Product Information
- Model: PLA-A12EA7
- Cooling Capacity: 12,000 BTU/H
- Heating Capacity: 14,000 BTU/H
- Unit Type: Ceiling Cassette
- Voltage, Phase, Frequency: 208/230V AC, 1 phase, 60Hz
- Guaranteed Voltage Range: 198-253V AC
- Short-circuit Current Rating [SCCR]: MCA
- Fan Motor Full Load Amperage: A
- Airflow Rate at Cooling, Dry: CFM
- Airflow Rate at Cooling, Wet: CFM
- Airflow Rate at Heating, Dry: CFM
- Sound Pressure Level [Cooling]: dB[A]
- Sound Pressure Level [Heating]: dB[A]
- Drain Pipe Size: In. [mm]
- Condensate Lift Mechanism, Maximum Distance: In. [mm]
- Coating on Heat Exchanger: White Munsell 6.4Y 8.9/0.4
- External Finish Color: White
- Unit Dimensions (W x D x H): 33-1/16 // 37-13/32 x 33-1/16 // 37-13/32 x 10-5/32 // 1-9/16 [840 // 950 x 840 // 950 x 258 // 40] (inches // mm)
- Unit Weight: Lbs. [kg]
- Package Dimensions (W x D x H): 35-9/16 // 39-6/16 x 34-5/16 // 38-3/16 x 15 // 4-12/16 [903 // 1,000 x 871 // 970 x 381 // 121] (inches // mm)
- Package Weight: Lbs. [kg]
- Gas Pipe Size O.D. [Flared]: 1/2 [12.7] inches [mm]
- Liquid Pipe Size O.D. [Flared]: 1/4 [6.35] inches [mm] –
- Refrigerant: R410A
Product Usage Instructions
- Before installation, ensure that the electrical wire is slacked a little bit.
- Install the indoor unit in the ceiling at a height of 118-1/8 inches (3000mm) or more, with a clearance of 70-7/8 inches (1800mm) or more from the floor.
- Connect the indoor unit to the outdoor unit using the provided connecting terminal block.
- Make sure to use self-tap screws in four places to connect the indoor unit to the branch duct.
- Install the optional accessories like control interface, remote sensor, and wired remote controller (PAC-SF40RM-E).
- Ensure proper ventilation by providing fresh air intake holes and air outlet holes in the ceiling.
- Follow the specified ceiling grille dimensions for proper installation.
- Connect the remote controller wire to the designated entry points.
- For detailed installation instructions, refer to the user manual.
Note: The product specifications are subject to change without notice.
GENERAL FEATURES
- Space-efficient ductless installation
- Equipped with 3D i-see Sensor® for enhanced comfort and energy efficiency
- Airflow settings for high and low ceiling applications
- Individual vane settings for direct/indirect airflow control or variable airflow patterns
- Knockouts for outside-air intake and branch-duct run
- Filter indicator signal
- Easy-to-clean, washable filter (optional high-efficiency filter available -requires multi-function casement)
- Built-in condensate lift mechanism
- Ideal for retail shops, classrooms, office spaces, conference centers, building lobbies, and more
- Multiple control options available:
- kumo cloud® smart device app for remote access
- Third-party interface options
- Wired or wireless controllers
Specifications | System |
---|---|
Unit Type | PLA-A12EA7 |
Cooling Capacity1, 3 | BTU/H |
Heating Capacity2, 3 | BTU/H |
Electrical
| Voltage, Phase, Frequency| 208/230, 1, 60
Guaranteed Voltage Range| V AC| 198- 253V
Voltage: Indoor – Outdoor, S1-S2| V AC| 208/230
Voltage: Indoor – Outdoor, S2-S3| V DC| 24
Short-circuit Current Rating [SCCR]| kA| 5
Indoor Unit| MCA| A| 1.0
Fan Motor Full Load Amperage| A| 0.26
Airflow Rate at Cooling, Dry| CFM| 420–460–490–530
Airflow Rate at Cooling, Wet| CFM| 380–420–450–490
Airflow Rate at Heating, Dry| CFM| 420–460–490–530
Sound Pressure Level [Cooling]| dB[A]| 27–28–29–30
Sound Pressure Level [Heating]| dB[A]| 27–28–29–30
Drain Pipe Size| In. [mm]| 1-1/4 [32]
Condensate Lift Mechanism, Maximum Distance| In. [mm]| 33-7/16 [849]
Coating on Heat Exchanger| —
External Finish Color| White Munsell 6.4Y 8.9/0.4
Unit Dimensions| W x D x H: In. [mm]| 33-1/16 // 37-13/32 x 33-1/16 //
37-13/32 x 10-5/32 // 1-9/16 [840 // 950 x 840 // 950 x 258 // 40]
Package Dimensions| W x D x H: In. [mm]| 35-9/16 // 39-6/16 x 34-5/16 //
38-3/16 x 15 // 4-12/16 [903 // 1,000 x 871 // 970 x 381 // 121]
Unit Weight| Lbs. [kg]| 46 // 11 [21 // 5]
Package Weight| Lbs. [kg]| 68 [31]
Refrigerant| Type| R410A
Piping
| Gas Pipe Size O.D. [Flared]| In.[mm]| 1/2 [12.7]
Liquid Pipe Size O.D. [Flared]| In.[mm]| 1/4 [6.35]
NOTES: 1 Cooling (Indoor // Outdoor) °F 80 DB, 67 WB // 95 DB, 75 WB
Conditions: 2 Heating at 47°F (Indoor // Outdoor) °F 70 DB, 60 WB // 47
DB, 43 WB
3Capacity varies based on the number of indoor units operating and the model of the Multi-zone Outdoor Unit. For reference to connected capacity charts, please refer Multi-zone Outdoor Unit Operational Performance.:
INDOOR UNIT ACCESSORIES: PLA-A12EA7
Control Interface | 3-Pin Connector | □ PAC-715AD |
---|---|---|
BACnet® and Modbus® Interface | □ PAC-UKPRC001-CN-1 | |
CN24 Relay Kit | □ CN24RELAY-KIT-CM3 | |
IT Extender | □ PAC-WHS01IE-E | |
kumo station® for kumo cloud® | □ PAC-WHS01HC-E | |
Lockdown bracket for remote controller | □ RCMKP1CB | |
Remote Operation Adapter‡ | □ PAC-SF40RM-E | |
Thermostat Interface | □ PAC-US444CN-1 | |
Thermostat Interface | □ PAC-US445CN-1 | |
USNAP Adapter | □ PAC-WHS01UP-E | |
Wireless Interface for kumo cloud® | □ PAC-USWHS002-WF-2 | |
Remote Sensor | Flush Mount Remote Temperature Sensor | □ PAC-USSEN002-FM-1 |
Flush Mount Temperature Sensor | □ PAC-USSEN001-FM-1 | |
Remote Temperature Sensor | □ PAC-SE41TS-E | |
Wireless temperature and humitity sensor for kumo cloud® | □ PAC-USWHS003-TH-1 | |
Wired Remote Controller | Airzone ZBS Wired Blueface Principal Controller | |
White | □ AZZBSBLUEFACECB | |
Airzone ZBS Wired Lite Controller White | □ AZZBSLITECB | |
Airzone ZBS Wired Think Controller White | □ AZZBSTHINKCB | |
Airzone ZBS Wireless Lite Controller White | □ AZZBSLITERB | |
Airzone ZBS Wireless Think Controller White | □ AZZBSTHINKRB | |
Deluxe Wired MA Remote Controller† | □ PAR-40MAAU | |
Simple MA Remote Controller† | □ PAC-YT53CRAU-J | |
Touch MA Controller† | □ PAR-CT01MAU-SB | |
Wireless Remote Controller | kumo touch™ RedLINK™ Wireless Controller | □ MHK2 |
Wireless MA Receiver | □ PAR-FA32MA-W | |
Wireless MA Remote Controller | □ PAR-FL32MA-E | |
Wireless Remote Contoller | □ PAR-SL101A-E | |
Wireless Signal Receiver | □ PAR-SA9FA-E | |
Wireless Signal Receiver Panel | □ PAR-SR4LU-E | |
Casement | Multi-function Casement | □ PAC-SJ41TM-E |
Condensate | Blue Diamond (Advanced) Mini Condensate Pump w/ Reservoir & Sensor | |
(208/230V) [recommended] | □ X87-721 |
Blue Diamond (MicroBlue) Mini Condensate Pump (110/208/230V) up to 18,000
BTU/H| □ X86-003
Blue Diamond Sensor Extension Cable — 15 Ft.| □ C13-103
Refco Condensate Pump (100-240 VAC) up to 120,000 BTU/H| □ COMBI
Disconnect Switch| (30A/600V/UL) [fits 2” X 4” utility box] – Black| □ TAZ-
MS303
(30A/600V/UL) [fits 2” X 4” utility box] – White| □ TAZ-MS303W
Filter| High Efficiency Filter Element| □ PAC-SH59KF-E
i-see Sensor® Panel| Grille with 3D i-see Sensor® (required)| □ PLP-41EAEU
Lineset| 100’ x 1/4” x 100’ / 1/2” Lineset (Twin-Tube Insulation)| □
MLS141212T-100
15’ x 1/4” x 15’ / 1/2” Lineset (Twin-Tube Insulation)| □ MLS141212T-15
30’ x 1/4” x 30’ / 1/2” Lineset (Twin-Tube Insulation)| □ MLS141212T-30
50’ x 1/4” x 50’ / 1/2” Lineset (Twin-Tube Insulation)| □ MLS141212T-50
65’ x 1/4” x 65’ / 1/2” Lineset (Twin-Tube Insulation)| □ MLS141212T-65
Shutter Plate| Shutter Plate| □ PAC-SJ37SP-E
Space Panel| Space Panel| □ PAC-SJ38AS-E
NOTES:
‡PAC-SF40RM-E (Unable to use with wireless remote controller)
NOTE
- CHOOSE THE GRILLE AMONG THE DEDICATED GRILLES
- REINFORCE THE SUSPENSION BOLT FOR EARTHQUAKE-RESISTANCE AS NEEDED.
- FOR THE SUSPENSION BOLT, USE M10 OR W3/8. (PROCURED AT THE LOCAL SITE.)
- FOR DRAIN PIPE, USE VP-25(0.D. n1-1/4″( 32) PVC TUBE). DRAIN PUMP INCLUSION. RAISE IS MAX 33-7/16″(850mm) FROM THE CEILING.
- ELECTRICAL BOX MAY BE REMOVED FOR THE SERVICE PURPOSE. MAKE SURE TO SLACK THE ELECTRICAL WIRE LITTLE BIT FOR CONTROL/POWER WIRES CONNECTION.
- THE HEIGHT OF THE INDOOR UNIT IS ABLE TO BE ADJUSTED WITH THE GRILLE ATTACHED.
- REQUIRES “E” OR MORE SPACE BETWEEN TRANSOM AND CEILING FOR THE INSTALLATION.
- WHEN INSTALLING THE BRANCH DUCTS, BE SURE TO INSULATE ADEQUATELY. OTHERWISE CONDENSATION AND DRIPPING MAY OCCUR. (IT BECOMES THE CAUSE OF DROPLET OR DROPLET DRIPPING.)
- AS FOR NECESSARY INSTALLATION/SERVICE SPACE, PLEASE REFER TO THE RIGHT AT FIGURE
- FOR THE INSTALLATION OF THE OPTIONAL HIGH EFFICIENCY FILTER OR MULTIFUNCTIONAL CASEMENT, REFER TO SPECIAL DRAWING.
12/18/24/30/36/42
MODELS | A | B | C | D | E | F | ||
---|---|---|---|---|---|---|---|---|
12/18 | FLARED CONNECTION 1/4F | REFRIGERANT PIPE{ FLARED CONNECTION 1/2F |
(241)
| 10-3/16 (258)| 3(76)| | 10-7/16(265) OR MORE| 137-13/16(3500) OR LESS
24/30/36/42| FLARED CONNECTION 3/8F| REFRIGERANT PIPE{ FLARED CONNECTION 5/8F|
11-1/16 (281)| 11-3/4| 3-1/8| 12(305) OR MORE| 177-3/16(4500) OR LESS
Job Name:___
System Reference:__
Date:___
1340 Satellite Boulevard Suwanee, GA 30024 Toll Free: 800-433-4822 www.mehvac.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>