dalap 125 ONYX Black Bathroom Fan Closet User Manual

June 13, 2024
dalap

dalap 125 ONYX Black Bathroom Fan Closet

Dalap 125 ONYX Black Bathroom Fan Closet

Attention!

One-phase main, to which the fan is connected, must correspond to the norms in force. Stationary electric wiring must be equipped with an automatic circuit breaker. The connection is carried out through the switch that is built into the stationary wiring. The gap between switch contacts at all poles must be not less than 3 mm. In the option is built in the fan. Before installation, it is necessary to make sure that there is no visible damage of impeller, case, grill, and the flow passage of the case has no any extraneous things, which may damage impeller blades.

Correct use:

Axial duct domestic electric fan, axial duct domestic removable electric fan is designed to remove odors and excess moisture from toilets, bathrooms and other small rooms, required ventilation.

Maintenance:

  • disconnect the fan from the mains;
  • remove the fan by disconnecting it from the duct and removed from the installation place.
  • in case of heavy soiling, remove the fan impeller;
  • wipe all plastic components with a soft cloth soaked in soapy water, it is not allowed transfer of washing solution to the motor
  • wipe all surfaces dry
  • assemble a fan and set it in place.

Storage and transportation:

Keep the fan only in the packaging of the manufacturer in a ventilated room at a temperature of +5 ° C to +40 ° C and relative humidity of 80% (at T = 25 ° C). Keeping time – 5 years from date of manufacture. Products transported by any transport provided consumer protection or transport container from the direct effects of rainfall, lack of bias transport places during transport, the lack of mutual physical impact during transportation and preservation of fans. Transportation is carried out in force with the rules for this transport

Dalap ONYX Connection:

  • remove the decorative front panel
  • strip the insulation on 5-7 mm from the wire end
  • hold the power wire through the cable hole in the case
  • insert wires into terminal box and press them by tap screw
  • fix the panel with screw

Main Technical characteristics and connection details:

Characteristics ONYX 100 ONYX 125
Flange d1am1eter (mm) l 00 125
Efficiency (m3/h) l 00 180
Power consumption (W) 14 16
Noise level (1 B) 32 33
Weight (kg) 0,47 0,62
Current (A) 0,06 0,06
IP 24 24

Dimension

Dimension

Model| d| A| B| X| Y| E| F*|

C

---|---|---|---|---|---|---|---|---

ONVX100

| 100| 170| 170| 135| 135| 74| 6| 38

ONYX 125

| 125| 200| 200| 160| 160| 79| 6|

38

Dimensiondalap-
Logo

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals