Progressive Industries EMS-HW30C Electrical Management System Instruction Manual

June 1, 2024
Progressive Industries

Progressive-Industries-LOGO

Progressive Industries EMS-HW30C Electrical Management System

Progressive-Industries-EMS-HW30C-Electrical-Management-System-
PRODUCT

Specifications

  • Model: EMS-HW30C & EMS-HW50C
  • Product Type: Electrical Management System
  • Recommended Installation by: Certified Electrician

CAUTION These instructions are intended to assist with the installation of this product, and are not a substitute for a more comprehensive understanding of electrical systems. We strongly recommend that a certified electrician install this product. Improper installation shall void the warranty.

Features

  • High/Low Voltage Protection : Whenever AC power falls below 104 volts or rises above 132 volts, the EMS automatically shuts down power to the RV. The EMS will monitor the power and once the AC power rises above 104 volts or drops below the 132 volt

  • level the time delay indicator flashes for the preset time and then automatically restores power to the RV.

  • Time Delay for A/C Compressor: If AC power is interrupted or the EMS detects a fault condition, the EMS unit will not pass power to the RV. If the faults are corrected, the built-in time delay is activated. There are two settings on the EMS: one is 136 seconds (02:16), and the other is 15 seconds. Consult your air conditioner manual to see if it has a time delay built in. If so, use the 15-second delay, if not, use the
    136- seconds delay. The factory setting is 15 seconds.

  • 3-Mode Surge Protection (EMS-HW30C): This feature provides full surge protection
    L- N, L-G, and N-G. The total Joule rating is 1,790J and 44,000A surge current. Response time <1 Nanosecond.

  • 5-Mode Surge Protection (EMS-HW50C): This feature provides full surge protection
    L- N, L-N, L-G, L-L, and N-G. Joule rating is 3,580J and 88,000A surge current. Response time <1 Nanosecond.

  • Surge Indicator: In the event of a power surge and the surge protector circuit
    is damaged within the EMS-L-N or L-G the digital error code will read E 10. This indicates the EMS needs to be serviced.

  • Reverse Polarity Protection : If AC power has a reverse polarity condition, the EMS will not allow power to the RV and the error code will read E 1.

  • Open Neutral Protection : If AC power has an open neutral, the display will not light and the EMS will not allow power to the RV.

  • Open Ground Protection: If AC power has an open ground condition, the EMS will read an error code of E 2, and power will not be allowed to the RV.

  • AC Frequency Protection: If AC power frequency deviates plus/minus 9 hertz from 60 cycles per second, the EMS will shut down AC power. An Error code of E 7 will be displayed when the frequency is high; and an Error code of E 8 will be displayed when the frequency is low.

  • Accidental 240V Protection: If 240 volts is detected when plugging into AC power the EMS will NOT allow power to the RV. If this condition occurs while power is applied to the RV, the EMS shuts off power instantly. The display will read the voltage and E 3 for the error. NEVER BYPASS THE EMS WHEN THIS OCCURS.

  • Remote Display: Continuously scrolls the AC power information, including voltage, current, frequency, error codes and previous errors. Each reading is displayed for two (2) seconds.

  • Previous Error Code : Previous error code (PE) indicates what error occurred and why power was interrupted. To delete the code, disconnect power from EMS.

  • ByPass: This switch is located on the remote display and allows the user to bypass the EMS in the event of failure, thus allowing AC power into the RV. This does not disable the surge protection portion of the EMS; however, all other features are disabled.

  • Modular Design: Replacement parts are designed for simple plug-and-play making repairs extremely user-friendly.

  • Microprocessor Controlled: The computer and remote display are driven by state-of-the-art microprocessors that are programmed with software to drive the entire EMS unit.

