DOMETIC H30R 30L Dehumidifier Instruction Manual

June 3, 2024
Dometic

DOMETIC H30R 30L Dehumidifier

H30R 30L Dehumidifier
Instruction Manual

SAFETY WARNING

For your safety, please read the following contents carefully before using this dehumidifier:
Requirements:

  • Install this humidifier in smooth place to reduce vibration and noise.

  • Do not place this dehumidifier in water or other liquids.

  • In order to prevent accidents, please do not use this dehumidifier if wires or other connections are damaged.

  • This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved.
    Children shall not play with the appliance.cleaning and user maintenance shall not be made by children without supervision.

  • When stop, reset or clean this dehumidifier, please cut off the power.

  • Please use at the specified voltage.

  • This dehumidifier can only be used indoor, please do not use for other purposes.

  • Please do not place heavy objects on this dehumidifier.

  • Please empty water tank to prevent overflow and spill before restarting this dehumidifier.

  • Please do not incline in case that the spilled water damages this dehumidifier.

  • Please do not place waste rods and hard objects into the dehumidifier in case that error and damage occur.

  • If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.

  • When this dehumidifier is not used for long time, please unplug the electric cord.

  • Power supply of the Dehumidifier shall comply with the safety regulations where it is used and ensure reliable grounding.

Prohibition:

  • Please do not place this dehumidifier close to heating devices (flame or heaters,  etc.).
  • Please do not turn on or turn off this dehumidifier by plugging in or pulling out the plug.
  • Do not use insecticide spray or other flammable substances in the vicinity of this dehumidifier.
  • Do not scratch appearance of this dehumidifier with sharp matters.
  • Do not splash oil or water into this dehumidifier.
  • Do not clean this dehumidifier with water, please wipe it with subhumid soft cloth.
  • Do not wipe this dehumidifier with chemical solvents such as benzene, gasoline and alcohol, etc. If this dehumidifier is indeed dirty, please wipe with neutral detergent.
  • Please do not incline this dehumidifier over 45°or place this dehumidifier upside down.

FREQUENT ENQUIRIES

Q: Why is less water stored in water tank of the dehumidifier in winter?

– In winter temperature is low and air is dry. In comparison with summer, the dehumidification ability of the dehumidifier decreases remarkably, this is not a fault.

Q: Why the dehumidifier cannot run or stops running suddenly?

– This dehumidifier may be full of water or water tank is not installed properly, drain the water in water tank, or re-install water tank in correct way.
– At the moment the dehumidifier may be in the ” dehumidification mode”, the ambient temperature is lower or higher ( dehumidification cannot be performed) when the ambient temperature is< 5° C or >32° 0 ).
– The ambient temperature for operation of the dehumidifier is – , and the relative humidity is 30%-80%. The optimal temperature for use is 61-90F;

Q: Why is hot air blown out from air supply outlet?

– This dehumidifier extracts the air in the room, and the dehumidification unit cools the air, the temperature decreases below the condensation point, the air condenses into water drops, which falls into water tank finally, and the dehumidified air is heated by the temperature returning unit. This can reduce energy consumption and also accelerate dehumidification, therefore, hot air is blown out, and this not a fault.

INSTALLATION

  • Please drain the water from water tank before running.
  • During running please do not open doors and windows as much as possible since this can save energy resources.
  • When the dehumidifier is installed, a certain space must be reserved around this dehumidifier, the minimum distance above is 19.7in. and the minimum distance in front/rear and left/right is 7.9in. as required, as shown in figure below.
  • When big noise is found during operation of this dehumidifier:
    It is recommended inserting pads or damping rubber sheets, etc. below this dehumidifier, this can reduce vibration and noise, and can also reduce sinking of wood floor or carpet.DOMETIC H30R 30L Dehumidifier - Figure
1

