sauermann Si-CPE320 Multifunction Panel Transmitter User Guide

June 13, 2024
sauermann

sauermann Si-CPE320 Multifunction Panel Transmitter

Product Information

The Si-CPE320 is a radio equipment type transmitter manufactured by Sauermann Industrie SAS. It is compliant with Directive2014/53/EU. The transmitter is designed for mounting on a wall and  is equipped with IP66 protection. It requires electrical connections as per NFC15-100 standard and can be powered by eithera 24 VDC or 24 VAC power supply. The transmitter also features a regulator display or PLC/BMS passive type compatibility.

Specifications

  • Model: XXXXX
  • Serial Number: XXXXXX
  • Build: X
  • Version: 5.02

Languages:

  • English
  • Spanish
  • German
  • Chinese
  • French
  • Italian
  • Portuguese

Continents:

  • Africa
  • North America
  • APAC (Asia-Pacific)
  • Europe LATAM (Latin America)
  • Europe Northern
  • Europe Southern
  • Europe Western
  • Middle East
  • Rest Of Europe

Product Usage Instructions

  1. To mount the transmitter on a wall:
    • Make a cutting of 200 x 82 mm in the wall.
    • Drill 4 holes around the cutting as shown in the diagram.
    • Insert the transmitter into the wall and fix it with the 4 screws provided.
    • To ensure IP66 protection, use silicone sealant between the wall and the transmitter.
    • If using vaporized hydrogen peroxide (VHP), ensure that the seal is VHP resistant.
  2. To make electrical connections:
    • Follow the NFC15-100 standard.
    • This must be done by a formed and qualified technician.
    • Ensure that the transmitter is not energized during the connection process.
    • A switch or circuit breaker upstream of the device is compulsory.
  3. First Start-up:
    • Tap “Start settings” to begin the setup process.
    • Select your language and tap “Next”.
    • Set your time and time zone.
    • Connect the probe(s) before configuring the channel(s).
  4. Probe Connection/Disconnection:
    • To connect a probe to the Si-CPE320 transmitter, follow the provided instructions.

Quick Start Guide
These operating instructions describe the basic handling of the device. Please refer to the operating instructions available at sauermanngroup.com for safe use of the product and detailed information. Do not give this device to a child.

Symbols used
For your safety and in order to avoid any damage of the device, please read carefully the notes preceded by the following symbol:

Description of the device, operating temperature, protection of the instruments and information about storage

The Si-CPE320 is a transmitter that can measure simultaneous parameters including differential pressure, temperature (Pt100 and thermocouple), hygrometry, air quality (CO/CO2/VOC), air velocity, and airflow.

  • Operating temperature : -10 to 50°C (14 to 122°F)
  • Protection : IP66 , resistant to VHP*
  • Storage temperature : -10 to 70°C (14 to 158°F)

Directive 2014/53/EU
Hereby, Sauermann Industrie SAS declares that the radio equipment type Si- CPEC320 is in compliance with Directive 2014/53/EU. The full text of the EU declaration of conformity is available at the following internet address: sauermanngroup.com

Mounting
To install a transmitter on a wall, make a cutting of 200 x 82 mm in the wall. Then drill 4 holes around the cutting as shown beside. Insert the transmitter into the wall and fix it with the 4 screws (supplied with the transmitter).

To ensure IP66 protection, use sealant of silicone type between the wall and the transmitter. If VHP* is used, check that the seal is VHP resistant.

Connections

sauermann-Si-CPE320-Multifunction-Panel-Transmitter-fig-
\(2\)

Electrical connections as per NFC15-100 standard

This connection must be made by a formed and qualified technician. Whilst making the connection, the transmitter must not be energized. The presence of a switch or a circuit breaker upstream the device is compulsory.

CPE320

First start-up

sauermann-Si-CPE320-Multifunction-Panel-Transmitter-fig-
\(4\) sauermann-Si-CPE320
-Multifunction-Panel-Transmitter-fig- \(5\)

  • Tap ‘’Start settings’’.
  • Select your language and tap ‘’Next’’.
  • Tap your required continent.
  • Tap the required area.
  • The transmitter is set. You can connect a probe to set a channel.
  • Set your time and tap ‘’Next’’.
  • Set your time zone and tap ‘’Next’’.
  • Set the date and tap ‘’Next’’.
  • Tap the required country then ‘’Next’’.

Probe connection/disconnection

Connect a probe to the Si-CPE320 transmitter

  • On the back of the transmitter, present the probe connector (a) with its arrow and padlock face to the transmitter connector (b).
  • Push in the probe connector (a) into the transmitter connector (b) until you hear a click. The probe is correctly connected.sauermann-Si-CPE320-Multifunction-Panel-Transmitter-fig- \(6\)

Disconnect a probe from the Si-CPE320 transmitter

  • Turn the ring (c) of the probe connector to the left.
  • Pull the probe connector (a) away from the transmitter connector (b). sauermann-Si-CPE320-Multifunction-Panel-Transmitter-fig- \(7\)

Set a channel

sauermann-Si-CPE320-Multifunction-Panel-Transmitter-fig-
\(8\)

  • Connect a probe to set a channel and tap ‘’Next’’.
  • The list of available channel is displayed. Tap the required channel.
  • Tap ‘’PROBE 1’’ or ‘’MODULE’’. Parameters to set are now available.
  • Set the parameters according to your needs then tap the back arrow on the top left
  • Channel two is configured. Tap next to configure outputs

Set an output

sauermann-Si-CPE320-Multifunction-Panel-Transmitter-fig-
\(9\)

  • Tap the output to set corresponding to the previously configured channel.
  • Activate the output taping Set the output type and high and low range values then tap the back arrow on the top left.
  • Tap ‘’Next’’ to display measures.

Maintenance

  • Please avoid any aggressive solvents.
  • Please protect the transmitter and its probes from any cleaning product containing formalin, that may be used for cleaning rooms or ducts.

Precautions for use
Please always use the device in accordance with its intended use and within parameters described in the user manual in order not to compromise the protection ensured by the device.

Make the most of your device’s capabilities by downloading the app.

Access all documentation about the device.

sauermann

Customer service portal
Use our Customer service portal to contact us https://sauermann- en.custhelp.com

sauermanngroup.com

QSG  Si-CPE320
01/09/2023

Non-contractual document
We reserve the right to modify the characteristics of our products without prior notice

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals