product

Product Information

The IDOLA S 3.2 HYBRID 28H is an air-water reversible hybrid heat pump for split installation. It can be combined with an external sanitary boiler for heating purposes. The heat pump uses R32 refrigerant and has a seasonal energy efficiency rating of A++ for heating and A++ for cooling. It is available in four models – 4, 6, 8, and 10.

The ERP data for space heating shows a rated heat output of 28 kW, a seasonal space heating energy efficiency of 94%, and an annual energy consumption of 27.9 kW. The sound power level is 49 dB, and the emissions of nitrogen oxides are 34 mg/kWh.

Product Usage Instructions

Before using the IDOLA S 3.2 HYBRID 28H heat pump, read the user manual carefully to understand its features and functions.

To install the heat pump, follow the instructions provided in the installation manual. The heat pump must be installed by a licensed professional to ensure its safe and proper functioning.

After installation, turn on the power supply and set the desired temperature using the control panel. The heat pump will start working to maintain the temperature in the room.

Regular maintenance of the heat pump is necessary to ensure its optimal performance. Clean the air filters regularly, at least once every three months, to prevent blockage and maintain good air quality. Check for any leaks or damage to the refrigerant lines and report any issues to a licensed professional immediately.

For further assistance with product usage or maintenance, refer to the user manual or contact customer support.

ERP DATA FOR SPACE HEATING

For low – temperature application (35°C)

Mod

| Average| Colder| Warmer
Energy efficiency class| Indoor unit sound power| Outdoor unit sound power|

Prated

| Seasonal energy efficiency|

Annual energy consumption

|

Prated

| Seasonal energy efficiency|

Annual energy consumption

|

Prated

| Seasonal energy efficiency|

Annual energy consumption

IDOLA S 3.2 HYBRID 28H 4| A+++| 39| 55| 6| 186| 2408| 5| 155| 2841| 5| 258| 1095
IDOLA S 3.2 HYBRID 28H 6| A+++| 39| 57| 7| 191| 2911| 6| 162| 3373| 6| 262| 1197
IDOLA S 3.2 HYBRID 28H 8| A+++| 39| 59| 8| 200| 3312| 7| 165| 4091| 8| 281| 1423
IDOLA S 3.2 HYBRID 28H 10| A+++| 39| 60| 9| 201| 3714| 8| 165| 4545| 8| 281| 1588
For medium-temperature application (55°C)

Mod

| Average| Colder| Warmer
Energy efficiency class| Indoor unit sound power| Outdoor unit sound power|

Prated

| Seasonal energy efficiency|

Annual energy consumption

|

Prated

| Seasonal energy efficiency|

Annual energy consumption

|

Prated

| Seasonal energy efficiency|

Annual energy consumption

IDOLA S 3.2 HYBRID 28H 4| A++| 39| 56| 4| 128| 2768| 3| 104| 3115| 5| 164| 1549
IDOLA S 3.2 HYBRID 28H 6| A++| 39| 58| 6| 136| 3381| 4| 112| 3640| 5| 165| 1601
IDOLA S 3.2 HYBRID 28H 8| A++| 39| 59| 7| 130| 4089| 6| 113| 4920| 8| 176| 2254
IDOLA S 3.2 HYBRID 28H 10| A++| 39| 60| 8| 135| 4576| 7| 118| 5491| 8| 184| 2308

GAS BOILER PRODUCT FICHE

Condensing boiler: YES

Low-temperature boiler (): YES
B1 Boiler: NO
Combination heater: NO
Cogeneration space heater: NO
Item| Symbol            Unit| Value
Seasonal space heating energy efficiency class (from
A+++ to D )|  | A
Rated heat output|
Pn                 kW| 28
Seasonal space heating energy efficiency| ηs          
%| 94
Useful heat output
Useful heat output at rated heat output and high-temperature regime (*)| P4 kW| 27,9
Useful heat output at 30% of rated heat output and low-temperature regime ()| P1                 kW| 8,1
Useful efficiency*
Useful efficiency at rated heat output and high-temperature regime (
)| η4
%| 88,1
Useful efficiency at 30% of rated heat output and low-temperature regime (
)| η1             %| 98,6
Auxiliary electricity consumption
At full load| elmax              kW| 0,032
At part load| elmin              kW| 0,013
In standby mode| PSB                kW| 0,004
Other items
Standby heat loss| Pstby               kW| 0,042
Ignition burner power consumption| Pign                kW| 0,000
Annual energy consumption| QHE                 GJ| 86
Sound power level| LWA                dB| 49
Emissions of nitrogen oxides| NOx           mg/kWh| 34

(*) High-temperature regime means 60°C return temperature at the heater inlet and 80°C feed temperature at the heater outlet.
(**) Low temperature means for condensing boilers 30°C, for low-temperature boilers 37°C and for other heaters 50°C return temperature (at heater inlet).

ERP TECHNICAL DATA SHEET FOR SPACE HEATING

IDOLA S 3.2 HYBRID 28H 4 – Bassa temperature (35°C) / Heating mode – Average climate – Low temperature (35°C)

The technical data sheet for hybrid heat pump

Model(s):| IDOLA S 3.2 HYBRID 28H 4
Hear source (air, water, brine, direct expansion)| air
Heat sink (water, brine)| water
Tipo di combustibile fossile (liquido / gas)| gas
Low temperature heat pump:| no
Heat pump combination heater:| no
Parameters are declared for low-temperature application (35°C).
Parameters are declared for average climate conditions.
Item| Symbol| Value| Unit|  | Item| Symbol| Value| Unit
Rated heat output (3)

at Tdesignh = -10°C

| Prated

= Pdesi- gnh

| ****

5,52

| ****

kW

| ****

Seasonal space heating energy efficiency

| ****

ηs

| ****

186

| ****

%

Annual energy consumption| QHE| 2408| kWh| Emissions of nitrogen oxides| NOx| –| mg/kWh
Declared capacity for heating| Declared coefficient of performance for heating
Tj = – 7 °C| Pdh| 4,88| kW| Tj = – 7 °C| COPd| 3,19| –
Tj = + 2 °C| Pdh| 3,06| kW| Tj = + 2 °C| COPd| 4,78| –
Tj = + 7 °C| Pdh| 1,93| kW| Tj = + 7 °C| COPd| 6,13| –
Tj =+12°C| Pdh| 1,48| kW| Tj =+12°C| COPd| 7,50| –
T j = THP,off| Pdh| 4,48| kW| T j = THP,off| COPd| 3,54| –
T j = Tfb,off| Pdh| 4,48| kW| T j = Tfb,off| COPd| 3,54| –
For air-to-water heat pumps: Tj = – 15 °C (if TOL < – 20 °C)| Pdh| –| kW| For air-to-water HP : Operation limit temperature (maximum

-7°C)

| COPd| –| –
Switch temperature heat pump off| Thp,off| -7| °C| Switch temperature boiler off| Tfb,off| -7| °C
Degradation coefficient (4)| Cdh| 0,90| —|
Heat pump: power input in modes other than active|  | Boiler
Off mode| POFF| 0,014| kW| Useful heat output at rated heat output and high temperature regime (3)| P4| 27,9| kW


Thermostat-off mode

| PTO| ****

0,024

| ****

kW

| Useful heat output at 30% of rated heat output and high tempera- ture regime (3)| P1| ****

8,1

| ****

kW


Standby mode

| PSB| ****

0,014

| ****

kW

| Useful efficiency at rated heat output and high temperature

regime (3)

| h4| ****

88,06

| ****

%


Crankcase heater mode

| PCK| ****

0

| ****

kW

| Useful efficiency at 30% of rated heat output and high tempera- ture regime (3)| h1| ****

98,64

| ****

%

Other items| Power input of electrical auxiliaries at full load| elmax| 0,032| kW
Capacity control of heat pump| fisso/varia- bile| Variable| Power input of electrical auxiliaries at part load| elmin| 0,013| kW
For air-to-water HP: Rated air flow

rate

| Qairsource| 2770| m3/h| Power input of electrical auxiliaries in stand-by mode| PSB| 0,004| kW
Sound power level, indoors| LWA| 39| dB(A)| Stand-by losses| Pstby| 0,042| kW
Sound power level, outdoors| LWA| 55| dB(A)| Power input of ignition burner fossil fuel| Pign| 0,000| kW
Contact details| Ferroli s.p.a. via Ritonda 78A – S.Bonifacio (VR) – Italy

Technical data sheet for hybrid heat pump

Model(s):| IDOLA S 3.2 HYBRID 28H 4
Hear source (air, water, brine, direct expansion)| air
Heat sink (water, brine)| water
Tipo di combustibile fossile (liquido / gas)| gas
Low temperature heat pump:| no
Heat pump combination heater:| no
Parameters are declared for low-temperature application (35°C).
Parameters are declared for colder climate conditions.
Item| Symbol| Value| Unit|  | Item| Symbol| Value| Unit
Rated heat output (3)

at Tdesignh = -22°C

| Prated

= Pdesi- gnh

| ****

4,56

| ****

kW

| ****

Seasonal space heating energy efficiency

| ****

ηs

| ****

155

| ****

%

Annual energy consumption| QHE| 2841| kWh| Emissions of nitrogen oxides| NOx| –| mg/kWh
Declared capacity for heating| Declared coefficient of performance for heating
Tj = – 7 °C| Pdh| 2,76| kW| Tj = – 7 °C| COPd| 3,49| –
Tj = + 2 °C| Pdh| 1,77| kW| Tj = + 2 °C| COPd| 4,95| –
Tj = + 7 °C| Pdh| 1,17| kW| Tj = + 7 °C| COPd| 5,53| –
Tj =+12°C| Pdh| 1,43| kW| Tj =+12°C| COPd| 6,40| –
T j = THP,off| Pdh| 2,54| kW| T j = THP,off| COPd| 3,81| –
T j = Tfb,off| Pdh| 2,54| kW| T j = Tfb,off| COPd| 3,81| –
For air-to-water heat pumps: Tj = – 15 °C (if TOL < – 20 °C)| Pdh| 3,724| kW| For air-to-water HP : Operation limit temperature (maximum

-7°C)

| COPd| –| –
Switch temperature heat pump off| Thp,off| -15| °C| Switch temperature boiler off| Tfb,off| -15| °C
Degradation coefficient (4)| Cdh| 0,90| —|
Heat pump: poer input in modes other than active|  | Boiler
Off mode| POFF| 0,014| kW| Useful heat output at rated heat output and high temperature regime (3)| P4| 27,9| kW


Thermostat-off mode

| PTO| ****

0,024

| ****

kW

| Useful heat output at 30% of rated heat output and high tempera- ture regime (3)| P1| ****

8,1

| ****

kW


Standby mode

| PSB| ****

0,014

| ****

kW

| Useful efficiency at rated heat output and high temperature

regime (3)

| h4| ****

88,06

| ****

%


Crankcase heater mode

| PCK| ****

0

| ****

kW

| Useful efficiency at 30% of rated heat output and high tempera- ture regime (3)| h1| ****

98,64

| ****

%

Other items| Power input of electrical auxiliaries at full load| elmax| 0,032| kW
Capacity control of heat pump| fisso/varia- bile| Variable| Power input of electrical auxiliaries at part load| elmin| 0,013| kW
For air-to-water HP: Rated air flow

rate

| Qairsource| 2770| m3/h| Power input of electrical auxiliaries in stand-by mode| PSB| 0,004| kW
Sound power level, indoors| LWA| –| dB(A)| Stand-by losses| Pstby| 0,042| kW
Sound power level, outdoors| LWA| –| dB(A)| Power input of ignition burner fossil fuel| Pign| 0,000| kW
Contact details| Ferroli s.p.a. via Ritonda 78A – S.Bonifacio (VR) – Italy

Technical data sheet for hybrid heat pump

Model(s):| IDOLA S 3.2 HYBRID 28H 4
Hear source (air, water, brine, direct expansion)| air
Heat sink (water, brine)| water
Tipo di combustibile fossile (liquido / gas)| gas
Low temperature heat pump:| no
Heat pump combination heater:| no
Parameters are declared for low-temperature application (35°C).
Parameters are declared for warmer climate conditions.
Item| Symbol| Value| Unit|  | Item| Symbol| Value| Unit
Rated heat output (3)

at Tdesignh = 2°C

| Prated

= Pdesi- gnh

| ****

5,35

| ****

kW

| ****

Seasonal space heating energy efficiency

| ****

ηs

| ****

258

| ****

%

Annual energy consumption| QHE| 1095| kWh| Emissions of nitrogen oxides| NOx| –| mg/kWh
Declared capacity for heating| Declared coefficient of performance for heating
Tj = – 7 °C| Pdh| –| kW| Tj = – 7 °C| COPd| –| –
Tj = + 2 °C| Pdh| 5,35| kW| Tj = + 2 °C| COPd| 3,95| –
Tj = + 7 °C| Pdh| 3,56| kW| Tj = + 7 °C| COPd| 5,92| –
Tj =+12°C| Pdh| 1,64| kW| Tj =+12°C| COPd| 7,91| –
T j = THP,off| Pdh| 5,35| kW| T j = THP,off| COPd| 3,95| –
T j = Tfb,off| Pdh| 5,35| kW| T j = Tfb,off| COPd| 3,95| –
For air-to-water heat pumps: Tj = – 15 °C (if TOL < – 20 °C)| Pdh| –| kW| For air-to-water HP : Operation limit temperature (maximum

-7°C)

| COPd| –| –
Switch temperature heat pump off| Thp,off| 2| °C| Switch temperature boiler off| Tfb,off| 2| °C
Degradation coefficient (4)| Cdh| 0,90| —|
Heat pump: poer input in modes other than active|  | Boiler
Off mode| POFF| 0,014| kW| Useful heat output at rated heat output and high temperature regime (3)| P4| 27,9| kW


Thermostat-off mode

| PTO| ****

0,024

| ****

kW

| Useful heat output at 30% of rated heat output and high tempera- ture regime (3)| P1| ****

8,1

| ****

kW


Standby mode

| PSB| ****

0,014

| ****

kW

| Useful efficiency at rated heat output and high temperature

regime (3)

| h4| ****

88,06

| ****

%


Crankcase heater mode

| PCK| ****

0

| ****

kW

| Useful efficiency at 30% of rated heat output and high tempera- ture regime (3)| h1| ****

98,64

| ****

%

Other items| Power input of electrical auxiliaries at full load| elmax| 0,032| kW
Capacity control of heat pump| fisso/varia- bile| Variable| Power input of electrical auxiliaries at part load| elmin| 0,013| kW
For air-to-water HP: Rated air flow

rate

| Qairsource| 2770| m3/h| Power input of electrical auxiliaries in stand-by mode| PSB| 0,004| kW
Sound power level, indoors| LWA| –| dB(A)| Stand-by losses| Pstby| 0,042| kW
Sound power level, outdoors| LWA| –| dB(A)| Power input of ignition burner fossil fuel| Pign| 0,000| kW
Contact details| Ferroli s.p.a. via Ritonda 78A – S.Bonifacio (VR) – Italy

IDOLA S 3.2 HYBRID 28H 4 – Media temperature (55°C) / Heating mode – Average climate – Medium temperature (55°C)

The technical data sheet for hybrid heat pump

Model(s):| IDOLA S 3.2 HYBRID 28H 4
Hear source (air, water, brine, direct expansion)| air
Heat sink (water, brine)| water
Tipo di combustibile fossile (liquido / gas)| gas
Low temperature heat pump:| no
Heat pump combination heater:| no
Parameters are declared for medium-temperature application (55°C).
Parameters are declared for average climate conditions.
Item| Symbol| Value| Unit|  | Item| Symbol| Value| Unit
Rated heat output (3)

at Tdesignh = -10°C

| Prated

= Pdesi- gnh

| ****

4,40

| ****

kW

| ****

Seasonal space heating energy efficiency

| ****

ηs

| ****

128

| ****

%

Annual energy consumption| QHE| 2768| kWh| Emissions of nitrogen oxides| NOx| –| mg/kWh
Declared capacity for heating| Declared coefficient of performance for heating
Tj = – 7 °C| Pdh| 3,89| kW| Tj = – 7 °C| COPd| 2,17| –
Tj = + 2 °C| Pdh| 2,38| kW| Tj = + 2 °C| COPd| 3,30| –
Tj = + 7 °C| Pdh| 2,95| kW| Tj = + 7 °C| COPd| 4,03| –
Tj =+12°C| Pdh| 1,32| kW| Tj =+12°C| COPd| 5,17| –
T j = THP,off| Pdh| 3,56| kW| T j = THP,off| COPd| 2,42| –
T j = Tfb,off| Pdh| 3,56| kW| T j = Tfb,off| COPd| 2,42| –
For air-to-water heat pumps: Tj = – 15 °C (if TOL < – 20 °C)| Pdh| –| kW| For air-to-water HP : Operation limit temperature (maximum

-7°C)

| COPd| –| –
Switch temperature heat pump off| Thp,off| -7| °C| Switch temperature boiler off| Tfb,off| -7| °C
Degradation coefficient (4)| Cdh| 0,90| —|
Heat pump: poer input in modes other than active|  | Boiler
Off mode| POFF| 0,014| kW| Useful heat output at rated heat output and high temperature regime (3)| P4| 27,9| kW


Thermostat-off mode

| PTO| ****

0,024

| ****

kW

| Useful heat output at 30% of rated heat output and high tempera- ture regime (3)| P1| ****

8,1

| ****

kW


Standby mode

| PSB| ****

0,014

| ****

kW

| Useful efficiency at rated heat output and high temperature

regime (3)

| h4| ****

88,06

| ****

%


Crankcase heater mode

| PCK| ****

0

| ****

kW

| Useful efficiency at 30% of rated heat output and high tempera- ture regime (3)| h1| ****

98,64

| ****

%

Other items| Power input of electrical auxiliaries at full load| elmax| 0,032| kW
Capacity control of heat pump| fisso/varia- bile| Variable| Power input of electrical auxiliaries at part load| elmin| 0,013| kW
For air-to-water HP: Rated air flow

rate

| Qairsource| 2770| m3/h| Power input of electrical auxiliaries in stand-by mode| PSB| 0,004| kW
Sound power level, indoors| LWA| 39| dB(A)| Stand-by losses| Pstby| 0,042| kW
Sound power level, outdoors| LWA| 56| dB(A)| Power input of ignition burner fossil fuel| Pign| 0,000| kW
Contact details| Ferroli s.p.a. via Ritonda 78A – S.Bonifacio (VR) – Italy

IDOLA S 3.2 HYBRID 28H 4 – Media temperature (55°C) / Heating mode – Colder climate – Medium temperature (55°C)

Technical data sheet for hybrid heat pump

Model(s):| IDOLA S 3.2 HYBRID 28H 4
Hear source (air, water, brine, direct expansion)| air
Heat sink (water, brine)| water
Tipo di combustibile fossile (liquido / gas)| gas
Low temperature heat pump:| no
Heat pump combination heater:| no
Parameters are declared for medium-temperature application (55°C).
Parameters are declared for colder climate conditions.
Item| Symbol| Value| Unit|  | Item| Symbol| Value| Unit
Rated heat output (3)

at Tdesignh = -22°C

| Prated

= Pdesi- gnh

|

3,37

|

kW

|

Seasonal space heating energy efficiency

|

ηs

|

104

|

%

Annual energy consumption| QHE| 3115| kWh| Emissions of nitrogen oxides| NOx| –| mg/kWh
Declared capacity for heating| Declared coefficient of performance for heating
Tj = – 7 °C| Pdh| 2,14| kW| Tj = – 7 °C| COPd| 2,32| –
Tj = + 2 °C| Pdh| 1,28| kW| Tj = + 2 °C| COPd| 2,99| –
Tj = + 7 °C| Pdh| 1,01| kW| Tj = + 7 °C| COPd| 3,76| –
Tj =+12°C| Pdh| 1,36| kW| Tj =+12°C| COPd| 4,89| –
T j = THP,off| Pdh| 1,95| kW| T j = THP,off| COPd| 2,47| –
T j = Tfb,off| Pdh| 1,95| kW| T j = Tfb,off| COPd| 2,47| –
For air-to-water heat pumps: Tj = – 15 °C (if TOL < – 20 °C)| Pdh| 2,748| kW| For air-to-water HP : Operation limit temperature (maximum

-7°C)

| COPd| –| –
Switch temperature heat pump off| Thp,off| -15| °C| Switch temperature boiler off| Tfb,off| -15| °C
Degradation coefficient (4)| Cdh| 0,9| —|
Heat pump: poer input in modes other than active|  | Boiler
Off mode| POFF| 0,014| kW| Useful heat output at rated heat output and high temperature regime (3)| P4| 27,9| kW

Thermostat-off mode

| PTO|

0,024

|

kW

| Useful heat output at 30% of rated heat output and high tempera- ture regime (3)| P1|

8,1

|

kW

Standby mode

| PSB|

0,014

|

kW

| Useful efficiency at rated heat output and high temperature

regime (3)

| h4|

88,06

|

%

Crankcase heater mode

| PCK|

0

|

kW

| Useful efficiency at 30% of rated heat output and high tempera- ture regime (3)| h1|

98,64

|

%

Other items| Power input of electrical auxiliaries at full load| elmax| 0,032| kW
Capacity control of heat pump| fisso/varia- bile| Variable| Power input of electrical auxiliaries at part load| elmin| 0,013| kW
For air-to-water HP: Rated air flow

rate

| Qairsource| 2770| m3/h| Power input of electrical auxiliaries in stand-by mode| PSB| 0,004| kW
Sound power level, indoors| LWA| –| dB(A)| Stand-by losses| Pstby| 0,042| kW
Sound power level, outdoors| LWA| –| dB(A)| Power input of ignition burner fossil fuel| Pign| 0,000| kW
Contact details| Ferroli s.p.a. via Ritonda 78A – S.Bonifacio (VR) – Italy

Technical data sheet for hybrid heat pump

Model(s):| IDOLA S 3.2 HYBRID 28H 4
Hear source (air, water, brine, direct expansion)| air
Heat sink (water, brine)| water
Tipo di combustibile fossile (liquido / gas)| gas
Low temperature heat pump:| no
Heat pump combination heater:| no
Parameters are declared for medium-temperature application (55°C).
Parameters are declared for warmer climate conditions.
Item| Symbol| Value| Unit|  | Item| Symbol| Value| Unit
Rated heat output (3)

at Tdesignh = 2°C

| Prated

= Pdesi- gnh

| ****

4,84

| ****

kW

| ****

Seasonal space heating energy efficiency

| ****

ηs

| ****

164

| ****

%

Annual energy consumption| QHE| 1549| kWh| Emissions of nitrogen oxides| NOx| –| mg/kWh
Declared capacity for heating| Declared coefficient of performance for heating
Tj = – 7 °C| Pdh| –| kW| Tj = – 7 °C| COPd| –| –
Tj = + 2 °C| Pdh| 4,84| kW| Tj = + 2 °C| COPd| 2,52| –
Tj = + 7 °C| Pdh| 3,23| kW| Tj = + 7 °C| COPd| 3,68| –
Tj =+12°C| Pdh| 1,47| kW| Tj =+12°C| COPd| 5,15| –
T j = THP,off| Pdh| 4,84| kW| T j = THP,off| COPd| 2,52| –
T j = Tfb,off| Pdh| 4,84| kW| T j = Tfb,off| COPd| 2,52| –
For air-to-water heat pumps: Tj = – 15 °C (if TOL < – 20 °C)| Pdh| –| kW| For air-to-water HP : Operation limit temperature (maximum

-7°C)

| COPd| –| –
Switch temperature heat pump off| Thp,off| 2| °C| Switch temperature boiler off| Tfb,off| 2| °C
Degradation coefficient (4)| Cdh| 0,9| —|
Heat pump: poer input in modes other than active|  | Boiler
Off mode| POFF| 0,014| kW| Useful heat output at rated heat output and high temperature regime (3)| P4| 27,9| kW


Thermostat-off mode

| PTO| ****

0,024

| ****

kW

| Useful heat output at 30% of rated heat output and high tempera- ture regime (3)| P1| ****

8,1

| ****

kW


Standby mode

| PSB| ****

0,014

| ****

kW

| Useful efficiency at rated heat output and high temperature

regime (3)

| h4| ****

88,06

| ****

%


Crankcase heater mode

| PCK| ****

0

| ****

kW

| Useful efficiency at 30% of rated heat output and high tempera- ture regime (3)| h1| ****

98,64

| ****

%

Other items| Power input of electrical auxiliaries at full load| elmax| 0,032| kW
Capacity control of heat pump| fisso/varia- bile| Variable| Power input of electrical auxiliaries at part load| elmin| 0,013| kW
For air-to-water HP: Rated air flow

rate

| Qairsource| 2770| m3/h| Power input of electrical auxiliaries in stand-by mode| PSB| 0,004| kW
Sound power level, indoors| LWA| –| dB(A)| Stand-by losses| Pstby| 0,042| kW
Sound power level, outdoors| LWA| –| dB(A)| Power input of ignition burner fossil fuel| Pign| 0,000| kW
Contact details| Ferroli s.p.a. via Ritonda 78A – S.Bonifacio (VR) – Italy
Technical data sheet for hybrid heat pump

Model(s):| IDOLA S 3.2 HYBRID 28H 6
Hear source (air, water, brine, direct expansion)| air
Heat sink (water, brine)| water
Tipo di combustibile fossile (liquido / gas)| gas
Low temperature heat pump:| no
Heat pump combination heater:| no
Parameters are declared for low-temperature application (35°C).
Parameters are declared for average climate conditions.
Item| Symbol| Value| Unit|  | Item| Symbol| Value| Unit
Rated heat output (3)

at Tdesignh = -10°C

| Prated

= Pdesi- gnh

| ****

6,82

| ****

kW

| ****

Seasonal space heating energy efficiency

| ****

ηs

| ****

191

| ****

%

Consumo di energia annuale| QHE| 2911| kWh| Emissions of nitrogen oxides| NOx| –| mg/kWh
Declared capacity for heating| Declared coefficient of performance for heating
Tj = – 7 °C| Pdh| 6,03| kW| Tj = – 7 °C| COPd| 3,09| –
Tj = + 2 °C| Pdh| 3,88| kW| Tj = + 2 °C| COPd| 4,85| –
Tj = + 7 °C| Pdh| 2,40| kW| Tj = + 7 °C| COPd| 6,63| –
Tj =+12°C| Pdh| 1,39| kW| Tj =+12°C| COPd| 7,58| –
T j = THP,off| Pdh| 5,55| kW| T j = THP,off| COPd| 3,48| –
T j = Tfb,off| Pdh| 5,55| kW| T j = Tfb,off| COPd| 3,48| –
For air-to-water heat pumps: Tj = – 15 °C (if TOL < – 20 °C)| Pdh| –| kW| For air-to-water HP : Operation limit temperature (maximum

-7°C)

| COPd| –| –
Switch temperature heat pump off| Thp,off| -7| °C| Switch temperature boiler off| Tfb,off| -7| °C
Degradation coefficient (4)| Cdh| 0,90| —|
Heat pump: poer input in modes other than active|  | Boiler
Off mode| POFF| 0,014| kW| Useful heat output at rated heat output and high temperature regime (3)| P4| 27,9| kW


Thermostat-off mode

| PTO| ****

0,024

| ****

kW

| Useful heat output at 30% of rated heat output and high tempera- ture regime (3)| P1| ****

8,1

| ****

kW


Standby mode

| PSB| ****

0,014

| ****

kW

| Useful efficiency at rated heat output and high temperature

regime (3)

| h4| ****

88,06

| ****

%


Crankcase heater mode

| PCK| ****

0

| ****

kW

| Useful efficiency at 30% of rated heat output and high tempera- ture regime (3)| h1| ****

98,64

| ****

%


Other items

| Power input of electrical auxiliaries at full load| ****

elmax

| 0,032| kW
Capacity control of heat pump| fisso/varia- bile| Variable| Power input of electrical auxiliaries at part load| ****

elmin

| 0,013| kW
For air-to-water HP: Rated air flow

rate

| Qairsource| 2770| m3/h| Power input of electrical auxiliaries in stand-by mode| ****

PSB

| 0,004| kW
Sound power level, indoors| LWA| 39| dB(A)| Stand-by losses| Pstby| 0,042| kW
Sound power level, outdoors| LWA| 57| dB(A)| Power input of ignition burner fossil fuel| Pign| 0,000| kW
Contact details| Ferroli s.p.a. via Ritonda 78A – S.Bonifacio (VR) – Italy

Technical data sheet for hybrid heat pump

Model(s):| IDOLA S 3.2 HYBRID 28H 6
Hear source (air, water, brine, direct expansion)| air
Heat sink (water, brine)| water
Tipo di combustibile fossile (liquido / gas)| gas
Low temperature heat pump:| no
Heat pump combination heater:| no
Parameters are declared for low-temperature application (35°C).
Parameters are declared for colder climate conditions.
Item| Symbol| Value| Unit|  | Item| Symbol| Value| Unit
Rated heat output (3)

at Tdesignh = -22°C

| Prated

= Pdesi- gnh

| ****

5,63

| ****

kW

| ****

Seasonal space heating energy efficiency

| ****

ηs

| ****

162

| ****

%

Annual energy consumption| QHE| 3373| kWh| Emissions of nitrogen oxides| NOx| –| mg/kWh
Declared capacity for heating| Declared coefficient of performance for heating
Tj = – 7 °C| Pdh| 3,42| kW| Tj = – 7 °C| COPd| 3,59| –
Tj = + 2 °C| Pdh| 2,06| kW| Tj = + 2 °C| COPd| 5,21| –
Tj = + 7 °C| Pdh| 1,47| kW| Tj = + 7 °C| COPd| 6,24| –
Tj =+12°C| Pdh| 1,44| kW| Tj =+12°C| COPd| 6,71| –
T j = THP,off| Pdh| 3,12| kW| T j = THP,off| COPd| 3,95| –
T j = Tfb,off| Pdh| 3,12| kW| T j = Tfb,off| COPd| 3,95| –
For air-to-water heat pumps: Tj = – 15 °C (if TOL < – 20 °C)| Pdh| 4,596| kW| For air-to-water HP : Operation limit temperature (maximum

-7°C)

| COPd| –| –
Switch temperature heat pump off| Thp,off| -15| °C| Switch temperature boiler off| Tfb,off| -15| °C
Degradation coefficient (4)| Cdh| 0,90| —|
Heat pump: poer input in modes other than active|  | Boiler
Off mode| POFF| 0,014| kW| Useful heat output at rated heat output and high temperature regime (3)| P4| 27,9| kW


Thermostat-off mode

| PTO| ****

0,024

| ****

kW

| Useful heat output at 30% of rated heat output and high tempera- ture regime (3)| P1| ****

8,1

| ****

kW


Standby mode

| PSB| ****

0,014

| ****

kW

| Useful efficiency at rated heat output and high temperature

regime (3)

| h4| ****

88,06

| ****

%


Crankcase heater mode

| PCK| ****

0

| ****

kW

| Useful efficiency at 30% of rated heat output and high tempera- ture regime (3)| h1| ****

98,64

| ****

%

Other items| Power input of electrical auxiliaries at full load| elmax| 0,032| kW
Capacity control of heat pump| fisso/varia- bile| Variable| Power input of electrical auxiliaries at part load| elmin| 0,013| kW
For air-to-water HP: Rated air flow

rate

| Qairsource| 2770| m3/h| Power input of electrical auxiliaries in stand-by mode| PSB| 0,004| kW
Sound power level, indoors| LWA| –| dB(A)| Stand-by losses| Pstby| 0,042| kW
Sound power level, outdoors| LWA| –| dB(A)| Power input of ignition burner fossil fuel| Pign| 0,000| kW
Contact details| Ferroli s.p.a. via Ritonda 78A – S.Bonifacio (VR) – Italy

Technical data sheet for hybrid heat pump

Model(s):| IDOLA S 3.2 HYBRID 28H 6
Hear source (air, water, brine, direct expansion)| air
Heat sink (water, brine)| water
Tipo di combustibile fossile (liquido / gas)| gas
Low temperature heat pump:| no
Heat pump combination heater:| no
Parameters are declared for low-temperature application (35°C).
Parameters are declared for warmer climate conditions.
Item| Symbol| Value| Unit|  | Item| Symbol| Value| Unit
Rated heat output (3)

at Tdesignh = 2°C

| Prated

= Pdesi- gnh

| ****

5,94

| ****

kW

| ****

Seasonal space heating energy efficiency

| ****

ηs

| ****

262

| ****

%

Annual energy consumption| QHE| 1197| kWh| Emissions of nitrogen oxides| NOx| –| mg/kWh
Declared capacity for heating| Declared coefficient of performance for heating
Tj = – 7 °C| Pdh| –| kW| Tj = – 7 °C| COPd| –| –
Tj = + 2 °C| Pdh| 5,94| kW| Tj = + 2 °C| COPd| 3,91| –
Tj = + 7 °C| Pdh| 3,99| kW| Tj = + 7 °C| COPd| 5,89| –
Tj =+12°C| Pdh| 1,80| kW| Tj =+12°C| COPd| 8,21| –
T j = THP,off| Pdh| 5,94| kW| T j = THP,off| COPd| 3,91| –
T j = Tfb,off| Pdh| 5,94| kW| T j = Tfb,off| COPd| 3,91| –
For air-to-water heat pumps: Tj = – 15 °C (if TOL < – 20 °C)| Pdh| –| kW| For air-to-water HP : Operation limit temperature (maximum

-7°C)

| COPd| –| –
Switch temperature heat pump off| Thp,off| 2| °C| Switch temperature boiler off| Tfb,off| 2| °C
Degradation coefficient (4)| Cdh| 0,90| —|
Heat pump: poer input in modes other than active|  | Boiler
Off mode| POFF| 0,014| kW| Useful heat output at rated heat output and high temperature regime (3)| P4| 27,9| kW


Thermostat-off mode

| PTO| ****

0,024

| ****

kW

| Useful heat output at 30% of rated heat output and high tempera- ture regime (3)| P1| ****

8,1

| ****

kW


Standby mode

| PSB| ****

0,014

| ****

kW

| Useful efficiency at rated heat output and high temperature

regime (3)

| h4| ****

88,06

| ****

%


Crankcase heater mode

| PCK| ****

0

| ****

kW

| Useful efficiency at 30% of rated heat output and high tempera- ture regime (3)| h1| ****

98,64

| ****

%

Other items| Power input of electrical auxiliaries at full load| elmax| 0,032| kW
Capacity control of heat pump| fisso/varia- bile| Variable| Power input of electrical auxiliaries at part load| elmin| 0,013| kW
For air-to-water HP: Rated air flow

rate

| Qairsource| 2770| m3/h| Power input of electrical auxiliaries in stand-by mode| PSB| 0,004| kW
Sound power level, indoors| LWA| –| dB(A)| Stand-by losses| Pstby| 0,042| kW
Sound power level, outdoors| LWA| –| dB(A)| Power input of ignition burner fossil fuel| Pign| 0,000| kW
Contact details| Ferroli s.p.a. via Ritonda 78A – S.Bonifacio (VR) – Italy

IDOLA S 3.2 HYBRID 28H 6 – Media temperature (55°C) / Heating mode – Average climate – Medium temperature (55°C)

Technical data sheet for hybrid heat pump

Model(s):| IDOLA S 3.2 HYBRID 28H 6
Hear source (air, water, brine, direct expansion)| air
Heat sink (water, brine)| water
Tipo di combustibile fossile (liquido / gas)| gas
Low temperature heat pump:| no
Heat pump combination heater:| no
Parameters are declared for medium-temperature application (55°C).
Parameters are declared for average climate conditions.
Item| Symbol| Value| Unit|  | Item| Symbol| Value| Unit
Rated heat output (3)

at Tdesignh = -10°C

| Prated

= Pdesi- gnh

| ****

5,70

| ****

kW

| ****

Seasonal space heating energy efficiency

| ****

ηs

| ****

136

| ****

%

Annual energy consumption| QHE| 3381| kWh| Emissions of nitrogen oxides| NOx| –| mg/kWh
Declared capacity for heating| Declared coefficient of performance for heating
Tj = – 7 °C| Pdh| 5,05| kW| Tj = – 7 °C| COPd| 2,17| –
Tj = + 2 °C| Pdh| 3,12| kW| Tj = + 2 °C| COPd| 3,51| –
Tj = + 7 °C| Pdh| 2,09| kW| Tj = + 7 °C| COPd| 4,54| –
Tj =+12°C| Pdh| 1,28| kW| Tj =+12°C| COPd| 5,35| –
T j = THP,off| Pdh| 4,62| kW| T j = THP,off| COPd| 2,47| –
T j = Tfb,off| Pdh| 4,62| kW| T j = Tfb,off| COPd| 2,47| –
For air-to-water heat pumps: Tj = – 15 °C (if TOL < – 20 °C)| Pdh| –| kW| For air-to-water HP : Operation limit temperature (maximum

-7°C)

| COPd| –| –
Switch temperature heat pump off| Thp,off| -7| °C| Switch temperature boiler off| Tfb,off| -7| °C
Degradation coefficient (4)| Cdh| 0,90| —|
Heat pump: poer input in modes other than active|  | Boiler
Off mode| POFF| 0,014| kW| Useful heat output at rated heat output and high temperature regime (3)| P4| 27,9| kW


Thermostat-off mode

| PTO| ****

0,024

| ****

kW

| Useful heat output at 30% of rated heat output and high tempera- ture regime (3)| P1| ****

8,1

| ****

kW


Standby mode

| PSB| ****

0,014

| ****

kW

| Useful efficiency at rated heat output and high temperature

regime (3)

| h4| ****

88,06

| ****

%


Crankcase heater mode

| PCK| ****

0

| ****

kW

| Useful efficiency at 30% of rated heat output and high tempera- ture regime (3)| h1| ****

98,64

| ****

%

Other items| Power input of electrical auxiliaries at full load| elmax| 0,032| kW
Capacity control of heat pump| fisso/varia- bile| Variable| Power input of electrical auxiliaries at part load| elmin| 0,013| kW
For air-to-water HP: Rated air flow

rate

| Qairsource| 2770| m3/h| Power input of electrical auxiliaries in stand-by mode| PSB| 0,004| kW
Sound power level, indoors| LWA| 39| dB(A)| Stand-by losses| Pstby| 0,042| kW
Sound power level, outdoors| LWA| 58| dB(A)| Power input of ignition burner fossil fuel| Pign| 0,000| kW
Contact details| Ferroli s.p.a. via Ritonda 78A – S.Bonifacio (VR) – Italy
Technical data sheet for hybrid heat pump

Model(s):| IDOLA S 3.2 HYBRID 28H 6
Hear source (air, water, brine, direct expansion)| air
Heat sink (water, brine)| water
Tipo di combustibile fossile (liquido / gas)| gas
Low temperature heat pump:| no
Heat pump combination heater:| no
Parameters are declared for medium-temperature application (55°C).
Parameters are declared for colder climate conditions.
Item| Symbol| Value| Unit|  | Item| Symbol| Value| Unit
Rated heat output (3)

at Tdesignh = -22°C

| Prated

= Pdesi- gnh

| ****

4,26

| ****

kW

| ****

Seasonal space heating energy efficiency

| ****

ηs

| ****

112

| ****

%

Annual energy consumption| QHE| 3640| kWh| Emissions of nitrogen oxides| NOx| –| mg/kWh
Declared capacity for heating| Declared coefficient of performance for heating
Tj = – 7 °C| Pdh| 2,70| kW| Tj = – 7 °C| COPd| 2,46| –
Tj = + 2 °C| Pdh| 1,61| kW| Tj = + 2 °C| COPd| 3,36| –
Tj = + 7 °C| Pdh| 1,02| kW| Tj = + 7 °C| COPd| 3,94| –
Tj =+12°C| Pdh| 1,37| kW| Tj =+12°C| COPd| 5,27| –
T j = THP,off| Pdh| 2,46| kW| T j = THP,off| COPd| 2,66| –
T j = Tfb,off| Pdh| 2,46| kW| T j = Tfb,off| COPd| 2,66| –
For air-to-water heat pumps: Tj = – 15 °C (if TOL < – 20 °C)| Pdh| 3,475| kW| For air-to-water HP : Operation limit temperature (maximum

-7°C)

| COPd| –| –
Switch temperature heat pump off| Thp,off| -15| °C| Switch temperature boiler off| Tfb,off| -15| °C
Degradation coefficient (4)| Cdh| 0,9| —|
Heat pump: poer input in modes other than active|  | Boiler
Off mode| POFF| 0,014| kW| Useful heat output at rated heat output and high temperature regime (3)| P4| 27,9| kW


Thermostat-off mode

| PTO| ****

0,024

| ****

kW

| Useful heat output at 30% of rated heat output and high tempera- ture regime (3)| P1| ****

8,1

| ****

kW


Standby mode

| PSB| ****

0,014

| ****

kW

| Useful efficiency at rated heat output and high temperature

regime (3)

| h4| ****

88,06

| ****

%


Crankcase heater mode

| PCK| ****

0

| ****

kW

| Useful efficiency at 30% of rated heat output and high tempera- ture regime (3)| h1| ****

98,64

| ****

%

Other items| Power input of electrical auxiliaries at full load| elmax| 0,032| kW
Capacity control of heat pump| fisso/varia- bile| Variable| Power input of electrical auxiliaries at part load| elmin| 0,013| kW
For air-to-water HP: Rated air flow

rate

| Qairsource| 2770| m3/h| Power input of electrical auxiliaries in stand-by mode| PSB| 0,004| kW
Sound power level, indoors| LWA| –| dB(A)| Stand-by losses| Pstby| 0,042| kW
Sound power level, outdoors| LWA| –| dB(A)| Power input of ignition burner fossil fuel| Pign| 0,000| kW
Contact details| Ferroli s.p.a. via Ritonda 78A – S.Bonifacio (VR) – Italy
Technical data sheet for hybrid heat pump

Model(s):| IDOLA S 3.2 HYBRID 28H 6
Hear source (air, water, brine, direct expansion)| air
Heat sink (water, brine)| water
Tipo di combustibile fossile (liquido / gas)| gas
Low temperature heat pump:| no
Heat pump combination heater:| no
Parameters are declared for medium-temperature application (55°C).
Parameters are declared for warmer climate conditions.
Item| Symbol| Value| Unit|  | Item| Symbol| Value| Unit
Rated heat output (3)

at Tdesignh = 2°C

| Prated

= Pdesi- gnh

| ****

5,03

| ****

kW

| ****

Seasonal space heating energy efficiency

| ****

ηs

| ****

165

| ****

%

Annual energy consumption| QHE| 1601| kWh| Emissions of nitrogen oxides| NOx| –| mg/kWh
Declared capacity for heating| Declared coefficient of performance for heating
Tj = – 7 °C| Pdh| –| kW| Tj = – 7 °C| COPd| –| –
Tj = + 2 °C| Pdh| 5,03| kW| Tj = + 2 °C| COPd| 2,48| –
Tj = + 7 °C| Pdh| 3,31| kW| Tj = + 7 °C| COPd| 3,67| –
Tj =+12°C| Pdh| 1,60| kW| Tj =+12°C| COPd| 5,24| –
T j = THP,off| Pdh| 5,03| kW| T j = THP,off| COPd| 2,48| –
T j = Tfb,off| Pdh| 5,03| kW| T j = Tfb,off| COPd| 2,48| –
For air-to-water heat pumps: Tj = – 15 °C (if TOL < – 20 °C)| Pdh| –| kW| For air-to-water HP : Operation limit temperature (maximum

-7°C)

| COPd| –| –
Switch temperature heat pump off| Thp,off| 2| °C| Switch temperature boiler off| Tfb,off| 2| °C
Degradation coefficient (4)| Cdh| 0,9| —|
Heat pump: poer input in modes other than active|  | Boiler
Off mode| POFF| 0,014| kW| Useful heat output at rated heat output and high temperature regime (3)| P4| 27,9| kW


Thermostat-off mode

| PTO| ****

0,024

| ****

kW

| Useful heat output at 30% of rated heat output and high tempera- ture regime (3)| P1| ****

8,1

| ****

kW


Standby mode

| PSB| ****

0,014

| ****

kW

| Useful efficiency at rated heat output and high temperature

regime (3)

| h4| ****

88,06

| ****

%


Crankcase heater mode

| PCK| ****

0

| ****

kW

| Useful efficiency at 30% of rated heat output and high tempera- ture regime (3)| h1| ****

98,64

| ****

%

Other items| Power input of electrical auxiliaries at full load| elmax| 0,032| kW
Capacity control of heat pump| fisso/varia- bile| Variable| Power input of electrical auxiliaries at part load| elmin| 0,013| kW
For air-to-water HP: Rated air flow

rate

| Qairsource| 2770| m3/h| Power input of electrical auxiliaries in stand-by mode| PSB| 0,004| kW
Sound power level, indoors| LWA| –| dB(A)| Stand-by losses| Pstby| 0,042| kW
Sound power level, outdoors| LWA| –| dB(A)| Power input of ignition burner fossil fuel| Pign| 0,000| kW
Contact details| Ferroli s.p.a. via Ritonda 78A – S.Bonifacio (VR) – Italy

IDOLA S 3.2 HYBRID 28H 8 – Bassa temperature (35°C) / Heating mode – Average climate – Low temperature (35°C)

Technical data sheet for hybrid heat pump

Model(s):| IDOLA S 3.2 HYBRID 28H 8
Hear source (air, water, brine, direct expansion)| air
Heat sink (water, brine)| water
Tipo di combustibile fossile (liquido / gas)| gas
Low temperature heat pump:| no
Heat pump combination heater:| no
Parameters are declared for low-temperature application (35°C).
Parameters are declared for average climate conditions.
Item| Symbol| Value| Unit|  | Item| Symbol| Value| Unit
Rated heat output (3)

at Tdesignh = -10°C

| Prated

= Pdesi- gnh

| ****

8,12

| ****

kW

| ****

Seasonal space heating energy efficiency

| ****

ηs

| ****

200

| ****

%

Annual energy consumption| QHE| 3312| kWh| Emissions of nitrogen oxides| NOx| –| mg/kWh
Declared capacity for heating| Declared coefficient of performance for heating
Tj = – 7 °C| Pdh| 7,19| kW| Tj = – 7 °C| COPd| 3,35| –
Tj = + 2 °C| Pdh| 4,65| kW| Tj = + 2 °C| COPd| 5,09| –
Tj = + 7 °C| Pdh| 2,90| kW| Tj = + 7 °C| COPd| 6,81| –
Tj =+12°C| Pdh| 1,63| kW| Tj =+12°C| COPd| 8,10| –
T j = THP,off| Pdh| 6,62| kW| T j = THP,off| COPd| 3,73| –
T j = Tfb,off| Pdh| 6,62| kW| T j = Tfb,off| COPd| 3,73| –
For air-to-water heat pumps: Tj = – 15 °C (if TOL < – 20 °C)| Pdh| –| kW| For air-to-water HP : Operation limit temperature (maximum

-7°C)

| COPd| –| –
Switch temperature heat pump off| Thp,off| -7| °C| Switch temperature boiler off| Tfb,off| -7| °C
Degradation coefficient (4)| Cdh| 0,90| —|
Heat pump: poer input in modes other than active|  | Boiler
Off mode| POFF| 0,014| kW| Useful heat output at rated heat output and high temperature regime (3)| P4| 27,9| kW


Thermostat-off mode

| PTO| ****

0,024

| ****

kW

| Useful heat output at 30% of rated heat output and high tempera- ture regime (3)| P1| ****

8,1

| ****

kW


Standby mode

| PSB| ****

0,014

| ****

kW

| Useful efficiency at rated heat output and high temperature

regime (3)

| h4| ****

88,06

| ****

%


Crankcase heater mode

| PCK| ****

0

| ****

kW

| Useful efficiency at 30% of rated heat output and high tempera- ture regime (3)| h1| ****

98,64

| ****

%

Other items| Power input of electrical auxiliaries at full load| elmax| 0,032| kW
Capacity control of heat pump| fisso/varia- bile| Variable| Power input of electrical auxiliaries at part load| elmin| 0,013| kW
For air-to-water HP: Rated air flow

rate

| Qairsource| 4030| m3/h| Power input of electrical auxiliaries in stand-by mode| PSB| 0,004| kW
Sound power level, indoors| LWA| 39| dB(A)| Stand-by losses| Pstby| 0,042| kW
Sound power level, outdoors| LWA| 59| dB(A)| Power input of ignition burner fossil fuel| Pign| 0,000| kW
Contact details| Ferroli s.p.a. via Ritonda 78A – S.Bonifacio (VR) – Italy
Technical data sheet for hybrid heat pump

Model(s):| IDOLA S 3.2 HYBRID 28H 8
Hear source (air, water, brine, direct expansion)| air
Heat sink (water, brine)| water
Tipo di combustibile fossile (liquido / gas)| gas
Low temperature heat pump:| no
Heat pump combination heater:| no
Parameters are declared for low-temperature application (35°C).
Parameters are declared for colder climate conditions.
Item| Symbol| Value| Unit|  | Item| Symbol| Value| Unit
Rated heat output (3)

at Tdesignh = -22°C

| Prated

= Pdesi- gnh

| ****

6,98

| ****

kW

| ****

Seasonal space heating energy efficiency

| ****

ηs

| ****

165

| ****

%

Annual energy consumption| QHE| 4091| kWh| Emissions of nitrogen oxides| NOx| –| mg/kWh
Declared capacity for heating| Declared coefficient of performance for heating
Tj = – 7 °C| Pdh| 4,46| kW| Tj = – 7 °C| COPd| 3,66| –
Tj = + 2 °C| Pdh| 2,70| kW| Tj = + 2 °C| COPd| 5,21| –
Tj = + 7 °C| Pdh| 1,66| kW| Tj = + 7 °C| COPd| 6,54| –
Tj =+12°C| Pdh| 1,66| kW| Tj =+12°C| COPd| 7,07| –
T j = THP,off| Pdh| 4,07| kW| T j = THP,off| COPd| 4,00| –
T j = Tfb,off| Pdh| 4,07| kW| T j = Tfb,off| COPd| 4,00| –
For air-to-water heat pumps: Tj = – 15 °C (if TOL < – 20 °C)| Pdh| 5,691| kW| For air-to-water HP : Operation limit temperature (maximum

-7°C)

| COPd| –| –
Switch temperature heat pump off| Thp,off| -15| °C| Switch temperature boiler off| Tfb,off| -15| °C
Degradation coefficient (4)| Cdh| 0,90| —|
Heat pump: poer input in modes other than active|  | Boiler
Off mode| POFF| 0,014| kW| Useful heat output at rated heat output and high temperature regime (3)| P4| 27,9| kW


Thermostat-off mode

| PTO| ****

0,024

| ****

kW

| Useful heat output at 30% of rated heat output and high tempera- ture regime (3)| P1| ****

8,1

| ****

kW


Standby mode

| PSB| ****

0,014

| ****

kW

| Useful efficiency at rated heat output and high temperature

regime (3)

| h4| ****

88,06

| ****

%


Crankcase heater mode

| PCK| ****

0

| ****

kW

| Useful efficiency at 30% of rated heat output and high tempera- ture regime (3)| h1| ****

98,64

| ****

%

Other items| Power input of electrical auxiliaries at full load| elmax| 0,032| kW
Capacity control of heat pump| fisso/varia- bile| Variable| Power input of electrical auxiliaries at part load| elmin| 0,013| kW
For air-to-water HP: Rated air flow

rate

| Qairsource| 4030| m3/h| Power input of electrical auxiliaries in stand-by mode| PSB| 0,004| kW
Sound power level, indoors| LWA| –| dB(A)| Stand-by losses| Pstby| 0,042| kW
Sound power level, outdoors| LWA| –| dB(A)| Power input of ignition burner fossil fuel| Pign| 0,000| kW
Contact details| Ferroli s.p.a. via Ritonda 78A – S.Bonifacio (VR) – Italy
The technical data sheet for hybrid heat pump

Model(s):| IDOLA S 3.2 HYBRID 28H 8
Hear source (air, water, brine, direct expansion)| air
Heat sink (water, brine)| water
Tipo di combustibile fossile (liquido / gas)| gas
Low temperature heat pump:| no
Heat pump combination heater:| no
Parameters are declared for low-temperature application (35°C).
Parameters are declared for warmer climate conditions.
Item| Symbol| Value| Unit|  | Item| Symbol| Value| Unit
Rated heat output (3)

at Tdesignh = 2°C

| Prated

= Pdesi- gnh

| ****

7,57

| ****

kW

| ****

Seasonal space heating energy efficiency

| ****

ηs

| ****

281

| ****

%

Annual energy consumption| QHE| 1423| kWh| Emissions of nitrogen oxides| NOx| –| mg/kWh
Declared capacity for heating| Declared coefficient of performance for heating
Tj = – 7 °C| Pdh| –| kW| Tj = – 7 °C| COPd| –| –
Tj = + 2 °C| Pdh| 7,57| kW| Tj = + 2 °C| COPd| 3,98| –
Tj = + 7 °C| Pdh| 5,22| kW| Tj = + 7 °C| COPd| 6,26| –
Tj =+12°C| Pdh| 2,45| kW| Tj =+12°C| COPd| 8,91| –
T j = THP,off| Pdh| 7,57| kW| T j = THP,off| COPd| 3,98| –
T j = Tfb,off| Pdh| 7,57| kW| T j = Tfb,off| COPd| 3,98| –
For air-to-water heat pumps: Tj = – 15 °C (if TOL < – 20 °C)| Pdh| –| kW| For air-to-water HP : Operation limit temperature (maximum

-7°C)

| COPd| –| –
Switch temperature heat pump off| Thp,off| 2| °C| Switch temperature boiler off| Tfb,off| 2| °C
Degradation coefficient (4)| Cdh| 0,90| —|
Heat pump: poer input in modes other than active|  | Boiler
Off mode| POFF| 0,014| kW| Useful heat output at rated heat output and high temperature regime (3)| P4| 27,9| kW


Thermostat-off mode

| PTO| ****

0,024

| ****

kW

| Useful heat output at 30% of rated heat output and high tempera- ture regime (3)| P1| ****

8,1

| ****

kW


Standby mode

| PSB| ****

0,014

| ****

kW

| Useful efficiency at rated heat output and high temperature

regime (3)

| h4| ****

88,06

| ****

%


Crankcase heater mode

| PCK| ****

0

| ****

kW

| Useful efficiency at 30% of rated heat output and high tempera- ture regime (3)| h1| ****

98,64

| ****

%

Other items| Power input of electrical auxiliaries at full load| elmax| 0,032| kW
Capacity control of heat pump| fisso/varia- bile| Variable| Power input of electrical auxiliaries at part load| elmin| 0,013| kW
For air-to-water HP: Rated air flow

rate

| Qairsource| 4030| m3/h| Power input of electrical auxiliaries in stand-by mode| PSB| 0,004| kW
Sound power level, indoors| LWA| –| dB(A)| Stand-by losses| Pstby| 0,042| kW
Sound power level, outdoors| LWA| –| dB(A)| Power input of ignition burner fossil fuel| Pign| 0,000| kW
Contact details| Ferroli s.p.a. via Ritonda 78A – S.Bonifacio (VR) – Italy
Technical data sheet for hybrid heat pump

Model(s):| IDOLA S 3.2 HYBRID 28H 8
Hear source (air, water, brine, direct expansion)| air
Heat sink (water, brine)| water
Tipo di combustibile fossile (liquido / gas)| gas
Low temperature heat pump:| no
Heat pump combination heater:| no
Parameters are declared for medium-temperature application (55°C).
Parameters are declared for colder climate conditions.
Item| Symbol| Value| Unit|  | Item| Symbol| Value| Unit
Rated heat output (3)

at Tdesignh = -22°C

| Prated

= Pdesi- gnh

| ****

5,78

| ****

kW

| ****

Seasonal space heating energy efficiency

| ****

ηs

| ****

113

| ****

%

Annual energy consumption| QHE| 4920| kWh| Emissions of nitrogen oxides| NOx| –| mg/kWh
Declared capacity for heating| Declared coefficient of performance for heating
Tj = – 7 °C| Pdh| 3,86| kW| Tj = – 7 °C| COPd| 2,45| –
Tj = + 2 °C| Pdh| 2,21| kW| Tj = + 2 °C| COPd| 3,35| –
Tj = + 7 °C| Pdh| 1,44| kW| Tj = + 7 °C| COPd| 4,11| –
Tj =+12°C| Pdh| 1,47| kW| Tj =+12°C| COPd| 5,19| –
T j = THP,off| Pdh| 3,50| kW| T j = THP,off| COPd| 2,65| –
T j = Tfb,off| Pdh| 3,50| kW| T j = Tfb,off| COPd| 2,65| –
For air-to-water heat pumps: Tj = – 15 °C (if TOL < – 20 °C)| Pdh| 4,713| kW| For air-to-water HP : Operation limit temperature (maximum

-7°C)

| COPd| –| –
Switch temperature heat pump off| Thp,off| -15| °C| Switch temperature boiler off| Tfb,off| -15| °C
Degradation coefficient (4)| Cdh| 0,9| —|
Heat pump: poer input in modes other than active|  | Boiler
Off mode| POFF| 0,014| kW| Useful heat output at rated heat output and high temperature regime (3)| P4| 27,9| kW


Thermostat-off mode

| PTO| ****

0,024

| ****

kW

| Useful heat output at 30% of rated heat output and high tempera- ture regime (3)| P1| ****

8,1

| ****

kW


Standby mode

| PSB| ****

0,014

| ****

kW

| Useful efficiency at rated heat output and high temperature

regime (3)

| h4| ****

88,06

| ****

%


Crankcase heater mode

| PCK| ****

0

| ****

kW

| Useful efficiency at 30% of rated heat output and high tempera- ture regime (3)| h1| ****

98,64

| ****

%

Other items| Power input of electrical auxiliaries at full load| elmax| 0,032| kW
Capacity control of heat pump| fisso/varia- bile| Variable| Power input of electrical auxiliaries at part load| elmin| 0,013| kW
For air-to-water HP: Rated air flow

rate

| Qairsource| 4030| m3/h| Power input of electrical auxiliaries in stand-by mode| PSB| 0,004| kW
Sound power level, indoors| LWA| –| dB(A)| Stand-by losses| Pstby| 0,042| kW
Sound power level, outdoors| LWA| –| dB(A)| Power input of ignition burner fossil fuel| Pign| 0,000| kW
Contact details| Ferroli s.p.a. via Ritonda 78A – S.Bonifacio (VR) – Italy
Technical data sheet for hybrid heat pump

Model(s):| IDOLA S 3.2 HYBRID 28H 8
Hear source (air, water, brine, direct expansion)| air
Heat sink (water, brine)| water
Tipo di combustibile fossile (liquido / gas)| gas
Low temperature heat pump:| no
Heat pump combination heater:| no
Parameters are declared for medium-temperature application (55°C).
Parameters are declared for warmer climate conditions.
Item| Symbol| Value| Unit|  | Item| Symbol| Value| Unit
Rated heat output (3)

at Tdesignh = 2°C

| Prated

= Pdesi- gnh

| ****

7,55

| ****

kW

| ****

Seasonal space heating energy efficiency

| ****

ηs

| ****

176

| ****

%

Annual energy consumption| QHE| 2254| kWh| Emissions of nitrogen oxides| NOx| –| mg/kWh
Declared capacity for heating| Declared coefficient of performance for heating
Tj = – 7 °C| Pdh| –| kW| Tj = – 7 °C| COPd| –| –
Tj = + 2 °C| Pdh| 7,55| kW| Tj = + 2 °C| COPd| 2,59| –
Tj = + 7 °C| Pdh| 4,86| kW| Tj = + 7 °C| COPd| 3,92| –
Tj =+12°C| Pdh| 2,32| kW| Tj =+12°C| COPd| 5,55| –
T j = THP,off| Pdh| 7,55| kW| T j = THP,off| COPd| 2,59| –
T j = Tfb,off| Pdh| 7,55| kW| T j = Tfb,off| COPd| 2,59| –
For air-to-water heat pumps: Tj = – 15 °C (if TOL < – 20 °C)| Pdh| –| kW| For air-to-water HP : Operation limit temperature (maximum

-7°C)

| COPd| –| –
Switch temperature heat pump off| Thp,off| 2| °C| Switch temperature boiler off| Tfb,off| 2| °C
Degradation coefficient (4)| Cdh| 0,9| —|
Heat pump: poer input in modes other than active|  | Boiler
Off mode| POFF| 0,014| kW| Useful heat output at rated heat output and high temperature regime (3)| P4| 27,9| kW


Thermostat-off mode

| PTO| ****

0,024

| ****

kW

| Useful heat output at 30% of rated heat output and high tempera- ture regime (3)| P1| ****

8,1

| ****

kW


Standby mode

| PSB| ****

0,014

| ****

kW

| Useful efficiency at rated heat output and high temperature

regime (3)

| h4| ****

88,06

| ****

%


Crankcase heater mode

| PCK| ****

0

| ****

kW

| Useful efficiency at 30% of rated heat output and high tempera- ture regime (3)| h1| ****

98,64

| ****

%

Other items| Power input of electrical auxiliaries at full load| elmax| 0,032| kW
Capacity control of heat pump| fisso/varia- bile| Variable| Power input of electrical auxiliaries at part load| elmin| 0,013| kW
For air-to-water HP: Rated air flow

rate

| Qairsource| 4030| m3/h| Power input of electrical auxiliaries in stand-by mode| PSB| 0,004| kW
Sound power level, indoors| LWA| –| dB(A)| Stand-by losses| Pstby| 0,042| kW
Sound power level, outdoors| LWA| –| dB(A)| Power input of ignition burner fossil fuel| Pign| 0,000| kW
Contact details| Ferroli s.p.a. via Ritonda 78A – S.Bonifacio (VR) – Italy

IDOLA S 3.2 HYBRID 28H 8 – Media temperature (55°C) / Heating mode – Colder climate – Medium temperature (55°C)

Technical data sheet for hybrid heat pump

Model(s):| IDOLA S 3.2 HYBRID 28H 10
Hear source (air, water, brine, direct expansion)| air
Heat sink (water, brine)| water
Tipo di combustibile fossile (liquido / gas)| gas
Low temperature heat pump:| no
Heat pump combination heater:| no
Parameters are declared for low-temperature application (35°C).
Parameters are declared for average climate conditions.
Item| Symbol| Value| Unit|  | Item| Symbol| Value| Unit
Rated heat output (3)

at Tdesignh = -10°C

| Prated

= Pdesi- gnh

| ****

9,17

| ****

kW

| ****

Seasonal space heating energy efficiency

| ****

ηs

| ****

201

| ****

%

Annual energy consumption| QHE| 3714| kWh| Emissions of nitrogen oxides| NOx| –| mg/kWh
Declared capacity for heating| Declared coefficient of performance for heating
Tj = – 7 °C| Pdh| 8,11| kW| Tj = – 7 °C| COPd| 3,23| –
Tj = + 2 °C| Pdh| 5,18| kW| Tj = + 2 °C| COPd| 5,09| –
Tj = + 7 °C| Pdh| 3,32| kW| Tj = + 7 °C| COPd| 7,08| –
Tj =+12°C| Pdh| 1,65| kW| Tj =+12°C| COPd| 8,41| –
T j = THP,off| Pdh| 7,46| kW| T j = THP,off| COPd| 3,64| –
T j = Tfb,off| Pdh| 7,46| kW| T j = Tfb,off| COPd| 3,64| –
For air-to-water heat pumps:

Tj = – 15 °C (if TOL < – 20 °C)

| Pdh| –| kW| For air-to-water HP : Operation limit temperature (maximum

-7°C)

| COPd| –| –
Switch temperature heat pump off| Thp,off| -7| °C| Switch temperature boiler off| Tfb,off| -7| °C
Degradation coefficient (4)| Cdh| 0,90| —|
Heat pump: poer input in modes other than active|  | Boiler
Off mode| POFF| 0,014| kW| Useful heat output at rated heat output and high temperature regime (3)| P4| 27,9| kW


Thermostat-off mode

| PTO| ****

0,024

| ****

kW

| Useful heat output at 30% of rated heat output and high tempera- ture regime (3)| P1| ****

8,1

| ****

kW


Standby mode

| PSB| ****

0,014

| ****

kW

| Useful efficiency at rated heat output and high temperature

regime (3)

| h4| ****

88,06

| ****

%


Crankcase heater mode

| PCK| ****

0

| ****

kW

| Useful efficiency at 30% of rated heat output and high tempera- ture regime (3)| h1| ****

98,64

| ****

%

Other items| Power input of electrical auxiliaries at full load| elmax| 0,032| kW
Capacity control of heat pump| fisso/varia- bile| Variable| Power input of electrical auxiliaries at part load| elmin| 0,013| kW
For air-to-water HP: Rated air flow

rate

| Qairsource| 4030| m3/h| Power input of electrical auxiliaries in stand-by mode| PSB| 0,004| kW
Sound power level, indoors| LWA| 39| dB(A)| Stand-by losses| Pstby| 0,042| kW
Sound power level, outdoors| LWA| 60| dB(A)| Power input of ignition burner fossil fuel| Pign| 0,000| kW
Contact details| Ferroli s.p.a. via Ritonda 78A – S.Bonifacio (VR) – Italy
Technical data sheet for hybrid heat pump

Model(s):| IDOLA S 3.2 HYBRID 28H 10
Hear source (air, water, brine, direct expansion)| air
Heat sink (water, brine)| water
Tipo di combustibile fossile (liquido / gas)| gas
Low temperature heat pump:| no
Heat pump combination heater:| no
Parameters are declared for low-temperature application (35°C).
Parameters are declared for colder climate conditions.
Item| Symbol| Value| Unit|  | Item| Symbol| Value| Unit
Rated heat output (3)

at Tdesignh = -22°C

| Prated

= Pdesi- gnh

| ****

7,75

| ****

kW

| ****

Seasonal space heating energy efficiency

| ****

ηs

| ****

165

| ****

%

Annual energy consumption| QHE| 4545| kWh| Emissions of nitrogen oxides| NOx| –| mg/kWh
Declared capacity for heating| Declared coefficient of performance for heating
Tj = – 7 °C| Pdh| 4,83| kW| Tj = – 7 °C| COPd| 3,60| –
Tj = + 2 °C| Pdh| 2,94| kW| Tj = + 2 °C| COPd| 5,26| –
Tj = + 7 °C| Pdh| 1,92| kW| Tj = + 7 °C| COPd| 7,08| –
Tj =+12°C| Pdh| 1,66| kW| Tj =+12°C| COPd| 7,22| –
T j = THP,off| Pdh| 4,41| kW| T j = THP,off| COPd| 3,97| –
T j = Tfb,off| Pdh| 4,41| kW| T j = Tfb,off| COPd| 3,97| –
For air-to-water heat pumps: Tj = – 15 °C (if TOL < – 20 °C)| Pdh| 6,324| kW| For air-to-water HP : Operation limit temperature (maximum

-7°C)

| COPd| –| –
Switch temperature heat pump off| Thp,off| -15| °C| Switch temperature boiler off| Tfb,off| -15| °C
Degradation coefficient (4)| Cdh| 0,90| —|
Heat pump: poer input in modes other than active|  | Boiler
Off mode| POFF| 0,014| kW| Useful heat output at rated heat output and high temperature regime (3)| P4| 27,9| kW


Thermostat-off mode

| PTO| ****

0,024

| ****

kW

| Useful heat output at 30% of rated heat output and high tempera- ture regime (3)| P1| ****

8,1

| ****

kW


Standby mode

| PSB| ****

0,014

| ****

kW

| Useful efficiency at rated heat output and high temperature

regime (3)

| h4| ****

88,06

| ****

%


Crankcase heater mode

| PCK| ****

0

| ****

kW

| Useful efficiency at 30% of rated heat output and high tempera- ture regime (3)| h1| ****

98,64

| ****

%

Other items| Power input of electrical auxiliaries at full load| elmax| 0,032| kW
Capacity control of heat pump| fisso/varia- bile| Variable| Power input of electrical auxiliaries at part load| elmin| 0,013| kW
For air-to-water HP: Rated air flow

rate

| Qairsource| 4030| m3/h| Power input of electrical auxiliaries in stand-by mode| PSB| 0,004| kW
Sound power level, indoors| LWA| –| dB(A)| Stand-by losses| Pstby| 0,042| kW
Sound power level, outdoors| LWA| –| dB(A)| Power input of ignition burner fossil fuel| Pign| 0,000| kW
Contact details| Ferroli s.p.a. via Ritonda 78A – S.Bonifacio (VR) – Italy
Technical data sheet for hybrid heat pump

Model(s):| IDOLA S 3.2 HYBRID 28H 10
Hear source (air, water, brine, direct expansion)| air
Heat sink (water, brine)| water
Tipo di combustibile fossile (liquido / gas)| gas
Low temperature heat pump:| no
Heat pump combination heater:| no
Parameters are declared for low-temperature application (35°C).
Parameters are declared for warmer climate conditions.
Item| Symbol| Value| Unit|  | Item| Symbol| Value| Unit
Rated heat output (3)

at Tdesignh = 2°C

| Prated

= Pdesi- gnh

| ****

8,44

| ****

kW

| ****

Seasonal space heating energy efficiency

| ****

ηs

| ****

281

| ****

%

Annual energy consumption| QHE| 1588| kWh| Emissions of nitrogen oxides| NOx| –| mg/kWh
Declared capacity for heating| Declared coefficient of performance for heating
Tj = – 7 °C| Pdh| –| kW| Tj = – 7 °C| COPd| –| –
Tj = + 2 °C| Pdh| 8,44| kW| Tj = + 2 °C| COPd| 3,84| –
Tj = + 7 °C| Pdh| 5,52| kW| Tj = + 7 °C| COPd| 6,18| –
Tj =+12°C| Pdh| 2,62| kW| Tj =+12°C| COPd| 9,04| –
T j = THP,off| Pdh| 8,44| kW| T j = THP,off| COPd| 3,84| –
T j = Tfb,off| Pdh| 8,44| kW| T j = Tfb,off| COPd| 3,84| –
For air-to-water heat pumps: Tj = – 15 °C (if TOL < – 20 °C)| Pdh| –| kW| For air-to-water HP : Operation limit temperature (maximum

-7°C)

| COPd| –| –
Switch temperature heat pump off| Thp,off| 2| °C| Switch temperature boiler off| Tfb,off| 2| °C
Degradation coefficient (4)| Cdh| 0,90| —|
Heat pump: poer input in modes other than active|  | Boiler
Off mode| POFF| 0,014| kW| Useful heat output at rated heat output and high temperature regime (3)| P4| 27,9| kW


