MITSUBISHI ELECTRIC PLA-A12EA7 12,000 BTU/H 3 X 3 Ceiling Cassette Owner’s Manual

June 13, 2024
Mitsubishi Electric

MITSUBISHI ELECTRIC PLA-A12EA7 12,000 BTU/H 3 X 3 Ceiling Cassette

Product Information

  • Model: PLA-A12EA7
  • Cooling Capacity: 12,000 BTU/H
  • Heating Capacity: 14,000 BTU/H
  • Unit Type: Ceiling Cassette
  • Voltage, Phase, Frequency: 208/230V AC, 1 phase, 60Hz
  • Guaranteed Voltage Range: 198-253V AC
  • Short-circuit Current Rating [SCCR]: MCA
  • Fan Motor Full Load Amperage: A
  • Airflow Rate at Cooling, Dry: CFM
  • Airflow Rate at Cooling, Wet: CFM
  • Airflow Rate at Heating, Dry: CFM
  • Sound Pressure Level [Cooling]: dB[A]
  • Sound Pressure Level [Heating]: dB[A]
  • Drain Pipe Size: In. [mm]
  • Condensate Lift Mechanism, Maximum Distance: In. [mm]
  • Coating on Heat Exchanger: White Munsell 6.4Y 8.9/0.4
  • External Finish Color: White
  • Unit Dimensions (W x D x H): 33-1/16 // 37-13/32 x 33-1/16 // 37-13/32 x 10-5/32 // 1-9/16 [840 // 950 x 840 // 950 x 258 // 40] (inches // mm)
  • Unit Weight: Lbs. [kg]
  • Package Dimensions (W x D x H): 35-9/16 // 39-6/16 x 34-5/16 // 38-3/16 x 15 // 4-12/16 [903 // 1,000 x 871 // 970 x 381 // 121] (inches // mm)
  • Package Weight: Lbs. [kg]
  • Gas Pipe Size O.D. [Flared]: 1/2 [12.7] inches [mm]
  • Liquid Pipe Size O.D. [Flared]: 1/4 [6.35] inches [mm] –
  • Refrigerant: R410A

Product Usage Instructions

  1. Before installation, ensure that the electrical wire is slacked a little bit.
  2. Install the indoor unit in the ceiling at a height of 118-1/8 inches (3000mm) or more, with a clearance of 70-7/8 inches (1800mm) or more from the floor.
  3. Connect the indoor unit to the outdoor unit using the provided connecting terminal block.
  4. Make sure to use self-tap screws in four places to connect the indoor unit to the branch duct.
  5. Install the optional accessories like control interface, remote sensor, and wired remote controller (PAC-SF40RM-E).
  6. Ensure proper ventilation by providing fresh air intake holes and air outlet holes in the ceiling.
  7. Follow the specified ceiling grille dimensions for proper installation.
  8. Connect the remote controller wire to the designated entry points.
  9. For detailed installation instructions, refer to the user manual.

Note: The product specifications are subject to change without notice.

GENERAL FEATURES

  • Space-efficient ductless installation
  • Equipped with 3D i-see Sensor® for enhanced comfort and energy efficiency
  • Airflow settings for high and low ceiling applications
  • Individual vane settings for direct/indirect airflow control or variable airflow patterns
  • Knockouts for outside-air intake and branch-duct run
  • Filter indicator signal
  • Easy-to-clean, washable filter (optional high-efficiency filter available -requires multi-function casement)
  • Built-in condensate lift mechanism
  • Ideal for retail shops, classrooms, office spaces, conference centers, building lobbies, and more
  • Multiple control options available:
    • kumo cloud® smart device app for remote access
    • Third-party interface options
    • Wired or wireless controllers
Specifications System
Unit Type PLA-A12EA7
Cooling Capacity1, 3 BTU/H
Heating Capacity2, 3 BTU/H

