rogerseller 3606013201 Eccentric Wall Mixer and Bath Outlet Chrome Instruction Manual

June 9, 2024
rogerseller

rogerseller 3606013201 Eccentric Wall Mixer and Bath Outlet Chrome Instruction Manual
rogerseller 3606013201 Eccentric Wall Mixer and Bath Outlet
Chrome

Eccentric by Rogerseller Wall Mixer with Outlet

Chrome

Other finishes available

Bath Outlet 3606013201
Basin Outlet 3606013301

Parts List

Parts List

  1. In-Wall Body/Assembly
  2. Ceramic Cartridge
  3. Splined Valve Stem
  4. Lock-nut
  5. Spline Extension
  6. Screw
  7. Wall Plate O-ring
  8. Wall Plate
  9. Flange Washer
  10. Flange
  11. Handle
  12. Handle Screw
  13. Handle Button
  14. Hot Indicator
  15. Push-fit Wall Plate
  16. Outle

Optional Extras
For installations with a greater finished wall depth:
20mm Extended Body 3606005200IW
For installations with minimal finished wall depth:
Horizontal In-Wall Mounting Bracket 3612000100

Pre-Installation

Checklist

  • Flush to remove any foreign matter from plumbing lines.
  • Ensure mixer is in the closed position during installation and testing.
  • In-line filters are recommended to ensure clean flow of water to the mixer.

Mounting

When mounting the body onto the wall frame, take note of the dimensions shown so the mixer is correctly positioned with the finished wall

Min/Max: 80–100mm Diameter hole: 42–55mm

Mixer body must be installed level and square to the wall with the outlet connection horizontal to ensure correct handle orientation.

Water Supply

Connect water supply to points as illustrated ,right. Do not apply heat to the mixer or pipework connected near the mixer. Damage to the ceramic cartridge caused by heat near the mixer will void the warranty
Water Supply

Note: Mixer in-wall must be installed level and square to the finished wall.

In-wall supplied with a protective cover. Do Not remove until all works complete and ready for handle fitment.

Installation

Step 1 Install the spline extension onto the valve stem if not already done so.
Installation
Step 2 Trimming spline extension: Measure 27–28mm from the finished wall and trim spline extension at this finish point.
Installation
Step 3 Place the wall plate with O-ring over the body making sure the “C” & “H” located correctly as shown in diagram.
Installation
Step 4 Place flange washer over the flange and screw flange on the body through the wall plate clockwise until the wall plate flush with the finished wall, as shown.
Installation

Step 5 Locate the handle and tighten handle screw with 2.5mm allen key. If the handle isn’t horizontal, remove the handle and mark both the valve stem and spindle extension. Remove extension and reposition by rotating one tooth at a time until horizontal is achieved. Tighten handle screw clockwise with 2.5mm allen key supplied and push in handle button until flush with handle.
Note: to remove handle, push the button into handle to access screw.

Step 6 Apply the push-fit wall plate to the outlet. Screw the outlet onto the in-wall assembly until level with the wall. Push the wall plate up against the finished wall to complete the installation.
Installation

Step 7 Prior to introducing mains supply it is mandatory that lines are flushed. Open handle in the mixed position – midway between “C” & “H” and ensure the aerator is removed from outlet

Templates

Plumbers Template (Mixer Orientation)
Ensure if pairing with outlet to note offset nature of handle when roughing in. Please refer to handle orientation and template for offset location.

Tilers Template (Hole Cut Out)
Installation

Specifications

It is a requirement of state plumbing codes that licensed plumbers carry out all tapware installations. All installations must comply with the relevant requirements of AS/NZS3500 and local plumbing codes.

Pressure

Maximum Hydrostatic Pressure – 1000kpa Recommended Maximum Hydrostatic Pressure – 500 kpa. (AS/NZS 3500) Recommended Minimum Hydrostatic Pressure – 150 kpa. Maximum Hydrostatic Pressure may be exceeded under test conditions only in accordance with AS/ NZS 3500. Where hydrostatic pressure exceeds the maximum stated above, pressure limiting valves must be installed or warranty will be void.

Temperature

Maximum Water Temperature – 80°C For optimum performance, Hot and Cold inlet water pressure should be equal.

Care and Maintenance

[1] Product should be inspected for surface damage prior to installation. [2] Cleaning and handling of all finishes must be performed carefully. [3] Clean products using a soft cloth with warm soapy water only. [4] Never use harsh detergents or abrasive cleaners as these will damage the product. [5] Water marks can be removed from Matt Finishes with an application ofa carnauba wax based non-abrasive polish on a microfibre cloth. [6] Do not use undue pressure when cleaning and wipe in one direction only. [7] Contact with harsh chemicals such as hair dye, hair bleach etc will result in damage to the finish. [8] Tapware should never be installed using acetone silicones. [9] Avoid the use of wax based furniture creams as this can result in a build up of deposits which will detract from the appearance. [10] Damage to finishes arising from improper installation  or post installation use or failure to observe the above care and cleaning instructions will void all warranty agreements

Warranty

Rogerseller tapware, bathroom fittings and sanitaryware are covered by a  five (5) year warranty from date of purchase. For full terms and conditions please refer to rogerseller.com.au

Dimensions are approximate. Information in this installation instruction is representative of the product available at the time of printing. Due to our policy of continuous product development, the design and specifications depicted are subject to change without notice. Please confirm all particulars with your client advisor prior to purchase.

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

rogerseller User Manuals

Related Manuals