MEASURE COUNTER
FM SERIES
INSTRUCTION MANUAL
Thank you for choosing our Autonics product.
Please read the following safety considerations before use.
Safety Considerations
-
Please observe all safety considerations for safe and proper product operation to avoid hazards.
-
Safety considerations are categorized as follows.
Warning Failure to follow these instructions may result in serious injury or death.
Caution Failure to follow these instructions may result in personal injury or product damage. -
The symbols used on the product and instruction manual represent the following symbol represents caution due to special circumstances in which hazards may occur.
Warning
-
Fail-safe device must be installed when using the unit with machinery that may cause serious injury or substantial economic loss. (e.g. nuclear power control, medical equipment, ships, vehicles, railways, aircraft, combustion apparatus, safety equipment, crime/disaster prevention devices, etc.)
Failure to follow this instruction may result in fire, personal injury, or economic loss. -
Install on a device panel to use.
Failure to follow this instruction may result in electric shock or fire. -
Do not connect, repair, or inspect the unit while connected to a power source.
Failure to follow this instruction may result in electric shock or fire. -
Check ‘Connections’ before wiring.
Failure to follow this instruction may result in fire. -
Do not disassemble or modify the unit.
Failure to follow this instruction may result in electric shock or fire.
Caution
-
When connecting the power/sensor input and relay output, use AWG 20(0.50mm2) cable or over, and tighten the terminal screw with a tightening torque of 0.74 to 0.90N.m.
Failure to follow this instruction may result in fire or malfunction due to contact failure. -
Use the unit within the rated specifications.
Failure to follow this instruction may result in fire or product damage. -
Use dry cloth to clean the unit, and do not use water or organic solvent.
Failure to follow this instruction may result in electric shock or fire. -
Do not use the unit in the place where flammable/explosive/corrosive gas, humidity, direct sunlight, radiant heat, vibration, impact, or salinity may be present.
Failure to follow this instruction may result in fire or explosion. -
Keep metal chip, dust, and wire residue from flowing into the unit.
Failure to follow this instruction may result in fire or product damage.
Dimensions
Counting Operation for Indicator (FM M-I4)
※- display is only for F, K, Q, S output operation mode and it cannot be set.
Input Operation Mode
-
A: over min. signal width, B: over than 1/2 of min. signal width.
If the signal is smaller than these width, it may cause counting error (±1). -
The above specifications are subject to change and some models may be discontinued without notice.
-
Be sure to follow cautions written in the instruction manual and the technical descriptions (catalog, homepage).
Specifications
Model | 1-stage setting | FM4M-1P4 | FM6M-1P4 |
---|---|---|---|
2-stage setting | FM4M-2P4 | FM6M-2P4 | |
Indicator | FM4M-I4 | FM6M-I4 | |
Display digit | 4-digit | 6-digit | |
Character size (WxH) | 6x1Omm | 4x8mm | |
Power supply | 100-240VAC– 50/60Hz | ||
Permissible voltage range | 90 to 110% of rated voltage | ||
Power consumption | • 1-stage: max. 4.6VA |
• 2-stage: max. 5.8VA
• Indicator: max. 3.8VA
Max. counting speed of CP1/CP2| Selectable lcps/30cps/300cps/2kcps/5kcps
Return time| Max. 500ms
Min. signal width| RESET: approx. 20ms
Input method| Selectable voltage input (PNP) method or no-voltage input (NPN)
method [Voltage input (PNP) method]-input impedance: max. 10.8k0,
[No-voltage input (NPN) method]-short-circuit impedance: max. 4700,
short-circuit residual voltage: max. 1VDC, open-circuit impedance: min. 100k0
One-shot output time| 0.01 to 99.99 sec
Control output| Contact| Type| • 1-stage: Instantaneous SPDT (1c)
• 2-stage: OUT1-Instantaneous SPST (la), OUT2-Instantaneous SPST (la)
Capacity| 250VAC— 3A resistive load
Solid
state| Type| • 1-stage: 1 NPN open collector
• 2-stage: OUT1-1 NPN open collector, OUT2-1 NPN open collector
Capacity| NPN open collector output
• Load voltage: max. 30VDC
• Load current: max. 100mA
• Residual voltage: max. 1VDC
Relay
life cycle| Mechanical| Min. 5,000,000 operations
Electrical| Min. 100,000 operations (250VAC 3A resistive load)
Insulation resistance| Over 100M0 (at 500VDC megger)
External power supply| Max. 12VDC ±10% 50mA
Memory retention| Approx. 10 years (non-volatile memory)
Dielectric strength| 2,000VAC 50/60Hz for 1 min (between all terminals and
case)
Noise immunity| ±2kV the square wave noise (pulse width 1ps) by noise
simulator
Vibration| Mechanical| 0.75mm amplitude at frequency 10 to 55Hz (for 1 min) in
each X, Y, Z direction for 1 hour
Malfunction| 0.5mm amplitude at frequency 10 to 55Hz (for 1 min) in each X, Y,
Z direction for 10 minutes
Shock| Mechanical| 300m/s2 (approx. 30G) in each X, Y, Z direction for 3 times
Malfunction| 100m/s2 (approx. 10G) in each X, Y, Z direction for 3 times
Environ- ment| Ambient temp.| -10 to 55°C, storage: -25 to 65°C
Ambient humi.| 35 to 85%RH, storage: 35 to 85%RH
Protection structure| IP20 (front part, IEC standard)
Approval|
Weightx’| 1-stage setting| Approx. 245g (approx. 180g)
2-stage setting| Approx. 265g (approx. 200g)
Indicator| Approx. 225g (approx. 160g)
Connections
Example of Input/ Output Connection
- When operating load by sensor power
The sum of operating current capacity of load 1 and sensor should not be over external power capacity (50mA).
