Lamborghini 3QE46180 Split Type Room Air Conditioner Owner’s Manual
- June 13, 2024
- Lamborghini
Table of Contents
- 3QE46180 Split Type Room Air Conditioner
- Safety Precautions
- CLEANING AND MAINTENANCE WARNINGS
- Unit Specifications and Features
- Care and Maintenance
- Troubleshooting
- Accessories
- Installation Summary – Indoor Unit
- Unit Parts
- Indoor Unit Installation
- Outdoor Unit Installation
- Refrigerant Piping Connection
- Air Evacuation
- Electrical and Gas Leak Checks
- Test Run
- Packing and unpacking the unit
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
AZIENDA CERTIFICATA ISO 9001
SPLIT-TYPE ROOM AIR CONDITIONER
PERLA
OWNER’S MANUAL & INSTALLATION MANUAL
3QE46180 Split Type Room Air Conditioner
IMPORTANT NOTE:
Read this manual and SAFETY MANUAL(if any) carefully before installing or
operating your new air conditioning unit. Make sure to save this manual for
future reference.
Please check the applicable models, technical data, F-GAS(if any) and
manufacturer information from the “Owner’s Manual – Product Fiche ” in the
packaging of the outdoor unit (European Union products only) or in the
packaging of the indoor unit (model dependent)
Safety Precautions
Read Safety Precautions Before Operation and Installation Incorrect
installation due to ignoring instructions can cause serious damage or injury.
The seriousness of potential damage or injuries is classified as either a
WARNING or CAUTION
WARNING
This symbol indicates the possibility of personnel injury or loss of life.
CAUTION
This symbol indicates the possibility of property damage or serious
consequences.
WARNING
This appliance can be used by children aged from 8 years and above and persons
with reduced physical, sensory or mental capabilities or lack of experience
and knowledge if they have been given supervision or instruction concerning
use of the appliance in a safe way and understand the hazards involved.
Children shall not play with the appliance. Cleaning and user maintenance
shall not be made by children without supervision(European Union countries).
This appliance is not intended for use by persons(including children) with
reduced physical, sensory or mental capabilities, or lack of experience and
knowledge, unless they have been given supervision or instruction concerning
use of the appliance by a person responsible for their safety. Children should
be supervised to ensure that they do not play with the appliance.
WARNINGS FOR PRODUCT USE
- If an abnormal situation arises (like a burning smell), immediately turn off the unit and disconnect the power. Call your dealer for instructions to avoid electric shock, fire or injury.
- Do not insert fingers, rods or other objects into the air inlet or outlet. This may cause injury, since the fan may be rotating at high speeds.
- Do not use flammable sprays such as hair spray, lacquer or paint near the unit. This may cause fire or combustion.
- Do not operate the air conditioner in places near or around combustible gases. Emitted gas may collect around the unit and cause explosion.
- Do not operate your air conditioner in a wet room such as a bathroom or laundry room. Too much exposure to water can cause electrical components to short circuit.
- Do not expose your body directly to cool air for a prolonged period of time.
- Do not allow children to play with the air conditioner. Children must be supervised around the unit at all times.
- If the air conditioner is used together with burners or other heating devices, thoroughly ventilate the room to avoid oxygen deficiency.
- In certain functional environments, such as kitchens, server rooms, etc., the use of specially designed air-conditioning units is highly recommended.
CLEANING AND MAINTENANCE WARNINGS
- Turn off the device and disconnect the power before cleaning. Failure to do so can cause electrical shock.
- Do not clean the air conditioner with excessive amounts of water.
- Do not clean the air conditioner with combustible cleaning agents. Combustible cleaning agents can cause fire or deformation.
CAUTION
- Turn off the air conditioner and disconnect the power if you are not going to use it for a long time.
- Turn off and unplug the unit during storms.
- Make sure that water condensation can drain unhindered from the unit.
- Do not operate the air conditioner with wet hands. This may cause electric shock.
- Do not use device for any other purpose than its intended use.
- Do not climb onto or place objects on top of the outdoor unit.
- Do not allow the air conditioner to operate for long periods of time with doors or windows open, or if the humidity is very high.
ELECTRICAL WARNINGS
- Only use the specified power cord. If the power cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.
- Keep power plug clean. Remove any dust or grime that accumulates on or around the plug. Dirty plugs can cause fire or electric shock.
- Do not pull power cord to unplug unit. Hold the plug firmly and pull it from the outlet. Pulling directly on the cord can damage it, which can lead to fire or electric shock.
- Do not modify the length of the power supply cord or use an extension cord to power the unit.
- Do not share the electrical outlet with other appliances. Improper or insufficient power supply can cause fire or electrical shock.
- The product must be properly grounded at the time of installation, or electrical shock may occur.
- For all electrical work, follow all local and national wiring standards, regulations, and the Installation Manual. Connect cables tightly, and clamp them securely to prevent external forces from damaging the terminal. Improper electrical connections can overheat and cause fire, and may also cause shock. All electrical connections must be made according to the Electrical Connection Diagram located on the panels of the indoor and outdoor units.
- All wiring must be properly arranged to ensure that the control board cover can close properly. If the control board cover is not closed properly, it can lead to corrosion and cause the connection points on the terminal to heat up, catch fire, or cause electrical shock.
- If connecting power to fixed wiring, an all-pole disconnection device which has at least 3mm clearances in all poles, and have a leakage current that may exceed 10mA, the residual current device(RCD) having a rated residual operating current not exceeding 30mA, and disconnection must be incorporated in the fixed wiring in accordance with the wiring rules.
TAKE NOTE OF FUSE SPECIFICATIONS
The air conditioner’s circuit board (PCB) is designed with a fuse to provide
overcurrent protection.
The specifications of the fuse are printed on the circuit board ,such as :
T3.15AL/250VAC, T5AL/250VAC, T3.15A/250VAC, T5A/250VAC, T20A/250VAC,
T30A/250VAC,etc.
NOTE: For the units using R32 or R290 refrigerant , only the blast-proof
ceramic fuse can be used.
UV-C lamp(Applicable to the unit contains an UV-C lamp only)
This appliance contains a UV-C lamp. Read the maintenance instructions before
opening the appliance.
- Do not operate UV-C lamps outside of the appliance.
- Appliances that are obviously damaged must not be operated.
- Unintended use of the appliance or damage to the housing may result in the escape of dangerous UV-C radiation. UV-C radiation may, even in small doses, cause harm to the eyes and skin.
- Before opening doors and access panels bearing the ULTRAVIOLET RADIATION hazard symbol for the conducting USER MAINTENANCE, it is recommended to disconnect the power.
- The UV-C lamp can not be cleaned, repaired and replaced.
- UV-C BARRIERS bearing the ULTRAVIOLET RADIATION hazard symbol should not be removed.
WARNING This appliance contains an UV emitter. Do not stare at the light source.
WARNINGS FOR PRODUCT INSTALLATION
-
Installation must be performed by an authorized dealer or specialist. Defective installation can cause water leakage, electrical shock, or fire.
-
Installation must be performed according to the installation instructions. Improper installation can cause water leakage, electrical shock, or fire.
(In North America, installation must be performed in accordance with the requirement of NEC and CEC by authorized personnel only.) -
Contact an authorized service technician for repair or maintenance of this unit. This appliance shall be installed in accordance with national wiring regulations.
-
Only use the included accessories, parts, and specified parts for installation. Using non-standard parts can cause water leakage, electrical shock, fire, and can cause the unit to fail.
-
Install the unit in a firm location that can support the unit’s weight. If the chosen location cannot support the unit’s weight, or the installation is not done properly, the unit may drop and cause serious injury and damage.
-
Install drainage piping according to the instructions in this manual. Improper drainage may cause water damage to your home and property.
-
For units that have an auxiliary electric heater, do not install the unit within 1 meter (3 feet) of any combustible materials.
-
Do not install the unit in a location that may be exposed to combustible gas leaks. If combustible gas accumulates around the unit, it may cause fire.
-
Do not turn on the power until all work has been completed.
-
When moving or relocating the air conditioner, consult experienced service technicians for disconnection and reinstallation of the unit.
-
How to install the appliance to its support, please read the information for details in “indoor unit installation” and “outdoor unit installation” sections .
Note about Fluorinated Gasses(Not applicable to the unit using R290 Refrigerant)
- This air-conditioning unit contains fluorinated greenhouse gasses. For specific information on the type of gas and the amount, please refer to the relevant label on the unit itself or the “Owner’s Manual – Product Fiche ” in the packaging of the outdoor unit. (European Union products only).
- Installation, service, maintenance and repair of this unit must be performed by a certified technician.
- Product uninstallation and recycling must be performed by a certified technician.
- For equipment that contains fluorinated greenhouse gases in quantities of 5 tonnes of CO2 equivalent or more, but of less than 50 tonnes of CO2 equivalent, If the system has a leak detection system installed, it must be checked for leaks at least every 24 months.
- When the unit is checked for leaks, proper record-keeping of all checks is strongly recommended.
WARNING for Using R32/R290 Refrigerant
-
When flammable refrigerant are employed, appliance shall be stored in a well -ventilated area where the room size corresponds to the room area as specific for operation. For R32 frigerant models:
Appliance shall be installed, operated and stored in a room with a floor area larger than 4m .
For R290 refrigerant models, appliance shall be installed, operated and stored in a room with a floor area larger than:
<=9000Btu/h units: 13m²9000Btu/h and <=12000Btu/h units: 17m²
12000Btu/h and <=18000Btu/h units: 26m²
18000Btu/h and <=24000Btu/h units: 35m² -
Reusable mechanical connectors and flared joints are not allowed indoors.
(EN Standard Requirements). -
Mechanical connectors used indoors shall have a rate of not more than 3g/year at 25% of the maximum allowable pressure. When mechanical connectors are reused indoors, sealing parts shall be renewed. When flared joints are reused indoors, the flare part shall be re-fabricated. (UL Standard Requirements)
-
When mechanical connectors are reused indoors, sealing parts shall be renewed. When flared joints are reused indoors, the flare part shall be re-fabricated. (IEC Standard Requirements)
-
Mechanical connectors used indoors shall comply with ISO 14903.
European Disposal Guidelines
This marking shown on the product or its literature, indicates that waste
electrical and electrical equipment should not be mixed with general household
waste.
Correct Disposal of This Product
(Waste Electrical & Electronic Equipment)
This appliance contains refrigerant and other potentially hazardous materials.
When disposing of this appliance, the law requires special collection and
treatment. Do not dispose of this product as household waste or unsorted
municipal waste.
When disposing of this appliance, you have the following options:
- Dispose of the appliance at designated municipal electronic waste collection facility.
- When buying a new appliance, the retailer will take back the old appliance free of charge.
- The manufacturer will take back the old appliance free of charge.
- Sell the appliance to certified scrap metal dealers.
Special notice
Disposing of this appliance in the forest or other natural surroundings
endangers your health and is bad for the environment. Hazardous substances may
leak into the ground water and enter the food chain.
Unit Specifications and Features
Indoor unit display
NOTE: Different models have different front panels and display windows.
Not all the display codes describing below are available for the air
conditioner you purchased. Please check the indoor display window of the unit
you purchased.
Illustrations in this manual are for explanatory purposes. The actual shape of
your indoor unit may be slightly different. The actual shape shall prevail.
Operating temperature
When your air conditioner is used outside of the following temperature ranges,
certain safety protection features may activate and cause the unit to disable.
Inverter Split Type
| COOL mode| HEAT mode| DRY mode
---|---|---|---
Room Temperature| 16°C – 32°C (60°F – 90°F)| 0°C – 30°C (32°F – 86°F)| 10°C –
32°C (50°F – 90°F)
Outdoor
Temperature| 0°C – 50°C
(32°F – 122°F)| -15°C – 24°C (5°F – 75°F)| 0°C – 50°C (32°F – 122°F)
-15°C – 50°C (5°F – 122°F)
(For models with low temp. cooling systems.)
0°C – 52°C (32°F – 126°F)
(For special tropical models)| 0°C – 52°C
(32°F – 126°F)
(For special tropical models)
FOR OUTDOOR UNITS WITH AUXILIARY ELECTRIC HEATER
When outside temperature is below 0°C (32°F ), we strongly recommend keeping
the unit plugged in at all time to ensure smooth ongoing performance.
Fixed-speed Type
| COOL mode| HEAT mode| DRY mode
---|---|---|---
Room
Temperature| 16°C-32°C (60°F-90°F)| 0°C-30°C
(32°F-86°F)| 10°C-32°C (50°F-90°F)
Outdoor
Temperature| 18°C-43°C (64°F-109°F)| -7°C-24°C
(19°F-75°F)| 11°C-43°C (52°F-109°F)
-7°C-43°C (19°F-109°F)
(For models with low-temp cooling systems)| 18°C-43°C (64°F-109°F)
18°C-52°C (64°F-126°F)
(For special tropical models)| 18°C-52°C (64°F-126°F)
(For special tropical models)
NOTE: Room relative humidity less than 80%. If the air conditioner operates in excess of this figure, the surface of the air conditioner may attract condensation. Please sets the vertical air flow louver to its maximum angle (vertically to the floor), and set HIGH fan mode.
To further optimize the performance of your unit, do the following:
- Keep doors and windows closed.
- Limit energy usage by using TIMER ON and TIMER OFF functions.
- Do not block air inlets or outlets.
- Regularly inspect and clean air filters.
A guide on using the infrared remote is not included in this literature package. Not all the functions are available for the air conditioner, please check the indoor display and remote control of the unit you purchased.
Other Features
-
Auto-Restart(some units)
If the unit loses power, it will automatically restart with the prior settings once power has been restored. -
Anti-mildew (some units)
When turning off the unit from COOL, AUTO (COOL), or DRY modes, the air conditioner will continue operate at very low power to dry up condensed water and prevent mildew growth. -
Wireless Control (some units)
Wireless control allows you to control your air conditioner using your mobile phone and a wireless connection.
For the USB device access, replacement, maintenance operations must be carried out by professional staff. -
Louver Angle Memory(some units)
When turning on your unit, the louver will automatically resume its former angle. -
Active Clean function(some units)
— The Active Clean Technology washes away dust when it adheres to the heat exchanger by automatically freezing and then rapidly thawing the frost. A “pi- pi” sound will be heard.
The Active clean operation is used to produce more condensed water to improve the cleaning effect, and the cold air will blow out. After cleaning, the internal wind wheel then keeps operating with hot air to blow-dry the evaporator, thus keeping the inside clean.
— When this function is turned on, the indoor unit display window appears “CL ” , after 20 to 130 minutes, the unit will turn off automatically and cancel Active Clean function.
— For some units, the system will start high temperature cleaning process, and the temperature of air outlet is very high.
Please keep away from it. And this would lead to the rising of the room temperature . -
Breeze Away (some units)
This feature avoids direct air flow blowing on the body and make you feel indulging in silky coolness. -
Refrigerant Leakage Detection (some units)
The indoor unit will automatically display “EL0C”or flash LEDS (model dependent ) when it detects refrigerant leakage. -
Sleep Operation
The SLEEP function is used to decrease energy use while you sleep (and don’t need the same temperature settings to stay comfortable). This function can only be activated via remote control. And the Sleep function is not available in FAN or DRY mode.
Press the SLEEP button when you are ready to go to sleep. When in COOL mode, the unit will increase the temperature by 1°C (2°F) after 1 hour, and will increase an additional 1°C (2°F) after another hour When in HEAT mode, the unit will decrease the temperature by 1°C (2°F) after 1 hour and will decrease an additional 1°C (2°F) after another hour.
The sleep feature will stop after 8 hours and the system will keep running with final situation.
NOTE:
For multi-split air conditioners, the following functions are not available:
Active clean function, Silence feature, Breeze away function, Refrigerant
leakage detection function and Eco feature.
Setting Angle of Air Flow
Setting vertical angle of air flow
While the unit is on, use the SWING/DIRECT button on remote control to set the
direction (vertical angle) of airflow. Please refer to the Remote Control
Manual for details.
NOTE ON LOUVER ANGLES
When using COOL or DRY mode, do not set louver at too vertical an angle for
long periods of time. This can cause water to condense on the louver blade,
which will drop on your floor or furnishings.
