MITSUBISHI ELECTRIC PLA-A30EA7 30000 BTU Ceiling Cassette Owner’s Manual
- June 13, 2024
- Mitsubishi Electric
Table of Contents
MITSUBISHI ELECTRIC PLA-A30EA7 30000 BTU Ceiling Cassette Owner’s Manual
GENERAL FEATURES
- Space-efficient ductless installation
- Equipped with 3D i-see Sensor® for enhanced comfort and energy efficiency
- Airflow settings for high and low ceiling applications
- Individual vane settings for direct/indirect airflow control or variable airflow patterns
- Knockouts for outside-air intake and branch-duct run
- Filter indicator signal
- Easy-to-clean, washable filter (optional high-efficiency filter available – requires multi-function casement)
- Built-in condensate lift mechanism
- Ideal for retail shops, classrooms, office spaces, conference centers, building lobbies, and more
- Multiple control options available:
- kumo cloud® smart device app for remote access
- Third-party interface options
- Wired or wireless controllers
Specifications | System |
---|---|
Unit Type | PLA-A30EA7 |
Cooling Capacity1, 3 | BTU/H |
Heating Capacity2, 3 | BTU/H |
Electrical | Voltage, Phase, Frequency |
Guaranteed Voltage Range | V AC |
Voltage: Indoor – Outdoor, S1-S2 | V AC |
Voltage: Indoor – Outdoor, S2-S3 | V DC |
Short-circuit Current Rating [SCCR] | kA |
Indoor Unit | MCA |
Fan Motor Full Load Amperage | A |
Airflow Rate at Cooling, Dry | CFM |
Airflow Rate at Cooling, Wet | CFM |
Airflow Rate at Heating, Dry | CFM |
Sound Pressure Level [Cooling] | dB[A] |
Sound Pressure Level [Heating] | dB[A] |
Drain Pipe Size | In. [mm] |
Condensate Lift Mechanism, Maximum Distance | In. [mm] |
Coating on Heat Exchanger | — |
External Finish Color | White Munsell 6.4Y 8.9/0.4 |
Unit Dimensions | W x D x H: In. [mm] |
37-13/32 x 11-3/4 // 1-9/16 [840 // 950 x 840 //950 x 298 // 40]
Package Dimensions| W x D x H: In. [mm]| 35-9/16 // 39-6/16 x 34-5/16 //
38-3/16 x 16-9/16 // 4-12/16 [903 // 1,000 x 871// 970 x 421 // 121]
Unit Weight| Lbs. [kg]| 56 // 11 [25 // 5]
Package Weight| Lbs. [kg]| 77 [35]
Refrigerant| Type| R410A
Piping| Gas Pipe Size O.D. [Flared]| In.[mm]| 5/8 [15.88]
Liquid Pipe Size O.D. [Flared]| In.[mm]| 3/8 [9.52]
Control Interface| 3-Pin Connector| □ PAC-715AD
Airzone ZBS Wired Blueface Principal Controller White| □ AZZBSBLUEFACECB
Airzone ZBS Wired Lite Controller White| □ AZZBSLITECB
Airzone ZBS Wireless Lite Controller White| □ AZZBSLITERB
Airzone ZBS Wireless Think Controller White| □ AZZBSTHINKRB
BACnet® and Modbus® Interface| □ PAC-UKPRC001-CN-1
CN24 Relay Kit| □ CN24RELAY-KIT-CM3
IT Extender| □ PAC-WHS01IE-E
kumo station® for kumo cloud®| □ PAC-WHS01HC-E
Remote Operation Adapter‡| □ PAC-SF40RM-E
Thermostat Interface| □ PAC-US445CN-1
USNAP Adapter| □ PAC-WHS01UP-E
Wireless Interface for kumo cloud®| □ PAC-USWHS002-WF-2
Remote Sensor| Flush Mount Remote Temperature Sensor| □ PAC-USSEN002-FM-1
Flush Mount Temperature Sensor| □ PAC-USSEN001-FM-1
Remote Temperature Sensor| □ PAC-SE41TS-E
Wireless temperature and humitity sensor for kumo cloud®| □ PAC-USWHS003-TH-1
Wired Remote Controller| Deluxe Wired MA Remote Controller†| □ PAR-40MAAU
Simple MA Remote Controller†| □ PAC-YT53CRAU-J
Touch MA Controller†| □ PAR-CT01MAU-SB
Wireless Remote Controller| kumo touch™ RedLINK™ Wireless Controller| □ MHK2
Lockdown bracket for remote controller| □ RCMKP1CB
Wireless MA Receiver| □ PAR-FA32MA-W
Wireless MA Remote Controller| □ PAR-FL32MA-E
Wireless Remote Contoller| □ PAR-SL101A-E
Wireless Signal Receiver Panel| □ PAR-SR4LU-E
Casement| Multi-function Casement| □ PAC-SJ41TM-E
Condensate| Blue Diamond (Advanced) Mini Condensate Pump w/ Reservoir & Sensor
(208/230V) [recommended]| □ X87-721
Blue Diamond (MegaBlue Advanced) Condensate Pump w/ Reservoir & Sensor| □
X87-835
Blue Diamond Sensor Extension Cable — 15 Ft.| □ C13-103
Refco Condensate Pump (100-240 VAC) up to 120,000 BTU/H| □ COMBI
Disconnect Switch| (30A/600V/UL) [fits 2” X 4” utility box] – Black| □ TAZ-
MS303
(30A/600V/UL) [fits 2” X 4” utility box] – White| □ TAZ-MS303W
Filter| High Efficiency Filter Element**| □ PAC-SH59KF-E
i-see Sensor® Panel| Grille with 3D i-see Sensor® (required)| □ PLP-41EAEU
Lineset| 10’ x 3/8” x 10’ x 5/8” Lineset (Twin-Tube Insulation)| □
MPLS385812T-10
100’ x 3/8” x 100’ x 5/8” Lineset (Twin-Tube Insulation)| □ MPLS385812T-100
15’ x 3/8” x 15’ x 5/8” Lineset (Twin-Tube Insulation)| □ MPLS385812T-15
30’ x 3/8” x 30’ x 5/8” Lineset (Twin-Tube Insulation)| □ MPLS385812T-30
50’ x 3/8” x 50’ x 5/8” Lineset (Twin-Tube Insulation)| □ MPLS385812T-50
65’ x 3/8” x 65’ x 5/8” Lineset (Twin-Tube Insulation)| □ MPLS385812T-65
Shutter Plate| Shutter Plate| □ PAC-SJ37SP-E
Space Panel| Space Panel| □ PAC-SJ38AS-E
NOTES:
Conditions 1
Cooling (Indoor // Outdoor) °F 80 DB, 67 WB // 95 DB, 75 WB 2
Heating at 47°F (Indoor // Outdoor) °F 70 DB, 60 WB // 47 DB, 43 WB
3 Capacity varies based on the number of indoor units operating and the model
of the Multi-zone Outdoor Unit. For reference to connected capacity charts,
please refer Multi-zone Outdoor Unit Operational
Performance
NOTES:
‡ PAC-SF40RM-E (Unable to use with wireless remote controller)
MODELS | A | B | C | D | E | F | ||
---|---|---|---|---|---|---|---|---|
12/18 | FLARED CONNECTION 1/4F | REFRIGERANT PIPE{ FLARED CONNECTION 1/2F | ||||||
(241) | 10-3/16 (258) | 3(76) | 10-7/16(265) OR MORE | 137-13/16(3500) OR LESS | ||||
24/30/36/42 | FLARED CONNECTION 3/8F | REFRIGERANT PIPE{ FLARED CONNECTION 5/8F | ||||||
11-1/16 (281) | 11-3/4 | 3-1/8 | 12(305) OR MORE | 177-3/16(4500 ) OR LESS |
1340 Satellite Boulevard Suwanee, GA 30024
Toll Free: 800-433-4822
www.mehvac.com
Specifications are subject to change without notice. © 2023 Mitsubishi Electric Trane HVAC US LLC. All rights reserved.
Specifications are subject to change without notice.
© 2023 Mitsubishi Electric Trane HVAC US LLC. All rights reserved.
FORM# PLA-A30EA7R1.TH – 202302
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>