COMPONENTS

DOMETIC H30R 30L Dehumidifier - Figure 2

DOMETIC H30R 30L Dehumidifier - Figure 3

Front side Back side

CONTROL PANEL

DOMETIC H30R 30L Dehumidifier - Figure 4

Timer
24h timer setup, press this key to set on/off time of the dehumidifier, and the setting range is 1-24h. If you cancel timer setup, press twice continuously after confirmation of setting time.
Dry key in dehumidifier
Press this key start drying procedure in the dehumidifier. Press the key for 3 seconds to start the ionizer and press the key for 3 seconds again to cancel ionizer.
Air speed
In AUTO or CONTINUOUS mode air speed, HIGH and LOW can be circularly selected. LED Display
In AUTO and CONTINUOUS modes, the figure represents room humidity. When humidity is set in AUTO mode, this figure shows the set humidity; and displays the set time in timer state,% represents percentage of humidity.
Humidity setting
Once this key is pressed, the humidity is displayed circularly in the range of 30%-35%-40%-45%-50%-55%-60%-65%- 70%- 75%-80%, and the humidity setting is only valid in AUTO mode.
Mode
During startup or timer startup press this key to select AUTO or CONTINUOUS, and the indicator lamp corresponding to the selected mode is on. Press this button 3s, the child lock function starts. Re-press 3s, cancel the function.
On/off key Press this key to turn on or tum off the dehumidifier.

OPERATING METHODS

Description of functions
Setting of timer off

  • When the dehumidifier is running, press the [Timer key] to adjust time from 1h to 24h, pressing the key once to increase the setting time by 1h, after the setting time exceeds 24h, the figure returns to 1to start cycle. The Timer key can also be pressed all the time, the time increases and changes circularly, when the set time expires, the dehumidifier turns off automatically. After the setting is completed, if the Timer key does not act at all within 5s, the set time is confirmed. In timer off state the key lamp on the [Timer key] is normally on.

Setting of timer on

  • When the dehumidifier is in standby state, the method for adjustment of setting time by the [Timer key] is the same as timer off. After the setting is completed, if the Timer key does not act at all within 5s, the set time is confirmed. In timer on state the key lamp on the [Timer key] is normally on, and the set time is displayed on controlpanel.

AUTO mode

  • Select AUTO dehumidification
    If the room humidity is higher than the set humidity or is between +5% or -5% of the set humidity, the compressor will start and the fan will run at the set speed. If the room humidity is lower than the set humidity by -5%, the compressor and fan motor will stop. (The default set humidity value is 50%).

CONTINUOUS mode

  • Select CONTINUOUS dehumidification, no matter how the relative humidity in the room is, the compressor starts, the fan runs at high speed in default, and the air speed can be regulated via the air speedkey.

DRYING function in dehumidifier

  • Press the Drying key in dehumidifier to start drying in the duhumidifier to prevent inner unit mildew .

DRAINAGE

Use of water tank
When the water tank is full of water, the full water icon on LED flashes (the compressor, fan and negative ion will stop running), the BUZZER sounds for 10 times to remind the user till water is drained.

  • Place both hands respectively at the side of the back cover side of the depression, gently remove the water tank and open the tank cover on the right side of the body, then pour the water from the gap between water tank and the cover.
  • Close the tank cover, and rotating water tank handle down,then put the water tank gently and put it back in the right place to restart dehumidifier.

Attention: when the water tank is full of water, please empty it. Before putting the water tank into the dehumidifier, please confirm whether the floater rotates flexibly or not, and then push it in position with both hands.

CONTINUOUS DRAINAGE

If you do not want to drain water in the water tank frequently, you can connect a drainage pipe on the back of this dehumidifier to drain water. Two kind of pipe is optional. One is inner diameter 9mm ,which provided by manufacturer. Another is standard screw thread garden drain pipe with outer diameter of 1 1/16 inches and the pitch of 11.5TPI

  • Find the position where the water outlet is blocked on the back, as shown in figure below:
  • Pull down the water plug and connect drain pipe like following figure l(provided pipe connect) or figure 2( arden drain pipe connect).DOMETIC H30R 30L Dehumidifier - Figure 9

Attention: the level height of externally connected water pipe shall not be higher than the water outlet, and the water pipe at rear-end shall transit smoothly, otherwise, the leakage risk exists since drainage is not smooth.

MAINTENANCE

Precautions:

  • Please disconnect power supply before maintenance or repair to prevent electric shock.
  • If the dehumidifier is not used for long time, please disconnect power supply.
  • Please do not clean the dehumidifier body with chemical solvents such as alcohol, gasoline and benzene, etc.,
  • Please clean the water tank and its cover with soft cloth dipped in cold or warm water at regular time to prevent mould inside the dehumidifier.
  • Wipe the surface of the dehumidifier slightly with wet cloth, and do not use detergent or abrasive in case the plastic surface is damaged.DOMETIC H30R 30L Dehumidifier - Figure 11
  • Clean the washable PP strainer at lease once per two weeks simply with cold or warm water, do not use chemical solvents or hot water.

TROUBLESHOOTING

If the following problems occur to the dehumidifier, the following solutions can be adopted.

Symptoms Possible reasons Solutions
The dehumidifier does not run Does power plug fall? Insert power plug into

socket.
Is the water tank full of water? (the water tank is full of water or is placed at incorrect position)| Drain water from the water tank, and then install the water tank again.
The ambient temperature is lower than 41°F or higher than 90°F| Normal phenomenon
The dehumidification function is not effective| Is the room temperature or humidity too low?| In dry season the dehumidification ability will reduce.
Are the air outlet and inlet blocked?| Clean up the objects blocking the air outlet and inlet.
Air is not blown out| Is the air strainer blocked?| Clean the air strainer according to the above method.
Noise is abnormal during operation| Is the dehumidifier placed improperly so that it is inclined or unstable?| Please place the dehumidifier in smooth place.
Is the air strainer blocked?| Clean the air strainer according to the above method.
There is “tittering” sound| The flowing sound of refrigerant, which is a normal phenomenon.
Water leaks| Connection of drainage pipe becomes loose| Fasten drainage pipe.
Drainage system is blocked| Remove obstacles and straighten out water pipe.
Frosting occurs| The ambient temperature is low, and it is in the state waiting for defrost| It is a normal phenomenon, and the dehumidifier has the automatic defrosting function.
Display code| Instrustion
---|---
FL| The water tank is full
E1| The coil sensor detects anomaly
E2| The room temperature sensor detects anomaly
P1| The unit is in the defrosting state,normal
CL| The unit is in the internal drying state,normal
LC| Child lock funtcion starts

TECHNICAL PARAMETERS

Model H30R
Operating voltage 220-240V/50Hz
Dehumidification ability 30L/day@30° C 80%RH

18L/[email protected]° C 80%RH
Rated power| 295W
Capacity of water tank| 3.6L
Net Weight| 13.5kg
Dimensions (in) (HxWxD)| 512343240mm
Degree of protection| IPXl

All data are for reference only, and are modified for improvement of product functions or technology without notice.

DISPOSAL

Meaning of crossed – out wheeled dustbin: Do not dispose of electrical appliances as unsorted municipal waste use separate collection facilities. Contact your local government for information regarding the collection systems available. If electrical appliances are disposed of lin landfills or dumps, hazardous substances can leak into the ground water and get into the food chain, damaging your health and well-being. When replacing old appliance with new ones, the retailer is legally obligated to take back your old appliance for disposal.

AUSTRIA
Dometic Austria GmbH
Neudorferstraße 108
A-2353 Guntramsdorf
+43 2236 908070
** +43 2236 90807060
Mail: [email protected]
BRAZIL
Dometic DO Brasil LTDA
Avenida Paulista 1754, conj. 111
SP 01310-920 Sao Paulo
+55 11 3251 3352
**
+55 11 3251 3362
Mail: [email protected]
SPAIN
Dometic Spain S.L.
Avda. Sierra del Guadarrama, 16
E-28691 Villanueva de la Cañada
Madrid
+34 902 111 042
** +34 900 100 245
Mail: [email protected]
FINLAND
Dometic Finland OY
Mestarintie 4
FIN-01730 Vantaa
+358 20 7413220
**
+358 9 7593700
Mail: info@dometic.fi
POLAND
Dometic Poland Sp. z o.o.
Ul. Puławska 435A
PL-02-801 Warszawa
+48 22 414 3200
 +48 22 414 3201
Mail: [email protected]
UNITED KINGDOM
Dometic UK Ltd.
Dometic House, The Brewery
Blandford St. Mary
Dorset DT11 9LS
+44 344 626 0133
** +44 344 626 0143
Mail: [email protected]
HUNGARY
Dometic Zrt. Sales Office
Kerékgyártó u. 5.
H-1147 Budapest
+36 1 468 4400
**
+36 1 468 4401
Mail: [email protected]| JAPAN
Dometic KK
Maekawa-Shibaura, Bldg. 2
2-13-9 Shibaura Minato-ku
Tokyo 108-0023
+81 3 5445 3333
** +81 3 5445 3339
Mail: [email protected]
NETHERLANDS
Dometic Benelux B.V.
Ecustraat 3
NL-4879 NP Etten-Leur
+31 76 5029000
**
+31 76 5029019
Mail: [email protected]
DENMARK
Dometic Denmark A/S
Nordensvej 15, Taulov
DK-7000 Fredericia
+45 75585966
** +45 75586307
Mail: [email protected]
NORWAY
Dometic Norway AS
Østerøyveien 46
N-3232 Sandefjord
+47 33428450
**
+47 33428459
Mail:[email protected]
UNITED ARAB EMIRATES
Dometic Middle East FZCO
P. O. Box 17860
S-D 6, Jebel Ali Freezone
Dubai
+971 4 883 3858
** +971 4 883 3868
Mail: [email protected]
HONG KONG
Dometic Asia Co., Limited
Suites 1202-1207, 12/F, Tower One,
Grand Century Place, 193 Prince Edward
Road West, Mongkok, Kowloon, Hong Kong
+852 24565199
**
+852 24665553
Mail: [email protected]| SLOVAKIA
Dometic Slovakia s.r.o. Sales Office Bratislava
Nádražná 34/A
900 28 Ivanka pri Dunaji
**/ +421 2 45 529 680
Mail: [email protected]
MEXICO
Dometic Mx, S. de R. L. de C. V.
Circuito Médicos No. 6 Local 1 Colonia
Ciudad Satélite
CP 53100 Naucalpan de Juárez Estado
de México
+52 55 5374 4108
**
+52 55 5393 4683
Mail: [email protected]
NEW ZEALAND
Dometic New Zealand Ltd.
PO Box 12011
Penrose
Auckland 1642
+64 9 622 1490
** +64 9 622 1573
Mail: [email protected]
SWITZERLAND
Dometic Switzerland AG
Riedackerstrasse 7a
CH-8153 Rümlang
+41 44 8187171
**
+41 44 8187191
Mail: [email protected]
GERMANY
Dometic WAECO International GmbH
Hollefeldstraße 63
D-48282 Emsdetten
+49 (0) 2572 879-195
** +49 (0) 2572 879-322
Mail: [email protected]
RUSSIA
Dometic RUS LLC
Komsomolskaya square 6-1
RU-107140 Moscow
+7 495 780 79 39
**
+7495 916 56 53
Mail: [email protected]
ITALY
Dometic Italy S.r.l.
Via Virgilio, 3
I-47122 Forlì (FC)
+39 0543 754901
** +39 0543 754983
Mail: [email protected]| BENELUX
Dometic Branch Office Belgium
Zincstraat 3
B-1500 Halle
+32 2 3598040
**
+32 2 3598050
Mail: [email protected]
SOUTH AFRICA
Dometic (Pty) Ltd.
Regional Office
South Africa & Sub-Saharan Africa
Unit 6-7 on Mastiff Linbro Park
2008 Johannesburg
+27 11 4504978
** +27 11 4504976
Mail: [email protected]
SWEDEN
Dometic Scandinavia AB
Gustaf Melins gata 7
S-42131 Västra Frölunda
+46 31 7341100
**
+46 31 7341101
Mail: [email protected]
FRANCE
Dometic SAS
ZA du Pré de la Dame Jeanne B.P. 5
F-60128 Plailly
+33 3 44633525
** +33 3 44633518
Mail : [email protected]
PORTUGAL
Dometic Spain, S.L.
Branch Office em Portugal
Rot. de São Gonçalo nº 1 – Esc. 12
2775-399 Carcavelos
+351 219 244 173
**
+351 219 243 206
Mail: [email protected]
USA
Dometic RV Division
1120 North Main Street
Elkhart, IN 46515
+1 574-264-2131
SINGAPORE
Dometic Pte Ltd
18 Boon Lay Way 06–140 Trade Hub 21
Singapore 609966
+65 6795 3177
** +65 6862 6620
Mail:** [email protected]
---|---|---|---

dometic.com
HONG KONG
Dometic Asia Co., Limited
Suites 1202-1207, 12/F, Tower One, Grand
Century Place, 193 Prince Edward Road West,
Mongkok, Kowloon, Hong Kong
+852 24565199
** +852 24665553
Mail: [email protected]
RE220208**

Documents / Resources

| DOMETIC H30R 30L Dehumidifier [pdf] Instruction Manual
H30R, 30L Dehumidifier, H30R 30L Dehumidifier, Dehumidifier
---|---

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Dometic User Manuals

Related Manuals