When using COOL or HEAT mode, setting the louver at too small an angle can
reduce the performance of the unit due to restricted air flow.
NOTE: According to the relative standards requirement, please sets the
vertical air flow louver to its maximum angle under heating capacity test.
Setting horizontal angle of air flow
The horizontal angle of the airflow must be set manually. Grip the deflector
rod (See Fig. B) and manually adjust it to your preferred direction.
For some units, the horizontal angle of the airflow can be set by remote
control. please refer to the Remote Control Manual.
Manual Operation(without remote)
CAUTION
The manual button is intended for testing purposes and emergency operation
only. Please do not use this function unless the remote control is lost and it
is absolutely necessary. To restore regular operation, use the remote control
to activate the unit. Unit must
be turned off before manual operation.
To operate your unit manually:
- Open the front panel of the indoor unit.
- Locate the MANUAL CONTROL button on the right-hand side of the unit.
- Press the MANUAL CONTROL button one time to activate FORCED AUTO mode.
- Press the MANUAL CONTROL button again to activate FORCED COOLING mode.
- Press the MANUAL CONTROL button a third time to turn the unit off.
- Close the front panel.
NOTE: Do not move louver by hand. This will cause the louver to become
out of sync. If this occurs, turn off the unit and unplug it for a few
seconds, then restart the unit. This will reset the louver.
Fig. A
CAUTION
Do not put your fingers in or near the blower and suction side of the unit.
The high-speed fan inside the unit may cause injury.
Care and Maintenance
Cleaning Your Indoor Unit
BEFORE CLEANING OR MAINTENANCE
ALWAYS TURN OFF YOUR AIR CONDITIONER SYSTEM AND DISCONNECT ITS POWER SUPPLY
BEFORE CLEANING OR MAINTENANCE.
CAUTION
Only use a soft, dry cloth to wipe the unit clean.
If the unit is especially dirty, you can use a cloth soaked in warm water to
wipe it clean.
- Do not use chemicals or chemically treated cloths to clean the unit
- Do not use benzene, paint thinner, polishing powder or other solvents to clean the unit. They can cause the plastic surface to crack or deform.
- Do not use water hotter than 40°C (104°F) to clean the front panel. This can cause the panel to deform or become discolored.
Cleaning Your Air Filter
A clogged air conditioner can reduce the cooling efficiency of your unit, and
can also be bad for your health. Make sure to clean the filter once every two
weeks.
- Lift the front panel of the indoor unit.
- First press the tab on the end of filter to loosen the buckle, lift it up, then pull it towards yourself.
- Now pull the filter out.
- If your filter has a small air freshening filter, unclip it from the larger filter. Clean this air freshening filter with a hand-held vacuum.
- Clean the large air filter with warm, soapy water. Be sure to use a mild detergent.
- Rinse the filter with fresh water, then shake off excess water.
- Dry it in a cool, dry place, and refrain from exposing it to direct sunlight.
- When dry, re-clip the air freshening filter to the larger filter, then slide it back into the indoor unit.
- Close the front panel of the indoor unit.
CAUTION
Do not touch air freshening (Plasma) filter for at least 10 minutes after
turning off the unit.
CAUTION
- Before changing the filter or cleaning, turn off the unit and disconnect its power supply.
- When removing filter, do not touch metal parts in the unit. The sharp metal edges can cut you.
- Do not use water to clean the inside of the indoor unit. This can destroy insulation and cause electrical shock.
- Do not expose filter to direct sunlight when drying. This can shrink the filter.
Air Filter Reminders (Optional)
Air Filter Cleaning Reminder
After 240 hours of use, the display window on the indoor unit will flash “CL.”
This is a reminder to clean your filter. After 15 seconds, the unit will
revert to its previous display.
To reset the reminder, press the LED button on your remote control 4 times, or
press the MANUAL CONTROL button 3 times. If you don’t reset the reminder, the
“CL” indicator will flash again when you restart the unit.
Air Filter Replacement Reminder After 2,880 hours of use, the display window
on the indoor unit will flash “nF.” This is a reminder to replace your filter.
After 15 seconds, the unit will revert to its previous display.
To reset the reminder, press the LED button on your remote control 4 times, or
press the MANUAL CONTROL button 3 times. If you don’t reset the reminder, the
“nF” indicator will flash again when you restart the unit.
CAUTION
Any maintenance and cleaning of outdoor unit should be performed by an
authorized dealer or a licensed service provider.
Any unit repairs should be performed by an authorized dealer or a licensed
service provider.
Maintenance –
Long Periods of Non-Use
If you plan not to use your air conditioner for an extended period of time, do
the following:
Maintenance –
Pre-Season Inspection
After long periods of non-use, or before periods of frequent use, do the
following:
Troubleshooting
SAFETY PRECAUTIONS
If ANY of the following conditions occurs, turn off your unit immediately!
- The power cord is damaged or abnormally warm
- You smell a burning odor
- The unit emits loud or abnormal sounds
- A power fuse blows or the circuit breaker frequently trips
- Water or other objects fall into or out of the unit
DO NOT ATTEMPT TO FIX THESE YOURSELF! CONTACT AN AUTHORIZED SERVICE
PROVIDER IMMEDIATELY!
Common Issues
The following problems are not a malfunction and in most situations will not
require repairs.
Issue | Possible Causes |
---|
Unit does not turn on when pressing
ON/OFF button| The Unit has a 3-minute protection feature that prevents the
unit from overloading. The unit cannot be restarted within three minutes of
being turned off.
The unit changes from COOL/HEAT mode to FAN mode| The unit may change its
setting to prevent frost from forming on the unit. Once the temperature
increases, the unit will start operating in the previously selected mode
again.
The set temperature has been reached, at which point the unit turns off the
compressor. The unit will continue operating when the temperature fluctuates
again.
The indoor unit emits white mist| In humid regions, a large temperature
difference between the room’s air and the conditioned air can cause white
mist.
Both the indoor and outdoor units emit
white mist| When the unit restarts in HEAT mode after defrosting, white mist
may be emitted due to moisture generated from the defrosting process.
The indoor unit makes noises| A rushing air sound may occur when the louver
resets its position.
A squeaking sound may occur after running the unit in HEAT mode due to
expansion and contraction of the unit’s plastic parts.
Both the indoor unit and outdoor unit make noises| Low hissing sound during
operation: This is normal and is caused by refrigerant gas flowing through
both indoor and outdoor units.
Low hissing sound when the system starts, has just stopped running, or is
defrosting: This noise is normal and is caused by the refrigerant gas stopping
or changing direction.
Squeaking sound: Normal expansion and contraction of plastic and metal parts
caused by temperature changes during operation can cause squeaking noises.
The outdoor unit makes noises| The unit will make different sounds based on
its current operating mode.
Dust is emitted from either the indoor or
outdoor unit| The unit may accumulate dust during extended periods of non-use,
which will be emitted when the unit is turned on. This can be mitigated by
covering the unit during long periods of inactivity.
The unit emits a bad odor| The unit may absorb odors from the environment
(such as furniture, cooking, cigarettes, etc.) which will be emitted during
operations.
The unit’s filters have become moldy and should be cleaned.
The fan of the outdoor unit does not operate| During operation, the fan speed
is controlled to optimize product operation.
Operation is erratic, unpredictable, or
unit is unresponsive| Interference from cell phone towers and remote boosters
may cause the unit to malfunction.
In this case, try the following: responsive Disconnect the power, then
reconnect.
Press ON/OFF button on remote control to restart operation.
NOTE: If problem persists, contact a local dealer or your nearest
customer service center. Provide them with a detailed description of the unit
malfunction as well as your model number.
Troubleshooting
When troubles occur, please check the following points before contacting a
repair company.
Problem | Possible Causes | Solution |
---|---|---|
Poor Cooling Performance | Temperature setting may be higher than ambient room | |
temperature | Lower the temperature setting | |
The heat exchanger on the indoor or outdoor unit is dirty | Clean the affected |
heat exchanger
The air filter is dirty| Remove the filter and clean it according to
instructions
The air inlet or outlet of either unit is blocked| Turn the unit off, remove
the obstruction and turn it back on
Doors and windows are open| Make sure that all doors and windows are closed
while operating the unit
Excessive heat is generated by sunlight| Close windows and curtains during
periods of high heat or bright sunshine
Too many sources of heat in the room (people, computers, electronics, etc.)|
Reduce amount of heat sources
Low refrigerant due to leak or long-term use| Check for leaks, re-seal if
necessary and top off refrigerant
SILENCE function is activated (optional function)| SILENCE function can lower
product performance by reducing operating frequency. Turn off SILENCE
function.
The unit is not working| Power failure| Wait for the power to be restored
The power is turned off| Turn on the power
The fuse is burned out| Replace the fuse
Remote control batteries are dead| Replace batteries
The Unit’s 3-minute protection has been activated| Wait three minutes after
restarting the unit
Timer is activated| Turn timer off
The unit starts and
stops frequently| There’s too much or too little refrigerant in the system|
Check for leaks and recharge the system with refrigerant.
Incompressible gas or moisture has entered the system.| Evacuate and recharge
the system with refrigerant
The compressor is broken| Replace the compressor
The voltage is too high or too low| Install a ministate to regulate the
voltage
Poor heating performance| The outdoor temperature is extremely low| Use
auxiliary heating device
Cold air is entering through doors and windows| Make sure that all doors and
windows are closed during use
Low refrigerant due to leak or long-term use| Check for leaks, re-seal if
necessary and top off refrigerant
Indicator lamps continue flashing| The unit may stop operation or continue to
run safely. If the indicator lamps continue to flash or error codes appear,
wait for about 10 minutes. The problem may resolve itself.
If not, disconnect the power, then connect it again. Turn the unit on.
If the problem persists, disconnect the power and contact your nearest
customer service center.
Error code appears and
begins with the letters as the following in the window display of indoor unit:
E(x), P(x), F(x) EH(xx), EL(xx), EC(xx) PH(xx), PL(xx), PC(xx)
NOTE: If your problem persists after performing the checks and diagnostics above, turn off your unit immediately and contact an authorized service center.
Accessories
The air conditioning system comes with the following accessories. Use all of the installation parts and accessories to install the air conditioner. Improper installation may result in water leakage, electrical shock and fire, or cause the equipment to fail. The items are not included with the air conditioner must be purchased separately.
Name of Accessories| Qty(pc)| Shape| Name of Accessories|
Q’ty(pc)| Shape
---|---|---|---|---|---
Manual| 2-3| | Remote controller| 1|
Drain joint (for cooling & heating models)| 1| | Battery| 2|
Seal (for cooling & heating models)| 1| | Remote controller holder(optional)|
1|
Mounting plate| 1| | Fixing screw for remote controller holder(optional)| 2|
Anchor| 5-8 (depending on models)| | Small Filter
(Need to be installed on the back of main air filter by the authorized
technician while installing the machine)| 1-2 (depending on models)|
Mounting plate fixing screw| 5-8 (depending on models)|
Name| Shape| Quantity(PC)
---|---|---
Connecting pipe assembly| Liquid side| Φ 6.35( 1/4 in)
Φ 9.52( 3/8in)| P arts you must purchase separately. Consult the dealer about
the proper pipe size of
the unit you purchased.
Gas side| Φ 9.52( 3/8in)
Φ 12.7(1/2in)
Φ 16( 5/8in)
Φ 19( 3/4in)
Magnetic ring and belt (if supplied ,please refer to the wiring diagram to
install it on the connective cable. )| | Varies by model
Installation Summary – Indoor Unit
Unit Parts
NOTE: The installation must be performed in accordance with the requirement of local and national standards. The installation may be slightly different in different areas.
1 Wall Mounting Plate
2 Front Panel
3 Power Cable (Some Units)
4 Louver| 5 Functional Filter (On Back of Main Filter – Some Units)
6 Signal Cable
7Drainage Pipe
8 Refrigerant Piping| 9 Remote Controller
10 Remote controller Holder (Some Units)
11 Outdoor Unit Power Cable (Some Units)
---|---|---
NOTE ON ILLUSTRATIONS
Illustrations in this manual are for explanatory purposes. The actual shape of
your indoor unit may be slightly different. The actual shape shall prevail.
Indoor Unit Installation
Installation Instructions – Indoor unit
PRIOR TO INSTALLATION
Before installing the indoor unit, refer to the label on the product box to
make sure that the model number of the indoor unit matches the model number of
the outdoor unit.
Step 1: Select installation location
Before installing the indoor unit, you must choose an appropriate location.
The following are standards that will help you choose an appropriate location
for the unit.
Proper installation locations meet the following standards:
Good air circulation
Convenient drainage
Noise from the unit will not disturb other people
Firm and solid—the location will not vibrate
Strong enough to support the weight of the unit
A location at least one meter from all other electrical devices (e.g., TV,
radio, computer)
DO NOT install unit in the following locations:
Near any source of heat, steam, or combustible gas
Near flammable items such as curtains or clothing
Near any obstacle that might block air circulation
Near the doorway
In a location subject to direct sunlight
NOTE ABOUT WALL HOLE:
If there is no fixed refrigerant piping:
While choosing a location, be aware that you should leave ample room for a
wall hole (see Drill wall hole for connective piping step)
for the signal cable and refrigerant piping that connect the indoor and
outdoor units.
The default position for all piping is the right side of the indoor unit
(while facing the unit). However, the unit can accommodate piping to both the
left and right.
Refer to the following diagram to ensure proper distance from walls and ceiling:
Step 2: Attach mounting plate to wall
The mounting plate is the device on which you will mount the indoor unit.
- Remove the screw that attaches the mounting plate to the back of the indoor unit.
- Secure the mounting plate to the wall with the screws provided. Make sure that mounting plate is flat against the wall.
NOTE FOR CONCRETE OR BRICK WALLS:
If the wall is made of brick, concrete, or similar material, drill 5mm-
diameter (0.2in-diameter) holes in the wall and insert the sleeve anchors
provided. Then secure the mounting plate to the wall by tightening the screws
directly into the clip anchors.
Step 3: Drill wall hole for connective piping
- Determine the location of the wall hole based on the position of the mounting plate. Refer to Mounting Plate Dimensions.
- Using a 65mm (2.5in) or 90mm(3.54in) (depending on models )core drill, drill a hole in the wall. Make sure that the hole is drilled at a slight downward angle, so that the outdoor end of the hole is lower than the indoor end by about 5mm to 7mm (0.2-0.275in). This will ensure proper water drainage.
- Place the protective wall cuff in the hole. This protects the edges of the hole and will help seal it when you finish the installation process.
CAUTION
When drilling the wall hole, make sure to avoid wires, plumbing, and other
sensitive components.
MOUNTING PLATE DIMENSIONS
Different models have different mounting plates.
For the different customization requirements, the shape of the mounting plate
and the dimensions of the indoor unit may be slightly different. See Type A
and Type B for example:
NOTE: When the gas side connective pipe is Φ16mm(5/8in) or more, the wall hole should be 90mm(3.54in).
Step 4: Prepare refrigerant piping
The refrigerant piping is inside an insulating sleeve attached to the back of
the unit. You must prepare the piping before passing it through the hole in
the wall.
-
Based on the position of the wall hole relative to the mounting plate, choose the side from which the piping will exit the unit.
-
If the wall hole is behind the unit, keep the knock-out panel in place. If the wall hole is to the side of the indoor unit, remove the plastic knock-out panel from that side of the unit.
This will create a slot through which your piping can exit the unit. Use needle nose pliers if the plastic panel is too difficult to remove by hand. -
If existing connective piping is already embedded in the wall, proceed directly to the Connect Drain Hose step. If there is no embedded piping, connect the indoor unit’s refrigerant piping to the connective piping that will join the indoor and outdoor units.
Refer to the Refrigerant Piping Connection section of this manual for detailed instructions.
NOTE ON PIPING ANGLE
Refrigerant piping can exit the indoor unit from four different angles: Left-
hand side, Right-hand side, Left rear, Right rear.
CAUTION
Be extremely careful not to dent or damage the piping while bending them away
from the unit. Any dents in the piping will affect the unit’s performance.
Step 5: Connect drain hose
By default, the drain hose is attached to the left hand side of unit (when
you’re facing the back of the unit).
However, it can also be attached to the right-hand side.
To ensure proper drainage, attach the drain hose on the same side that your
refrigerant piping exits the unit. Attach drain hose extension (purchased
separately) to the end of drain hose.
- Wrap the connection point firmly with Teflon tape to ensure a good seal and to prevent leaks.
- For the portion of the drain hose that will remain indoors, wrap it with foam pipe insulation to prevent condensation.
- Remove the air filter and pour a small amount of water into the drain pan to make sure that water flows from the unit smoothly.
NOTE ON DRAIN HOSE PLACEMENT
Make sure to arrange the drain hose according to the following figures.
Make sure there are no kinks or dent in drain hose to ensure proper drainage.
Kinks in the drain hose will create water traps.
Kinks in the drain hose will create water traps.
Do not place the end of the drain hose in water or in containers that collect
water.
This will prevent proper drainage.
PLUG THE UNUSED DRAIN HOLE
To prevent unwanted leaks you must plug the unused drain hole with the rubber plug provided.
BEFORE PERFORMING ANY ELECTRICAL WORK, READ THESE REGULATIONS
- All wiring must comply with local and national electrical codes, regulations and must be installed by a licensed electrician.
- All electrical connections must be made according to the Electrical Connection Diagram located on the panels of the indoor and outdoor units.
- If there is a serious safety issue with the power supply, stop work immediately. Explain your reasoning to the client, and refuse to install the unit until the safety issue is properly resolved.
- Power voltage should be within 90-110% of rated voltage. Insufficient power supply can cause malfunction, electrical shock, or fire.
- If connecting power to fixed wiring, a surge protector and main power switch should be installed.
- If connecting power to fixed wiring, a switch or circuit breaker that disconnects all poles and has a contact separation of at least 1/8in (3mm) must be incorporated in the fixed wiring. The qualified technician must use an approved circuit breaker or switch.
- Only connect the unit to an individual branch circuit outlet. Do not connect another appliance to that outlet.
- Make sure to properly ground the air conditioner.
- Every wire must be firmly connected. Loose wiring can cause the terminal to overheat, resulting in product malfunction and possible fire.
- Do not let wires touch or rest against refrigerant tubing, the compressor, or any moving parts within the unit.
- If the unit has an auxiliary electric heater, it must be installed at least 1 meter (40in) away from any combustible materials.
- To avoid getting an electric shock, never touch the electrical components soon after the power supply has been turned off. After turning off the power, always wait 10 minutes or more before you touch the electrical components.
WARNING
BEFORE PERFORMING ANY ELECTRICAL OR WIRING WORK, TURN OFF THE MAIN
POWER TO THE SYSTEM.
Step 6: Connect signal and power cables
The signal cable enables communication between the indoor and outdoor units.
You must first choose the right cable size before preparing it for connection.
Cable Types
- Indoor Power Cable (if applicable): H05VV-F or H05V2V2-F
- Outdoor Power Cable: H07RN-F or H05RN-F
- Signal Cable: H07RN-F
NOTE: In North America, choose the cable type according to the local electrical codes and regulations.
Minimum Cross-Sectional Area of Power and Signal Cables (For reference) (Not applicable for North America)
Rated Current of Appliance (A) | Nominal Cross-Sectional Area (mm²) |
---|---|
> 3 and ≤6 | 0.75 |
> 6 and ≤10 | 1 |
> 10 and ≤16 | 1.5 |
> 16 and ≤25 | 2.5 |
> 25 and≤ 32 | 4 |
> 32 and ≤40 | 6 |
CHOOSE THE RIGHT CABLE SIZE
The size of the power supply cable, signal cable, fuse, and switch needed is
determined by the maximum current of the unit. The maximum current is
indicated on the nameplate located on the side panel of the unit.
NOTE: In North America, please choose the right cable size according to
the Minimum Circuit Ampacity indicated on the nameplate of the unit.
WARNING
ALL WIRING MUST BE PERFORMED STRICTLY IN ACCORDANCE WITH THE WIRING
DIAGRAM LOCATED ON THE BACK OF THE INDOOR UNIT’ S FRONT PANEL .
-
Open front panel of the indoor unit.
-
Using a screwdriver, open the wire box cover on the right side of the unit. This will reveal the terminal block.
NOTE:
• For the units with conduit tube to connect the cable, remove the big plastic konck-out panel to create a slot through which the conduit tube can be installed.
• For the units with five-core cable, remove the middle small plactic knock- out panel to create a slot through which the cable can exit.
• Use needle nose pliers if the plastic panel is too difficult to remove by hand. -
Unscrew the cable clamp below the terminal block and place it to the side.
-
Facing the back of the unit, remove the plastic panel on the bottom left-hand side.
-
Feed the signal wire through this slot, from the back of the unit to the front.
-
Facing the front of the unit, connect the wire according to the indoor unit’s wiring diagram, connect the u-lug and firmly screw each wire to its corresponding terminal.
CAUTION
DO NOT MIX UP LIVE AND NULL WIRES
This is dangerous, and can cause the air conditioning unit to malfunction. -
After checking to make sure every connection is secure, use the cable clamp to fasten the signal cable to the unit. Screw the cable clamp down tightly.
-
Replace the wire cover on the front of the unit, and the plastic panel on the back.
NOTE ABOUT WIRING
THE WIRING CONNECTION PROCESS MAY DIFFER SLIGHTLY BETWEEN UNITS AND
REGIONS.
Step 7: Wrappiping and cables
Before passing the piping, drain hose, and the signal cable through the wall
hole, you must bundle them together to save space, protect them, and insulate
them(Not applicable in North America).
-
Bundle the drain hose, refrigerant pipes, and signal cable as shown below:
DRAIN HOSE MUST BE ON BOTTOM
Make sure that the drain hose is at the bottom of the bundle. Putting the drain hose at the top of the bundle can cause the drain pan to overflow, which can lead to fire or water damage.
DO NOT INTERTWINE SIGNAL CABLE WITH OTHER WIRES
While bundling these items together, do not intertwine or cross the signal cable with any other wiring. -
Using adhesive vinyl tape, attach the drain hose to the underside of the refrigerant pipes.
-
Using insulation tape, wrap the signal wire, refrigerant pipes, and drain hose tightly together. Double-check that all items are bundled.
DO NOT WRAP ENDS OF PIPING
When wrapping the bundle, keep the ends of the piping unwrapped. You need to
access them to test for leaks at the end of the installation process (refer to
Electrical Checks and Leak Checks section of this manual).
Step 8: Mount indoor unit
If you installed new connective piping to the outdoor unit, do the following:
- If you have already passed the refrigerant piping through the hole in the wall, proceed to Step 4.
- Otherwise, double-check that the ends of the refrigerant pipes are sealed to prevent dirt or foreign materials from entering the pipes.
- Slowly pass the wrapped bundle of refrigerant pipes, drain hose, and signal wire through the hole in the wall.
- Hook the top of the indoor unit on the upper hook of the mounting plate.
- Check that unit is hooked firmly on mounting by applying slight pressure to the left and right-hand sides of the unit. The unit should not jiggle or shift.
- Using even pressure, push down on the bottom half of the unit. Keep pushing down until the unit snaps onto the hooks along the bottom of the mounting plate.
- Again, check that the unit is firmly mounted by applying slight pressure to the left and the right-hand sides of the unit.
If refrigerant piping is already embedded in the wall, do the following:
-
Hook the top of the indoor unit on the upper hook of the mounting plate.
-
Use a bracket or wedge to prop up the unit, giving you enough room to connect the refrigerant piping, signal cable, and drain hose.
-
Connect drain hose and refrigerant piping (refer to Refrigerant Piping Connection section of this manual for instructions).
-
Keep pipe connection point exposed to perform the leak test (refer to Electrical Checks and Leak Checks section of this manual).
-
After the leak test, wrap the connection point with insulation tape.
-
Remove the bracket or wedge that is propping up the unit.
-
Using even pressure, push down on the bottom half of the unit. Keep pushing down until the unit snaps onto the hooks along the bottom of the mounting plate.
UNIT IS ADJUSTABLE
Keep in mind that the hooks on the mounting plate are smaller than the holes
on the back of the unit. If you find that you don’t have ample room to connect
embedded pipes to the indoor unit, the unit can be adjusted left or right by
about 30-50mm (1.18-1.96in), depending on the model.
Outdoor Unit Installation
Install the unit by following local codes and regulations , there may be differ slightly between different regions.
Installation Instructions – Outdoor unit
Step 1: Select installation location
Before installing the outdoor unit, you must choose an appropriate location.
The following are standards that will help you choose an appropriate location
for the unit.
Proper installation locations meet the following standards:
Meets all spatial requirements shown in Installation Space Requirements above.
Good air circulation and ventilation
Firm and solid—the location can support the unit and will not vibrate
Noise from the unit will not disturb others
Protected from prolonged periods of direct sunlight or rain
Where snowfall is anticipated, take appropriate measures to prevent ice
buildup and coil damage.
DO NOT install unit in the following locations:
Near an obstacle that will block air inlets and outlets
Near a public street, crowded areas, or where noise from the unit will disturb
others
Near animals or plants that will be harmed by hot air discharge
Near any source of combustible gas
In a location that is exposed to large amounts of dust
In a location exposed to a excessive amounts of salty air
SPECIAL CONSIDERATIONS FOR EXTREME WEATHER
If the unit is exposed to heavy wind:
Install unit so that air outlet fan is at a 90° angle to the direction of the
wind. If needed, build a barrier in front of the unit to protect it from
extremely heavy winds. See Figures below.
If the unit is frequently exposed to heavy rain or snow:
Build a shelter above the unit to protect it from the rain or snow. Be careful
not to obstruct air flow around the unit.
If the unit is frequently exposed to salty air (seaside):
Use outdoor unit that is specially designed to resist corrosion.
Step 2: Install drain joint(Heat pump unit only)
Before bolting the outdoor unit in place, you must install the drain joint at
the bottom of the unit. Note that there are two different types of drain
joints depending on the type of outdoor unit.
If the drain joint comes with a rubber seal (see Fig. A ), do the following:
- Fit the rubber seal on the end of the drain joint that will connect to the outdoor unit.
- Insert the drain joint into the hole in the base pan of the unit.
- Rotate the drain joint 90° until it clicks in place facing the front of the unit.
- Connect a drain hose extension (not included) to the drain joint to redirect water from the unit during heating mode.
If the drain joint doesn’t come with a rubber seal (see Fig. B ), do the following:
- Insert the drain joint into the hole in the base pan of the unit. The drain joint will click in place.
- Connect a drain hose extension (not included) to the drain joint to redirect water from the unit during heating mode.
IN COLD CLIMATES
In cold climates, make sure that the drain hose is as vertical as possible to
ensure swift water drainage. If water drains too slowly, it can freeze in the
hose and flood the unit.
Step 3: Anchor outdoor unit
The outdoor unit can be anchored to the ground or to a wall-mounted bracket
with bolt(M10). Prepare the installation base of the unit according to the
dimensions below.
UNIT MOUNTING DIMENSIONS
The following is a list of different outdoor unit sizes and the distance
between their mounting feet. Prepare the installation base of the unit
according to the dimensions below.
Outdoor Unit Dimensions (mm)
W x H x D| Mounting Dimensions
---|---
Distance A (mm)| Distance B (mm)
681x434x285 (26.8”x17.1”x11.2”)| 460 (18.1”)| 292 (11.5”)
700x550x270 (27.5”x21.6”x10.6”)| 450 (17.7”)| 260 (10.2”)
700x550x275 (27.5”x21.6”x10.8”)| 450 (17.7”)| 260 (10.2”)
720x495x270 (28.3”x19.5”x10.6”)| 452 (17.8”)| 255 (10.0”)
728x555x300 (28.7”x21.8”x11.8”)| 452 (17.8”)| 302(11.9”)
765x555x303 (30.1”x21.8”x11.9”)| 452 (17.8”)| 286(11.3”)
770x555x300 (30.3”x21.8”x11.8”)| 487 (19.2”)| 298 (11.7”)
805x554x330 (31.7”x21.8”x12.9”)| 511 (20.1”)| 317 (12.5”)
800x554x333 (31.5”x21.8”x13.1”)| 514 (20.2”)| 340 (13.4”)
845x702x363 (33.3”x27.6”x14.3”)| 540 (21.3”)| 350 (13.8”)
890x673x342 (35.0”x26.5”x13.5”)| 663 (26.1”)| 354 (13.9”)
946x810x420 (37.2”x31.9”x16.5”)| 673 (26.5”)| 403 (15.9”)
946x810x410 (37.2”x31.9”x16.1”)| 673 (26.5”)| 403 (15.9”)
If you will install the unit on the ground or on a concrete mounting platform, do the following:
- Mark the positions for four expansion bolts based on dimensions chart.
- Pre-drill holes for expansion bolts.
- Place a nut on the end of each expansion bolt.
- Hammer expansion bolts into the pre-drilled holes.
- Remove the nuts from expansion bolts, and place outdoor unit on bolts.
- Put washer on each expansion bolt, then replace the nuts.
- Using a wrench, tighten each nut until snug.
WARNING
WHEN DRILLING INTO CONCRETE, EYE PROTECTION IS RECOMMENDED AT ALL
TIMES.
If you will install the unit on a wall-mounted bracket , do the following:
CAUTION
Make sure that the wall is made of solid brick, concrete, or of similarly
strong material. The wall must be able to support at least four times the
weight of the unit.
- Mark the position of bracket holes based on dimensions chart.
- Pre-drill the holes for the expansion bolts.
- Place a washer and nut on the end of each expansion bolt.
- Thread expansion bolts through holes in mounting brackets, put mounting brackets in position, and hammer expansion bolts into the wall.
- Check that the mounting brackets are level.
- Carefully lift unit and place its mounting feet on brackets.
- Bolt the unit firmly to the brackets.
- If allowed, install the unit with rubber gaskets to reduce vibrations and noise.
Step 4: Connect signal and power cables
The outside unit’s terminal block is protected by an electrical wiring cover
on the side of the unit. A comprehensive wiring diagram is printed on the
inside of the wiring cover.
WARNING
BEFORE PERFORMING ANY ELECTRICAL OR WIRING WORK, TURN OFF THE MAIN POWER TO
THE SYSTEM.
-
Prepare the cable for connection:
USE THE RIGHT CABLE
Please choose the right cable refer to “ Cable types” in page 22.
CHOOSE THE RIGHT CABLE SIZE
The size of the power supply cable, signal cable, fuse, and switch needed is determined by the maximum current of the unit. The maximum current is indicated on the nameplate located on the side panel of the unit.
NOTE: In North America, please choose the right cable size according to the Minimum Circuit Ampacity indicated on the nameplate of the unit.
a. Using wire strippers, strip the rubber jacket from both ends of cable to reveal about 40mm (1.57in) of the wires inside.
b. Strip the insulation from the ends of the wires.
c. Using a wire crimper, crimp u-lugs on the ends of the wires.
PAY ATTENTION TO LIVE WIRE
While crimping wires, make sure you clearly distinguish the Live (“L”) Wire from other wires.
WARNING
ALL WIRING WORK MUST BE PERFORMED STRICTLY IN ACCORDANCE WITH THE WIRING DIAGRAM LOCATED INSIDE OF WIRE COVER OF THE OUTDOOR UNIT . -
Unscrew the electrical wiring cover and remove it.
-
Unscrew the cable clamp below the terminal block and place it to the side.
-
Connect the wire according to the wiring diagram, and firmly screw the u-lug of each wire to its corresponding terminal.
-
After checking to make sure every connection is secure, loop the wires around to prevent rain water from flowing into the terminal.
-
Using the cable clamp, fasten the cable to the unit. Screw the cable clamp down tightly.
-
Insulate unused wires with PVC electrical tape.
Arrange them so that they do not touch any electrical or metal parts. -
Replace the wire cover on the side of the unit, and screw it in place.
NOTE: If the cable clamp looks like the following, please select the appropriate through-hole according to the diameter of the wire.
In North America
- Remove the wire cover from the unit by loosening the 3 screws.
