Specifications

Code Model
2CP0022L DORA TECH 200 HT
2CP0023L DORA TECH 260 HT
Code Accessories
2CP00280 Cascade regulator kit (1 piece should be installed for each water

heater in cascade)

Control panel

The simple and intuitive programmable control system on board the machine allows selection of the various Operating Modes: Eco: heat pump only (Max setpoint 62°C)
/ Auto: heat pump with heating element for possible support (Max setpoint 62°C)
/ Boost: heat pump and heating element at the same time (Max setpoint 75°C) /
Electric: heating element only (Max setpoint 75°C) / Fan: active ventilation only.

The DORA TECH electronics are able to optimize the integration of energy from other sources, exploiting the possible availability of photovoltaic electricity.
The DORA TECH electronics can manage and optimize the integration of energy from other sources: activating and exploiting any overproduction of photovoltaic electricity by raising the temperature of water in the storage tank up to a value set by the user (max 75°C).

Application

The air can be ducted in order to direct the flow appropriately in different situations.
Application
Use of energy present in the environment
(BOILER ROOM OR LAUNDRY)

Heat pump water heater for floor-standing installation with positive air temperatures

  • Air heat pump and integrated storage tank for DHW production with inlet air temperature range not lower than 4°C
  • Possibility of ducting the expelled air
  • Floor-standing installation
  • Available operating modes: Eco, Auto, Boost, Electric, Fan
  • Wi-Fi card installed as standard and control via smartphone using the “LAMBORGHINI CALORECLIMA HOME” App
  • 1500 W support heating element
  • Simple and intuitive touch control panel on board machine
  • Enameled steel water storage tank with 50 mm polyurethane insulation
  •  Aluminum main heat exchanger outside the tank
  • Corrosion protection by means of magnesium anode
  • Programmable anti-legionella cycle
  • Arrangement (digital input) for activation with availability of photovoltaic energy
  • Arrangement (digital input) for activation with reduced electricity rates
  • R134a ecological gas

Connectivity

CONNECTIVITY Thanks to the “LAMBORGHINI CALORECLIMA HOME” App downloadable on smartphone, DORA TECH can be fully managed by changing its parameters and operating modes.
Connectivity

|
---|---
|

Limits of use

TEMPERATURE RANGE. The graph below indicates the temperature range of the produced air and water, which guarantees correct operation.
Limits of use

A Inlet air temperature °C
B Temperature of hot water produced °C
Working range for heat pump
Integration with heating element only

POWER SUPPLY VOLTAGE RANGE. The table below provides the admissible variation conditions for the electrical power supply

Standard power supply V-ph-Hz 230-1-50
Admissible voltage range V 207 – 254
DORA TECH 200 HT 260 HT
--- --- ---
Nominal storage capacity L 192
Max. hot water capacity at 40°C L 260
Storage dispersion W 60
DHW max. temperature with heat pump only °C 62
DHW max. temperature with supplementary electric booster °C 75
Integrated heating element power W 1500
Average absorbed power in heating W 370
Pump heat output W 1248
Dimensions (Ø x H) mm 621 x 1607
Empty weight kg 86
Max. water pressure bar 7
Max. air temperature °C 43
Min. air temperature °C 4
Nominal air flow m3/h 350
Max. available head for cold air outlet Pa 100
Duct diameter mm 160
Required room volume m3 >20
Power supply parameters V-Hz 230V – 50Hz
Protection rating IP24
Indoor sound power Lw(A) dB(A) 52
Gas type R134a
Charge quantity g 1000
Heating time 7°C in ECO mode hh:mm 07:16
COP 2,8
Internal coil for solar
Energy efficiency class for heating water in average climatic conditions
Energy efficiency of water heating in % in average climatic conditions %
116 127
Annual energy consumption in average climatic conditions kW/h 883
Declared load profile L
  • Test in accordance with EN16147-2017 with air inlet temperature at 20°C, boiler storage ambient temperature 20°C, water heating from 10°C to 55°C.

Dimensions and hydraulic connections (in mm)

Dimensions and hydraulic connections \(in mm\)

DORA TECH Ø 200 HT 260 HT
A mm 1″G 250
B mm 490
D mm 705
E mm 1″G 876,5
G mm 1142
H mm 1607
M mm 3/4″G 705
N mm 3/4″G 877
**O*** mm 1/2″G 976
P mm 1073
  • Outlet connection in plastic material