Autonics FM6M-1P4 (01) Measure Counter User Manual

June 13, 2024
Autonics

MEASURE COUNTER
FM SERIES
INSTRUCTION MANUALAutonics FM6M-1P4 \(01\) Measure
Counter

Thank you for choosing our Autonics product.
Please read the following safety considerations before use.

Safety Considerations

  • Please observe all safety considerations for safe and proper product operation to avoid hazards.

  • Safety considerations are categorized as follows.
    Warning Failure to follow these instructions may result in serious injury or death.
    Caution Failure to follow these instructions may result in personal injury or product damage.

  • The symbols used on the product and instruction manual represent the following symbol represents caution due to special circumstances in which hazards may occur.

Warning

  1. Fail-safe device must be installed when using the unit with machinery that may cause serious injury or substantial economic loss. (e.g. nuclear power control, medical equipment, ships, vehicles, railways, aircraft, combustion  apparatus, safety equipment, crime/disaster prevention devices, etc.)
    Failure to follow this instruction may result in fire, personal injury, or economic loss.

  2. Install on a device panel to use.
    Failure to follow this instruction may result in electric shock or fire.

  3. Do not connect, repair, or inspect the unit while connected to a power source.
    Failure to follow this instruction may result in electric shock or fire.

  4. Check ‘Connections’ before wiring.
    Failure to follow this instruction may result in fire.

  5. Do not disassemble or modify the unit.
    Failure to follow this instruction may result in electric shock or fire.

Caution

  1. When connecting the power/sensor input and relay output, use AWG 20(0.50mm2) cable or over, and tighten the terminal screw with a tightening torque of 0.74 to 0.90N.m.
    Failure to follow this instruction may result in fire or malfunction due to contact failure.

  2. Use the unit within the rated specifications.
    Failure to follow this instruction may result in fire or product damage.

  3. Use dry cloth to clean the unit, and do not use water or organic solvent.
    Failure to follow this instruction may result in electric shock or fire.

  4. Do not use the unit in the place where flammable/explosive/corrosive gas, humidity, direct sunlight, radiant heat, vibration, impact, or salinity may be present.
    Failure to follow this instruction may result in fire or explosion.

  5. Keep metal chip, dust, and wire residue from flowing into the unit.
    Failure to follow this instruction may result in fire or product damage.

Dimensions

Autonics FM6M-1P4 \(01\) Measure Counter - Figure 1

Counting Operation for Indicator (FM M-I4)

Autonics FM6M-1P4 \(01\) Measure Counter - Figure 2

※- display is only for F, K, Q, S output operation mode and it cannot be set.

Input Operation Mode

Autonics FM6M-1P4 \(01\) Measure Counter - Figure 3

  • A: over min. signal width, B: over than 1/2 of min. signal width.
    If the signal is smaller than these width, it may cause counting error (±1).

  • The above specifications are subject to change and some models may be discontinued without notice.

  • Be sure to follow cautions written in the instruction manual and the technical descriptions (catalog, homepage).

Specifications

Model 1-stage setting FM4M-1P4 FM6M-1P4
2-stage setting FM4M-2P4 FM6M-2P4
Indicator FM4M-I4 FM6M-I4
Display digit 4-digit 6-digit
Character size (WxH) 6x1Omm 4x8mm
Power supply 100-240VAC– 50/60Hz
Permissible voltage range 90 to 110% of rated voltage
Power consumption • 1-stage: max. 4.6VA

• 2-stage: max. 5.8VA
• Indicator: max. 3.8VA
Max. counting speed of CP1/CP2| Selectable lcps/30cps/300cps/2kcps/5kcps
Return time| Max. 500ms
Min. signal width| RESET: approx. 20ms
Input method| Selectable voltage input (PNP) method or no-voltage input (NPN) method [Voltage input (PNP) method]-input impedance: max. 10.8k0,

[No-voltage input (NPN) method]-short-circuit impedance: max. 4700,
short-circuit residual voltage: max. 1VDC, open-circuit impedance: min. 100k0
One-shot output time| 0.01 to 99.99 sec
Control output| Contact| Type| • 1-stage: Instantaneous SPDT (1c)
• 2-stage: OUT1-Instantaneous SPST (la), OUT2-Instantaneous SPST (la)
Capacity| 250VAC— 3A resistive load
Solid
state| Type| • 1-stage: 1 NPN open collector
• 2-stage: OUT1-1 NPN open collector, OUT2-1 NPN open collector
Capacity| NPN open collector output
• Load voltage: max. 30VDC
• Load current: max. 100mA
• Residual voltage: max. 1VDC
Relay
life cycle| Mechanical| Min. 5,000,000 operations
Electrical| Min. 100,000 operations (250VAC 3A resistive load)
Insulation resistance| Over 100M0 (at 500VDC megger)
External power supply| Max. 12VDC ±10% 50mA
Memory retention| Approx. 10 years (non-volatile memory)
Dielectric strength| 2,000VAC 50/60Hz for 1 min (between all terminals and case)
Noise immunity| ±2kV the square wave noise (pulse width 1ps) by noise simulator
Vibration| Mechanical| 0.75mm amplitude at frequency 10 to 55Hz (for 1 min) in each X, Y, Z direction for 1 hour
Malfunction| 0.5mm amplitude at frequency 10 to 55Hz (for 1 min) in each X, Y, Z direction for 10 minutes
Shock| Mechanical| 300m/s2 (approx. 30G) in each X, Y, Z direction for 3 times
Malfunction| 100m/s2 (approx. 10G) in each X, Y, Z direction for 3 times
Environ- ment| Ambient temp.| -10 to 55°C, storage: -25 to 65°C
Ambient humi.| 35 to 85%RH, storage: 35 to 85%RH
Protection structure| IP20 (front part, IEC standard)
Approval|
Weightx’| 1-stage setting| Approx. 245g (approx. 180g)
2-stage setting| Approx. 265g (approx. 200g)
Indicator| Approx. 225g (approx. 160g)

Connections

Autonics FM6M-1P4 \(01\) Measure Counter - Figure 4

Example of Input/ Output Connection

  • When operating load by sensor power

The sum of operating current capacity of load 1 and sensor should not be over external power capacity (50mA).

When operating load by external power

  •  The capacity of load 1 should not be over transistor switching capacity (max. 30VDC 100mA).
  • Do not supply the reverse polarity power.
    ※ When using inductive load (relay, etc.), connect surge absorbers at both ends of load 1.

Output Operation Mode

Autonics FM6M-1P4 \(01\) Measure Counter - Figure 7

Parameter Setting

  • Hold the MODEkey for 3 sec to save the setting value and return to RUN mode after changing the setting value.

  • If there is no key input for 60 sec while setting the parameters, the new settings are ignored, and the unit returns to RUN mode with previous settings.

  • Press the , keys to select or set the desired value. Press the key once after changing the setting value, to save the setting value and move to the next parameter.

  • The dotted line parameters may not appear depending on output specifications or other parameter settings.

  • 1: Each parameter and corresponding setting value will flash alternately every 0.5 sec.
    Autonics FM6M-1P4 \(01\) Measure Counter - Figure 8

  • 2: Multiply mode [MULT]: Displayed by multiplying input signal and setting value.
    Input signal×Setting value=Display value (input signal: 1, setting value: 4, it displays 4 (1×4)

  • 3: Divide mode [D IV]: Displays 1 when input signals are input as the setting value.
    Input signal/Setting value=Display value (input signal: 4, setting value: 4, it displays 1 (4/4)

Autonics FM6M-1P4 \(01\) Measure Counter - Figure 9

Input Connection

Voltage input (PNP)

  • Solid state input (standard sensor: PNP output type sensor)
  • Contact input
    Autonics FM6M-1P4 \(01\) Measure Counter - Figure 10

No-voltage input (NPN)

  • Solid state input (standard sensor: NPN output type sensor)
  • Contact input
    Autonics FM6M-1P4 \(01\) Measure Counter - Figure 11

Factory Default

Autonics FM6M-1P4 \(01\) Measure Counter - Figure 12

Error Display and Output Operation

Error Display Error description Troubleshooting
ERR0 Setting value is 0. Change the setting value anything but 0.
  • When error occurs, the output turns OFF.

  • When 1st setting value is set as 0 (zero), OUT1 maintains OFF.
    When 2nd setting value is smaller than 1st setting value, 1st setting value is ignored and only OUT2 output operates.

  • Indicator model does not have error display function.

Cautions during Use

  1. Follow instructions in ‘Cautions during Use’. Otherwise, It may cause unexpected accidents.

  2. Use the product, 0.1 sec after supplying power.

  3. When supplying or turning off the power, use a switch or etc. to avoid chattering.

  4. Install a power switch or circuit breaker in the easily accessible place for supplying or disconnecting the power.

  5. In case of contact input, set count speed to low speed mode (1cps or 30 cps) to operate.
    If set to high speed mode (300cps, 2kcps, 5kcps), counting error occurs due to chattering.

  6. Keep away from high voltage lines or power lines to prevent inductive noise.
    In case installing power line and input signal line closely, use line filter or varistor at power line and shielded wire at input signal line.
    Do not use near the equipment which generates strong magnetic force or high frequency noise.

  7. This product may be used in the following environments.
    ①Indoors (in the environment condition rated in ‘Specifications’)
    ②Altitude max. 2,000m
    ③Pollution degree 2
    ④Installation category II

Major Products

  • Photoelectric Sensors Fiber Optic Sensors
  • Door Sensors
  • Door Side Sensors
  • Area Sensors
  • Proximity Sensors
  • Pressure Sensors
  • Rotary Encoders
  • Connector/Sockets
  • Switching Mode Power Supplies
  • Control Switches/Lamps/Buzzers
  • I/O Terminal Blocks & Cables
  • Stepper Motors/Drivers/Motion Controllers
  • Graphic/Logic Panels
  • Field Network Devices
  • Laser Marking System (Fiber, Co₂, Nd: YAG)
  • Laser Welding/Cutting System
  • Temperature Controllers
  • Temperature/Humidity Transducers
  • SSR/Power Controllers
  • Counters
  • Timers
  • Panel Meters
  • Tachometer/Pulse (Rate) Meters
  • Display Units
  • Sensor Controllers

http://www.autonics.com
HEAD QUARTERS:
18, Bansong-ro 513 beon-gil, Haeundae-gu, Busan, South
Korea, 48002
TEL: 82-51-519-3232
E-mail: sales@autonics.com

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Autonics User Manuals

Related Manuals