Warnings

  • RV wiring is different from house wiring; in an RV, neutral and ground conductors are isolated whereas in a house they are bonded at the service panel. Therefore; never connect neutral and ground. The result will cause a ground fault condition, electric shock, and/or a fire hazard. This does not stop you from using a “generator plug” that ties together neutral and ground as this is perfectly safe.
  • Do not exceed the rating on the EMS for any reason. These devices are designed to be reduced down to 120V/15A and maintain full protection.
  • Do not modify the EMS in any way as this will void the warranty, compromise protection and could result in possible shock, and/or a fire hazard.
  • It is important to always check the pedestal power outlet for charring; this condition means the AC receptacle is providing a weak connection. Should this condition exist, DO NOT USE as it could result in possible melting of the RV power plug.
  • Progressive Industries recommends you have a certified electrician install the EMS unit.
  • All AC power extension cords in conjunction with your EMS unit should be rated 10 gauge for 120V, 30A systems or 6 gauge for 240V, 50A systems and rated for outdoor use to reduce the risk of electrical shock. We recommend the length not to exceed 20-25’. Small gauge cables will have a higher resistance and can result in voltage loss or an electrical fire.
  • Whenever servicing or installing the EMS, or any other AC-powered device, make sure AC power is disconnected.
  • Never solder the ends of the wires you attach during installation, this includes any red, black and/or white wires.
  • Never plug the EMS into an inverter.

Installation Instructions Before Transfer Box
For installation, in addition to the EMS Kit, you will need:

  • 4 mounting screws.
  • In some cases, you will need a jumper cable, with length to be determined based on the placement of the EMS.
  • Always use 10 wires for the HW30C & #6 wire for the HW50C.
  1. Unplug the RV from AC power and be sure the generator is off.

  2. Determine a location for the EMS control box. Make sure to mount in a location with adequate airflow.

  3. Cut the RV power cord about three (3) inches greater than the distance from the junction box to the desired location of the EMS control box. Then strip back the outer insulation three (3) inches on the input, and three (3) inches on the output cable. See visual references on page 9.

  4. Strip back each conductor 3/8″ on both stripped ends of the input and output cables (see visual references on page 9). If stranded wire, attach ring terminals
    to green ground wires. If this green ground wire is solid, do not use ring terminals, and create a loop.

  5. Remove the lid from the EMS. Inside the unit will be a display, cable and pack of screws. Back off the six set screws from the top of the contactor (L1, L2, etc.).

  6. Take your input cable with the plug end and connect it to the input side by sliding the input wires and cable jacket through the wire restraint on the end of the EMS control box. Next, connect the wires to the contactor by attaching the black wire to L1, white to L2, red to L3, and green to the ground screw on the side of the box, either with a ring terminal or loop as noted in step 4. See visual references on page 9. Torque down set screws and ground nut to secure connections.

  7. Take the output cable coming from the junction box and slide it through the wire restraint output side of the EMS control box. Next, slide the black wire through the current sensor containing the green mark and connect it to T1, then connect the white wire to T2. Now slide the red wire through the other sensor and attach to T3. The current sensor(s) can be oriented in either direction. Attach the green ground wire to the ground screw on the side of the box, either with a ring terminal or loop as noted in step 4. See visual references on page 9. Make sure the wire colours match up adjacent to each other. Torque down set screws and ground nut to secure connections.

  8. Double-check all connections and make sure they are secure.

  9. Remove the two screws on the contactor where marked L1, L2, etc. Next, remove the top plastic plate with markings. Examine the inside ensuring there are no loose plastic pieces inside the contactor. If so, remove and re-install cover with two screws. See visual references on page 10. Do not over-tighten screws as this could break cover tabs.
    CAUTION If you break off a tab and do not remove it, this may stop the contactor from working and allow 240 volts in the RV.

  10. Secure cable ends by tightening down strain reliefs over the input and output wires. Do not over-tighten as this could cut through the insulation and cause
    a short.

  11. Set a time delay jumper on the circuit board. The factory setting is for 15 seconds. Remove the jumper to set for 136 seconds (02:16). See Features Section on time delay to determine which to use. See visual references on page 10.

  12. Plug in the remote display and cable (this cable is not a phone cable, but rather a data cable).
    NEVER PLUG IN THE DISPLAY WHILE RV POWER IS ON.

  13. Attach the EMS lid with the six black machine screws provided.

  14. Mount the EMS control box.

  15. Installation is complete. Next, plug in and follow the operating instructions.

Installation After Transfer Box for Protection from both Generator and AC Power

For installation, in addition to the EMS Kit, you will need

  • 4 mounting screws.
  • In some cases, you will need a jumper cable, with length to be determined based on the placement of the EMS.
  • Always use 10 wires for the HW30C & #6 wire for the HW50C.
  1. Unplug the RV from the AC power and be sure the generator is off.