Thermostat-off mode

| PTO| ****

0,024

| ****

kW

| Useful heat output at 30% of rated heat output and high tempera- ture regime (3)| P1| ****

8,1

| ****

kW


Standby mode

| PSB| ****

0,014

| ****

kW

| Useful efficiency at rated heat output and high temperature

regime (3)

| h4| ****

88,06

| ****

%


Crankcase heater mode

| PCK| ****

0

| ****

kW

| Useful efficiency at 30% of rated heat output and high tempera- ture regime (3)| h1| ****

98,64

| ****

%

Other items| Power input of electrical auxiliaries at full load| elmax| 0,032| kW
Capacity control of heat pump| fisso/varia- bile| Variable| Power input of electrical auxiliaries at part load| elmin| 0,013| kW
For air-to-water HP: Rated air flow

rate

| Qairsource| 4030| m3/h| Power input of electrical auxiliaries in stand-by mode| PSB| 0,004| kW
Sound power level, indoors| LWA| –| dB(A)| Stand-by losses| Pstby| 0,042| kW
Sound power level, outdoors| LWA| –| dB(A)| Power input of ignition burner fossil fuel| Pign| 0,000| kW
Contact details| Ferroli s.p.a. via Ritonda 78A – S.Bonifacio (VR) – Italy
Technical data sheet for hybrid heat pump

Model(s):| IDOLA S 3.2 HYBRID 28H 10
Hear source (air, water, brine, direct expansion)| air
Heat sink (water, brine)| water
Tipo di combustibile fossile (liquido / gas)| gas
Low temperature heat pump:| no
Heat pump combination heater:| no
Parameters are declared for medium-temperature application (55°C).
Parameters are declared for average climate conditions.
Item| Symbol| Value| Unit|  | Item| Symbol| Value| Unit
Rated heat output (3)

at Tdesignh = -10°C

| Prated

= Pdesi- gnh

| ****

7,67

| ****

kW

| ****

Seasonal space heating energy efficiency

| ****

ηs

| ****

135

| ****

%

Annual energy consumption| QHE| 4576| kWh| Emissions of nitrogen oxides| NOx| –| mg/kWh
Declared capacity for heating| Declared coefficient of performance for heating
Tj = – 7 °C| Pdh| 6,78| kW| Tj = – 7 °C| COPd| 2,24| –
Tj = + 2 °C| Pdh| 4,29| kW| Tj = + 2 °C| COPd| 3,42| –
Tj = + 7 °C| Pdh| 2,77| kW| Tj = + 7 °C| COPd| 4,52| –
Tj =+12°C| Pdh| 1,58| kW| Tj =+12°C| COPd| 5,50| –
T j = THP,off| Pdh| 6,23| kW| T j = THP,off| COPd| 2,51| –
T j = Tfb,off| Pdh| 6,23| kW| T j = Tfb,off| COPd| 2,51| –
For air-to-water heat pumps: Tj = – 15 °C (if TOL < – 20 °C)| Pdh| –| kW| For air-to-water HP : Operation limit temperature (maximum

-7°C)

| COPd| –| –
Switch temperature heat pump off| Thp,off| -7| °C| Switch temperature boiler off| Tfb,off| -7| °C
Degradation coefficient (4)| Cdh| 0,90| —|
Heat pump: poer input in modes other than active|  | Boiler
Off mode| POFF| 0,014| kW| Useful heat output at rated heat output and high temperature regime (3)| P4| 27,9| kW


Thermostat-off mode

| PTO| ****

0,024

| ****

kW

| Useful heat output at 30% of rated heat output and high tempera- ture regime (3)| P1| ****

8,1

| ****

kW


Standby mode

| PSB| ****

0,014

| ****

kW

| Useful efficiency at rated heat output and high temperature

regime (3)

| h4| ****

88,06

| ****

%


Crankcase heater mode

| PCK| ****

0

| ****

kW

| Useful efficiency at 30% of rated heat output and high tempera- ture regime (3)| h1| ****

98,64

| ****

%

Other items| Power input of electrical auxiliaries at full load| elmax| 0,032| kW
Capacity control of heat pump| fisso/varia- bile| Variable| Power input of electrical auxiliaries at part load| elmin| 0,013| kW
For air-to-water HP: Rated air flow

rate

| Qairsource| 4030| m3/h| Power input of electrical auxiliaries in stand-by mode| PSB| 0,004| kW
Sound power level, indoors| LWA| 39| dB(A)| Stand-by losses| Pstby| 0,042| kW
Sound power level, outdoors| LWA| 60| dB(A)| Power input of ignition burner fossil fuel| Pign| 0,000| kW
Contact details| Ferroli s.p.a. via Ritonda 78A – S.Bonifacio (VR) – Italy
Technical data sheet for hybrid heat pump

Model(s):| IDOLA S 3.2 HYBRID 28H 10
Hear source (air, water, brine, direct expansion)| air
Heat sink (water, brine)| water
Tipo di combustibile fossile (liquido / gas)| gas
Low temperature heat pump:| no
Heat pump combination heater:| no
Parameters are declared for medium-temperature application (55°C).
Parameters are declared for colder climate conditions.
Item| Symbol| Value| Unit|  | Item| Symbol| Value| Unit
Rated heat output (3)

at Tdesignh = -22°C

| Prated

= Pdesi- gnh

| ****

6,71

| ****

kW

| ****

Seasonal space heating energy efficiency

| ****

ηs

| ****

118

| ****

%

Annual energy consumption| QHE| 5491| kWh| Emissions of nitrogen oxides| NOx| –| mg/kWh
Declared capacity for heating| Declared coefficient of performance for heating
Tj = – 7 °C| Pdh| 4,27| kW| Tj = – 7 °C| COPd| 2,54| –
Tj = + 2 °C| Pdh| 2,57| kW| Tj = + 2 °C| COPd| 3,51| –
Tj = + 7 °C| Pdh| 1,66| kW| Tj = + 7 °C| COPd| 4,37| –
Tj =+12°C| Pdh| 1,48| kW| Tj =+12°C| COPd| 5,38| –
T j = THP,off| Pdh| 3,89| kW| T j = THP,off| COPd| 2,76| –
T j = Tfb,off| Pdh| 3,89| kW| T j = Tfb,off| COPd| 2,76| –
For air-to-water heat pumps: Tj = – 15 °C (if TOL < – 20 °C)| Pdh| 5,477| kW| For air-to-water HP : Operation limit temperature (maximum

-7°C)

| COPd| –| –
Switch temperature heat pump off| Thp,off| -15| °C| Switch temperature boiler off| Tfb,off| -15| °C
Degradation coefficient (4)| Cdh| 0,9| —|
Heat pump: poer input in modes other than active|  | Boiler
Off mode| POFF| 0,014| kW| Useful heat output at rated heat output and high temperature regime (3)| P4| 27,9| kW


Thermostat-off mode

| PTO| ****

0,024

| ****

kW

| Useful heat output at 30% of rated heat output and high tempera- ture regime (3)| P1| ****

8,1

| ****

kW


Standby mode

| PSB| ****

0,014

| ****

kW

| Useful efficiency at rated heat output and high temperature

regime (3)

| h4| ****

88,06

| ****

%


Crankcase heater mode

| PCK| ****

0

| ****

kW

| Useful efficiency at 30% of rated heat output and high tempera- ture regime (3)| h1| ****

98,64

| ****

%

Other items| Power input of electrical auxiliaries at full load| elmax| 0,032| kW
Capacity control of heat pump| fisso/varia- bile| Variable| Power input of electrical auxiliaries at part load| elmin| 0,013| kW
For air-to-water HP: Rated air flow

rate

| Qairsource| 4030| m3/h| Power input of electrical auxiliaries in stand-by mode| PSB| 0,004| kW
Sound power level, indoors| LWA| –| dB(A)| Stand-by losses| Pstby| 0,042| kW
Sound power level, outdoors| LWA| –| dB(A)| Power input of ignition burner fossil fuel| Pign| 0,000| kW
Contact details| Ferroli s.p.a. via Ritonda 78A – S.Bonifacio (VR) – Italy
Technical data sheet for hybrid heat pump

Model(s):| IDOLA S 3.2 HYBRID 28H 10
Hear source (air, water, brine, direct expansion)| air
Heat sink (water, brine)| water
Tipo di combustibile fossile (liquido / gas)| gas
Low temperature heat pump:| no
Heat pump combination heater:| no
Parameters are declared for medium-temperature application (55°C).
Parameters are declared for warmer climate conditions.
Item| Symbol| Value| Unit|  | Item| Symbol| Value| Unit
Rated heat output (3)

at Tdesignh = 2°C

| Prated

= Pdesi- gnh

| ****

8,06

| ****

kW

| ****

Seasonal space heating energy efficiency

| ****

ηs

| ****

184

| ****

%

Annual energy consumption| QHE| 2308| kWh| Emissions of nitrogen oxides| NOx| –| mg/kWh
Declared capacity for heating| Declared coefficient of performance for heating
Tj = – 7 °C| Pdh| –| kW| Tj = – 7 °C| COPd| –| –
Tj = + 2 °C| Pdh| 8,06| kW| Tj = + 2 °C| COPd| 2,59| –
Tj = + 7 °C| Pdh| 5,55| kW| Tj = + 7 °C| COPd| 4,09| –
Tj =+12°C| Pdh| 2,53| kW| Tj =+12°C| COPd| 5,82| –
T j = THP,off| Pdh| 8,06| kW| T j = THP,off| COPd| 2,59| –
T j = Tfb,off| Pdh| 8,06| kW| T j = Tfb,off| COPd| 2,59| –
For air-to-water heat pumps: Tj = – 15 °C (if TOL < – 20 °C)| Pdh| –| kW| For air-to-water HP : Operation limit temperature (maximum

-7°C)

| COPd| –| –
Switch temperature heat pump off| Thp,off| 2| °C| Switch temperature boiler off| Tfb,off| 2| °C
Degradation coefficient (4)| Cdh| 0,9| —|
Heat pump: poer input in modes other than active|  | Boiler
Off mode| POFF| 0,014| kW| Useful heat output at rated heat output and high temperature regime (3)| P4| 27,9| kW


Thermostat-off mode

| PTO| ****

0,024

| ****

kW

| Useful heat output at 30% of rated heat output and high tempera- ture regime (3)| P1| ****

8,1

| ****

kW


Standby mode

| PSB| ****

0,014

| ****

kW

| Useful efficiency at rated heat output and high temperature

regime (3)

| h4| ****

88,06

| ****

%


Crankcase heater mode

| PCK| ****

0

| ****

kW

| Useful efficiency at 30% of rated heat output and high tempera- ture regime (3)| h1| ****

98,64

| ****

%

Other items| Power input of electrical auxiliaries at full load| elmax| 0,032| kW
Capacity control of heat pump| fisso/varia- bile| Variable| Power input of electrical auxiliaries at part load| elmin| 0,013| kW
For air-to-water HP: Rated air flow

rate

| Qairsource| 4030| m3/h| Power input of electrical auxiliaries in stand-by mode| PSB| 0,004| kW
Sound power level, indoors| LWA| –| dB(A)| Stand-by losses| Pstby| 0,042| kW
Sound power level, outdoors| LWA| –| dB(A)| Power input of ignition burner fossil fuel| Pign| 0,000| kW
Contact details| Ferroli s.p.a. via Ritonda 78A – S.Bonifacio (VR) – Italy

ERP TECHNICAL DATA SHEET FOR SPACE COOLING

IDOLA S 3.2 HYBRID 28H 4 – Bassa temperature (7°C) / Cooling mode – Average climate – Low temperature (7°C)

Model(s): IDOLA S 3.2 HYBRID 28H 4
Outdoor side heat exchanger of chiller: Air to water
Indoor side heat exchanger chiller: Water
Type: Compressor driven vapour compression
Driver of compressor: Electric motor

Item| Symbol| Value| Unit|  | Item| Symbol| Value| Unit
Rated cooling capacity| Prated,c| 4.7| kW| Seasonal space cooling energy efficiency| ηs,c| 197| %
Declared cooling capacity for part load at given outdoor temperature Tj| Declared energy efficiency ratio for part load at given outdoor temperature Tj
Tj=+35℃| Pdc| 4.66| kW| Tj=+35℃| EERd| 3.52| –
Tj=+30℃| Pdc| 3.66| kW| Tj=+30℃| EERd| 4.76| –
Tj=+25℃| Pdc| 2.21| kW| Tj=+25℃| EERd| 5.72| –
Tj=+20℃| Pdc| 0.94| kW| Tj=+20℃| EERd| 5.72| –

Degradation co-efficient for chillers (*)| Cdc| 0.9| –|  |  |  |  |
Power consumption in modes other than “active mode”
Off mode| POFF| 0.014| kW|  | Crankcase heater mode| PCK| 0.000| kW
Thermosat-off mode| PTO| 0.010| kW| Standby mode| PSB| 0.014| kW
Other items
Capacity control| variable|  | For air-to-water comfort chillers: air flow rate, outdoor measured| ****


| ****


2770

| ****


m3/h

Sound power level, indoors / outdoors| LWA| ****

39 / 56

| dB

Emissions of nitroge oxides (if applicable)| n NOx (**)| –| mg/kWh input GCV|


For water / brine-to-water

chillers: Rated brine or water flow rate, outdoor

side heat exchanger

| ****


| ****


| ****

m3/h

GWP of the refrigerant| –| 675| kg CO2 eq

(100years)

* Standard rating conditions used| Low-temperature application
Contact details|
Ferroli spa ¬ 37047 San Bonifacio (Verona) Italy ¬ Via Ritonda 78/A – tel. +39.045.6139411 ¬ fax +39.045.6100933 ¬ www.ferroli.com
(
) If Cdc is not determined by measurement then the default degradation coefficient of chillers shall be 0,9. (
) From 26 September 2018.

IDOLA S 3.2 HYBRID 28H 4 – Media temperature (18°C) / Cooling mode – Average climate – Medium temperature (18°C)

Model(s): IDOLA S 3.2 HYBRID 28H 4
Outdoor side heat exchanger of chiller: Air to water
Indoor side heat exchanger chiller: Water
Type: Compressor driven vapour compression
Driver of compressor: Electric motor

Item| Symbol| Value| Unit|  | Item| Symbol| Value| Unit
Rated cooling capacity| Prated,c| 4.5| kW| Seasonal space cooling energy efficiency| ηs,c| 308| %
Declared cooling capacity for part load at given outdoor temperature Tj| Declared energy efficiency ratio for part load at given outdoor temperature Tj
Tj=+35℃| Pdc| 4.51| kW| Tj=+35℃| EERd| 5.54| –
Tj=+30℃| Pdc| 3.44| kW| Tj=+30℃| EERd| 7.23| –
Tj=+25℃| Pdc| 2.19| kW| Tj=+25℃| EERd| 8.94| –
Tj=+20℃| Pdc| 1.13| kW| Tj=+20℃| EERd| 10.48| –

Degradation co-efficient for chillers (*)| Cdc| 0.9| –|  |  |  |  |
Power consumption in modes other than “active mode”
Off mode| POFF| 0.014| kW|  | Crankcase heater mode| PCK| 0.000| kW
Thermosat-off mode| PTO| 0.010| kW| Standby mode| PSB| 0.014| kW
Other items
Capacity control| variable|  | For air-to-water comfort chillers: air flow rate, outdoor measured| ****


| ****


2770

| ****


m3/h

Sound power level, indoors / outdoors| LWA| ****

39 / 56

| dB
Emissions of nitrogen oxides (if applicable)| NOx (**)| –| mg/kWh input GCV|


For water / brine-to-water

chillers: Rated brine or water flow rate, outdoor

side heat exchanger

| ****


| ****


| ****

m3/h

GWP of the refrigerant| –| 675| kg CO2 eq

(100years)


Standard rating conditions used

| ****

Medium temperature application

Contact details| ****

Ferroli spa ¬ 37047 San Bonifacio (Verona) Italy ¬ Via Ritonda 78/A – tel. +39.045.6139411 ¬ fax +39.045.6100933 ¬ www.ferroli.com

(*) If Cdc is not determined by measurement then the default degradation coefficient of chillers shall be 0,9. (**) From 26 September 2018.

IDOLA S 3.2 HYBRID 28H 6 – Bassa temperature (7°C) / Cooling mode – Average climate – Low temperature (7°C)

Model(s): IDOLA S 3.2 HYBRID 28H 6
Outdoor side heat exchanger of chiller: Air to water
Indoor side heat exchanger chiller: Water
Type: Compressor driven vapour compression
Driver of compressor: Electric motor

Item| Symbol| Value| Unit|  | Item| Symbol| Value| Unit
Rated cooling capacity| Prated,c| 6.3| kW| Seasonal space cooling energy efficiency| ηs,c| 211| %
Declared cooling capacity for part load at given outdoor temperature Tj| Declared energy efficiency ratio for part load at given outdoor temperature Tj
Tj=+35℃| Pdc| 6.35| kW| Tj=+35℃| EERd| 2.93| –
Tj=+30℃| Pdc| 4.76| kW| Tj=+30℃| EERd| 4.53| –
Tj=+25℃| Pdc| 3.02| kW| Tj=+25℃| EERd| 6.32| –
Tj=+20℃| Pdc| 1.39| kW| Tj=+20℃| EERd| 7.20| –

Degradation co-efficient for chillers (*)| Cdc| 0.9| –|  |  |  |  |
Power consumption in modes other than “active mode”
Off mode| POFF| 0.014| kW|  | Crankcase heater mode| PCK| 0.000| kW
Thermosat-off mode| PTO| 0.010| kW| Standby mode| PSB| 0.014| kW
Other items
Capacity control| variable|  | For air-to-water comfort chillers: air flow rate, outdoor measured| ****


| ****


2770

| ****


m3/h

Sound power level, indoors / outdoors| LWA| ****

39 / 58

| dB
Emissions of nitrogen oxides (if applicable)| NOx ()| –| mg/kWh input GCV| For water / brine-to-water chillers: Rated brine or water flow rate, outdoor side heat exchanger| **


| ****


| ****

m3/h

GWP of the refrigerant| –| 675| kg CO2 eq

(100years)


Standard rating conditions used

| ****

Low temperature application

Contact details| ****

Ferroli spa ¬ 37047 San Bonifacio (Verona) Italy ¬ Via Ritonda 78/A – tel. +39.045.6139411 ¬ fax +39.045.6100933 ¬ www.ferroli.com

(*) If Cdc is not determined by measurement then the default degradation coefficient of chillers shall be 0,9. (**) From 26 September 2018.

IDOLA S 3.2 HYBRID 28H 6 – Media temperature (18°C) / Cooling mode – Average climate – Medium temperature (18°C)

Model(s): IDOLA S 3.2 HYBRID 28H 6
Outdoor side heat exchanger of chiller: Air to water
Indoor side heat exchanger chiller: Water
Type: Compressor driven vapour compression
Driver of compressor: Electric motor

Item| Symbol| Value| Unit|  | Item| Symbol| Value| Unit
Rated cooling capacity| Prated,c| 6.5| kW| Seasonal space cooling energy efficiency| ηs,c| 325| %
Declared cooling capacity for part load at given outdoor temperature Tj| Declared energy efficiency ratio for part load at given outdoor temperature Tj
Tj=+35℃| Pdc| 6.55| kW| Tj=+35℃| EERd| 4.69| –
Tj=+30℃| Pdc| 4.84| kW| Tj=+30℃| EERd| 7.16| –
Tj=+25℃| Pdc| 3.26| kW| Tj=+25℃| EERd| 9.64| –
Tj=+20℃| Pdc| 1.41| kW| Tj=+20℃| EERd| 11.48| –

Degradation co-efficient for chillers (*)| Cdc| 0.9| –|  |  |  |  |
Power consumption in modes other than “active mode”
Off mode| POFF| 0.014| kW|  | Crankcase heater mode| PCK| 0.000| kW
Thermosat-off mode| PTO| 0.010| kW| Standby mode| PSB| 0.014| kW
Other items
Capacity control| variable|  | For air-to-water comfort chillers: air flow rate, outdoor measured| ****


| ****


2770

| ****


m3/h

Sound power level, indoors / outdoors| LWA| ****

39 / 58

| dB
Emissions of nitrogen oxides (if applicable)| NOx ()| –| mg/kWh input GCV| For water / brine-to-water chillers: Rated brine or water flow rate, outdoor side heat exchanger| **


| ****


| ****

m3/h

GWP of the refrigerant| –| 675| kg CO2 eq

(100years)


Standard rating conditions used

| ****

Medium temperature application

Contact details| ****

Ferroli spa ¬ 37047 San Bonifacio (Verona) Italy ¬ Via Ritonda 78/A – tel. +39.045.6139411 ¬ fax +39.045.6100933 ¬ www.ferroli.com

(*) If Cdc is not determined by measurement then the default degradation coefficient of chillers shall be 0,9. (**) From 26 September 2018.

IDOLA S 3.2 HYBRID 28H 8 – Bassa temperature (7°C) / Cooling mode – Average climate – Low temperature (7°C)

Model(s): IDOLA S 3.2 HYBRID 28H 8
Outdoor side heat exchanger of chiller: Air to water
Indoor side heat exchanger chiller: Water
Type: Compressor driven vapour compression
Driver of compressor: Electric motor

Item| Symbol| Value| Unit|  | Item| Symbol| Value| Unit
Rated cooling capacity| Prated,c| 7.4| kW| Seasonal space cooling energy efficiency| ηs,c| 230| %
Declared cooling capacity for part load at given outdoor temperature Tj| Declared energy efficiency ratio for part load at given outdoor temperature Tj
Tj=+35℃| Pdc| 7.38| kW| Tj=+35℃| EERd| 3.39| –
Tj=+30℃| Pdc| 5.72| kW| Tj=+30℃| EERd| 4.71| –
Tj=+25℃| Pdc| 3.62| kW| Tj=+25℃| EERd| 6.65| –
Tj=+20℃| Pdc| 1.64| kW| Tj=+20℃| EERd| 8.55| –

Degradation co-efficient for chillers (*)| Cdc| 0.9| –|  |  |  |  |
Power consumption in modes other than “active mode”
Off mode| POFF| 0.014| kW|  | Crankcase heater mode| PCK| 0.000| kW
Thermosat-off mode| PTO| 0.010| kW| Standby mode| PSB| 0.014| kW
Other items
Capacity control| variable|  | For air-to-water comfort chillers: air flow rate, outdoor measured| ****


| ****


4030

| ****


m3/h

Sound power level, indoors / outdoors| LWA| ****

39 / 59

| dB
Emissions of nitrogen oxides (if applicable)| NOx ()| –| mg/kWh input GCV| For water / brine-to-water chillers: Rated brine or water flow rate, outdoor side heat exchanger| **


| ****


| ****

m3/h

GWP of the refrigerant| –| 675| kg CO2 eq

(100years)

Standard rating conditions used| Low temperature application
Contact details| Ferroli spa ¬ 37047 San Bonifacio (Verona) Italy ¬ Via Ritonda 78/A – tel. +39.045.6139411 ¬ fax +39.045.6100933 ¬ www.ferroli.com
(*) If Cdc is not determined by measurement then the default degradation coefficient of chillers shall be 0,9. (**) From 26 September 2018.

