PARKSIDE PHGA 1300 House and Garden Pump Instruction Manual

June 13, 2024
PARKSIDE

PARKSIDE PHGA 1300 House and Garden Pump

PARKSIDE-PHGA-1300-House-and-Garden-Pump-product

Product Information

  • Product Name: HOUSE & GARDEN WATER PUMP PHGA 1300 A1
  • Model Number: PHGA 1300 A1
  • Description: The HOUSE & GARDEN WATER PUMP is a versatile device designed for use in both household and garden settings. It can be used to pump water efficiently and effectively.

Product Usage Instructions

  1. Before using the device, unfold the page containing the illustrations and familiarize yourself with all the functions of the device.
  2. Ensure that you have received all the components mentioned in the scope of delivery.
  3. Connect the water pump to a suitable power source.
  4. Turn on the power switch to activate the device.
  5. The device has an automatic mode that can be selected by following the instructions provided in section 4.1 to 4.5 of the user manual.
  6. If you prefer to set a specific time for the device to operate, you can use the time mode. Refer to section 5 to 13 of the user manual for instructions on how to set the time and duration of operation.
  7. Always ensure that the water pump is used in a safe and secure location, away from any potential hazards.
  8. Refer to the table of contents in the user manual for detailed information on various sections and topics covered.

Before reading, unfold the page containing the illustrations and familiarize yourself with all functions of the device.

Explanation of the symbols on the device

  • Before commissioning, read and observe the operating manual and safety instructions!
  • Observe warning and safety instructions!
  • Specification of the sound power level in dB
  • Input voltage / frequency
  • Nominal power
  • Weight
  • Flow rate per hour
  • Max. pressure delivered
  • Max. fluid temperature
  • Protected from water splashes
  • The product complies with the applicable European directives.

Introduction

MANUFACTURER:
Scheppach GmbH
Günzburger Straße 69
D-89335 Ichenhausen

DEAR CUSTOMER,
We hope your new tool brings you much enjoyment and success.

NOTE:
In accordance with the applicable product liability laws, the manufacturer of this device assumes no liability for damage to the device or caused by the device arising from:

  • Improper handling
  • Failure to comply with the operating instructions.
  • Repairs carried out by third parties, unauthorized specialists.
  • Installing and replacing non-original spare parts,
  • Improper use
  • Failures of the electrical system in the event of the electrical regulations and VDE provisions 0100, DIN 57113 /VDE0113 not being observed.

Note:
Read the whole text of the operating manual before assembly and commissioning.
This operating manual should help you to familiarize yourself with your product and to use it for its intended purpose.
The operating manual includes important instructions for the safe, proper and economic operation of the product, for avoiding danger, for minimizing repair costs and downtimes and for increasing the reliability and extending the service life of the product.
In addition to the safety instructions in this operating manual, you must also observe the regulations applicable to the operation of the product in your country.
Keep the operating manual package with the power tool at all times and store it in a plastic cover to protect it from dirt and moisture. They must be read and carefully observed by all operating personnel before starting the work.
The product may only be used by personnel who have been trained to use it and who have been instructed with respect to the associated hazards.
The required minimum age must be observed.
In addition to the safety instructions in this operating manual and the separate regulations of your country, the generally recognized technical rules relating to the operation of such ma-chines must also be observed.
We accept no liability for accidents or damage that occur due to a failure to observe this manual and the safety instructions.

Device description (fig. 1-2)

PARKSIDE-PHGA-1300-House-and-Garden-Pump- \(1\) PARKSIDE-PHGA-1300-House-and-Garden-Pump- \(2\)

  1. Pressure connection (1 inch internal thread) 1a Locking screw
  2. Transport handle
  3. LCD display
  4. MODE button
  5. SET button
  6. CHECK button
  7. Fastening points (diameter of 6 mm)
  8. Ventilation screw
  9. Water drain plug
  10. Suction connection (1 inch internal thread)
  11. Locking screw
  12. Pre-filter locking screw
  13. Pre-filter
  14. Multifunction adapter
    • Double nipple
    • Angle piece

Scope of delivery

  • Garden pump and domestic waterworks
  • 2x multifunction adapters (two pieces)
  • Operating manual

Proper use

The machine may only be used in the intended manner. Any use beyond this is improper. The user/operator, not the manufacturer, is responsible for damages or injuries of any type resulting from this.
An element of the intended use is also the observance of the safety instructions, as well as the assembly instructions and operating information in the operating manual. Persons who operate and maintain the machine must be familiar with it and must be informed about potential dangers.
In addition, the applicable accident prevention regulations must be strictly observed. Other general occupational health and safety-related rules and regulations must be observed. The liability of the manufacturer and resulting damages are excluded in the event of modifications of the machine.

Area of application

  • For watering and irrigation of green areas, vegetable beds and gardens.
  • For operating lawn sprinklers.
  • With pre-filter for drawing water from ponds, streams, rain-water barrels, rainwater cisterns and wells.

Pumped media
For pumping clear water (fresh water), rainwater or light deter-gent solutions / domestic water.

  • The maximum temperature of the pumped liquid must not exceed +35°C.
  • This garden pump and domestic waterworks must not be used to pump flammable, gaseous or explosive liquids.
  • The pumping of aggressive liquids (acids, lyes, silo seepage juice etc.), as well as liquids with abrasive (sanding) materials (sand) must also be avoided.

The machine may only be operated with original parts and original accessories from the manufacturer.
The safety, operating and maintenance specifications of the manufacturer, as well as the dimensions specified in the technical data, must be observed
Please note that our equipment was not designed with the intention of use for commercial or industrial purposes. We assume no guarantee if the device is used in commercial or industrial applications, or for equivalent work.

Safety instructions

General power tool safety warnings
WARNING! Read all safety warnings, instructions, illustrations and specifications provided with this electric tool. Failure to follow all instructions listed be-low may result in electric shock, fire and/or serious injury.
Save all warnings and instructions for future reference.
The term “power tool” in the warnings refers to your mains-operated (corded) power tool or battery-operated (cordless) power tool.

General safety instructions

  • This product can be used by children from 8 years of age as well as by persons with reduced physical, sensory or mental capabilities or with a lack of experience or knowledge, if they are supervised or if they have been trained in the safe use of the device and understand the resultant hazards.
  • Children may not play with the product.
  • Cleaning and user maintenance must not be carried out by children unsupervised.
  • Persons who are unfamiliar with the operating manual may not use the product. The product is not to be used by persons under the age of 16.
  • The product must not be operated if there are people in the water.
  • Keep children away from the running engine.
  • Dispose of the packaging material properly.
  • Do not use the product in the vicinity of combustible fluids or gases. There is a risk of fire or explosion if disregarded.
  • The pumping of aggressive, abrasive (scouring), corrosive, flammable (e.g. motor fuels) or explosive liquids, salt water, cleaning agents and foodstuffs is not permitted.
  • Store the product in a dry place and out of reach of children.
  • The temperature of the pumped liquid shall not exceed 35°C.
  • Do not work with a damaged, incomplete or modified product without the consent of the manufacturer. Before commissioning, have a specialist check that the required electrical protective measures are in place.
  • Supervise the product during operation in order to protect the garden pump and domestic waterworks for automatic shut-down and against running dry. Check the function of the float switch regularly (see chapter “Commissioning”). Failure to do so will invalidate warranty and liability claims.
  • Please note that the garden pump and domestic waterworks is not suitable for continuous operation (e.g. for watercourses in garden ponds). Regularly check the product for proper function.
  • Please note that lubricants are used in the product, which may cause damage or contamination due to leakage. Do not use the garden pump and domestic waterworks in gar-den ponds with fish or valuable plants. If lubricants leak out, they may contaminate the liquid.
  • Do not carry or attach the product by the cable or hose.
  • Protect the product against frost and running dry.
  • Only use original spare parts and accessories and do not modify the product.
  • Please read the information on “Cleaning, maintenance, storage” in the operating manual. All additional measures, in particular opening the product, must be carried out by a qualified electrician. In the event of repair, always contact our service centre.

Electrical safety instructions

  • When operating the product, the power plug must be freely accessible after installation.

  • Before you put your new the garden pump and domes-tic waterworks and into operation, have it professionally checked:

    • Earthing, connection of the neutral line and residual cur-rent circuit breaker must comply with the safety regulations of the power supply companies and function properly,
    • Protect the electrical plug connections from moisture.
    • If there is a risk of flooding, fit the plug connections in the flood-proof area.
  • Ensure that the mains voltage corresponds to the specifications on the type plate.

  • Carry out the electrical installation in accordance with the national regulations.