  2. Locate the transfer switch box; determine where the EMS control box will be mounted.

  3. Measure the distance between the transfer switch and the control box and add one (1) foot. This is the length of cable that will be required for the installation. Make sure 6-gauge, 4 conductor cables are used.

  4. Remove the lid from the transfer box, disconnect and remove the output cable.

  5. Take the jumper cable and strip back one end three (3) inches and the other end the same as the end removed from the transfer box. The cable removed from the transfer box must have at least three (3) inches of the outer insulation removed. See visual references on page 10.

  6. Strip back each conductor 3/8″. See visual references on page 9. If stranded wire, attach a ring terminal to the green ground wire. If this green ground wire is solid, do not use a ring terminal, and create a loop.

  7. Remove the lid from the unit. Inside the unit will be a digital display, cable and pack of screws. Back off the six set screws from the top of the contactor (L1, L2, etc.).

  8. Take the jumper cable and connect it to the input side by sliding through the wire restraint on the end of the EMS control box and then connect the black wire to L1; white to L2; red to L3, and green to the ground screw. See visual references on page 10. Torque down set screws and ground nut to secure connections.

  9. The cable that came from the transfer box connects to the output side of the EMS control box in the same manner. Next slide the black wire through the current sensor containing the green mark connect to T1 and then connect the white wire to T2. Now slide the red wire through the other current sensor and attach
    to T3. Next, attach the green ground wire to the ground screw on the side of the box. See visual references on page 10. Make sure the conductor’s colours match up with each other. Torque down the set screws and ground nut to secure connections.

  10. Connect the loose end of the jumper cable to the transfer switch. See the wiring diagram on the transfer switch if needed.

  11. Double-check all connections to ensure they are secure.

  12. Remove the two screws on the contactor where marked L1, L2, etc. Next, remove the top plastic plate with markings. Examine the inside ensuring there are no loose plastic pieces inside the contactor. If so, remove and re-install cover with two screws. See visual references on page 10.

  13. Secure cable ends by tightening down strain reliefs over the input and output wires. Do not over-tighten as this could bite through insulation and cause a short.

  14. Set a time delay jumper on the circuit board. The factory setting is for 15 seconds. Remove the jumper to change the setting to 136 seconds (02:16). See Features Section on time delay to determine which to use. See visual references on page 10.

  15. Plug-in digital remote and data cable (this cable is not a phone cable, but rather a data cable.)
    NEVER PLUG IN THE DISPLAY WHILE RV POWER IS ON.

  16. Attach lid with the six black machine screws provided and attach the transfer switch lid.

  17. Mount the EMS control box.

Operating Instructions

  1. Plug into A/C power.
  2. The digital display will momentarily show 888 and then begin scrolling the voltage, amps, line frequency and error code, if any. In addition, the time delay light (bottom right-hand corner) will flash while the EMS is going through its initial 6-second countdown and will stop when the unit engages. If the delay light does not flash, a fault condition is present. Refer to the Error Code Chart (pages 7-8) to determine the problem with the AC power.
  3. You may notice when first plugging in, the display may read E 9. This indicates the display has not received the data from the computer yet. Do not be alarmed, this is normal. By the next scroll through, it should read E 0 if the AC power is normal.
  4. The digital display will give you a three-digit number indicating your line voltage. Next, it will give you an “OA” reading indicating the current (amps). The current (amps) will read zero until the initial 6-second time delay is complete. The output power will remain off until the time delay is finished. After the output power is on, the unit will indicate a number between 0 and 50 which indicates how many amps the RV is drawing. The next number indicates your line frequency. This number should be “60H” and should remain fairly consistent; however, it may read plus/minus one or two. Lastly, note the E code. E 0 is normal and only when E 0 or E 10 is present will the delay light flash for 6 seconds and then allow power to the RV. Refer to the Error Code Chart card that was provided with your unit or see the Error Code Chart (pages 7-8) for additional information.
  5. Set up will be complete when the Error Code E 0 is displayed.
    NOTE : If the display reads anything different than correct (E 0), the EMS will not turn on and we recommend you move to a different source of AC power or use your generator power. Also, if power is below 104 volts or above 132 volts, the EMS will not turn on, and we recommend using your generator power.