IDOLA S 3.2 HYBRID 28H 8 – Media temperature (18°C) / Cooling mode – Average climate – Medium temperature (18°C)

Model(s): IDOLA S 3.2 HYBRID 28H 8
Outdoor side heat exchanger of chiller: Air to water
Indoor side heat exchanger chiller: Water
Type: Compressor driven vapour compression
Driver of compressor: Electric motor

Item| Symbol| Value| Unit|  | Item| Symbol| Value| Unit
Rated cooling capacity| Prated,c| 8.4| kW| Seasonal space cooling energy efficiency| ηs,c| 355| %
Declared cooling capacity for part load at given outdoor temperature Tj| Declared energy efficiency ratio for part load at given outdoor temperature Tj
Tj=+35℃| Pdc| 8.37| kW| Tj=+35℃| EERd| 5.09| –
Tj=+30℃| Pdc| 6.47| kW| Tj=+30℃| EERd| 7.02| –
Tj=+25℃| Pdc| 4.31| kW| Tj=+25℃| EERd| 10.67| –
Tj=+20℃| Pdc| 1.80| kW| Tj=+20℃| EERd| 13.61| –

Degradation co-efficient for chillers (*)| Cdc| 0.9| –|  |  |  |  |
Power consumption in modes other than “active mode”
Off mode| POFF| 0.014| kW|  | Crankcase heater mode| PCK| 0.000| kW
Thermosat-off mode| PTO| 0.010| kW| Standby mode| PSB| 0.014| kW
Other items
Capacity control| variable|  | For air-to-water comfort chillers: air flow rate, outdoor measured| ****


| ****


4030

| ****


m3/h

Sound power level, indoors / outdoors| LWA| ****

39 / 59

| dB
Emissions of nitrogen oxides (if applicable)| NOx ()| –| mg/kWh input GCV| For water / brine-to-water chillers: Rated brine or water flow rate, outdoor side heat exchanger| **


| ****


| ****

m3/h

GWP of the refrigerant| –| 675| kg CO2 eq

(100years)


Standard rating conditions used

| ****

Medium temperature application

Contact details| ****

Ferroli spa ¬ 37047 San Bonifacio (Verona) Italy ¬ Via Ritonda 78/A – tel. +39.045.6139411 ¬ fax +39.045.6100933 ¬ www.ferroli.com

(*) If Cdc is not determined by measurement then the default degradation coefficient of chillers shall be 0,9. (**) From 26 September 2018.

IDOLA S 3.2 HYBRID 28H 10 – Bassa temperature (7°C) / Cooling mode – Average climate – Low temperature (7°C)

Model(s): IDOLA S 3.2 HYBRID 28H 10
Outdoor side heat exchanger of chiller: Air to water
Indoor side heat exchanger chiller: Water
Type: Compressor-driven vapour compression
The driver of compressor: Electric motor

Item| Symbol| Value| Unit|  | Item| Symbol| Value| Unit
Rated cooling capacity| Prated,c| 8.7| kW| Seasonal space cooling energy efficiency| ηs,c| 236| %
Declared cooling capacity for part load at given outdoor temperature Tj| Declared energy efficiency ratio for part load at given outdoor temperature Tj
Tj=+35℃| Pdc| 8.73| kW| Tj=+35℃| EERd| 3.21| –
Tj=+30℃| Pdc| 6.68| kW| Tj=+30℃| EERd| 4.47| –
Tj=+25℃| Pdc| 4.26| kW| Tj=+25℃| EERd| 7.02| –
Tj=+20℃| Pdc| 1.94| kW| Tj=+20℃| EERd| 9.54| –

Degradation co-efficient for chillers (*)| Cdc| 0.9| –|  |  |  |  |
Power consumption in modes other than “active mode”
Off mode| POFF| 0.014| kW|  | Crankcase heater mode| PCK| 0.000| kW
Thermosat-off mode| PTO| 0.010| kW| Standby mode| PSB| 0.014| kW
Other items
Capacity control| variable|  | For air-to-water comfort chillers: air flow rate, outdoor measured| ****


| ****


4030

| ****


m3/h

Sound power level, indoors / outdoors| LWA| ****

39 / 60

| dB
Emissions of nitrogen oxides (if applicable)| NOx ()| –| mg/kWh input GCV| For water / brine-to-water chillers: Rated brine or water flow rate, outdoor side heat exchanger| **


| ****


| ****

m3/h

GWP of the refrigerant| –| 675| kg CO2 eq

(100years)

Standard rating conditions used| Low temperature application
Contact details|
Ferroli spa ¬ 37047 San Bonifacio (Verona) Italy ¬ Via Ritonda 78/A – tel. +39.045.6139411 ¬ fax +39.045.6100933 ¬ www.ferroli.com
(*) If Cdc is not determined by measurement then the default degradation coefficient of chillers shall be 0,9. (**) From 26 September 2018.

IDOLA S 3.2 HYBRID 28H 10 – Media temperature (18°C) / Cooling mode – Average climate – Medium temperature (18°C)

Model(s): IDOLA S 3.2 HYBRID 28H 10
Outdoor side heat exchanger of chiller: Air to water
Indoor side heat exchanger chiller: Water
Type: Compressor driven vapour compression
Driver of compressor: Electric motor

Item| Symbol| Value| Unit|  | Item| Symbol| Value| Unit
Rated cooling capacity| Prated,c| 10.0| kW| Seasonal space cooling energy efficiency| ηs,c| 348| %
Declared cooling capacity for part load at given outdoor temperature Tj| Declared energy efficiency ratio for part load at given outdoor temperature Tj
Tj=+35℃| Pdc| 10.01| kW| Tj=+35℃| EERd| 4.64| –
Tj=+30℃| Pdc| 7.71| kW| Tj=+30℃| EERd| 6.45| –
Tj=+25℃| Pdc| 5.03| kW| Tj=+25℃| EERd| 10.36| –
Tj=+20℃| Pdc| 2.32| kW| Tj=+20℃| EERd| 14.98| –

Degradation co-efficient for chillers (*)| Cdc| 0.9| –|  |  |  |  |
Power consumption in modes other than “active mode”
Off mode| POFF| 0.014| kW|  | Crankcase heater mode| PCK| 0.000| kW
Thermosat-off mode| PTO| 0.010| kW| Standby mode| PSB| 0.014| kW
Other items
Capacity control| variable|  | For air-to-water comfort chillers: air flow rate, outdoor measured| ****


| ****


4030

| ****


m3/h

Sound power level, indoors / outdoors| LWA| ****

39 / 60

| dB
Emissions of nitrogen oxides (if applicable)| NOx ()| –| mg/kWh input GCV| For water / brine-to-water chillers: Rated brine or water flow rate, outdoor side heat exchanger| **


| ****


| ****

m3/h

GWP of the refrigerant| –| 675| kg CO2 eq

(100years)


Standard rating conditions used

| ****

Medium temperature application

Contact details| ****

Ferroli spa ¬ 37047 San Bonifacio (Verona) Italy ¬ Via Ritonda 78/A – tel. +39.045.6139411 ¬ fax +39.045.6100933 ¬ www.ferroli.com

(*) If Cdc is not determined by measurement then the default degradation coefficient of chillers shall be 0,9. (**) From 26 September 2018.

CAPACITY TABLES – HEATING MODE

IDOLA S 3.2 HYBRID 28H 4 – Heating capacity

“Tw_out

°C”

| “DB/WB

°C”

| Heating Capacity [W]| COP
---|---|---|---
130%| 100%| 90%| 70%| 50%| 30%| 130%| 100%| 90%| 70%| 50%| 30%

25

| -25| 2053| 1899| 1566| 1232| /| /| 1,74| 1,78| 1,79| 1,80| /| /
-20| 3086| 2824| 2276| 1728| /| /| 2,36| 2,45| 2,48| 2,50| /| /
-15| 3602| 3260| 2989| 2718| 1682| /| 3,03| 3,17| 3,35| 3,53| 3,25| /
-10| 4465| 4001| 3414| 2828| 2241| 1654| 3,36| 3,60| 3,63| 3,65| 3,68| 3,70
-7| 5112| 4678| 3798| 2917| 2037| 1156| 3,67| 3,85| 3,89| 3,93| 3,97| 4,01
-5| 5180| 4692| 3858| 3024| 2190| 1356| 4,03| 4,22| 4,26| 4,30| 4,34| 4,38
-2| 5296| 4841| 3982| 3122| 2263| 1403| 4,55| 4,71| 4,75| 4,80| 4,84| 4,88
0| 5412| 4990| 4105| 3220| 2335| 1450| 5,06| 5,19| 5,24| 5,28| 5,33| 5,37
2| 5629| 5182| 4310| 3439| 2567| 1695| 5,28| 5,45| 5,52| 5,58| 5,65| 5,71
5| 5994| 5479| 4601| 3723| 2844| 1966| 5,83| 6,04| 6,10| 6,16| 6,22| 6,28
7| 6376| 4603| 4215| 3826| 2354| 1955| 6,67| 6,98| 7,41| 7,84| 7,28| 6,96
10| 6370| 5725| 4781| 3837| 2893| 1949| 6,68| 7,13| 7,21| 7,30| 7,38| 7,46
12| 6232| 5625| 4748| 3870| 2992| 2114| 6,69| 7,21| 7,29| 7,39| 7,48| 7,56
15| 6026| 5476| 4698| 3919| 3141| 2362| 6,71| 7,32| 7,42| 7,52| 7,62| 7,72
20| 5864| 5358| 4878| 4398| 2639| /| 7,24| 7,96| 8,48| 9,00| 8,41| /
25| 5701| 5081| 4109| 3136| /| /| 7,91| 8,75| 9,00| 9,25| /| /
30| 5776| 5177| 4249| 3321| /| /| 8,41| 9,37| 9,64| 9,90| /| /
35| 5850| 5290| 4605| 3920| /| /| 8,96| 10,05| 10,34| 10,63| /| /
40| 6298| 5777| 5030| 4282| /| /| 10,84| 12,23| 12,59| 12,94| /| /
43| 6566| 6076| 5304| 4531| /| /| 12,20| 13,87| 14,28| 14,68| /| /

30

| -25| 1796| 1652| 1384| 1115| /| /| 1,48| 1,52| 1,54| 1,55| /| /
-20| 2829| 2575| 2416| 2257| 1528| /| 1,82| 1,86| 1,96| 2,07| 1,90| /
-15| 3407| 3066| 2830| 2595| 1652| /| 2,78| 2,88| 3,04| 3,21| 2,95| /
-10| 4290| 3916| 3375| 2834| 2292| 1751| 3,23| 3,40| 3,43| 3,45| 3,48| 3,50
-7| 5034| 4607| 3751| 2895| 2038| 1182| 3,51| 3,65| 3,68| 3,71| 3,73| 3,76
-5| 5076| 4618| 3803| 2987| 2172| 1356| 3,72| 3,86| 3,89| 3,92| 3,95| 3,98
-2| 5173| 4709| 3890| 3071| 2251| 1432| 4,03| 4,16| 4,19| 4,23| 4,26| 4,29
0| 5269| 4800| 3977| 3154| 2330| 1507| 4,34| 4,46| 4,50| 4,54| 4,57| 4,61
2| 5436| 4944| 4141| 3339| 2536| 1733| 4,51| 4,70| 4,74| 4,79| 4,83| 4,87
5| 5746| 5188| 4388| 3588| 2788| 1988| 4,85| 5,03| 5,08| 5,13| 5,18| 5,23
7| 6222| 4355| 4018| 3682| 2339| 1853| 5,40| 5,65| 6,00| 6,35| 5,89| 5,60
10| 6033| 5281| 4403| 3525| 2646| 1768| 5,16| 5,41| 5,48| 5,54| 5,61| 5,67
12| 5907| 5193| 4385| 3577| 2768| 1960| 5,01| 5,30| 5,37| 5,44| 5,51| 5,57
15| 5717| 5062| 4358| 3655| 2951| 2247| 4,78| 5,13| 5,20| 5,28| 5,35| 5,42
20| 5743| 5113| 4736| 4360| 2814| /| 5,75| 6,22| 6,63| 7,04| 6,58| /
25| 5768| 5237| 4320| 3403| /| /| 7,21| 7,85| 8,08| 8,30| /| /
30| 5836| 5327| 4458| 3589| /| /| 7,48| 8,20| 8,44| 8,68| /| /
35| 5903| 5436| 4725| 4014| /| /| 7,77| 8,57| 8,83| 9,08| /| /
40| 6379| 5773| 5024| 4274| /| /| 9,51| 10,57| 10,88| 11,19| /| /
43| 6665| 6085| 5309| 4532| /| /| 10,80| 12,08| 12,44| 12,80| /| /

35

| -25| 1711| 1560| 1371| 1181| /| /| 1,29| 1,31| 1,32| 1,33| /| /
-20| 2444| 2205| 1812| 1418| /| /| 1,43| 1,48| 1,50| 1,51| /| /
-15| 3253| 2901| 2674| 2447| 1548| /| 2,39| 2,48| 2,62| 2,76| 2,54| /
-10| 4136| 3824| 3296| 2769| 2241| 1713| 2,85| 2,95| 2,97| 3,00| 3,02| 3,04
-7| 4986| 4700| 3837| 2974| 2110| 1247| 3,11| 3,10| 3,16| 3,22| 3,28| 3,34
-5| 5018| 4371| 3632| 2893| 2154| 1415| 3,27| 3,41| 3,44| 3,46| 3,49| 3,51
-2| 5058| 4387| 3645| 2903| 2161| 1419| 3,51| 3,63| 3,66| 3,69| 3,71| 3,74
0| 5098| 4403| 3658| 2913| 2167| 1422| 3,74| 3,85| 3,88| 3,92| 3,95| 3,98
2| 5280| 4400| 3712| 3024| 2335| 1647| 3,87| 4,00| 4,06| 4,12| 4,17| 4,23
5| 5677| 5080| 4291| 3502| 2713| 1924| 4,33| 4,49| 4,53| 4,58| 4,62| 4,66
**7 *| 6255| 4200| 3890| 3579| 2308| 1920| 4,96| 5,10**| 5,43| 5,77| 5,39| 5,01
10| 6067| 5355| 4496| 3636| 2777| 1917| 4,82| 4,97| 5,03| 5,09| 5,15| 5,21
12| 5941| 5267| 4463| 3659| 2855| 2050| 4,73| 4,92| 4,98| 5,05| 5,11| 5,17
15| 5753| 5136| 4414| 3693| 2971| 2249| 4,59| 4,84| 4,91| 4,98| 5,05| 5,12
20| 5774| 5094| 4775| 4456| 3007| /| 5,13| 5,46| 5,82| 6,18| 5,78| /
25| 5805| 5121| 4323| 3525| /| /| 5,85| 6,27| 6,45| 6,63| /| /
30| 5781| 5319| 4553| 3786| /| /| 6,51| 7,01| 7,22| 7,43| /| /
35| 5966| 5538| 4726| 3914| /| /| 7,27| 7,89| 8,13| 8,36| /| /
40| 6359| 5731| 5123| 4515| /| /| 8,57| 9,37| 9,65| 9,93| /| /
43| 6594| 5996| 5372| 4748| /| /| 9,50| 10,46| 10,77| 11,08| /| /

40

| -25| 1531| 1418| 1253| 1087| /| /| 1,18| 1,19| 1,20| 1,20| /| /
-20| 2166| 1984| 1685| 1386| /| /| 1,24| 1,26| 1,28| 1,29| /| /
-15| 2934| 2658| 2151| 1643| /| /| 1,97| 2,02| 2,05| 2,07| /| /
-10| 4017| 3599| 3364| 3128| 2089| /| 2,43| 2,49| 2,63| 2,78| 2,56| /
-7| 4667| 4265| 3873| 3480| 2063| /| 2,70| 2,81| 2,98| 3,16| 2,93| /
-5| 4738| 4214| 3831| 3449| 2056| /| 2,82| 2,96| 3,14| 3,32| 3,07| /
-2| 4827| 4373| 3963| 3554| 2088| /| 3,00| 3,09| 3,28| 3,47| 3,21| /
0| 4916| 4533| 4096| 3659| 2119| /| 3,18| 3,23| 3,42| 3,61| 3,34| /
2| 5183| 4772| 4339| 3906| 2329| /| 3,35| 3,44| 3,66| 3,87| 3,60| /
5| 5588| 5107| 4666| 4226| 2576| /| 3,77| 3,86| 4,09| 4,33| 4,01| /
7| 6259| 4381| 3665| 2948| /| /| 4,41| 4,64| 4,71| 4,78| /| /
10| 5912| 5241| 4843| 4445| 2841| /| 4,63| 4,83| 5,13| 5,44| 5,06| /
12| 5948| 5258| 4870| 4481| 2890| /| 4,79| 5,05| 5,37| 5,70| 5,31| /
15| 6002| 5284| 4910| 4536| 2964| /| 5,04| 5,38| 5,73| 6,08| 5,68| /
20| 6076| 5593| 4736| 3878| /| /| 5,48| 5,89| 6,06| 6,23| /| /
25| 5910| 5473| 4894| 4314| /| /| 6,06| 6,55| 6,75| 6,94| /| /
30| 5886| 5480| 4756| 4032| /| /| 6,39| 6,97| 7,17| 7,37| /| /
35| 5861| 5504| 4774| 4044| /| /| 6,77| 7,43| 7,65| 7,87| /| /
40| 6334| 5777| 5169| 4560| /| /| 7,88| 8,70| 8,96| 9,22| /| /
43| 6617| 6088| 5459| 4830| /| /| 8,63| 9,60| 9,89| 10,17| /| /

45

| -25| 1371| 1285| 1075| 864| /| /| 1,10| 1,09| 1,10| 1,10| /| /
-20| 1976| 1832| 1529| 1225| /| /| 1,13| 1,14| 1,15| 1,15| /| /
-15| 2505| 2222| 1913| 1603| /| /| 1,56| 1,59| 1,60| 1,61| /| /
-10| 3588| 3254| 2714| 2174| /| /| 2,02| 2,05| 2,07| 2,09| /| /
-7| 4538| 4300| 3905| 3510| 2081| /| 2,29| 2,35| 2,49| 2,62| 2,42| /
-5| 4627| 4195| 3844| 3494| 2157| /| 2,45| 2,54| 2,68| 2,83| 2,60| /
-2| 4833| 4327| 3956| 3584| 2190| /| 2,67| 2,77| 2,93| 3,08| 2,83| /
0| 5039| 4460| 4068| 3675| 2222| /| 2,89| 3,00| 3,17| 3,34| 3,07| /
2| 5251| 5100| 4609| 4118| 2387| /| 2,97| 3,00| 3,21| 3,43| 3,23| /
5| 5601| 4824| 4451| 4078| 2591| /| 3,27| 3,42| 3,62| 3,82| 3,52| /
7| 5962| 4300| 3760| 3219| 2800| /| 3,67| 3,80| 3,86| 3,91| 4,00| /
10| 6051| 5477| 5145| 4813| 3274| /| 3,90| 4,05| 4,30| 4,54| 4,21| /
12| 6110| 5555| 4909| 4261| /| /| 4,02| 4,18| 4,37| 4,56| /| /
15| 6199| 5673| 4554| 3434| /| /| 4,21| 4,37| 4,48| 4,58| /| /
20| 6122| 5633| 4715| 3796| /| /| 4,66| 4,88| 5,00| 5,12| /| /
25| 6045| 5668| 5010| 4352| /| /| 5,25| 5,53| 5,67| 5,81| /| /
30| 6020| 5674| 5049| 4424| /| /| 5,62| 5,97| 6,12| 6,27| /| /
35| 5994| 5698| 5067| 4436| /| /| 6,05| 6,47| 6,64| 6,80| /| /
40| 6377| 5890| 5368| 4846| /| /| 6,86| 7,38| 7,57| 7,76| /| /
43| 6606| 6154| 5654| 5153| /| /| 7,39| 8,01| 8,22| 8,42| /| /
“Tw_out

°C”

| “DB/WB

°C”

| Heating Capacity [W]| COP
---|---|---|---
130%| 100%| 90%| 70%| 50%| 30%| 130%| 100%| 90%| 70%| 50%| 30%

50

| -25| /| /| /| /| /| /| /| /| /| /| /| /
-20| 1853| 1725| 1502| 1279| /| /| 1,06| 1,07| 1,08| 1,08| /| /
-15| 2197| 1957| 1737| 1516| /| /| 1,31| 1,34| 1,35| 1,36| /| /
-10| 3280| 2988| 2608| 2227| /| /| 1,81| 1,84| 1,86| 1,88| /| /
-7| 4410| 4125| 3761| 3397| 2051| /| 2,08| 2,14| 2,26| 2,38| 2,18| /
-5| 4565| 4137| 3781| 3424| 2089| /| 2,26| 2,32| 2,45| 2,58| 2,37| /
-2| 4793| 4274| 3907| 3540| 2163| /| 2,37| 2,42| 2,57| 2,72| 2,52| /
0| 5021| 4410| 4033| 3655| 2236| /| 2,48| 2,52| 2,69| 2,86| 2,68| /
2| 5191| 5027| 4553| 4079| 2389| /| 2,52| 2,56| 2,74| 2,92| 2,75| /
5| 5498| 4533| 4223| 3913| 2581| /| 2,78| 2,86| 3,03| 3,19| 2,94| /
7| 5694| 4538| 3879| 3220| /| /| 3,11| 3,32| 3,36| 3,40| /| /
10| 5797| 5195| 4195| 3194| /| /| 3,40| 3,45| 3,50| 3,54| /| /
12| 5746| 5161| 4214| 3266| /| /| 3,50| 3,60| 3,67| 3,73| /| /
15| 5669| 5109| 4242| 3374| /| /| 3,65| 3,83| 3,92| 4,01| /| /
20| 5721| 5267| 4457| 3646| /| /| 3,99| 4,23| 4,34| 4,44| /| /
25| 5683| 5300| 4806| 4312| /| /| 4,39| 4,68| 4,80| 4,92| /| /
30| 5668| 5450| 4921| 4392| /| /| 4,63| 4,97| 5,10| 5,22| /| /
35| 5586| 5416| 4943| 4469| /| /| 4,90| 5,30| 5,44| 5,57| /| /
40| 6001| 5657| 4861| /| /| /| 5,20| 5,67| 5,96| /| /| /
43| 6250| 5941| 5188| /| /| /| 5,38| 5,90| 6,20| /| /| /

55

| -25| /| /| /| /| /| /| /| /| /| /| /| /
-20| 1560| 1501| 1320| 1139| /| /| 0,98| 0,99| 1,00| 1,00| /| /
-15| 1835| 1692| 1470| 1248| /| /| 1,18| 1,20| 1,23| 1,25| /| /
-10| 2629| 2398| 2109| 1819| /| /| 1,56| 1,58| 1,59| 1,60| /| /
-7| 4279| 4000| 3618| 3235| 1882| /| 1,83| 1,95| 2,04| 2,12| 1,91| /
-5| 4412| 4036| 3676| 3316| 1993| /| 1,95| 2,00| 2,11| 2,22| 2,04| /
-2| 4770| 4231| 3857| 3484| 2103| /| 2,16| 2,25| 2,37| 2,49| 2,28| /
0| 5129| 4425| 4038| 3651| 2213| /| 2,37| 2,49| 2,62| 2,75| 2,51| /
2| 5263| 5100| 4635| 4171| 2483| /| 2,42| 2,45| 2,62| 2,78| 2,61| /
5| 5536| 4562| 3678| 2793| /| /| 2,68| 2,75| 2,78| 2,81| /| /
7| 5742| 4400| 4023| 3646| /| /| 2,83| 2,95| 3,05| 3,15| /| /
10| 5699| 4963| 4280| 3596| /| /| 3,16| 3,23| 3,29| 3,35| /| /
12| 5671| 4961| 4370| 3778| /| /| 3,26| 3,35| 3,42| 3,49| /| /
15| 5628| 4957| 4505| 4052| /| /| 3,41| 3,53| 3,62| 3,70| /| /
20| 5522| 4892| 4296| 3700| /| /| 3,68| 3,84| 3,94| 4,04| /| /
25| 5416| 4893| 4391| 3889| /| /| 4,02| 4,23| 4,34| 4,44| /| /
30| 5513| 5008| 4552| 4096| /| /| 4,31| 4,56| 4,68| 4,79| /| /
35| 5610| 5141| 4376| /| /| /| 4,62| 4,92| 5,18| /| /| /
40| /| /| /| /| /| /| /| /| /| /| /| /
43| /| /| /| /| /| /| /| /| /| /| /| /

