIALLY IN THE CASE WITHOUT CEILING MATERIAL, CONFIRM REINFORCING

  3. AS FOR SUSPENSION BOLT, PLEASE USE M10 OR W3/8. (PROCURED AT LOCAL SITE)

  4. AS FOR DRAIN PIPE, PLEASE USE VP-25(O.D. ø1-1/4″(ø32) PVC TUBE).
    DRAIN PUMP INCLUSION. RAISE IS MAX 70-7/18″(850mm) FROM THE CEILING.

  5. ELECTRICAL BOX MAY BE REMOVED FOR THE SERVICE PURPOSE.
    MAKE SURE TO SLACK THE ELECTRICAL WIRE LITTLE BIT FOR CONTROL/POWER WIRES CONNECTION.

  6. THE HEIGHT OF THE INDOOR UNIT IS ABLE TO BE ADJUSTED WITH THE GRILLE ATTACHED.

  7. WHEN INSTALLING THE BRANCH DUCTS, BE SURE TO INSULATE ADEQUATELY. OTHERWISE CONDENSATION AND DRIPPING MAY OCCUR. (IT BECOMES THE CAUSE OF DEW DROPS/WEAR DEW.)

  8. AS FOR NECESSARY INSTALLATION/SERVICE SPACE, PLEASE REFER TO THE RIGHT AT FIGURE.

  9. OUTLINE DWG REFER TO EXCLUSIVE OUTLINE DWG WHEN INSTALL OPTION MULTIFUNCTION CASEMENT AND OPTION HIGH PERFORMANCE FILTER

Unit: in (mm)

MITSUBISHI ELECTRIC PLFY-EP48NEMU-ER1 48000 BTU-H 33 X 33 Inch 4-Way Ceiling
Cassette - 1

1340 Satellite Boulevard Suwanee, GA 30024
Toll Free: 800-433-4822 www.mehvac.com

FORM# PLFY-EP48NEMU-ER1 – 202211
Specifications are subject to change without notice. © 2022 Mitsubishi Electric Trane HVAC US LLC. All rights reserved.

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Mitsubishi Electric User Manuals

Related Manuals