- Dismount caps on the conduit panel.
- Temporarily mount the conduit tubes(not included) on the conduit panel.
- Properly connect both the power supply and low voltage lines to the corresponding terminals on the terminal block.
- Ground the unit in accordance with local codes.
- Be sure to size each wire allowing several inches longer than the required length for wiring.
- Use lock nuts to secure the conduit tubes.
Refrigerant Piping Connection
When connecting refrigerant piping, do not let substances or gases other than
the specified refrigerant enter the unit. The presence of other gases or
substances will lower the unit’s capacity, and can cause abnormally high
pressure in the refrigeration cycle. This can cause explosion and injury.
Note on Pipe Length
The length of refrigerant piping will affect the performance and energy
efficiency of the unit. Nominal efficiency is tested on units with a pipe length
of 5 meters (16.5ft)( In North America, the standard pipe length is 7.5m
(25’)). A minimum pipe run of 3 metres is required to minimise vibration &
excessive noise.
In special tropical area, for the R290 refrigerant models, no refrigerant can
be added and the maximum length of refrigerant pipe should not exceed 10
meters(32.8ft).
Refer to the table below for specifications on the maximum length and drop
height of piping.
Maximum Length and Drop Height of Refrigerant Piping per Unit Model
Model| Capacity (BTU/h)| Max. Length (m)| Max. Drop Height
(m)
---|---|---|---
R410A,R32 Inverter
Split Air Conditioner| < 15,000| 25 (82ft)| 10 (33ft)
15,000 and < 24,000| 30 (98.5ft)| 20 (66ft)
24,000 and < 36,000| 50 (164ft)| 25 (82ft)
R22 Fixed-speed
Split Air Conditioner| < 18,000| 10 (33ft)| 5 (16ft)
18,000 and < 21,000| 15 (49ft)| 8(26ft)
21,000 and < 35,000| 20 (66ft)| 10(33ft)
R410A, R32 Fixed-speed
Split Air Conditioner| < 18,000| 20 (66ft)| 8(26ft)
18,000 and < 36,000| 25 (82ft)| 10(33ft)
Connection Instructions – Refrigerant Piping
Step 1: Cut pipes
When preparing refrigerant pipes, take extra care to cut and flare them
properly. This will ensure efficient operation and minimize the need for future
maintenance.
- Measure the distance between the indoor and outdoor units.
- Using a pipe cutter, cut the pipe a little longer than the measured distance.
- Make sure that the pipe is cut at a perfect 90° angle.
DO NOT DEFORM PIPE WHILE CUTTING
Be extra careful not to damage, dent, or deform the pipe while cutting. This
will drastically reduce the heating efficiency of the unit.
Step 2: Remove burrs
Burrs can affect the air-tight seal of refrigerant piping connection. They
must be completely removed.
- Hold the pipe at a downward angle to prevent burrs from falling into the pipe.
- Using a reamer or deburring tool, remove all burrs from the cut section of the pipe.
Step 3: Flare pipe ends
Proper flaring is essential to achieve an airtight seal.
-
After removing burrs from cut pipe, seal the ends with PVC tape to prevent foreign materials from entering the pipe.
-
Sheath the pipe with insulating material.
-
Place flare nuts on both ends of pipe. Make sure they are facing in the right direction, because you can’t put them on or change their direction after flaring.
-
Remove PVC tape from ends of pipe when ready to perform flaring work.
-
Clamp flare form on the end of the pipe.
The end of the pipe must extend beyond the edge of the flare form in accordance with the dimensions shown in the table below. PIPING EXTENSION BEYOND FLARE FORM Outer Diameter of Pipe (mm)| Min.| Max.
---|---|---
Ø 6.35 (Ø 0.25”)| 0.7 (0.0275”)| 1.3 (0.05”)
Ø 9.52 (Ø 0.375”)| 1.0 (0.04”)| 1.6 (0.063”)
Ø12.7 ( Ø 0.5”)| 1.0 (0.04”)| 1.8 (0.07”)
Ø 16 ( Ø 0.63”)| 2.0 (0.078”)| 2.2 (0.086”)
Ø 19 ( Ø 0.75”)| 2.0 (0.078”)| 2.4 (0.094”) -
Place flaring tool onto the form.
-
Turn the handle of the flaring tool clockwise until the pipe is fully flared.
-
Remove the flaring tool and flare form, then inspect the end of the pipe for cracks and even flaring.
Step 4: Connect pipes
When connecting refrigerant pipes, be careful not to use excessive torque or
to deform the piping in any way. You should first connect the low-pressure
pipe, then the high-pressure pipe.
MINIMUM BEND RADIUS
When bending connective refrigerant piping, the minimum bending radius is
10cm.
Instructions for Connecting Piping to Indoor Unit
- Align the center of the two pipes that you will connect.
- Tighten the flare nut as tightly as possible by hand.
- Using a spanner, grip the nut on the unit tubing.
- While firmly gripping the nut on the unit tubing, use a torque wrench to tighten the flare nut according to the torque values in the Torque Requirements table below. Loosen the flaring nut slightly, then tighten again.
TORQUE REQUIREMENTS
Outer Diameter of Pipe (mm)| Tightening Torque| Flare
dimension(B) (mm)| Flare shape
---|---|---|---
Ø 6.35 (Ø 0.25”)| 18~20(180~200kgf.cm)| 8.4~8.7 (0.33~0.34”)|
Ø 9.52 (Ø 0.375”)| 32~39(320~390kgf.cm)| 13.2~13.5 (0.52~0.53”)
Ø 12.7 (Ø 0.5”)| 49~59(490~590kgf.cm)| 16.2~16.5 (0.64~0.65”)
Ø 16 (Ø 0.63”)| 57~71(570~710kgf.cm)| 19.2~19.7 (0.76~0.78”)
Ø 19 ( Ø 0.75”)| 67~101(670~1010kgf.cm)| 23.2~23.7 (0.91~0.93”)
DO NOT USE EXCESSIVE TORQUE
Excessive force can break the nut or damage the refrigerant piping. You must
not exceed torque requirements shown in the table above.
Instructions for Connecting Piping to Outdoor Unit
- Unscrew the cover from the packed valve on the side of the outdoor unit.
- Remove protective caps from ends of valves.
- Align flared pipe end with each valve, and tighten the flare nut as tightly as possible by hand.
- Using a spanner, grip the body of the valve. Do not grip the nut that seals the service valve.
- While firmly gripping the body of the valve, use a torque wrench to tighten the flare nut according to the correct torque values.
- Loosen the flaring nut slightly, then tighten again.
- Repeat Steps 3 to 6 for the remaining pipe.
USE SPANNER TO GRIP MAIN BODY OF VALVE
Torque from tightening the flare nut can snap off other parts of valve.
Air Evacuation
Preparations and Precautions
Air and foreign matter in the refrigerant circuit can cause abnormal rises in
pressure, which can damage the air conditioner, reduce its efficiency, and
cause injury. Use a vacuum pump and manifold gauge to evacuate the refrigerant
circuit, removing any non-condensable gas and moisture from the system.
Evacuation should be performed upon initial installation and when unit is
relocated.
BEFORE PERFORMING EVACUATION
Check to make sure the connective pipes between the indoor and outdoor units
are connected properly .
Check to make sure all wiring is connected properly.
Evacuation Instructions
-
Connect the charge hose of the manifold gauge to service port on the outdoor unit’s low pressure valve.
-
Connect another charge hose from the manifold gauge to the vacuum pump.
-
Open the Low Pressure side of the manifold gauge. Keep the High Pressure side closed.
-
Turn on the vacuum pump to evacuate the system.
-
Run the vacuum for at least 15 minutes, or until the Compound Meter reads -76cmHG (-10⁵ Pa).
-
Close the Low Pressure side of the manifold gauge, and turn off the vacuum pump.
-
Wait for 5 minutes, then check that there has been no change in system pressure.
-
If there is a change in system pressure, refer to Gas Leak Check section for information on how to check for leaks. If there is no change in system pressure, unscrew the cap from the packed valve (high pressure valve).
-
Insert hexagonal wrench into the packed valve (high pressure valve) and open the valve by turning the wrench in a 1/4 counterclockwise turn. Listen for gas to exit the system, then close the valve after 5 seconds.
-
Watch the Pressure Gauge for one minute to make sure that there is no change in pressure. The Pressure Gauge should read slightly higher than atmospheric pressure.
-
Remove the charge hose from the service port.
-
Using hexagonal wrench, fully open both the high pressure and low pressure valves.
-
Tighten valve caps on all three valves (service port, high pressure, low pressure) by hand. You may tighten it further using a torque wrench if needed.
OPEN VALVE STEMS GENTLY
When opening valve stems, turn the hexagonal wrench until it hits against the
stopper. Do not try to force the valve to open further.
Note on Adding Refrigerant
Some systems require additional charging depending on pipe lengths. The
standard pipe length varies according to local regulations. For example, in
North America, the standard pipe length is 7.5m (25’). In other areas, the
standard pipe length is 5m (16‘). The refrigerant should be charged from the
service port on the outdoor unit’s low pressure valve. The additional
refrigerant to be charged can be calculated using the following formula:
ADDITIONAL REFRIGERANT PER PIPE LENGTH
Connective Pipe Length (m)| Air Purging Method|
Additional Refrigerant
---|---|---
< Standard pipe length| Vacuum Pump|
N/A
Standard pipe length| Vacuum Pump|
Liquid Side: Ø 6.35 (ø 0.25”)
R32:
(Pipe length – standard length) x 12g/m
(Pipe length – standard length) x 0.13oZ/ft
R290:
(Pipe length – standard length) x 10g/m
(Pipe length – standard length) x 0.10oZ/ft
R410A:
(Pipe length – standard length) x 15g/m
(Pipe length – standard length) x 0.16oZ/ft
R22:
(Pipe length – standard length) x 20g/m
(Pipe length – standard length) x 0.21oZ/ft
|
Liquid Side: Ø 9.52 (ø 0.375”)
R32:
(Pipe length – standard length) x 24g/m
(Pipe length – standard length) x 0.26oZ/ft
R290:
(Pipe length – standard length) x 18g/m
(Pipe length – standard length) x 0.19oZ/ft
R410A:
(Pipe length – standard length) x 30g/m
(Pipe length – standard length) x 0.32oZ/ft
R22:
(Pipe length – standard length) x 40g/m
(Pipe length – standard length) x 0.42oZ/ft
For R290 refrigerant unit, the total amount of refrigerant to be charged is no
more than:
387g(<=9000Btu/h), 447g(>9000Btu/h and <=12000Btu/h), 547g(>12000Btu/h and
<=18000Btu/h), 632g(>18000Btu/h and <=24000Btu/h).
CAUTION DO NOT mix refrigerant types.
Electrical and Gas Leak Checks
Before Test Run
Only perform test run after you have completed the following steps:
- Electrical Safety Checks – Confirm that the unit’s electrical system is safe and operating properly
- Gas Leak Checks – Check all flare nut connections and confirm that the system is not leaking
- Confirm that gas and liquid (high and low pressure) valves are fully open
Electrical Safety Checks
After installation, confirm that all electrical wiring is installed in
accordance with local and national regulations, and according to the
Installation Manual.
BEFORE TEST RUN
Check Grounding Work
Measure grounding resistance by visual detection and with grounding resistance
tester. Grounding resistance must be less than 0.1Ω.
Note: This may not be required for some locations in North America.
DURING TEST RUN
Check for Electrical Leakage
During the Test Run, use an electro probe and multimeter to perform a
comprehensive electrical leakage test.
If electrical leakage is detected, turn off the unit immediately and call a
licensed electrician to find and resolve the cause of the leakage.
Note: This may not be required for some locations in North America.
WARNING – RISK OF
ELECTRIC SHOCK
ALL WIRING MUST COMPLY WITH LOCAL AND NATIONAL ELECTRICAL CODES, AND MUST BE
INSTALLED BY A LICENSED ELECTRICIAN.
Gas Leak Checks
There are two different methods to check for gas leaks.
Soap and Water Method
Using a soft brush, apply soapy water or liquid detergent to all pipe
connection points on the indoor unit and outdoor unit. The presence of bubbles
indicates a leak.
Leak Detector Method
If using leak detector, refer to the device’s operation manual for proper
usage instructions.
AFTER PERFORMING GAS LEAK CHECKS
After confirming that the all pipe connection points DO NOT leak, replace the
valve cover on the outside unit.
A: Low pressure stop valve
B: High pressure stop valve
C& D: Indoor unit flare nuts
Test Run
Test Run Instructions
You should perform the Test Run for at least 30 minutes.
-
Connect power to the unit.
-
Press the ON/OFF button on the remote controller to turn it on.
-
Press the MODE button to scroll through the following functions, one at a time:
COOL – Select lowest possible temperature
HEAT – Select highest possible temperature -
Let each function run for 5 minutes, and perform the following checks:
List of Checks to Perform| | PASS/FAIL
---|---|---
No electrical leakage| |
Unit is properly grounded| |
All electrical terminals properly covered| |
Indoor and outdoor units are solidly installed| |
All pipe connection points do not leak| Outdoor (2):| Indoor (2):
Water drains properly from drain hose| |
All piping is properly insulated| |
Unit performs COOL function properly| |
Unit performs HEAT function properly| |
Indoor unit louvers rotate properly| |
Indoor unit responds to remote controller| |
DOUBLE-CHECK PIPE CONNECTIONS
During operation, the pressure of the refrigerant circuit will increase. This
may reveal leaks that were not present during your initial leak check. Take
time during the Test Run to double-check that all refrigerant pipe connection
points do not have leaks. Refer to Gas Leak Check section for instructions.
- After the Test Run is successfully completed, and you confirm that all checks points in List of Checks to Perform have PASSED, do the following:
a. Using remote control, return unit to normal operating temperature.
b. Using insulation tape, wrap the indoor refrigerant pipe connections that you left uncovered during the indoor unit installation process.
IF AMBIENT TEMPERATURE IS BELOW 16°C (60°F)
You can’t use the remote controller to turn on the COOL function when the
ambient temperature is below 16°C. In this instance, you can use the MANUAL
CONTROL button to test the COOL function.
- Lift the front panel of the indoor unit, and raise it until it clicks in place.
- The MANUAL CONTROL button is located on the right-hand side of the unit. Press it 2 times to select the COOL function.
- Perform Test Run as normal.
Packing and unpacking the unit
Instructions for packing and unpacking the unit:
Unpacking:
Indoor unit:
- Cut the sealing tape on the carton with a knife, one cut on the left, one cut in the middle and one cut on the right.
- Use the vice to take out the sealing nails on the top of the carton.
- Open the carton.
- Take out the middle support plate if it is included.
- Take out the accessory package, and take out the connecting wire if it is included.
- Lift the machine out of the carton and lay it flat.
- Remove the left and right package foam or the upper and lower packaging foam, untie the packaging bag.
Outdoor Unit
- Cut the packing belt.
- Take the unit out of the carton.
- Remove the foam from the unit.
- Remove the packaging bag from the unit.
Packing:
Indoor unit:
- Put the indoor unit into the packing bag.
- Attach the left and right package foam or the upper and lower packaging foam to the unit.
- Put the unit into the carton, then put accessory package in.
- Close the carton and seal it with the tape.
- Using the packing belt if necessary.
Outdoor unit:
- Put the outdoor unit into the packing bag.
- Put the bottom foam into the box.
- Put the unit into the carton, then put the upper packaging foam on the unit.
- Close the carton and seal it with the tape.
- Using the packing belt if necessary.
NOTE: Please keep all packaging items if you may need in the future.
The design and specifications are subject to change without prior notice for
product improvement. Consult with the sales agency or manufacturer for
details.
Any updates to the manual will be uploaded to the service website, please
check for the latest version.
LAMBORGHINI Caloreclima è un marchio del gruppo FERROLI Spa
37047 San Bonifacio (Verona) Italy ¬ Via Ritonda 78/A ¬ tel. +39.045.6139411 ¬
fax +39.045.6100933
www.ferroli.com
Made in China
References
- FERROLI - Caldaie, condizionatori ed energie alternative
- LAMBORGHINI CALOR - Caldaie, condizionatori ed energie alternative