  • Only connect the product to a socket with a residual cur-rent circuit breaker (FI switch) with a rated residual triggering current of up to 30 mA; Fuse at least 6 amps.

  • Before each use, always check the product, cable and plug for damages. Defective cables must not be repaired but re-placed with a new ones.
    Have product damages repaired by a specialist.

  • If the connection cable of this product is damaged it must be replaced by the manufacturer or their customer services personnel or by a similarly qualified person, in order to avoid hazards.

  • Do not use the cable to pull the plug out of the outlet.

  • Protect the cable from heat, oil and sharp edges.

  • Do not carry or attach the product by the cable.

  • Use only extension cables that are splash-proof and intended for outdoor use. Always unroll a cable drum completely before use. Check the cable for damage.

  • Pull out the mains plug before all work on the product, in work breaks and when not in use.

  • Mains connection cables shall not have a smaller cross-section than rubber hose lines with the designation H05RN-F 3*0.75 mm². The cable length must be 10 m. The conductor core cross-section of the extension cable must be at least 1.5 mm2.

Lubricants are used inside the garden pump and domestic waterworks and can contaminate the drained fluids, if the product is improperly operated or damaged.

Warning! This electric tool generates an electromagnetic field during operation. This field can impair active or passive medical implants under certain conditions. In order to prevent the risk of serious or deadly injuries, we recommend that per-sons with medical implants consult with their physician and the manufacturer of the medical implant prior to operating the power tool.

Residual risks
The machine has been built according to the state-of-the-art and the recognized technical safety requirements. However, individual residual risks can arise during operation.

  • Health hazard due to electrical power, with the use of improper electrical connection cables.
  • Before performing setting or maintenance work, unplug the mains plug.
  • Furthermore, despite all precautions having been met, some non-obvious residual risks may still remain.
  • Residual risks can be minimized if the “Safety Instructions” and the “Intended Use” together with the operating manual as a whole are observed.

Technical data

  • AC motor…………………………………………………….. 230 V∼ 50 Hz

  • Nominal power S3*………………………………………….. 1300 watts

  • Max. delivery flow…………………………………………………5000 l/h

  • Max. delivery height…………………………………………………….50 m

  • Max. delivery pressure……………………………………………….. 5 bar

  • Max. suction height……………………………………………………….. 8 m

  • Pressure and suction connection……………………………………G 1”

  • Max. dirt particle size ………………………………………………0.5 mm

  • Max. water temperature …………………………………………… 35° C

  • Protection class …………………………………………………………………..I

  • Protection category………………………………………………………. IPX4

  • Operating mode*……………………………………………………………S3

  • Weight……………………………………………………………………….12 kg

  • Operating mode S3, periodic intermediate duty.

Noise
The noise values have been determined in accordance with EN 3744.

  • Sound power level LwA……………………………………………76 dB(A)
  • Uncertainty KpA/wA ………………………………………………………..1 dB

Warning: Noise can have serious effects on your health. If the machine noise exceeds 85 dB (A), please wear suitable hearing protection.

Before commissioning

  • Open the packaging and carefully remove the product.
  • Remove the packaging material, as well as the packaging and transport safety devices (if present).
  • Check whether the scope of delivery is complete.
  • Check the product and accessory parts for transport dam-age. In the event of complaints the carrier must be informed immediately. Later claims will not be recognized.
  • If possible, keep the packaging until the expiry of the warranty period.
  • Familiarize yourself with the product by means of the operating manual before using for the first time.
  • With accessories as well as wearing parts and replacement parts use only original parts. Replacement parts can be obtained from your dealer.
  • When ordering please provide our article number as well as type and year of manufacture for the product.

DANGER!
The device and the packaging are not children‘s toys! Do not let children play with plastic bags, films or small parts! There is a danger of choking or suffocating!

  • Prior to commissioning, all covers and safety devices must be mounted correctly.
  • Before connecting the machine, make certain that the data on the type plate matches with the mains power data.

Installation

NOTE!
The garden pump and domestic waterworks can also be in-stalled for domestic water supply indoors. To minimize vibrations and noises, the garden pump and domestic waterworks should be connected to the pipe network with flexible hoses. It is also recommended to use anti-vibration material, e.g. to put a rubber layer between the garden pump and domestic water-works and the machine base. Ensure that the pump is securely fastened using screws which fit through the screw brackets (7).

Note:
The connections for the suction and pressure connection have been set with 1 inch at the factory. Optionally, you can use the multifunctional adapter supplied, which offers further connection options (see point 9.1).
An additional connection system (such as a tap, hose clamp, bayonet fitting) is required for installation and is not included in the scope of delivery.

Function of the multifunction adapter (13) (fig. 15 + 15a)

  • Connection (a) 1 1/4” male thread
  • Connection (b) 1” male thread
  • Hose connection (c) 1” (hose clamp is required! Not included in the scope of delivery!)

Note:
To use connection (b), hose connection (c) must be cut off with a knife (not included in the scope of delivery) (see cutting mark in fig. 15)! After you have cut off the hose connection, it can no longer be used.

Attention! Risk of cuts!

Installing a suction line (fig. 1 + 15)

  1. Remove the locking screw (10a) on the suction connection (10). Keep the locking screw (10a) in a safe place (fig. 1)!
  2. Connect the appropriate connection system (e.g. quick coupling system, bayonet fitting) or the multifunction adapter (13) with the help of connection (a) to the suction connection (10).
  3. Then connect the suction line with the appropriate connection system (e.g. quick coupling system, bayonet fitting). If necessary, use connection (c) of the multifunction adapter (13).
  4. Lay the suction line from the water pick-up point to the gar-den pump and domestic waterworks in a continuously rising slope.

Notes:

  • Please do not lay the suction line above the pump height. Air bubbles in the suction line will delay and prevent the suction process.
  • Install the suction and pressure lines in order to avoid a mechanical pressure on the garden pump and domestic waterworks.
  • Place the suction line deep enough in the water to prevent the garden pump and domestic waterworks from running dry if the water level drops.
  • Check the suction hose for leaks, to avoid sucking air.
  • Avoid sucking in foreign bodies (sand etc.).

Filling the garden pump and domestic water- works with water (fig. 16)
In order to reduce the start-up time of the garden pump and domestic waterworks and to prevent air being sucked in, the garden pump and domestic waterworks must be filled with water beforehand!

  1. Therefore, the suction hose should be installed to prevent water from flowing out of the suction connection (10).

  2. Use the opening of the pressure connection (1) to fill the garden pump and domestic waterworks with water. Alter-natively, you can fill in water through the opening of the pre-filter locking screw (11).
    Approx. 2.5 litres of water are required.

  3. Slightly tilt the garden pump and domestic waterworks now and then, to avoid air being trapped. Alternatively, open the ventilation screw (8) and fill up with water until water comes out of it. Afterwards, attach the ventilation screw again.

  4. Now, attach the pressure line as described in the next point.

Installing a pressure line (fig. 1 and 2)

  1. Remove the locking screw (1a) from the pressure connection (1). Keep the locking screw (1a) in a safe place!
  2. Connect the appropriate connection system (e.g. quick coupling system, bayonet fitting) to the pressure connection (1) or the multifunction adapter (a or b).
  3. Then connect the pressure hose with the appropriate connection system (e.g. quick coupling system, bayonet fitting). If necessary, use connection c of the multifunction adapter (13).
  4. During the suction process, the consumers in the pressure line (e.g. nozzles, showers, toilet flush, etc.) must be fully opened so that the air in the suction line can escape freely.

Permanent installation of the garden pump and domestic waterworks (fig. 17)
For stationary use of the garden pump and domestic water-works, we recommend a permanent installation on a level sur-face.

  1. Only set up the garden pump and domestic waterworks on a screw able and flat surface.
  2. Install the garden pump and domestic waterworks on the fastening points (7). Use adequate assembly material for this (not included in the scope of delivery!).

Operation

Attention!
Always make sure the product is fully assembled before commissioning!

NOTE!
The garden pump and domestic waterworks must be absolutely tight at the inlet and outlet. Therefore, regardless of your chosen connection, use a Teflon or any other sealing tape.

LCD display
The garden pump and domestic waterworks offers a range of setting options. You can select one of the operating modes on the LCD display (3) with the “MODE” button (4).

Explanation of the display functions (fig. 3 – 14)

“Automatic Mode” (fig. 3 – 4.4)

  1. Connect the garden pump and domestic waterworks to the power supply The display shows “Power on” (fig. 3).

  2. Press the “MODE” button (4) one time to reach the “Automatic Mode” (fig. 4).
    Attention: Garden pump and domestic waterworks doesn’t immediately start Please ensure that the product is completely assembled.

  3. When you operate your consumer attached to the pressure line (e.g. nozzle, shower, toilet flush, etc.), the garden pump and domestic waterworks switches on. The water is pumped and the flow is marked on the display with the letter “L” (fig. 4.1).

  4. If the consumer is closed again, pressure builds up in the garden pump and domestic waterworks. The display shows “P L” (fig. 4.2).

  5. As soon as the maximum pressure is reached, the letter “L” disappears (fig. 4.3).

  6. The display then shows “Valve closed P” and the garden pump and domestic waterworks switches off (fig. 4.4).

  7. The garden pump and domestic waterworks starts again as soon as the consumer is opened again.

Safety switch (only available in automatic mode) (fig. 4.5)
NOTE!
In automatic mode, the garden pump and domestic waterworks has a safety switch to prevent it from running dry and causing the garden pump and domestic waterworks to malfunction.

  1. If the garden pump and domestic waterworks doesn’t recognize any flow “L” and any pressure “P”, it continues pumping for 60 seconds.
  2. After these 60 seconds, the garden pump and domestic waterworks switches off for 20 seconds.
  3. This process is repeated three times until the garden pump and domestic waterworks stops completely.
  4. The display now indicates that you need to check the water supply:” Automatic Mode – Check Water” (fig. 4.5).
    • Place the suction line deep enough in the water to pre-vent the garden pump and domestic waterworks from running dry if the water level drops.
    • Check the suction hose for leaks, to avoid sucking air.
    • Avoid sucking in foreign bodies (sand etc.).

Setting the time “Time Now”, the power-on time “Time On” and the power-off time “Time Off” (fig. 3, 5 – 13)

  1. Connect the garden pump and domestic waterworks to the power supply The display shows “Power on” (fig. 3).

  2. Press the “MODE” button (4) several times until “Time Mode” is displayed (fig. 5). After a brief waiting time, “Time Now” appears in the display (fig. 9).
    Note: After a while, the display shows “Time Mode NOT SET” if no time setting has been made (fig. 7).

  3.  Now press the “SET” button (5) to activate the time setting function (fig. 8).

  4. Then, set the current time using the “SET” button (5) for “+” and the “MODE” button (4) for “-” (fig. 9).
    You can change the settings for hours and minutes with the “CHECK” button (6).
    Note:00:00 (hh/mm)– 24h time mode.

  5. Confirm your settings with the “CHECK” button (6).

  6. To set the time when the garden pump and domestic waterworks is to switch on (“Time On” mode), press the “CHECK” button (6) again. (fig. 10)

  7. Now, repeat the steps 3 – 5, to set the power-on time and to confirm it.

  8. By pressing the “CHECK” button (6) again, the display will show the “Time Off” mode. In this mode you determine the time at which the garden pump and domestic waterworks should switch off (fig. 11).

  9. Now, repeat the steps 3 – 5, to set the automatic power-off time and to confirm it.

  10. The switch-on and switch-off times then appear in the dis-play “Time On / Time Off” (Fig. 12). It is not necessary to press the “CHECK” button (6) again.

  11. After a brief waiting time, “Time Mode” (fig. 13) appears on the display showing the time set.

“Always On Mode” continuous operation (fig. 14) (not recommended)
The garden pump and domestic waterworks can also be operated in continuous mode. In this mode there is no automatic safety switch and therefore the garden pump and domestic waterworks may only be operated under continuous observation!

  1. Connect the garden pump and domestic waterworks to the power supply The display shows “Power on” (fig. 3).

  2. Press the “MODE” button (4) one time to reach the “Al-ways On Mode” (fig. 14).
    Attention: Garden pump and domestic waterworks doesn’t immediately start Please ensure that the product is completely assembled.

  3. By pressing the “MODE” button (4) again, the garden pump and domestic waterworks switches off. The display shows “Power on” (fig. 3).

Uninstallation/Transport

Attention!
Always unplug the mains plug.
Empty the garden pump and domestic waterworks housing prior to transport.

  1. Provide a drip tray with a volume of approx. 5 liters (not included in the scope of delivery) for the water to be drained.
  2. Remove the water drain plug (9).
  3. Let the water completely flow out of the garden pump and domestic waterworks into the drip tray.
  4. Remove the suction and pressure hose.
  5. Remove the connection systems or multifunction adapters (13) attached to your garden pump and domestic water-works.
  6. If the garden pump and domestic waterworks is permanently installed, remove the assembly material.
  7. Afterwards tilt the garden pump and domestic waterworks until the residual water flows through the suction and pressure connection (10 and 1).
  8. Screw the water drain plug (9).
  9. Close the suction and pressure hoses (10 and 1) using the locking screws (1a and 10a) to protect the garden pump and domestic waterworks from dust and dirt.

Always use the transport handle (2) for transporting the product.

Maintenance

Attention!
Only carry out maintenance, cleaning and adjustment work when the mains plug is pulled out.
We recommend that you clean the product directly after every use. Clean the product at regular intervals using a damp cloth and a little soft soap. Do not use any cleaning products or solvents; they could attack the plastic parts of the product. Make sure that no water can penetrate the motor.

  • We recommend regular inspections and care for a long service life (i. e. at least once a month).
  • Before extended periods of inactivity or through the winter, the garden pump and domestic waterworks should be thoroughly flushed through with water, emptied completely and then stored dry.
  • To empty the housing, loosen the water drain screw (9) and tilt the garden pump and domestic waterworks slightly.
  • If there is a risk of frost the garden pump and domestic waterworks must be completely emptied.
  • After longer periods of storage check the pump by switching on/off briefly in order to check that the rotor turns normally.
  • In the event of the garden pump and domestic waterworks being jammed connect the pressure line to the water supply line and remove suction hose. Open the water supply line. Switch the garden pump and domestic waterworks on for ca. two seconds several times. This method rectifies block-ages in most cases.
  • To clean the pre-filter (12) unscrew the pre-filter locking screw (11) and remove it. Afterwards, clean it with clear water.

Connections and repairs
Connections and repair work on the electrical equipment may only be carried out by electricians.
Service information
With this product, it is necessary to note that the following parts are subject to natural or usage-related wear, or that the following parts are required as consumables.

*Wearing parts:** Seals, pre-filter, flow sensor impeller, non-return valve

  • may not be included in the scope of supply!
    Spare parts and accessories can be obtained from our Service Centre. To do this, scan the QR code on the front page.

Storage
Store the device and its accessories in a dark, dry and frost-free place that is inaccessible to children.
The optimum storage temperature is between 5 and 30˚C. Store the electric tool in its original packaging.
Cover the electric tool to protect it from dust or moisture. Store the operating manual with the electric tool.

Electrical connection
The electrical motor installed is connected and ready for operation. The connection complies with the applicable VDE and DIN provisions. The cus- tomer‘s mains connection as well as the extension cable used must also comply with these regulations.

Damaged electrical connection cable
The insulation on electrical connection cables is often dam-aged.
This may have the following causes:

  • Pressure points, where connection cables are passed through windows or doors.
  • Kinks where the connection cable has been improperly fastened or routed.
  • Places where the connection cables have been cut due to being driven over.
  • Insulation damage due to being ripped out of the wall outlet.
  • Cracks due to the insulation ageing.
    Such damaged electrical connection cables must not be used and are life- threatening due to the insulation damage. Check the electrical connection cables for damage regularly. Ensure that the connection cables are disconnected from elec-trical power when checking for damage.
    Electrical connection cables must comply with the applicable VDE and DIN provisions. Only use connection cables of the same designation.
    The printing of the type designation on the connection cable is mandatory.
    If the mains connection cable of this device is damaged, it must be replaced by a special connection cable which can be ob-tained from the manufacturer or its service department.

AC motor 230 V∼ / 50 Hz
Mains voltage 230 V∼ / 50 Hz.
Mains power connection and extension leads must be 3-core = P + N + SL. – (1/N/PE).

Extension cables up to 25 m long must have a cross-section of 1.5 mm². The mains power connection must be protected with a max. 16 A fuse.
Please provide the following information in the event of any enquiries:

  • Type of current for the motor
  • Engine data – type plate

Disposal and recycling

The device is supplied in packaging to avoid transport dam-ages. This packaging is raw material and can thus be used again or can be reintegrated into the raw material cycle.
The device and its accessories are made of different materials, such as metal and plastic. Take defective components to special waste disposal sites. Check with your specialist dealer or municipal administration!
The packaging is made of environmentally friend-ly materials that can be disposed of at your local recycling centre.
You can find out how to dispose of the disused de-vice from your local authority or city administration.

Do not throw old equipment away with household waste!

This symbol indicates that this product must not be dis-posed of in household waste as per Waste Electrical and Electronic Equipment directive (2012/19/EU) and national laws. This product must be handed over at the intended collection point. This can be done, for example, by returning it when purchasing a similar product or delivering it to an authorized collection point for the recycling of old electrical and electronic devices. Improper handling of old devices can have negative effects on the environment and on human health due to potential hazardous materials which are often contained in old electrical and electronic devices. By disposing of this product properly, you are also contributing to the effective use of natural resources. Information about collection points for old devices can be found at your municipal authority, the local disposal provider, an authorized location for the disposal of old electrical and electronic devices or your waste collection service.

Troubleshooting

Note: When returning the device for repair, please ensure for safety reasons that it is empty and dry when it is sent to the service centre.

PARKSIDE-PHGA-1300-House-and-Garden-Pump- \(37\) PARKSIDE-PHGA-1300-House-and-Garden-Pump-
\(38\)

Warranty certificate

Dear Customer,
All of our products undergo strict quality checks to ensure that they reach you in perfect condition. In the unlikely event that your device develops a fault, please contact our service department at the address shown on this guarantee card. Of course, if you would prefer to call us then we are also happy to offer our assistance under the service number printed below. Please note the following terms under which guarantee claims can be made:

  • These guarantee terms cover additional guarantee rights and do not affect your statutory warranty rights. We do not charge you for this guarantee.
  • Our guarantee only covers problems caused by material or manufacturing defects, and it is restricted to the rectification of these defects or replacement of the device. Please note that our devices have not been designed for use in commercial, trade or industrial applications. Consequently, the guarantee is invalidated if the equipment is used in commercial, trade or industrial applications or for other equivalent activities. The following are also excluded from our guarantee: compensation for transport damage, damage caused by failure to comply with the installation/assembly instructions or damage caused by unprofessional installation, failure to comply with the operating instructions (e.g. connection to the wrong mains voltage or current type), misuse or inappropriate use (such as overloading of the device or use of non-approved tools or accessories), failure to comply with the maintenance and safety regulations, ingress of foreign bodies into the device (e.g. sand, stones or dust), effects of force or external influences (e.g. damage caused by the device being dropped) and normal wear resulting from proper operation of the device.

The guarantee is rendered null and void if any attempt is made to tamper with the device.

  • The guarantee is valid for a period of 3 years starting from the purchase date of the device. Guarantee claims should be submitted be-fore the end of the guarantee period within two weeks of the defect being noticed. No guarantee claims will be accepted after the end of the guarantee period. The original guarantee period remains applicable to the device even if repairs are carried out or parts are re-placed. In such cases, the work performed or parts fitted will not result in an extension of the guarantee period, and no new guarantee will become active for the work performed or parts fitted. This also applies when an on-site service is used.
  • In order to assert your guarantee claim, please contact the service partner shown below. If the complaint is within the guarantee period, we will provide you with a return slip, with which you can return your defective device free of charge to us. It would help us if you could describe the nature of the problem in as much detail as possible. If the defect is covered by our guarantee then your device will either be repaired immediately and returned to you, or we will send you a new device.
    Of course, we are also happy offer a chargeable repair service for any defects which are not covered by the scope of this guarantee or for units which are no longer covered. To take advantage of this service, please send the device to our service address.

Service-Hotline (GB): 00800 4003 4003 (0,00 EUR/Min.)
Service-Email (GB): service.GB@scheppach.com
Service Address (GB): Forest Park & Garden Coed Court, Taffsmead Road
Treforest, Ind. Estate, Pontypridd CF375SW

Service-Hotline (IE):
00800 4003 4003
(0,00 EUR/Min.)
Service-Email (IE):
service.IE@scheppach.com

Service Address (IE):
LetMeRepair
1 Langlands Court / Kelvin South Business Park
East Kilbride G75 0YB

At www.lidl-service.com you can download this and many more manuals, product videos plus installation soft-ware.
The QR code takes you directly to the Lidl service page (www.lidl- service.com) and you can open your operating manual by entering the article number (IAN) 393888_2107.

PARTS

PARKSIDE-PHGA-1300-House-and-Garden-Pump-
\(34\)

SCHEPPACH GMBH
Günzburger Str. 69
D-89335 Ichenhausen
Last Information Update ·
Update: 12 / 2021 · Ident.-No.: 393888_2107_39094019915

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>