1 DESCRIPTION
The E-Z Flush™ sends out a continuous infrared beam that is reflected back by the presence of a person in front of the urinal or toilet. The technology differentiates between someone walking past the unit or actually using the fixture. E-Z Flush models ZERK-CP and ZERK-CPM retrofit Zurn and Sloan valves. For Delaney valves, order model ZERK-GP-LY or ZERK-CPM-LY.
2 E-Z FLUSH COMPONENTS
3 INSTALLATION
Shut off water supply at stop.
A – Using the supplied wrench, loosen handle nut.
B – Remove handle from flush valve.
Note: A small amount of water may drip from the port
C – Place gasket into nut and attach the E-Z Flush unit where the handle was
removed.
D – Tighten nut with supplied wrench.
Note: Save handle in the event you wish to reuse for service of E-Z Flush.
4 ACTIVATION
Using supplied battery compartment wrench, remove battery compartment from the E-Z FlushrM unit.
Load batteries into compartment tray (note position of batteries in tray), and reinstall battery tray into the E-Z Flush unit.
Secure tray with battery compartment wrench. The last three turns of the wrench will activate the E-Z Flush unit. The E-Z Flush System is now operational.
Your E-Z Flush unit comes preset from the factory. If special circumstances require adjustment of the activation distance, see Step 7 – “To Change Sensor Activation Distance.”
The E-Z Flush unit has a 10-minute start-up sequence in which the sensor will flash the User-In-View yellow L.E.D. continuously as long as a user is in view. After the start-up sequence is completed and when the sensor has a user in view, the User-In-View yellow L.E.D. will flash only 3 times after a 5-second delay. This delay prevents needless flushes when someone walks by.
5 VISUAL INDICATOR GUIDE
6 ADJUSTING YOUR E-Z FLUSH
7 TO CHANGE SENSOR ACTIVATION DISTANCE
- Remove battery compartment tray as shown in Step 6.
- Remove cover and sensor adjustor tool as shown in Step 6.
- Replace battery compartment in E-Z Flush to activate unit (the yellow L.E.D. will flash continuously when it has an object in view for the 10-minute reset period). See Step 4 – “Activation.”
- Have an individual stand at desired activation distance.
- Use sensor adjustor tool and turn the Sensor Range Adjustment Screw all the way down and then turn slowly up until yellow L.E.D. begins to flash.
- Ensure sensor is not detecting stall door or wall by closing door, stepping out of sensor path and making sure yellow L.E.D. is not flashing. If sensor locks onto door or wall, unit will not flush properly. Shorten activation distance.
- Remove battery compartment, replace sensor adjustor tool and cover. Replace battery compartment tray to reactivate E-Z Flush unit.
- After 10-minute start-up sequence, the yellow L.E.D. will flash only 3 times when a user is in view (after a 5-second delay).
8 WIRING DIAGRAM
9 TROUBLESHOOTING GUIDE
ZURN INDUSTRIES, LLC. COMMERCIAL BRASS OPERATION
5900 ELWIN BUCHANAN DRIVE, SANFORD,NC, U.S.A.27330 PHONE:
1-800-997-3876 FAX: 919/775-3541
WEBSITE: www.zurn.com
ZURN INDUSTRIES LIMITED 3544 NASHUA DRIVE, MISSISSAUGA, ONTARIO L4V 1L2 PHONE:
905/405-8272 FAX: 905/405-1292
References
- P65Warnings.ca.gov
- Engineered Water Solutions | Zurn
- Engineered Water Solutions | Zurn
- Patents | Zurn Industries LLC's products