CyberPower MP1096SSW Surge Multi Pack User Manual

June 13, 2024
CyberPower

CyberPower-LOGO

CyberPower MP1096SSW Surge Multi Pack

CyberPower-MP1096SSW-Surge-Multi-Pack-PRODUCT-IMG

10-OUTLET SURGE PROTECTOR (10 AC & 2 USB PORTS)

CyberPower-MP1096SSW-Surge-Multi-Pack-FIG-1

FEATURES

  1. ON/OFF Reset Control Switch and Circuit Breaker Controls power to all outlets. The switch is also a 15 A breaker. When an overload occurs, it will automatically switch off. To resume operation, ensure the overload condition is removed and reset the surge protector by switching the unit ON.
  2. USB-A Charging Port (1)
  3. USB-C Charging Port (1)
  4. Standard Grounded Outlets (5)

SPECIFICATIONS

  • Model Number: P504UC
  • Outlets: Standard Grounded Outlets (5), USB Charging Ports (2)
  • Surge Protection: 500 Joules
  • USB-A Charging Output: 5 V/2.4 A
  • USB-C Charging Output: 15 W
  • USB Output Total: 15 W
  • Electrical Rating: 125 V/15 A/1875 W
  • UL Clamping Voltage: UL 1449 4th/800 V (L-N)
  • Maximum Peak Current: 15,000 A
  • 1 AC Line Protected: L-N: 15,000 A
  • Response Time: Less than 1 nanosecond
  • Plug Type: Flat
  • Cord Length: 4 ft

WARNING: This product can expose you to chemicals including bisphenol A (BPA) and styrene, which is known to the State of California to cause reproductive harm and cancer. For more information, go to www.P65Warnings.ca.gov.

CAUTION

  • TO REDUCE THE RISK OF ELECTRIC SHOCK:
  • Use only in dry locations and only indoors.
  • DO NOT plug into another relocatable power tap.
  • DO NOT “daisy chain” surge protectors.
  • DO NOT use with any aquarium equipment.
  • DO NOT use if properly grounded outlets are not available.
  • DO NOT install this device if there is less than 10 meters (30 feet) of wire between the electrical outlet and electrical service panel.
  • DO NOT use for medical or life support equipment. This device features an internal protection that will disconnect the surge protective component at the end of its useful life, but it will maintain unprotected power to the load.

TROUBLESHOOTING

  • If the ON/OFF is switched OFF, the 15 Amp circuit breaker may have tripped.
  • Examine your connected equipment and remove the device that is overloading the circuit. Then, turn the ON/OFF switch back to RESET.
  • If the grounded indicator does not light when you plug in the surge protector, move the surge protector to a different grounded three-prong AC outlet. If it still does not light, return the product to the retailer for assistance. If the surge protector appears to be working properly, your outlets may not be properly grounded and need to be repaired by a professional electrician.
  • If the protected indicator does not light, the surge protector’s AC lines are no longer protected from surge. The surge protector may have received a power surge or spike beyond its specified limits that overloaded the protection circuitry and rendered it inactive. The surge protector has protected your connected equipment as designed, but it will not protect against future surges and spikes. It should be replaced.

FOR MORE INFORMATION

  • Visit CyberPowerSystems.com for more information regarding:
  • Product information and certifications
  • Product warranty
  • Connected equipment guarantee

TECHNICAL SUPPORT

  • Visit: CyberPowerSystems.com/support
  • Toll-Free: 1-877-297-6937
  • Hours of Operation: Monday – Friday: 7:00am – 6:00pm CST
  • © 2023 Cyber Power Systems (USA), Inc. All rights reserved.
  • All other trademarks are the property of their respective owners.

5-OUTLET SURGE PROTECTOR (5 AC OUTLETS & 2 USB PORTS)

CyberPower-MP1096SSW-Surge-Multi-Pack-FIG-2

FEATURES

  1. ON/OFF Reset Control Switch and Circuit Breaker Controls power to all outlets. The switch is also a 15 A breaker. When an overload occurs, it will automatically switch off. To resume operation, ensure the overload condition is removed and reset the surge protector by switching the unit ON.
  2. USB-A Charging Port (1)
  3. USB-C Charging Port (1)
  4. Standard Grounded Outlets (5)

SPECIFICATIONS

  • Model Number: P504UC
  • Outlets: Standard Grounded Outlets (5), USB Charging Ports (2)
  • Surge Protection: 500 Joules
  • USB-A Charging Output : 5 V/2.4 A
  • USB-C Charging Output: 15 W
  • USB Output Total: 15 W
  • Electrical Rating: 125 V/15 A/1875 W
  • UL Clamping Voltage: UL 1449 4th/800 V (L-N)
  • Maximum Peak Current: 15,000 A
  • 1 AC Line Protected: L-N: 15,000 A
  • Response Time: Less than 1 nanosecond
  • Plug Type: Flat
  • Cord Length: 4 ft

WARNING: This product can expose you to chemicals including bisphenol A (BPA) and styrene, which is known to the State of California to cause reproductive harm and cancer. For more information, go to www.P65Warnings.ca.gov.

CAUTION

  • TO REDUCE THE RISK OF ELECTRIC SHOCK:
  • Use only in dry locations and only indoors.
  • DO NOT plug into another relocatable power tap.
  • DO NOT “daisy chain” surge protectors.
  • DO NOT use with any aquarium equipment.
  • DO NOT use if properly grounded outlets are not available.
  • DO NOT install this device if there is less than 10 meters (30 feet) of wire between the electrical outlet and electrical service panel.
  • DO NOT use for medical or life support equipment. This device features an internal protection that will disconnect the surge protective component at the end of its useful life, but it will maintain unprotected power to the load.

TROUBLESHOOTING
If the ON/OFF is switched OFF, the 15 Amp circuit breaker may have tripped.
Examine your connected equipment and remove the device that is overloading the circuit. Then, turn the ON/OFF switch back to RESET.

FOR MORE INFORMATION

  • Visit CyberPowerSystems.com for more information regarding:
  • Product information and certifications
  • Product warranty
  • Connected equipment guarantee

3 OUTLET SURGE PROTECTOR (3 AC OUTLETS & 4 USB PORTS)

CyberPower-MP1096SSW-Surge-Multi-Pack-FIG-3

FEATURES

  1. Standard Grounded Outlets (3)
  2. USB-A Charging Ports (4)
  3. Turn On/Off LED for USB Ports

SPECIFICATIONS

  • Model Number: P3WU
  • Outlets: Standard Grounded Outlets (3), USB Charging Ports (4)
  • USB-A Charging Output: 5 V/4.2 A (shared)
  • Electrical Rating: 125 V/15 A/1875 W

CAUTION

  • TO REDUCE THE RISK OF ELECTRIC SHOCK:
  • Use only in dry locations and only indoors.
  • DO NOT plug into another relocatable power tap.
  • DO NOT “daisy chain” surge protectors.
  • DO NOT use with any aquarium equipment.
  • DO NOT use if properly grounded outlets are not available.
  • DO NOT install this device if there is less than 10 meters (30 feet) of wire between the electrical outlet and electrical service panel.
  • DO NOT use for medical or life support equipment. This device features an internal protection that will disconnect the surge protective component at the end of its useful life, but it will maintain unprotected power to the load.

TROUBLESHOOTING

  • If the ON/OFF is switched OFF, the 15 Amp circuit breaker may have tripped.
  • Examine your connected equipment and remove the device that is overloading the circuit. Then, turn the ON/OFF switch back to RESET.

FOR MORE INFORMATION

  • Visit CyberPowerSystems.com for more information regarding:
  • Product information and certifications
  • Product warranty
  • Connected equipment guarantee

FCC STATEMENT

This device complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions:

  1. this device may not cause harmful interference, and
  2. this device must accept any interference received, including interference that may cause undesired operation.

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment on and off, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.