Display Code Chart

  • L1 – Line 1
  • XXX – Line 1 Voltage
  • XXA – Line 1 Amps
  • L2 – Line 2
  • XXX – Line 2 Voltage
  • XXA – Line 2 Amps
  • XXH – Frequency in Hertz (Hz)
  • E X – Error Code
  • PE X – Previous Error Code that has been corrected (If Applicable).

Error Code Chart

  • E 0 – Normal Operating Condition
  • E 1 – Reverse Polarity (hot and neutral wires reversed)
  • E 2 – Open Ground (no ground wire connection)
  • E 3 – Line 1 High Voltage (line voltage above 132V)
  • E 4 – Line 1 Low Voltage (line voltage below 104V)
  • *E 5-** Line 2 Voltage High (Line voltage above 132V)
  • **E 6*** – Line 2 Voltage Low (Line voltage below 104V)
  • E 7 – Line Frequency High (line frequency above 69Hz)
  • E 8 – Line Frequency Low (line frequency below 51Hz)
  • E 9 – Data Link Down (call technical support)
  • E 10 – Replace Surge Protector Module (call Progressive Industries Tech Support)
    Code only applies to EMS-HW50C models

Note : PE is a previous error code that HAS BEEN RECTIFIED.
If the EMS cuts the power to the RV it will show a PE code following the E code. This denotes the previous error or why the EMS shut down. Example: The EMS cuts power for low voltage on Line 1, and then the power is restored. The Error Code reads
E0, but the PE code reads PE 4 which tells the user that low voltage was the reason for the EMS previously cutting power. This PE error code will be deleted when power is disconnected from the EMS.

Accidental 240 volt Protection: Should this condition occur, the display will read 240 volts instead of displaying the voltage and the error code message will read E3. AC power will shut down instantly. DO NOT UNDER ANY CIRCUMSTANCES BYPASS THE EMS AS THIS WILL RESULT IN SEVERE DAMAGE TO THE RV.

Troubleshooting

Common installation mistakes:

  1. Check connections.
    HW50C : Input is the plug side of the RV and black should be attached to L1, white to L2 and red to L3. Output (going to the RV) should match up. T1 black, T2 white and T3 red. The green ground gets attached to the input and output on the side of the box.
    HW30C : Input is the plug side of the RV and black should be attached to L1, white to L2. Output (going to the RV) should match up. T1 is black, T2 is white. The green ground gets attached to the input and output on the side of the box.

  2. Make sure the input wires are, in fact, the input wires. Connecting the output to the input of the EMS will cause the device to malfunction.

  3. If the EMS is still not functioning at this point, follow the instructions below before calling Progressive Industries Technical Support.

For the on-call Technician to help troubleshoot the problem(s) you are experiencing and render the best possible solution, you must be at your RV when you place your call. If the display is illuminated and scrolling information, note the Error Code. If there is an Error code of 1-9, the device will interrupt the power. See the Error Code Chart for the definition of AC power problem. The device being off when an Error Code is present indicates the product is working properly and protecting your coach.

  1. If the display is illuminated and reading Error code E 0, and yet no power is present in the coach, please contact Progressive Industries Tech Support. You must wait for the time delay light to stop flashing.
  2. If the display is not illuminated and power is on inside the coach there is a connection issue between the display and the main control box. Contact Technical Support.

Our Tech Support Team can only assist you if the above information is provided; therefore, you must be at the RV when you place your call. To recap…

  1. Are the connections correct?
  2. What is the Error Code message being displayed?
  3. Is the delay indicator flashing?

Visual References

Photo Library for the EMS-HW50C

Progressive-Industries-EMS-HW30C-Electrical-Management-System-
FIG-3Progressive-Industries-EMS-
HW30C-Electrical-Management-System-FIG-4

Wiring Diagram for EMS-HW30C

Wiring Diagram for EMS-HW50C

Progressive Industries, Inc.
For more information regarding the Limited Lifetime Warranty, Troubleshooting and the Warranty Claim Form visit: www.progressiveindustries.net

Technical Support

FAQ

  • Q: Can I install the EMS myself?
    • A: While it is possible to install the EMS yourself, it is highly recommended to hire a certified electrician to ensure proper installation and avoid warranty issues.
  • Q: How do I know if the EMS is working correctly?
    • A: The LED display on the EMS will show voltage and current readings. If there are any issues, the EMS will automatically shut down to protect your RV or camper.

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals