rogerseller 3639000101 Floormount Basin Outlet Installation Guide

June 13, 2024
rogerseller

rogerseller 3639000101 Floormount Basin Outlet Installation Guide

Specifications

It is a requirement of State Plumbing Codes that licensed plumbers carry out all tapware installations. All installations should comply with the relevant requirements of AS/NZS 3500 and local plumbing codes.

Pressure:
[1] Maximum Hydrostatic Pressure: 1000kpa. This pressure may be exceeded only under test conditions as per AS/NZS 3500. Where hydrostatic pressure exceeds the maximum stated above, pressure-limiting valves should be installed. [2] Recommended Maximum Hydrostatic Pressure: 500kpa (AS/NZS 3500). [3] Recommended Minimum Hydrostatic Pressure: 150kpa

Temperature:
Maximum Water Temperature: 80° C. For optimum performance, hot and cold inlet water pressure should be equal.

Care and Maintenance

[1] Product should be inspected for surface damage prior to installation. [2] Cleaning and handling of all finishes must be performed carefully. [3] Clean products using a soft cloth with warm soapy water only. [4] Never use harsh detergents or abrasive cleaners as these will damage the product. [5] Water marks can be removed from Matt Finishes with an application of a carnauba wax based non-abrasive polish on a microfibre cloth. [6] Do not use undue pressure when cleaning and wipe in one direction only. [7] Contact with harsh chemicals such as hair dye, hair bleach etc with result in damage to the finish. [8] Tapware should never be installed using acetone silicones. [9] Avoid the use of wax based furniture creams as this can result in a build up of deposits which will detract from the appearance. [10] Rose Copper: A protective lacquer has been applied to this finish. This is required to maintain the stability of this finish and will be damaged if the above care and cleaning instructions are not followed. [11] Damage to finishes arising from improper installation or post installation use or failure to observe the above care and cleaning instructions will void all warranty agreements.

Installation

  1. The Floormount Outlet requires a male 1/2” BSP fitting to protude through the finished floor surface.

  2. Prior to fitting the Floormount Outlet, ensure the floor surface is completely sealed and watertight.

  3. Upon receiving, remove the floor fitting from the Outlet by loosening the Set Screw.

  4. Fit the Floor Fitting to the 1/2” BSP male thread protruding through the finished floor surface.
    Note: Additional anchoring points are provided within the floor fitting.

  5. Once the floor fitting has been tightened, fit the Cover Flange.

  6. Ensure the O-Rings are intact and then gently lower the Outlet over the floor fitting.

  7. The Outlet is pushed over the fitting passing through the Cover Flange until the base of the Outlet rests on the floor fitting.

  8. Position the Outlet in the desired direction and then secure by tightening the Set Screw.
    Note: Apply Thread Sealant to set screw before final fit off.

  9. Once installed, check function of the Outlet and check for water leaks.