Electrical

| Voltage, Phase, Frequency| 208/230, 1, 60
Guaranteed Voltage Range| V AC| 198- 253V
Voltage: Indoor – Outdoor, S1-S2| V AC| 208/230
Voltage: Indoor – Outdoor, S2-S3| V DC| 24
Short-circuit Current Rating [SCCR]| kA| 5
Indoor Unit| MCA| A| 1.0
Fan Motor Full Load Amperage| A| 0.26
Airflow Rate at Cooling, Dry| CFM| 420–460–490–530
Airflow Rate at Cooling, Wet| CFM| 380–420–450–490
Airflow Rate at Heating, Dry| CFM| 420–460–490–530
Sound Pressure Level [Cooling]| dB[A]| 27–28–29–30
Sound Pressure Level [Heating]| dB[A]| 27–28–29–30
Drain Pipe Size| In. [mm]| 1-1/4 [32]
Condensate Lift Mechanism, Maximum Distance| In. [mm]| 33-7/16 [849]
Coating on Heat Exchanger| —
External Finish Color| White Munsell 6.4Y 8.9/0.4
Unit Dimensions| W x D x H: In. [mm]| 33-1/16 // 37-13/32 x 33-1/16 // 37-13/32 x 10-5/32 // 1-9/16 [840 // 950 x 840 // 950 x 258 // 40]
Package Dimensions| W x D x H: In. [mm]| 35-9/16 // 39-6/16 x 34-5/16 // 38-3/16 x 15 // 4-12/16 [903 // 1,000 x 871 // 970 x 381 // 121]
Unit Weight| Lbs. [kg]| 46 // 11 [21 // 5]
Package Weight| Lbs. [kg]| 68 [31]
Refrigerant| Type| R410A

Piping

| Gas Pipe Size O.D. [Flared]| In.[mm]| 1/2 [12.7]
Liquid Pipe Size O.D. [Flared]| In.[mm]| 1/4 [6.35]

NOTES: 1 Cooling (Indoor // Outdoor) °F 80 DB, 67 WB // 95 DB, 75 WB
Conditions: 2 Heating at 47°F (Indoor // Outdoor) °F 70 DB, 60 WB // 47 DB, 43 WB

3Capacity varies based on the number of indoor units operating and the model of the Multi-zone Outdoor Unit. For reference to connected capacity charts, please refer Multi-zone Outdoor Unit Operational Performance.:

INDOOR UNIT ACCESSORIES: PLA-A12EA7

Control Interface 3-Pin Connector □ PAC-715AD
BACnet® and Modbus® Interface □ PAC-UKPRC001-CN-1
CN24 Relay Kit □ CN24RELAY-KIT-CM3
IT Extender □ PAC-WHS01IE-E
kumo station® for kumo cloud® □ PAC-WHS01HC-E
Lockdown bracket for remote controller □ RCMKP1CB
Remote Operation Adapter‡ □ PAC-SF40RM-E
Thermostat Interface □ PAC-US444CN-1
Thermostat Interface □ PAC-US445CN-1
USNAP Adapter □ PAC-WHS01UP-E
Wireless Interface for kumo cloud® □ PAC-USWHS002-WF-2
Remote Sensor Flush Mount Remote Temperature Sensor □ PAC-USSEN002-FM-1
Flush Mount Temperature Sensor □ PAC-USSEN001-FM-1
Remote Temperature Sensor □ PAC-SE41TS-E
Wireless temperature and humitity sensor for kumo cloud® □ PAC-USWHS003-TH-1
Wired Remote Controller Airzone ZBS Wired Blueface Principal Controller
White □ AZZBSBLUEFACECB
Airzone ZBS Wired Lite Controller White □ AZZBSLITECB
Airzone ZBS Wired Think Controller White □ AZZBSTHINKCB
Airzone ZBS Wireless Lite Controller White □ AZZBSLITERB
Airzone ZBS Wireless Think Controller White □ AZZBSTHINKRB
Deluxe Wired MA Remote Controller† □ PAR-40MAAU
Simple MA Remote Controller† □ PAC-YT53CRAU-J
Touch MA Controller† □ PAR-CT01MAU-SB
Wireless Remote Controller kumo touch™ RedLINK™ Wireless Controller □ MHK2
Wireless MA Receiver □ PAR-FA32MA-W
Wireless MA Remote Controller □ PAR-FL32MA-E
Wireless Remote Contoller □ PAR-SL101A-E
Wireless Signal Receiver □ PAR-SA9FA-E
Wireless Signal Receiver Panel □ PAR-SR4LU-E
Casement Multi-function Casement □ PAC-SJ41TM-E
Condensate Blue Diamond (Advanced) Mini Condensate Pump w/ Reservoir & Sensor
(208/230V) [recommended] □ X87-721

Blue Diamond (MicroBlue) Mini Condensate Pump (110/208/230V) up to 18,000 BTU/H| □ X86-003
Blue Diamond Sensor Extension Cable — 15 Ft.| □ C13-103
Refco Condensate Pump (100-240 VAC) up to 120,000 BTU/H| □ COMBI
Disconnect Switch| (30A/600V/UL) [fits 2” X 4” utility box] – Black| □ TAZ- MS303
(30A/600V/UL) [fits 2” X 4” utility box] – White| □ TAZ-MS303W
Filter| High Efficiency Filter Element| □ PAC-SH59KF-E
i-see Sensor® Panel| Grille with 3D i-see Sensor® (required)| □ PLP-41EAEU
Lineset| 100’ x 1/4” x 100’ / 1/2” Lineset (Twin-Tube Insulation)| □ MLS141212T-100
15’ x 1/4” x 15’ / 1/2” Lineset (Twin-Tube Insulation)| □ MLS141212T-15
30’ x 1/4” x 30’ / 1/2” Lineset (Twin-Tube Insulation)| □ MLS141212T-30
50’ x 1/4” x 50’ / 1/2” Lineset (Twin-Tube Insulation)| □ MLS141212T-50
65’ x 1/4” x 65’ / 1/2” Lineset (Twin-Tube Insulation)| □ MLS141212T-65
Shutter Plate| Shutter Plate| □ PAC-SJ37SP-E
Space Panel| Space Panel| □ PAC-SJ38AS-E

NOTES:
‡PAC-SF40RM-E (Unable to use with wireless remote controller)

NOTE

  1. CHOOSE THE GRILLE AMONG THE DEDICATED GRILLES
  2. REINFORCE THE SUSPENSION BOLT FOR EARTHQUAKE-RESISTANCE AS NEEDED.
  3. FOR THE SUSPENSION BOLT, USE M10 OR W3/8. (PROCURED AT THE LOCAL SITE.)
  4. FOR DRAIN PIPE, USE VP-25(0.D. n1-1/4″( 32) PVC TUBE). DRAIN PUMP INCLUSION. RAISE IS MAX 33-7/16″(850mm) FROM THE CEILING.
  5. ELECTRICAL BOX MAY BE REMOVED FOR THE SERVICE PURPOSE. MAKE SURE TO SLACK THE ELECTRICAL WIRE LITTLE BIT FOR CONTROL/POWER WIRES CONNECTION.
  6. THE HEIGHT OF THE INDOOR UNIT IS ABLE TO BE ADJUSTED WITH THE GRILLE ATTACHED.
  7. REQUIRES “E” OR MORE SPACE BETWEEN TRANSOM AND CEILING FOR THE INSTALLATION.
  8. WHEN INSTALLING THE BRANCH DUCTS, BE SURE TO INSULATE ADEQUATELY. OTHERWISE CONDENSATION AND DRIPPING MAY OCCUR. (IT BECOMES THE CAUSE OF DROPLET OR DROPLET DRIPPING.)
  9. AS FOR NECESSARY INSTALLATION/SERVICE SPACE, PLEASE REFER TO THE RIGHT AT FIGURE
  10. FOR THE INSTALLATION OF THE OPTIONAL HIGH EFFICIENCY FILTER OR MULTIFUNCTIONAL CASEMENT, REFER TO SPECIAL DRAWING.

12/18/24/30/36/42

MODELS A B C D E F
12/18 FLARED CONNECTION 1/4F REFRIGERANT PIPE{ FLARED CONNECTION 1/2F

(241)

| 10-3/16 (258)| 3(76)| | 10-7/16(265) OR MORE| 137-13/16(3500) OR LESS
24/30/36/42| FLARED CONNECTION 3/8F| REFRIGERANT PIPE{ FLARED CONNECTION 5/8F| 11-1/16 (281)| 11-3/4| 3-1/8| 12(305) OR MORE| 177-3/16(4500) OR LESS

Job Name:___
System Reference:__
Date:___

1340 Satellite Boulevard Suwanee, GA 30024 Toll Free: 800-433-4822 www.mehvac.com