When operating load by external power
- The capacity of load 1 should not be over transistor switching capacity (max. 30VDC 100mA).
- Do not supply the reverse polarity power.
※ When using inductive load (relay, etc.), connect surge absorbers at both ends of load 1.
Output Operation Mode
Parameter Setting
-
Hold the
MODE
key for 3 sec to save the setting value and return to RUN mode after changing the setting value. -
If there is no key input for 60 sec while setting the parameters, the new settings are ignored, and the unit returns to RUN mode with previous settings.
-
Press the , keys to select or set the desired value. Press the key once after changing the setting value, to save the setting value and move to the next parameter.
-
The dotted line parameters may not appear depending on output specifications or other parameter settings.
-
1: Each parameter and corresponding setting value will flash alternately every 0.5 sec.
-
2: Multiply mode [MULT]: Displayed by multiplying input signal and setting value.
Input signal×Setting value=Display value (input signal: 1, setting value: 4, it displays 4 (1×4) -
3: Divide mode [D IV]: Displays 1 when input signals are input as the setting value.
Input signal/Setting value=Display value (input signal: 4, setting value: 4, it displays 1 (4/4)
Input Connection
Voltage input (PNP)
- Solid state input (standard sensor: PNP output type sensor)
- Contact input
No-voltage input (NPN)
- Solid state input (standard sensor: NPN output type sensor)
- Contact input
Factory Default
Error Display and Output Operation
Error Display | Error description | Troubleshooting |
---|---|---|
ERR0 | Setting value is 0. | Change the setting value anything but 0. |
-
When error occurs, the output turns OFF.
-
When 1st setting value is set as 0 (zero), OUT1 maintains OFF.
When 2nd setting value is smaller than 1st setting value, 1st setting value is ignored and only OUT2 output operates. -
Indicator model does not have error display function.
Cautions during Use
-
Follow instructions in ‘Cautions during Use’. Otherwise, It may cause unexpected accidents.
-
Use the product, 0.1 sec after supplying power.
-
When supplying or turning off the power, use a switch or etc. to avoid chattering.
-
Install a power switch or circuit breaker in the easily accessible place for supplying or disconnecting the power.
-
In case of contact input, set count speed to low speed mode (1cps or 30 cps) to operate.
If set to high speed mode (300cps, 2kcps, 5kcps), counting error occurs due to chattering. -
Keep away from high voltage lines or power lines to prevent inductive noise.
In case installing power line and input signal line closely, use line filter or varistor at power line and shielded wire at input signal line.
Do not use near the equipment which generates strong magnetic force or high frequency noise. -
This product may be used in the following environments.
①Indoors (in the environment condition rated in ‘Specifications’)
②Altitude max. 2,000m
③Pollution degree 2
④Installation category II
Major Products
- Photoelectric Sensors Fiber Optic Sensors
- Door Sensors
- Door Side Sensors
- Area Sensors
- Proximity Sensors
- Pressure Sensors
- Rotary Encoders
- Connector/Sockets
- Switching Mode Power Supplies
- Control Switches/Lamps/Buzzers
- I/O Terminal Blocks & Cables
- Stepper Motors/Drivers/Motion Controllers
- Graphic/Logic Panels
- Field Network Devices
- Laser Marking System (Fiber, Co₂, Nd: YAG)
- Laser Welding/Cutting System
- Temperature Controllers
- Temperature/Humidity Transducers
- SSR/Power Controllers
- Counters
- Timers
- Panel Meters
- Tachometer/Pulse (Rate) Meters
- Display Units
- Sensor Controllers
http://www.autonics.com
HEAD QUARTERS:
18, Bansong-ro 513 beon-gil, Haeundae-gu, Busan, South
Korea, 48002
TEL: 82-51-519-3232
E-mail: sales@autonics.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>