60

| -25| /| /| /| /| /| /| /| /| /| /| /| /
-20| /| /| /| /| /| /| /| /| /| /| /| /
-15| 1728| 1608| 1418| 1227| /| /| 1,03| 1,03| 1,04| 1,05| /| /
-10| 2811| 2589| 2304| 2018| /| /| 1,56| 1,55| 1,57| 1,58| /| /
-7| 3561| 3149| 2686| 2222| /| /| 1,84| 1,87| 1,89| 1,91| /| /
-5| 3828| 3422| 2856| 2289| /| /| 1,92| 1,95| 1,97| 1,99| /| /
-2| 4113| 3648| 3048| 2448| /| /| 2,00| 2,02| 2,05| 2,07| /| /
0| 4397| 3874| 3241| 2607| /| /| 2,09| 2,09| 2,12| 2,14| /| /
2| 4589| 4036| 3422| 2808| /| /| 2,13| 2,16| 2,20| 2,24| /| /
5| 4902| 4279| 3667| 3054| /| /| 2,35| 2,37| 2,41| 2,44| /| /
7| 5406| 4265| 3911| 3557| /| /| 2,61| 2,65| 2,70| 2,75| /| /
10| 5267| 4841| 4185| 3529| /| /| 2,69| 2,74| 2,80| 2,85| /| /
12| 5175| 4776| 4182| 3588| /| /| 2,76| 2,83| 2,88| 2,91| /| /
15| 5036| 4679| 4178| 3676| /| /| 2,87| 2,97| 2,99| 3,00| /| /
20| 4766| 4452| 3823| 3193| /| /| 3,06| 3,07| 3,15| 3,23| /| /
25| 4495| 4278| 3780| 3281| /| /| 3,30| 3,34| 3,43| 3,52| /| /
30| 4612| 4412| 3947| 3482| /| /| 3,51| 3,57| 3,67| 3,76| /| /
35| /| /| /| /| /| /| /| /| /| /| /| /
40| /| /| /| /| /| /| /| /| /| /| /| /
43| /| /| /| /| /| /| /| /| /| /| /| /

65

| -25| /| /| /| /| /| /| /| /| /| /| /| /
-20| /| /| /| /| /| /| /| /| /| /| /| /
-15| /| /| /| /| /| /| /| /| /| /| /| /
-10| /| /| /| /| /| /| /| /| /| /| /| /
-7| /| /| /| /| /| /| /| /| /| /| /| /
-5| /| /| /| /| /| /| /| /| /| /| /| /
-2| /| /| /| /| /| /| /| /| /| /| /| /
0| /| /| /| /| /| /| /| /| /| /| /| /
2| /| /| /| /| /| /| /| /| /| /| /| /
5| 4040| 3305| 2820| 2335| /| /| 1,87| 1,96| 2,00| 2,04| /| /
7| 4267| 3537| 3121| 2705| /| /| 2,04| 2,16| 2,21| 2,26| /| /
10| 4494| 3667| 3267| 2867| /| /| 2,22| 2,35| 2,40| 2,44| /| /
12| 4646| 3810| 3379| 2948| /| /| 2,36| 2,52| 2,58| 2,62| /| /
15| 4873| 4025| 3548| 3070| /| /| 2,56| 2,77| 2,84| 2,90| /| /
20| /| /| /| /| /| /| /| /| /| /| /| /
25| /| /| /| /| /| /| /| /| /| /| /| /
30| /| /| /| /| /| /| /| /| /| /| /| /
35| /| /| /| /| /| /| /| /| /| /| /| /
40| /| /| /| /| /| /| /| /| /| /| /| /
43| /| /| /| /| /| /| /| /| /| /| /| /

  • : Performance values useful for accessing the incentives provided in Italy / Valori prestazionali utili per accedere agli incentivi previsti in Italia

“Tw_out

°C”

| “DB/WB

°C”

| Heating Capacity [W]| COP
---|---|---|---
130%| 100%| 90%| 70%| 50%| 30%| 130%| 100%| 90%| 70%| 50%| 30%

25

| -25| 2566| 2374| 1957| 1540| /| /| 1,72| 1,76| 1,77| 1,78| /| /
-20| 3642| 3332| 2686| 2039| /| /| 2,34| 2,43| 2,45| 2,47| /| /
-15| 4430| 4010| 3677| 3343| 2069| /| 2,97| 3,11| 3,28| 3,46| 3,18| /
-10| 5753| 5149| 4433| 3717| 3000| 2284| 3,41| 3,61| 3,64| 3,66| 3,69| 3,71
-7| 6553| 6239| 5073| 3906| 2740| 1573| 3,71| 3,86| 3,90| 3,95| 3,99| 4,03
-5| 6536| 5939| 4899| 3859| 2818| 1778| 3,98| 4,17| 4,21| 4,25| 4,28| 4,32
-2| 6515| 5963| 4912| 3861| 2810| 1759| 4,41| 4,57| 4,61| 4,66| 4,70| 4,74
0| 6494| 5987| 4925| 3864| 2802| 1740| 4,85| 4,98| 5,02| 5,07| 5,11| 5,15
2| 6678| 6148| 5113| 4078| 3043| 2008| 4,96| 5,11| 5,17| 5,23| 5,29| 5,35
5| 7038| 6432| 5401| 4370| 3339| 2308| 5,37| 5,56| 5,62| 5,67| 5,73| 5,78
7| 7581| 6753| 5743| 4734| 3724| 2714| 5,87| 6,18| 6,25| 6,31| 6,38| 6,44
10| 7428| 6677| 5576| 4475| 3374| 2273| 6,12| 6,52| 6,60| 6,68| 6,75| 6,83
12| 7326| 6614| 5583| 4551| 3520| 2489| 6,21| 6,68| 6,77| 6,86| 6,94| 7,02
15| 7174| 6520| 5593| 4666| 3739| 2812| 6,35| 6,93| 7,03| 7,12| 7,22| 7,31
20| 6934| 6336| 5768| 5201| 3120| /| 7,15| 7,85| 8,37| 8,88| 8,30| /
25| 6693| 5966| 4824| 3681| /| /| 8,32| 9,21| 9,47| 9,73| /| /
30| 6741| 6042| 4959| 3876| /| /| 9,53| 10,62| 10,93| 11,23| /| /
35| 6789| 6139| 5344| 4549| /| /| 10,34| 11,60| 11,94| 12,27| /| /
40| 7256| 6656| 5795| 4934| /| /| 11,42| 12,89| 13,27| 13,64| /| /
43| 7536| 6973| 6087| 5200| /| /| 12,01| 13,65| 14,05| 14,44| /| /

30

| -25| 2245| 2065| 1730| 1394| /| /| 1,46| 1,51| 1,52| 1,53| /| /
-20| 3339| 3038| 2850| 2663| 1803| /| 1,80| 1,85| 1,95| 2,05| 1,88| /
-15| 4190| 3771| 3481| 3192| 2032| /| 2,73| 2,83| 2,99| 3,15| 2,90| /
-10| 5496| 4891| 4204| 3517| 2830| 2143| 2,99| 3,12| 3,14| 3,17| 3,19| 3,21
-7| 6296| 6053| 4902| 3751| 2599| 1448| 3,28| 3,36| 3,40| 3,43| 3,47| 3,50
-5| 6317| 5890| 4831| 3773| 2714| 1655| 3,52| 3,63| 3,66| 3,70| 3,73| 3,76
-2| 6344| 5877| 4843| 3808| 2774| 1739| 3,92| 4,02| 4,06| 4,10| 4,13| 4,17
0| 6371| 5864| 4854| 3843| 2833| 1822| 4,31| 4,40| 4,45| 4,49| 4,54| 4,58
2| 6477| 5874| 4920| 3965| 3011| 2056| 4,38| 4,50| 4,55| 4,60| 4,64| 4,69
5| 6813| 6062| 5127| 4193| 3258| 2323| 4,51| 4,64| 4,69| 4,73| 4,78| 4,82
7| 7455| 6271| 5367| 4462| 3558| 2653| 4,81| 5,21| 5,25| 5,29| 5,33| 5,37
10| 7268| 6322| 5262| 4202| 3142| 2082| 5,24| 5,49| 5,56| 5,62| 5,69| 5,75
12| 7239| 6341| 5351| 4361| 3371| 2380| 5,47| 5,79| 5,87| 5,94| 6,01| 6,09
15| 7195| 6370| 5485| 4599| 3714| 2828| 5,82| 6,24| 6,33| 6,42| 6,50| 6,59
20| 6966| 6202| 5745| 5288| 3413| /| 6,28| 6,79| 7,24| 7,68| 7,18| /
25| 6736| 6115| 5045| 3974| /| /| 7,16| 7,79| 8,02| 8,24| /| /
30| 6832| 6236| 5219| 4201| /| /| 8,02| 8,79| 9,05| 9,30| /| /
35| 6927| 6379| 5545| 4710| /| /| 9,43| 10,41| 10,72| 11,02| /| /
40| 7373| 6673| 5807| 4940| /| /| 10,15| 11,28| 11,61| 11,94| /| /
43| 7641| 6976| 6086| 5196| /| /| 10,94| 12,24| 12,60| 12,96| /| /

35

| -25| 2139| 1951| 1714| 1476| /| /| 1,28| 1,30| 1,31| 1,32| /| /
-20| 2884| 2602| 2138| 1673| /| /| 1,42| 1,46| 1,48| 1,49| /| /
-15| 4001| 3569| 3290| 3010| 1904| /| 2,34| 2,43| 2,57| 2,71| 2,49| /
-10| 5111| 4508| 3886| 3264| 2641| 2019| 2,57| 2,66| 2,68| 2,70| 2,72| 2,74
-7| 6211| 6000| 4870| 3739| 2609| 1478| 2,86| 3,00| 3,02| 3,03| 3,05| 3,06
-5| 6247| 5716| 4713| 3710| 2706| 1703| 3,09| 3,19| 3,22| 3,25| 3,27| 3,30
-2| 6300| 5726| 4729| 3732| 2735| 1738| 3,44| 3,54| 3,57| 3,60| 3,63| 3,66
0| 6353| 5737| 4746| 3755| 2763| 1772| 3,79| 3,89| 3,92| 3,96| 3,99| 4,02
2| 6531| 5500| 4634| 3768| 2902| 2036| 3,86| 3,90| 3,98| 4,06| 4,14| 4,22
5| 6881| 6158| 5202| 4246| 3289| 2333| 4,25| 4,42| 4,46| 4,51| 4,55| 4,59
**7 *| 7409| 6350| 5446| 4542| 3638| 2734| 4,76| 4,95**| 5,04| 5,14| 5,23| 5,32
10| 7387| 6406| 5447| 4488| 3529| 2570| 4,86| 5,04| 5,12| 5,20| 5,28| 5,36
12| 7354| 6491| 5449| 4408| 3366| 2324| 5,02| 5,17| 5,23| 5,30| 5,36| 5,42
15| 7261| 6482| 5571| 4661| 3750| 2839| 5,28| 5,57| 5,65| 5,73| 5,81| 5,89
20| 6982| 6268| 5875| 5482| 3700| /| 5,91| 6,28| 6,70| 7,11| 6,65| /
25| 6702| 6134| 5178| 4222| /| /| 6,31| 6,75| 6,95| 7,15| /| /
30| 6831| 6286| 5380| 4474| /| /| 7,27| 7,84| 8,07| 8,30| /| /
35| 6959| 6460| 5513| 4565| /| /| 8,17| 8,87| 9,14| 9,40| /| /
40| 7285| 6565| 5869| 5172| /| /| 9,02| 9,86| 10,16| 10,45| /| /
43| 7480| 6801| 6094| 5386| /| /| 9,87| 10,86| 11,19| 11,51| /| /

40

| -25| 1914| 1772| 1566| 1359| /| /| 1,17| 1,17| 1,18| 1,19| /| /
-20| 2556| 2342| 1989| 1636| /| /| 1,23| 1,25| 1,27| 1,28| /| /
-15| 3608| 3269| 2645| 2021| /| /| 1,93| 1,98| 2,01| 2,03| /| /
-10| 4833| 4330| 4047| 3764| 2513| /| 2,22| 2,27| 2,40| 2,54| 2,34| /
-7| 5789| 5606| 4827| 4048| 3269| 2490| 2,50| 2,54| 2,59| 2,63| 2,68| 2,72
-5| 5965| 5652| 5092| 4533| 2589| /| 2,74| 2,87| 3,04| 3,22| 2,98| /
-2| 6230| 5794| 5249| 4704| 2759| /| 3,00| 3,14| 3,32| 3,50| 3,22| /
0| 6495| 5936| 5406| 4876| 2929| /| 3,26| 3,40| 3,59| 3,78| 3,47| /
2| 6645| 5951| 5449| 4947| 3044| /| 3,52| 3,61| 3,84| 4,06| 3,78| /
5| 6962| 6363| 5814| 5265| 3209| /| 3,69| 3,78| 4,01| 4,24| 3,93| /
7| 7128| 6444| 5917| 5391| 3357| /| 3,99| 4,14| 4,40| 4,65| 4,32| /
10| 7371| 6587| 6017| 5447| 3317| /| 4,21| 4,39| 4,67| 4,94| 4,60| /
12| 7453| 6763| 6185| 5606| 3431| /| 4,37| 4,60| 4,90| 5,19| 4,84| /
15| 7577| 7027| 6436| 5845| 3601| /| 4,61| 4,92| 5,24| 5,57| 5,20| /
20| 7212| 6552| 5548| 4543| /| /| 4,70| 5,05| 5,20| 5,34| /| /
25| 6646| 6155| 5504| 4852| /| /| 5,11| 5,53| 5,69| 5,85| /| /
30| 6556| 6104| 5298| 4491| /| /| 6,01| 6,55| 6,75| 6,94| /| /
35| 6465| 6071| 5266| 4461| /| /| 6,87| 7,54| 7,77| 7,99| /| /
40| 7118| 6492| 5809| 5125| /| /| 7,34| 8,11| 8,35| 8,59| /| /
43| 7509| 6909| 6196| 5482| /| /| 8,27| 9,20| 9,48| 9,75| /| /

45

| -25| 1714| 1606| 1343| 1080| /| /| 1,09| 1,08| 1,09| 1,09| /| /
-20| 2332| 2162| 1804| 1446| /| /| 1,12| 1,13| 1,14| 1,14| /| /
-15| 3081| 2733| 2353| 1972| /| /| 1,53| 1,56| 1,57| 1,58| /| /
-10| 4643| 4211| 3513| 2814| /| /| 2,07| 2,10| 2,12| 2,14| /| /
-7| 5573| 5400| 4920| 4440| 2673| /| 2,35| 2,40| 2,54| 2,68| 2,48| /
-5| 5844| 5496| 5036| 4575| 2823| /| 2,54| 2,61| 2,74| 2,87| 2,61| /
-2| 6096| 5586| 5132| 4679| 2921| /| 2,68| 2,78| 2,93| 3,07| 2,81| /
0| 6348| 5675| 5229| 4782| 3020| /| 2,82| 2,94| 3,11| 3,27| 3,01| /
2| 6581| 5800| 5356| 4912| 3131| /| 2,95| 3,00| 3,24| 3,48| 3,32| /
5| 6991| 6131| 5657| 5183| 3293| /| 3,29| 3,45| 3,65| 3,84| 3,54| /
7| 7134| 6300| 5076| 3852| 3546| /| 3,58| 3,70| 3,79| 3,88| 3,92| /
10| 7318| 6624| 6222| 5821| 3959| /| 3,78| 3,83| 4,07| 4,30| 3,99| /
12| 7361| 6766| 5974| 5182| /| /| 3,93| 4,03| 4,21| 4,39| /| /
15| 7425| 6978| 5601| 4224| /| /| 4,16| 4,32| 4,43| 4,53| /| /
20| 7416| 6824| 5711| 4598| /| /| 4,42| 4,62| 4,74| 4,86| /| /
25| 7207| 6758| 5974| 5189| /| /| 4,74| 4,99| 5,12| 5,24| /| /
30| 7049| 6645| 5913| 5181| /| /| 5,05| 5,35| 5,49| 5,63| /| /
35| 6891| 6551| 5825| 5099| /| /| 5,42| 5,79| 5,94| 6,09| /| /
40| 7337| 6777| 6177| 5576| /| /| 6,12| 6,59| 6,76| 6,92| /| /
43| 7605| 7085| 6509| 5932| /| /| 7,02| 7,61| 7,81| 8,00| /| /
“Tw_out

°C”

| “DB/WB

°C”

| Heating Capacity [W]| COP
---|---|---|---
130%| 100%| 90%| 70%| 50%| 30%| 130%| 100%| 90%| 70%| 50%| 30%

50

| -25| /| /| /| /| /| /| /| /| /| /| /| /
-20| 2187| 2036| 1773| 1509| /| /| 1,07| 1,08| 1,09| 1,09| /| /
-15| 2702| 2407| 2136| 1864| /| /| 1,34| 1,37| 1,38| 1,39| /| /
-10| 4127| 3760| 3281| 2802| /| /| 1,72| 1,75| 1,77| 1,78| /| /
-7| 5287| 5068| 4635| 4202| 2572| /| 2,01| 2,07| 2,18| 2,30| 2,11| /
-5| 5440| 5114| 4676| 4237| 2590| /| 2,23| 2,27| 2,41| 2,54| 2,35| /
-2| 5659| 5235| 4824| 4413| 2788| /| 2,36| 2,40| 2,54| 2,68| 2,47| /
0| 5879| 5356| 4972| 4589| 2987| /| 2,48| 2,53| 2,67| 2,82| 2,59| /
2| 6047| 5730| 5316| 4902| 3182| /| 2,54| 2,63| 2,79| 2,95| 2,73| /
5| 6374| 5905| 5519| 5134| 3429| /| 2,81| 2,89| 3,06| 3,23| 2,98| /
7| 6868| 6133| 5196| 4258| /| /| 3,17| 3,29| 3,35| 3,41| /| /
10| 7006| 6474| 5350| 4225| /| /| 3,35| 3,44| 3,51| 3,57| /| /
12| 7098| 6588| 5455| 4321| /| /| 3,48| 3,61| 3,69| 3,76| /| /
15| 7236| 6759| 5612| 4465| /| /| 3,67| 3,86| 3,96| 4,05| /| /
20| 7284| 6840| 5788| 4735| /| /| 4,02| 4,25| 4,36| 4,46| /| /
25| 7332| 7014| 6257| 5499| /| /| 4,43| 4,72| 4,84| 4,96| /| /
30| 6909| 6644| 5999| 5354| /| /| 4,92| 5,28| 5,42| 5,55| /| /
35| 6486| 6289| 5739| 5189| /| /| 5,21| 5,63| 5,78| 5,92| /| /
40| 6928| 6530| 5612| /| /| /| 5,68| 6,19| 6,50| /| /| /
43| 7193| 6838| 5970| /| /| /| 5,96| 6,54| 6,87| /| /| /

55

| -25| /| /| /| /| /| /| /| /| /| /| /| /
-20| 1841| 1771| 1558| 1344| /| /| 0,99| 1,00| 1,01| 1,01| /| /
-15| 2257| 2081| 1808| 1535| /| /| 1,20| 1,22| 1,23| 1,24| /| /
-10| 3797| 3463| 3046| 2628| /| /| 1,69| 1,71| 1,73| 1,74| /| /
-7| 5217| 5150| 4717| 4284| 2639| /| 1,96| 2,00| 2,10| 2,21| 2,01| /
-5| 5305| 5078| 4708| 4338| 2809| /| 2,01| 2,06| 2,18| 2,29| 2,11| /
-2| 5363| 5112| 4740| 4369| 2831| /| 2,05| 2,09| 2,21| 2,33| 2,14| /
0| 5421| 5146| 4772| 4399| 2852| /| 2,09| 2,11| 2,23| 2,35| 2,17| /
2| 5691| 5650| 5240| 4829| 3130| /| 2,41| 2,45| 2,59| 2,73| 2,52| /
5| 6110| 5801| 5447| 5092| 3458| /| 2,48| 2,54| 2,69| 2,84| 2,62| /
7| 6899| 6000| 5191| 4381| /| /| 2,91| 2,95| 3,03| 3,10| /| /
10| 6931| 6036| 5205| 4373| /| /| 3,04| 3,11| 3,17| 3,23| /| /
12| 6952| 6082| 5359| 4635| /|  | 3,14| 3,23| 3,30| 3,37| /|
15| 6984| 6152| 5590| 5028| /| /| 3,30| 3,42| 3,50| 3,58| /| /
20| 6808| 6031| 5296| 4561| /| /| 3,60| 3,76| 3,86| 3,95| /| /
25| 6632| 5991| 5377| 4762| /| /| 4,00| 4,20| 4,31| 4,41| /| /
30| 6603| 5998| 5452| 4906| /| /| 4,21| 4,46| 4,58| 4,69| /| /
35| 6574| 6024| 5128| /| /| /| 4,45| 4,75| 4,99| /| /| /
40| /| /| /| /| /| /| /| /| /| /| /| /
43| /| /| /| /| /| /| /| /| /| /| /| /

60

| -25| /| /| /| /| /| /| /| /| /| /| /| /
-20| /| /| /| /| /| /| /| /| /| /| /| /
-15| 2125| 1978| 1744| 1509| /| /| 1,05| 1,05| 1,06| 1,07| /| /
-10| 3320| 3058| 2721| 2384| /| /| 1,44| 1,44| 1,46| 1,47| /| /
-7| 4573| 4276| 3478| 2679| /| /| 1,75| 1,79| 1,81| 1,82| /| /
-5| 4728| 4345| 3532| 2719| /| /| 1,83| 1,85| 1,88| 1,90| /| /
-2| 4896| 4453| 3657| 2861| /| /| 1,91| 1,92| 1,95| 1,97| /| /
0| 5064| 4561| 3782| 3003| /| /| 1,99| 1,99| 2,02| 2,04| /| /
2| 5334| 4991| 4128| 3264| /| /| 2,05| 2,08| 2,12| 2,16| /| /
5| 5744| 5217| 4398| 3579| /| /| 2,27| 2,29| 2,33| 2,36| /| /
7| 6424| 5644| 4936| 4227| /| /| 2,55| 2,60| 2,65| 2,69| /| /
10| 6270| 5763| 4982| 4201| /| /| 2,60| 2,65| 2,70| 2,75| /| /
12| 6167| 5693| 4984| 4276| /|  | 2,64| 2,71| 2,74| 2,78| /|
15| 6013| 5587| 4988| 4389| /| /| 2,70| 2,79| 2,81| 2,82| /| /
20| 5977| 5584| 4795| 4005| /| /| 3,06| 3,07| 3,15| 3,23| /| /
25| 5941| 5654| 4996| 4337| /| /| 3,55| 3,59| 3,69| 3,78| /| /
30| 6013| 5752| 5146| 4540| /| /| 3,83| 3,91| 4,01| 4,11| /| /
35| /| /| /| /| /| /| /| /| /| /| /| /
40| /| /| /| /| /| /| /| /| /| /| /| /
43| /| /| /| /| /| /| /| /| /| /| /| /

65

| -25| /| /| /| /| /| /| /| /| /| /| /| /
-20| /| /| /| /| /| /| /| /| /| /| /| /
-15| /| /| /| /| /| /| /| /| /| /| /| /
-10| /| /| /| /| /| /| /| /| /| /| /| /
-7| /| /| /| /| /| /| /| /| /| /| /| /
-5| /| /| /| /| /| /| /| /| /| /| /| /
-2| /| /| /| /| /| /| /| /| /| /| /| /
0| /| /| /| /| /| /| /| /| /| /| /| /
2| /| /| /| /| /| /| /| /| /| /| /| /
5| 4924| 4228| 3537| 2846| /| /| 1,84| 1,91| 1,96| 2,01| /| /
7| 5245| 4402| 3864| 3325| /| /| 2,02| 2,14| 2,19| 2,24| /| /
10| 5566| 4542| 4047| 3551| /| /| 2,21| 2,34| 2,39| 2,43| /| /
12| 6101| 5039| 4442| 3844| /| /| 2,56| 2,77| 2,84| 2,90| /| /
15| /| /| /| /| /| /| /| /| /| /| /| /
20| /| /| /| /| /| /| /| /| /| /| /| /
25| /| /| /| /| /| /| /| /| /| /| /| /
30| /| /| /| /| /| /| /| /| /| /| /| /
35| /| /| /| /| /| /| /| /| /| /| /| /
40| /| /| /| /| /| /| /| /| /| /| /| /
43| /| /| /| /| /| /| /| /| /| /| /| /
“Tw_out

°C”

| “DB/WB

°C”

| Heating Capacity [W]| COP
---|---|---|---
130%| 100%| 90%| 70%| 50%| 30%| 130%| 100%| 90%| 70%| 50%| 30%

25

| -25| 4446| 4113| 3391| 2668| /| /| 2,25| 2,29| 2,31| 2,33| /| /
-20| 5683| 5200| 4191| 3182| /| /| 2,80| 2,90| 2,93| 2,96| /| /
-15| 6899| 6244| 5725| 5206| 3222| /| 3,34| 3,49| 3,69| 3,89| 3,58| /
-10| 7446| 6664| 5737| 4810| 3883| 2956| 3,68| 3,89| 3,92| 3,95| 3,98| 4,01
-7| 7637| 7270| 5911| 4552| 3192| 1833| 3,76| 3,97| 4,00| 4,03| 4,06| 4,09
-5| 8047| 7250| 5985| 4720| 3454| 2189| 4,02| 4,25| 4,28| 4,31| 4,34| 4,37
-2| 8296| 7425| 6119| 4812| 3506| 2199| 4,39| 4,57| 4,61| 4,64| 4,68| 4,71
0| 8546| 7600| 6252| 4905| 3557| 2209| 4,77| 4,89| 4,93| 4,98| 5,02| 5,06
2| 8661| 7769| 6461| 5153| 3844| 2536| 5,20| 5,36| 5,43| 5,49| 5,56| 5,62
5| 9033| 8095| 6798| 5500| 4203| 2905| 5,95| 6,17| 6,23| 6,29| 6,35| 6,41
7| 9508| 8595| 7297| 6000| 4702| 3404| 6,54| 6,84| 6,92| 6,99| 7,07| 7,14
10| 10064| 9046| 7555| 6063| 4572| 3080| 7,44| 7,93| 8,02| 8,12| 8,21| 8,30
12| 9982| 9011| 7607| 6203| 4799| 3394| 7,98| 8,59| 8,70| 8,82| 8,92| 9,03
15| 9859| 8959| 7686| 6412| 5139| 3865| 8,79| 9,59| 9,72| 9,86| 9,99| 10,12
20| 9653| 8821| 8031| 7241| 4344| /| 10,14| 11,14| 11,87| 12,60| 11,77| /
25| 9417| 8393| 6786| 5179| /| /| 10,44| 11,55| 11,88| 12,21| /| /
30| 9181| 8229| 6754| 5279| /| /| 11,03| 12,29| 12,64| 12,99| /| /
35| 9548| 8635| 7516| 6397| /| /| 11,31| 12,68| 13,05| 13,42| /| /
40| 10026| 9197| 8007| 6817| /| /| 11,57| 13,06| 13,44| 13,82| /| /
43| 10326| 9555| 8340| 7125| /| /| 12,25| 13,92| 14,33| 14,73| /| /

30

| -25| 3999| 3679| 3082| 2484| /| /| 1,96| 2,03| 2,05| 2,06| /| /
-20| 5087| 4629| 4343| 4057| 2747| /| 2,37| 2,43| 2,57| 2,70| 2,48| /
-15| 6443| 5799| 5354| 4908| 3125| /| 2,87| 2,98| 3,15| 3,32| 3,05| /
-10| 7280| 6479| 5569| 4659| 3749| 2839| 3,33| 3,49| 3,52| 3,54| 3,57| 3,59
-7| 7467| 7109| 5761| 4413| 3065| 1717| 3,40| 3,53| 3,56| 3,58| 3,61| 3,63
-5| 7966| 7205| 5926| 4646| 3367| 2087| 3,69| 3,81| 3,84| 3,88| 3,91| 3,94
-2| 8229| 7495| 6188| 4880| 3573| 2265| 3,96| 4,07| 4,11| 4,14| 4,18| 4,21
0| 8493| 7785| 6450| 5115| 3779| 2444| 4,23| 4,34| 4,38| 4,42| 4,45| 4,49
2| 8649| 7855| 6578| 5302| 4025| 2748| 4,50| 4,64| 4,70| 4,75| 4,81| 4,86
5| 8952| 8083| 6837| 5590| 4344| 3097| 4,94| 5,13| 5,18| 5,23| 5,27| 5,32
7| 9199| 8215| 7026| 5837| 4648| 3459| 5,32| 5,57| 5,63| 5,69| 5,75| 5,81
10| 9278| 8122| 6771| 5420| 4069| 2718| 5,84| 6,12| 6,19| 6,27| 6,34| 6,41
12| 9324| 8200| 6927| 5654| 4380| 3107| 6,34| 6,71| 6,80| 6,89| 6,97| 7,06
15| 9393| 8316| 7160| 6004| 4847| 3691| 7,09| 7,60| 7,71| 7,82| 7,92| 8,03
20| 9507| 8465| 7841| 7218| 4658| /| 8,33| 9,00| 9,59| 10,19| 9,52| /
25| 8998| 8169| 6739| 5309| /| /| 8,75| 9,52| 9,80| 10,07| /| /
30| 8489| 7749| 6485| 5221| /| /| 9,16| 10,04| 10,34| 10,63| /| /
35| 8829| 8130| 7067| 6003| /| /| 9,45| 10,43| 10,74| 11,04| /| /
40| 9270| 8389| 7300| 6211| /| /| 10,02| 11,13| 11,46| 11,79| /| /
43| 9548| 8717| 7605| 6493| /| /| 11,27| 12,61| 12,98| 13,35| /| /

35

| -25| 3590| 3274| 2876| 2477| /| /| 1,64| 1,67| 1,68| 1,69| /| /
-20| 4735| 4271| 3509| 2746| /| /| 2,11| 2,17| 2,20| 2,22| /| /
-15| 6105| 5446| 5020| 4594| 2906| /| 2,43| 2,53| 2,67| 2,82| 2,59| /
-10| 7084| 6248| 5386| 4523| 3661| 2798| 3,15| 3,26| 3,28| 3,31| 3,33| 3,35
-7| 7266| 7000| 5704| 4409| 3113| 1817| 3,21| 3,20| 3,26| 3,32| 3,38| 3,44
-5| 7685| 6994| 5787| 4581| 3374| 2167| 3,22| 3,30| 3,34| 3,37| 3,41| 3,44
-2| 8053| 7332| 6066| 4800| 3534| 2268| 3,49| 3,59| 3,63| 3,66| 3,70| 3,73
0| 8420| 7669| 6344| 5020| 3695| 2370| 3,77| 3,88| 3,91| 3,95| 3,98| 4,01
2| 8477| 7100| 5999| 4897| 3796| 2694| 3,95| 4,10| 4,17| 4,24| 4,30| 4,37
5| 8856| 8084| 6829| 5573| 4318| 3062| 4,56| 4,73| 4,78| 4,82| 4,87| 4,91
**7 *| 9105| 8400| 7140| 5880| 4620| 3360| 5,07| 5,15**| 5,25| 5,35| 5,44| 5,54
10| 8942| 7893| 6626| 5360| 4093| 2826| 5,42| 5,58| 5,65| 5,72| 5,78| 5,85
12| 8999| 7980| 6764| 5549| 4333| 3116| 5,67| 5,90| 5,97| 6,05| 6,12| 6,20
15| 9085| 8111| 6971| 5832| 4692| 3552| 6,04| 6,37| 6,46| 6,55| 6,64| 6,73
20| 9328| 8374| 7849| 7325| 4944| /| 7,09| 7,53| 8,03| 8,53| 7,98| /
25| 8751| 8009| 6761| 5513| /| /| 7,64| 8,18| 8,42| 8,66| /| /
30| 8173| 7521| 6437| 5353| /| /| 7,78| 8,39| 8,64| 8,88| /| /
35| 8500| 7890| 6733| 5576| /| /| 8,05| 8,74| 9,00| 9,26| /| /
40| 8925| 8044| 7191| 6337| /| /| 8,49| 9,28| 9,56| 9,84| /| /
43| 9193| 8358| 7489| 6619| /| /| 9,11| 10,03| 10,33| 10,63| /| /

40

| -25| 3344| 3097| 2736| 2374| /| /| 1,55| 1,56| 1,57| 1,58| /| /
-20| 4320| 3957| 3361| 2765| /| /| 1,77| 1,80| 1,82| 1,83| /| /
-15| 5566| 5043| 4080| 3117| /| /| 2,26| 2,32| 2,35| 2,37| /| /
-10| 6872| 6157| 5754| 5352| 3573| /| 2,62| 2,68| 2,84| 2,99| 2,76| /
-7| 7048| 6710| 6057| 5404| 3115| /| 2,67| 2,79| 2,96| 3,13| 2,90| /
-5| 7451| 6864| 6209| 5554| 3234| /| 2,90| 3,01| 3,20| 3,39| 3,15| /
-2| 7923| 7302| 6601| 5900| 3426| /| 3,11| 3,19| 3,39| 3,58| 3,32| /
0| 8395| 7740| 6993| 6247| 3618| /| 3,32| 3,37| 3,57| 3,77| 3,48| /
2| 8502| 7804| 7094| 6383| 3802| /| 3,40| 3,54| 3,74| 3,94| 3,63| /
5| 8781| 8026| 7333| 6641| 4048| /| 3,84| 3,93| 4,17| 4,41| 4,08| /
7| 8852| 8002| 7348| 6694| 4169| /| 4,18| 4,34| 4,61| 4,88| 4,53| /
10| 8700| 7774| 7101| 6429| 3915| /| 4,30| 4,48| 4,76| 5,05| 4,70| /
12| 8849| 7944| 7264| 6585| 4029| /| 4,63| 4,87| 5,18| 5,50| 5,12| /
15| 9073| 8198| 7509| 6819| 4201| /| 5,12| 5,46| 5,82| 6,17| 5,76| /
20| 9446| 8583| 7267| 5951| /| /| 5,93| 6,37| 6,56| 6,74| /| /
25| 9148| 8472| 7575| 6678| /| /| 6,34| 6,86| 7,06| 7,26| /| /
30| 8849| 8239| 7151| 6062| /| /| 6,84| 7,46| 7,68| 7,89| /| /
35| 9203| 8643| 7497| 6350| /| /| 7,05| 7,74| 7,97| 8,20| /| /
40| 9663| 8814| 7886| 6957| /| /| 7,31| 8,08| 8,32| 8,56| /| /
43| 9953| 9158| 8212| 7266| /| /| 7,86| 8,74| 9,00| 9,26| /| /

45

| -25| 2815| 2638| 2206| 1773| /| /| 1,30| 1,29| 1,29| 1,29| /| /
-20| 3697| 3427| 2860| 2292| /| /| 1,61| 1,62| 1,63| 1,64| /| /
-15| 5288| 4690| 4037| 3384| /| /| 2,00| 2,03| 2,05| 2,06| /| /
-10| 6770| 6141| 5122| 4103| /| /| 2,47| 2,50| 2,53| 2,55| /| /
-7| 6944| 6600| 6053| 5506| 3410| /| 2,52| 2,55| 2,71| 2,87| 2,67| /
-5| 7444| 6791| 6252| 5712| 3595| /| 2,69| 2,75| 2,91| 3,07| 2,84| /
-2| 7767| 6975| 6391| 5806| 3582| /| 2,81| 2,90| 3,07| 3,23| 2,98| /
0| 8090| 7160| 6530| 5900| 3568| /| 2,94| 3,05| 3,22| 3,39| 3,12| /
2| 8308| 7400| 6780| 6161| 3801| /| 3,04| 3,25| 3,43| 3,61| 3,31| /
5| 8694| 7624| 7035| 6445| 4095| /| 3,38| 3,54| 3,74| 3,95| 3,64| /
7| 8979| 8300| 7611| 7122| 4849| /| 3,82| 3,85| 4,13| 4,40| 4,15| /
10| 8735| 7906| 7427| 6948| 4726| /| 3,90| 3,95| 4,19| 4,43| 4,11| /
12| 8805| 8005| 7074| 6143| /| /| 4,09| 4,19| 4,38| 4,57| /| /
15| 8909| 8153| 6545| 4936| /| /| 4,38| 4,55| 4,66| 4,77| /| /
20| 9083| 8358| 6995| 5631| /| /| 5,02| 5,25| 5,38| 5,51| /| /
25| 9007| 8445| 7465| 6485| /| /| 5,80| 6,11| 6,27| 6,42| /| /
30| 8930| 8418| 7491| 6564| /| /| 6,23| 6,61| 6,78| 6,95| /| /
35| 9287| 8829| 7851| 6873| /| /| 6,34| 6,77| 6,95| 7,12| /| /
40| 9752| 9007| 8209| 7411| /| /| 6,46| 6,95| 7,13| 7,31| /| /
43| 10044| 9358| 8596| 7834| /| /| 6,83| 7,40| 7,59| 7,78| /| /
“Tw_out

°C”

| “DB/WB

°C”

| Heating Capacity [W]| COP
---|---|---|---
130%| 100%| 90%| 70%| 50%| 30%| 130%| 100%| 90%| 70%| 50%| 30%

50

| -25| /| /| /| /| /| /| /| /| /| /| /| /
-20| 3175| 2956| 2574| 2191| /| /| 1,41| 1,42| 1,43| 1,44| /| /
-15| 4669| 4160| 3691| 3222| /| /| 1,73| 1,76| 1,78| 1,79| /| /
-10| 6317| 5755| 5022| 4289| /| /| 2,20| 2,23| 2,26| 2,28| /| /
-7| 6479| 6168| 5710| 5253| 3382| /| 2,24| 2,31| 2,44| 2,56| 2,35| /
-5| 7345| 6587| 6143| 5699| 3775| /| 2,46| 2,52| 2,67| 2,81| 2,59| /
-2| 7728| 6988| 6501| 6015| 3948| /| 2,60| 2,66| 2,81| 2,96| 2,72| /
0| 8111| 7389| 6859| 6330| 4120| /| 2,75| 2,79| 2,95| 3,11| 2,86| /
2| 8176| 7369| 6882| 6396| 4260| /| 2,82| 2,91| 3,09| 3,26| 3,02| /
5| 8304| 7499| 7040| 6582| 4468| /| 3,00| 3,09| 3,27| 3,45| 3,18| /
7| 8433| 7531| 6380| 5228| /| /| 3,17| 3,29| 3,35| 3,40| /| /
10| 8280| 7652| 6323| 4993| /| /| 3,42| 3,51| 3,58| 3,65| /| /
12| 8330| 7732| 6402| 5071| /| /| 3,56| 3,69| 3,77| 3,85| /| /
15| 8406| 7852| 6520| 5187| /| /| 3,77| 3,96| 4,06| 4,15| /| /
20| 8532| 8012| 6779| 5546| /| /| 4,22| 4,47| 4,58| 4,69| /| /
25| 8607| 8233| 7344| 6455| /| /| 4,61| 4,91| 5,04| 5,16| /| /
30| 8682| 8349| 7539| 6729| /| /| 4,99| 5,36| 5,50| 5,63| /| /
35| 9029| 8755| 7989| 7223| /| /| 5,21| 5,63| 5,78| 5,92| /| /
40| 9481| 8937| 7679| /| /| /| 5,46| 5,95| 6,25| /| /| /
43| 9765| 9283| 8105| /| /| /| 6,08| 6,67| 7,01| /| /| /

55

| -25| /| /| /| /| /| /| /| /| /| /| /| /
-20| 2615| 2516| 2213| 1909| /| /| 1,25| 1,25| 1,26| 1,27| /| /
-15| 4937| 4552| 3955| 3357| /| /| 1,69| 1,72| 1,74| 1,75| /| /
-10| 6066| 5533| 4866| 4198| /| /| 1,99| 2,01| 2,03| 2,05| /| /
-7| 6222| 6150| 5748| 3571| /| /| 2,03| 2,05| 2,17| 2,13| /| /
-5| 6447| 6057| 4853| 3649| /| /| 2,19| 2,23| 2,27| 2,30| /| /
-2| 6772| 6194| 4960| 3726| /| /| 2,28| 2,32| 2,35| 2,38| /| /
0| 7097| 6330| 5067| 3804| /| /| 2,38| 2,41| 2,44| 2,47| /| /
2| 7256| 7100| 6605| 4009| /| /| 2,56| 2,60| 2,75| 2,66| /| /
5| 7562| 6684| 5482| 4280| /| /| 2,76| 2,82| 2,87| 2,91| /| /
7| 7802| 7500| 6227| 4954| /| /| 3,12| 3,18| 3,26| 3,33| /| /
10| 8198| 7139| 6156| 5173| /| /| 3,31| 3,38| 3,45| 3,51| /| /
12| 8245| 7213| 6356| 5499| /| /| 3,41| 3,50| 3,58| 3,65| /| /
15| 8316| 7325| 6657| 5988| /| /| 3,55| 3,68| 3,77| 3,86| /| /
20| 8434| 7471| 6561| 5651| /| /| 3,97| 4,14| 4,25| 4,35| /| /
25| 8089| 7307| 6558| 5808| /| /| 4,25| 4,47| 4,58| 4,69| /| /
30| 7844| 7125| 6477| 5828| /| /| 4,53| 4,80| 4,92| 5,04| /| /
35| 8158| 7476| 6363| /| /| /| 4,72| 5,03| 5,29| /| /| /
40| /| /| /| /| /| /| /| /| /| /| /| /
43| /| /| /| /| /| /| /| /| /| /| /| /

60

| -25| /| /| /| /| /| /| /| /| /| /| /| /
-20| /| /| /| /| /| /| /| /| /| /| /| /
-15| 3994| 3718| 3277| 2836| /| /| 1,41| 1,41| 1,42| 1,43| /| /
-10| 5187| 4777| 4251| 3724| /| /| 1,81| 1,81| 1,83| 1,84| /| /
-7| 5320| 5065| 4240| 3415| /| /| 1,85| 1,89| 1,91| 1,92| /| /
-5| 6040| 5481| 4595| 3708| /| /| 2,02| 2,04| 2,07| 2,09| /| /
-2| 6444| 5757| 4821| 3885| /| /| 2,09| 2,10| 2,13| 2,16| /| /
0| 6849| 6034| 5048| 4061| /| /| 2,17| 2,17| 2,20| 2,22| /| /
2| 6910| 6159| 5186| 4212| /| /| 2,20| 2,25| 2,30| 2,34| /| /
5| 7110| 6207| 5319| 4430| /| /| 2,46| 2,49| 2,53| 2,56| /| /
7| 7241| 6249| 5507| 4765| /| /| 2,72| 2,77| 2,82| 2,87| /| /
10| 7499| 6893| 5959| 5024| /| /| 2,76| 2,81| 2,87| 2,92| /| /
12| 7571| 6989| 6123| 5256| /| /| 2,89| 2,96| 3,01| 3,04| /| /
15| 7678| 7134| 6370| 5605| /| /| 3,09| 3,19| 3,21| 3,23| /| /
20| 7857| 7340| 6302| 5264| /| /| 3,46| 3,47| 3,56| 3,65| /| /
25| 7465| 7104| 6277| 5449| /| /| 3,72| 3,76| 3,86| 3,96| /| /
30| 7072| 6766| 6053| 5339| /| /| 3,98| 4,06| 4,17| 4,27| /| /
35| /| /| /| /| /| /| /| /| /| /| /| /
40| /| /| /| /| /| /| /| /| /| /| /| /
43| /| /| /| /| /| /| /| /| /| /| /| /

65

| -25| /| /| /| /| /| /| /| /| /| /| /| /
-20| /| /| /| /| /| /| /| /| /| /| /| /
-15| /| /| /| /| /| /| /| /| /| /| /| /
-10| /| /| /| /| /| /| /| /| /| /| /| /
-7| /| /| /| /| /| /| /| /| /| /| /| /
-5| /| /| /| /| /| /| /| /| /| /| /| /
-2| /| /| /| /| /| /| /| /| /| /| /| /
0| /| /| /| /| /| /| /| /| /| /| /| /
2| /| /| /| /| /| /| /| /| /| /| /| /
5| 3887| 3316| 2892| 2468| /| /| 1,19| 1,22| 1,23| 1,24| /| /
7| 4082| 3441| 3064| 2686| /| /| 1,36| 1,40| 1,41| 1,42| /| /
10| 5591| 4920| 4361| 3802| /| /| 2,11| 2,16| 2,19| 2,22| /| /
12| 5638| 5030| 4420| 3811| /| /| 2,22| 2,28| 2,31| 2,34| /| /
15| 5708| 5194| 4509| 3824| /| /| 2,39| 2,46| 2,49| 2,52| /| /
20| /| /| /| /| /| /| /| /| /| /| /| /
25| /| /| /| /| /| /| /| /| /| /| /| /
30| /| /| /| /| /| /| /| /| /| /| /| /
35| /| /| /| /| /| /| /| /| /| /| /| /
40| /| /| /| /| /| /| /| /| /| /| /| /
43| /| /| /| /| /| /| /| /| /| /| /| /
“Tw_out

°C”

| “DB/WB

°C”

| Heating Capacity [W]| COP
---|---|---|---
130%| 100%| 90%| 70%| 50%| 30%| 130%| 100%| 90%| 70%| 50%| 30%

25

| -25| 4680| 4329| 3569| 2808| /| /| 2,27| 2,32| 2,34| 2,35| /| /
-20| 5982| 5473| 4412| 3350| /| /| 2,82| 2,93| 2,96| 2,99| /| /
-15| 7263| 6573| 6027| 5481| 3392| /| 3,37| 3,53| 3,73| 3,93| 3,61| /
-10| 8372| 7493| 6451| 5409| 4366| 3324| 3,60| 3,81| 3,84| 3,86| 3,89| 3,91
-7| 8721| 8285| 6737| 5189| 3641| 2093| 3,81| 3,92| 3,98| 4,03| 4,09| 4,14
-5| 8997| 8126| 6693| 5260| 3826| 2393| 4,10| 4,29| 4,34| 4,39| 4,43| 4,48
-2| 9215| 8227| 6772| 5317| 3862| 2407| 4,50| 4,68| 4,73| 4,77| 4,82| 4,86
0| 9433| 8328| 6851| 5375| 3898| 2421| 4,90| 5,06| 5,11| 5,15| 5,20| 5,24
2| 9719| 8621| 7170| 5720| 4269| 2818| 5,18| 5,34| 5,41| 5,47| 5,54| 5,60
5| 10242| 9087| 7631| 6174| 4718| 3261| 5,72| 5,95| 6,01| 6,07| 6,12| 6,18
7| 10494| 10220| 8604| 6989| 5373| 3757| 5,94| 6,05| 6,16| 6,27| 6,37| 6,48
10| 11196| 10063| 8404| 6745| 5085| 3426| 7,04| 7,50| 7,59| 7,68| 7,77| 7,86
12| 11286| 10189| 8604| 7018| 5432| 3846| 7,46| 8,03| 8,13| 8,24| 8,34| 8,44
15| 11420| 10379| 8904| 7428| 5953| 4477| 8,10| 8,83| 8,95| 9,08| 9,20| 9,32
20| 10808| 9876| 8992| 8107| 4864| /| 9,05| 9,94| 10,59| 11,25| 10,51| /
25| 9943| 8863| 7166| 5469| /| /| 9,59| 10,61| 10,92| 11,22| /| /
30| 9774| 8761| 7191| 5620| /| /| 10,15| 11,31| 11,64| 11,96| /| /
35| 10165| 9192| 8002| 6811| /| /| 10,73| 12,03| 12,38| 12,73| /| /
40| 10673| 9791| 8525| 7258| /| /| 11,52| 13,01| 13,39| 13,76| /| /
43| 10993| 10172| 8879| 7585| /| /| 12,03| 13,67| 14,07| 14,47| /| /

30

| -25| 4210| 3873| 3244| 2614| /| /| 1,98| 2,05| 2,07| 2,08| /| /
-20| 5354| 4873| 4572| 4270| 2891| /| 2,39| 2,46| 2,59| 2,73| 2,50| /
-15| 6782| 6104| 5635| 5166| 3289| /| 2,90| 3,01| 3,18| 3,35| 3,08| /
-10| 8144| 7248| 6230| 5212| 4194| 3176| 3,22| 3,37| 3,40| 3,42| 3,45| 3,47
-7| 8483| 8182| 6624| 5067| 3509| 1951| 3,41| 3,51| 3,54| 3,58| 3,61| 3,64
-5| 8862| 8205| 6734| 5264| 3793| 2322| 3,60| 3,70| 3,74| 3,77| 3,81| 3,84
-2| 9109| 8230| 6797| 5365| 3932| 2499| 3,82| 3,93| 3,97| 4,00| 4,04| 4,07
0| 9357| 8254| 6860| 5465| 4071| 2676| 4,05| 4,15| 4,19| 4,23| 4,26| 4,30
2| 9568| 8677| 7268| 5858| 4449| 3039| 4,34| 4,52| 4,56| 4,61| 4,65| 4,69
5| 10072| 9005| 7616| 6228| 4839| 3450| 4,80| 4,99| 5,04| 5,09| 5,13| 5,18
7| 10275| 9983| 8453| 6923| 5393| 3863| 5,21| 5,40| 5,47| 5,55| 5,62| 5,69
10| 10414| 9116| 7600| 6084| 4567| 3051| 5,64| 5,91| 5,98| 6,05| 6,12| 6,19
12| 10497| 9232| 7799| 6366| 4933| 3501| 5,98| 6,33| 6,41| 6,49| 6,57| 6,65
15| 10622| 9405| 8098| 6790| 5483| 4175| 6,49| 6,96| 7,06| 7,16| 7,25| 7,35
20| 10756| 9577| 8871| 8166| 5270| /| 7,96| 8,60| 9,17| 9,74| 9,10| /
25| 9896| 8984| 7411| 5838| /| /| 8,44| 9,18| 9,45| 9,72| /| /
30| 9073| 8282| 6931| 5580| /| /| 8,79| 9,63| 9,92| 10,20| /| /
35| 9436| 8689| 7553| 6416| /| /| 9,15| 10,10| 10,40| 10,69| /| /
40| 9908| 8966| 7802| 6638| /| /| 9,81| 10,90| 11,22| 11,54| /| /
43| 10205| 9317| 8128| 6939| /| /| 10,61| 11,87| 12,22| 12,57| /| /

35

| -25| 3778| 3446| 3027| 2607| /| /| 1,66| 1,68| 1,70| 1,71| /| /
-20| 4985| 4496| 3694| 2891| /| /| 2,13| 2,20| 2,22| 2,24| /| /
-15| 6427| 5733| 5284| 4836| 3059| /| 2,46| 2,56| 2,70| 2,85| 2,62| /
-10| 7885| 6955| 5995| 5035| 4075| 3115| 2,98| 3,08| 3,10| 3,13| 3,15| 3,17
-7| 8314| 8| 2054| /| /| /| 3,11| 3,05| 3,37| /| /| /
-5| 8799| 8164| 6743| 5323| 3902| 2481| 3,33| 3,41| 3,45| 3,49| 3,53| 3,57
-2| 9131| 8249| 6831| 5412| 3994| 2575| 3,54| 3,64| 3,68| 3,71| 3,75| 3,78
0| 9463| 8335| 6918| 5502| 4085| 2668| 3,76| 3,86| 3,89| 3,93| 3,96| 3,99
2| 9719| 8200| 6907| 5614| 4320| 3027| 3,97| 4,00| 4,09| 4,17| 4,26| 4,34
5| 10132| 9068| 7660| 6252| 4843| 3435| 4,51| 4,68| 4,73| 4,77| 4,82| 4,86
**7 *| 10322| 10000| 8452| 6905| 5357| 3809| 4,93| 4,95**| 5,06| 5,17| 5,28| 5,39
10| 10031| 8855| 7434| 6013| 4591| 3170| 5,13| 5,28| 5,35| 5,41| 5,48| 5,54
12| 10111| 8967| 7601| 6235| 4868| 3502| 5,44| 5,66| 5,73| 5,81| 5,88| 5,96
15| 10232| 9134| 7851| 6568| 5284| 4001| 5,90| 6,22| 6,31| 6,40| 6,49| 6,58
20| 10673| 9582| 8982| 8381| 5657| /| 6,72| 7,14| 7,61| 8,09| 7,56| /
25| 9819| 8987| 7587| 6186| /| /| 7,12| 7,63| 7,85| 8,07| /| /
30| 8895| 8186| 7006| 5826| /| /| 7,95| 8,57| 8,83| 9,08| /| /
35| 9251| 8587| 7328| 6069| /| /| 8,30| 9,01| 9,28| 9,55| /| /
40| 9713| 8754| 7825| 6896| /| /| 8,47| 9,26| 9,54| 9,81| /| /
43| 10005| 9097| 8150| 7203| /| /| 9,25| 10,18| 10,49| 10,79| /| /

40

| -25| 3520| 3260| 2880| 2499| /| /| 1,57| 1,57| 1,59| 1,60| /| /
-20| 4548| 4166| 3538| 2910| /| /| 1,79| 1,82| 1,84| 1,85| /| /
-15| 5859| 5308| 4295| 3281| /| /| 2,28| 2,34| 2,37| 2,40| /| /
-10| 7638| 6843| 6396| 5948| 3972| /| 2,67| 2,74| 2,90| 3,06| 2,82| /
-7| 7956| 7430| 6725| 6021| 3517| /| 2,83| 2,93| 3,12| 3,31| 3,08| /
-5| 8460| 7560| 6869| 6177| 3671| /| 2,88| 2,96| 3,15| 3,35| 3,13| /
-2| 8857| 7896| 7173| 6449| 3830| /| 3,02| 3,08| 3,27| 3,47| 3,22| /
0| 9254| 8232| 7477| 6721| 3988| /| 3,16| 3,20| 3,39| 3,58| 3,31| /
2| 9578| 8791| 7992| 7193| 4287| /| 3,35| 3,46| 3,68| 3,89| 3,62| /
5| 10096| 9228| 8432| 7635| 4654| /| 3,83| 3,92| 4,16| 4,39| 4,07| /
7| 10448| 10145| 9216| 8286| 4921| /| 4,18| 4,29| 4,57| 4,85| 4,53| /
10| 9935| 8878| 8110| 7342| 4471| /| 4,17| 4,35| 4,62| 4,90| 4,55| /
12| 10015| 8990| 8221| 7452| 4559| /| 4,42| 4,66| 4,95| 5,26| 4,89| /
15| 10134| 9157| 8387| 7617| 4692| /| 4,80| 5,12| 5,45| 5,79| 5,40| /
20| 10679| 9703| 8216| 6728| /| /| 5,66| 6,08| 6,26| 6,44| /| /
25| 9825| 9099| 8136| 7172| /| /| 6,00| 6,49| 6,68| 6,87| /| /
30| 8852| 8242| 7153| 6064| /| /| 6,72| 7,32| 7,54| 7,75| /| /
35| 9206| 8645| 7499| 6352| /| /| 6,97| 7,65| 7,88| 8,10| /| /
40| 9666| 8817| 7889| 6960| /| /| 7,34| 8,11| 8,35| 8,59| /| /
43| 9956| 9161| 8215| 7268| /| /| 8,07| 8,98| 9,25| 9,51| /| /

45

| -25| 2963| 2776| 2322| 1867| /| /| 1,31| 1,30| 1,31| 1,31| /| /
-20| 3892| 3608| 3011| 2413| /| /| 1,63| 1,64| 1,65| 1,66| /| /
-15| 5566| 4937| 4250| 3562| /| /| 2,02| 2,05| 2,07| 2,08| /| /
-10| 7376| 6690| 5580| 4470| /| /| 2,38| 2,41| 2,44| 2,46| /| /
-7| 7683| 7350| 6734| 6117| 3772| /| 2,52| 2,55| 2,71| 2,87| 2,67| /
-5| 8181| 7433| 6847| 6261| 3951| /| 2,65| 2,72| 2,88| 3,04| 2,80| /
-2| 8535| 7650| 7011| 6372| 3936| /| 2,76| 2,84| 3,00| 3,17| 2,92| /
0| 8889| 7866| 7174| 6482| 3920| /| 2,87| 2,97| 3,14| 3,31| 3,04| /
2| 9244| 7850| 7247| 6644| 4230| /| 3,01| 3,20| 3,38| 3,56| 3,28| /
5| 9786| 8582| 7919| 7255| 4609| /| 3,40| 3,55| 3,76| 3,97| 3,66| /
7| 10279| 10000| 9277| 8553| 5551| /| 3,77| 3,75| 4,03| 4,31| 4,09| /
10| 9873| 8937| 8395| 7853| 5341| /| 3,67| 3,72| 3,94| 4,17| 3,86| /
12| 9952| 9049| 7996| 6943| /| /| 3,89| 3,98| 4,16| 4,34| /| /
15| 10070| 9216| 7398| 5579| /| /| 4,22| 4,38| 4,49| 4,59| /| /
20| 10283| 9462| 7919| 6375| /| /| 4,86| 5,08| 5,21| 5,34| /| /
25| 9460| 8871| 7841| 6811| /| /| 5,15| 5,43| 5,57| 5,70| /| /
30| 9923| 9354| 8324| 7293| /| /| 6,15| 6,53| 6,70| 6,86| /| /
35| 10320| 9811| 8724| 7637| /| /| 6,40| 6,84| 7,02| 7,19| /| /
40| 10836| 10009| 9122| 8235| /| /| 6,79| 7,31| 7,50| 7,68| /| /
43| 11161| 10398| 9552| 8706| /| /| 7,58| 8,21| 8,43| 8,64| /| /
“Tw_out

°C”

| “DB/WB

°C”

| Heating Capacity [W]| COP
---|---|---|---
130%| 100%| 90%| 70%| 50%| 30%| 130%| 100%| 90%| 70%| 50%| 30%

50

| -25| /| /| /| /| /| /| /| /| /| /| /| /
-20| 3342| 3111| 2709| 2306| /| /| 1,42| 1,44| 1,45| 1,45| /| /
-15| 5215| 4779| 4085| 3391| /| /| 1,74| 1,78| 1,80| 1,81| /| /
-10| 7033| 6407| 5591| 4775| /| /| 2,13| 2,16| 2,18| 2,20| /| /
-7| 7326| 6998| 6475| 5952| 3824| /| 2,25| 2,30| 2,43| 2,56| 2,36| /
-5| 8039| 7081| 6624| 6167| 4132| /| 2,46| 2,52| 2,66| 2,81| 2,58| /
-2| 8428| 7557| 7041| 6524| 4305| /| 2,58| 2,63| 2,78| 2,93| 2,70| /
0| 8817| 8032| 7457| 6881| 4479| /| 2,70| 2,75| 2,91| 3,06| 2,82| /
2| 9016| 8201| 7660| 7120| 4744| /| 2,80| 2,89| 3,06| 3,24| 3,00| /
5| 9452| 8535| 8013| 7491| 5085| /| 3,01| 3,09| 3,27| 3,45| 3,18| /
7| 9833| 9581| 7839| 6096| /| /| 3,22| 3,28| 3,37| 3,46| /| /
10| 9588| 8860| 7321| 5782| /| /| 3,30| 3,39| 3,46| 3,52| /| /
12| 9665| 8970| 7427| 5883| /| /| 3,50| 3,63| 3,71| 3,78| /| /
15| 9780| 9135| 7585| 6034| /| /| 3,80| 3,99| 4,09| 4,18| /| /
20| 10022| 9412| 7963| 6514| /| /| 4,21| 4,46| 4,57| 4,68| /| /
25| 9220| 8820| 7868| 6915| /| /| 4,46| 4,76| 4,88| 5,00| /| /
30| 9314| 8956| 8087| 7218| /| /| 4,96| 5,33| 5,46| 5,59| /| /
35| 9687| 9392| 8571| 7749| /| /| 5,17| 5,59| 5,74| 5,88| /| /
40| 10171| 9587| 8238| /| /| /| 5,53| 6,02| 6,33| /| /| /
43| 10476| 9959| 8695| /| /| /| 6,25| 6,85| 7,20| /| /| /

55

| -25| /| /| /| /| /| /| /| /| /| /| /| /
-20| 2753| 2648| 2329| 2010| /| /| 1,26| 1,27| 1,28| 1,28| /| /
-15| 5197| 4692| 4113| 3534| /| /| 1,71| 1,74| 1,75| 1,76| /| /
-10| 6670| 6083| 5350| 4616| /| /| 1,86| 1,88| 1,90| 1,92| /| /
-7| 7048| 6850| 6405| 5961| 3988| /| 1,97| 2,00| 2,12| 2,24| 2,07| /
-5| 7528| 6889| 5575| 4261| /| /| 2,27| 2,31| 2,35| 2,38| /| /
-2| 7853| 7092| 5707| 4322| /| /| 2,37| 2,43| 2,46| 2,49| /| /
0| 8179| 7295| 5840| 4384| /| /| 2,47| 2,54| 2,58| 2,61| /| /
2| 8515| 8100| 7576| 7052| 4722| /| 2,52| 2,56| 2,73| 2,90| 2,71| /
5| 9075| 8023| 6580| 5137| /| /| 2,78| 2,84| 2,88| 2,92| /| /
7| 9721| 9500| 7837| 6173| /| /| 3,04| 3,10| 3,18| 3,25| /| /
10| 9573| 8337| 7189| 6041| /| /| 3,08| 3,14| 3,21| 3,27| /| /
12| 9649| 8443| 7440| 6437| /| /| 3,26| 3,35| 3,43| 3,50| /| /
15| 9764| 8601| 7816| 7030| /| /| 3,54| 3,67| 3,76| 3,85| /| /
20| 9851| 8727| 7664| 6600| /| /| 3,88| 4,05| 4,15| 4,25| /| /
25| 9063| 8187| 7347| 6507| /| /| 4,11| 4,32| 4,43| 4,54| /| /
30| 9037| 8209| 7462| 6714| /| /| 4,80| 5,08| 5,21| 5,34| /| /
35| 9416| 8628| 7345| /| /| /| 4,96| 5,29| 5,56| /| /| /
40| /| /| /| /| /| /| /| /| /| /| /| /
43| /| /| /| /| /| /| /| /| /| /| /| /

60

| -25| /| /| /| /| /| /| /| /| /| /| /| /
-20| /| /| /| /| /| /| /| /| /| /| /| /
-15| 4204| 3914| 3450| 2985| /| /| 1,42| 1,42| 1,43| 1,44| /| /
-10| 5385| 4959| 4413| 3866| /| /| 1,71| 1,70| 1,72| 1,74| /| /
-7| 5609| 5142| 4372| 3601| /| /| 1,81| 1,84| 1,86| 1,88| /| /
-5| 6131| 5463| 4614| 3764| /| /| 1,98| 2,02| 2,04| 2,06| /| /
-2| 6560| 5810| 4882| 3954| /| /| 2,05| 2,07| 2,09| 2,11| /| /
0| 6989| 6157| 5151| 4144| /| /| 2,12| 2,11| 2,14| 2,17| /| /
2| 7324| 6941| 5712| 4482| /| /| 2,19| 2,23| 2,27| 2,31| /| /
5| 7853| 6856| 5875| 4893| /| /| 2,45| 2,48| 2,52| 2,55| /| /
7| 8227| 7700| 6557| 5413| /| /| 2,78| 2,83| 2,88| 2,93| /| /
10| 8268| 7600| 6570| 5540| /| /| 2,72| 2,77| 2,83| 2,88| /| /
12| 8334| 7694| 6740| 5786| /| /| 2,88| 2,95| 3,00| 3,04| /| /
15| 8433| 7836| 6996| 6156| /| /| 3,13| 3,23| 3,25| 3,27| /| /
20| 8895| 8309| 7135| 5960| /| /| 3,48| 3,49| 3,58| 3,67| /| /
25| 8183| 7788| 6881| 5974| /| /| 3,69| 3,73| 3,83| 3,93| /| /
30| 7490| 7165| 6410| 5655| /| /| 3,83| 3,90| 4,01| 4,11| /| /
35| /| /| /| /| /| /| /| /| /| /| /| /
40| /| /| /| /| /| /| /| /| /| /| /| /
43| /| /| /| /| /| /| /| /| /| /| /| /

65

| -25| /| /| /| /| /| /| /| /| /| /| /| /
-20| /| /| /| /| /| /| /| /| /| /| /| /
-15| /| /| /| /| /| /| /| /| /| /| /| /
-10| /| /| /| /| /| /| /| /| /| /| /| /
-7| /| /| /| /| /| /| /| /| /| /| /| /
-5| /| /| /| /| /| /| /| /| /| /| /| /
-2| /| /| /| /| /| /| /| /| /| /| /| /
0| /| /| /| /| /| /| /| /| /| /| /| /
2| /| /| /| /| /| /| /| /| /| /| /| /
5| 4523| 3858| 3365| 2872| /| /| 1,37| 1,40| 1,41| 1,42| /| /
7| 4847| 4286| 3738| 3189| /| /| 1,56| 1,61| 1,62| 1,63| /| /
10| 6436| 5664| 5020| 4376| /| /| 2,11| 2,16| 2,19| 2,22| /| /
12| 6488| 5788| 5086| 4385| /| /| 2,24| 2,30| 2,33| 2,36| /| /
15| 6565| 5974| 5186| 4398| /| /| 2,43| 2,50| 2,53| 2,56| /| /
20| /| /| /| /| /| /| /| /| /| /| /| /
25| /| /| /| /| /| /| /| /| /| /| /| /
30| /| /| /| /| /| /| /| /| /| /| /| /
35| /| /| /| /| /| /| /| /| /| /| /| /
40| /| /| /| /| /| /| /| /| /| /| /| /
43| /| /| /| /| /| /| /| /| /| /| /| /

IDOLA S 3.2 HYBRID 28H 4 – Prestazioni raffreddamento / Cooling capacity

“Tw_out

°C”

| “DB/WB

°C”

| Cooling Capacity [W]| EER
---|---|---|---
130%| 100%| 90%| 70%| 50%| 30%| 130%| 100%| 90%| 70%| 50%| 30%

5

| -5| /| /| /| /| /| /| /| /| /| /| /| /
0| /| /| /| /| /| /| /| /| /| /| /| /
5| /| /| /| /| /| /| /| /| /| /| /| /
10| /| /| /| /| /| /| /| /| /| /| /| /
15| /| /| /| /| /| /| /| /| /| /| /| /
20| 4715| 3676| 3360| 3044| 1858| /| 4,53| 4,76| 5,05| 5,34| 4,95| /
25| 5872| 4651| 4218| 3785| 2231| /| 4,51| 4,78| 5,05| 5,32| 4,89| /
30| 5836| 4693| 4250| 3807| 2229| /| 3,78| 4,02| 4,24| 4,47| 4,10| /
35| 5799| 4506| 4057| 3607| 2053| /| 3,24| 3,32| 3,54| 3,75| 3,50| /
40| 3803| 3105| 2792| 2479| 1402| /| 2,52| 2,70| 2,83| 2,96| 2,69| /
43| 2582| 2120| 1772| 1423| 1075| 726| 2,24| 2,33| 2,34| 2,36| 2,37| 2,38

7

| -5| /| /| /| /| /| /| /| /| /| /| /| /
0| /| /| /| /| /| /| /| /| /| /| /| /
5| /| /| /| /| /| /| /| /| /| /| /| /
10| /| /| /| /| /| /| /| /| /| /| /| /
15| /| /| /| /| /| /| /| /| /| /| /| /
20| 5265| 4096| 3706| 3316| 1933| /| 4,73| 4,95| 5,27| 5,58| 5,20| /
25| 6304| 4978| 4291| 3605| 2231| /| 4,65| 4,88| 4,92| 4,95| 5,02| /
30| 6206| 4974| 4283| 3592| 2210| /| 3,99| 4,20| 4,24| 4,28| 4,35| /
35| 6107| 4700| 4254| 3807| 2222| /| 3,32| 3,45| 3,72| 3,99| 3,80| /
40| 4363| 3552| 3208| 2864| 1655| /| 2,64| 2,81| 2,96| 3,12| 2,86| /
43| 3134| 2451| 2100| 1748| 1045| /| 2,35| 2,41| 2,43| 2,45| 2,49| /

10

| -5| /| /| /| /| /| /| /| /| /| /| /| /
0| /| /| /| /| /| /| /| /| /| /| /| /
5| /| /| /| /| /| /| /| /| /| /| /| /
10| /| /| /| /| /| /| /| /| /| /| /| /
15| 5049| 3787| 3055| 2323| /| /| 5,91| 6,25| 6,45| 6,64| /| /
20| 6009| 4858| 4175| 3493| 2810| 2127| 4,47| 4,80| 4,85| 4,90| 4,95| 5,00
25| 6968| 5721| 4883| 4045| 3207| 2369| 3,80| 4,09| 4,14| 4,19| 4,24| 4,29
30| 6803| 5669| 4834| 3998| 3163| 2327| 3,67| 3,92| 3,97| 4,02| 4,06| 4,11
35| 6638| 5450| 4919| 4388| 2529| /| 3,55| 3,82| 4,06| 4,30| 4,00| /
40| 5082| 4296| 3882| 3469| 2011| /| 2,81| 3,03| 3,21| 3,38| 3,12| /
43| 3800| 2987| 2708| 2429| 1429| /| 2,51| 2,59| 2,74| 2,90| 2,68| /

15

| -5| 4759| 3832| 3156| 2479| /| /| 10,30| 11,74| 12,17| 12,60| /| /
0| 4538| 3660| 3018| 2375| /| /| 8,03| 9,35| 9,64| 9,92| /| /
5| 4038| 3235| 2986| 2736| 1740| /| 6,07| 6,68| 7,20| 7,72| 7,35| /
10| 6063| 4872| 4519| 4165| 2701| /| 5,71| 6,29| 6,80| 7,30| 6,99| /
15| 8088| 6794| 6266| 5739| 3640| /| 5,55| 5,89| 6,29| 6,70| 6,29| /
20| 8159| 6801| 6200| 5598| 3378| /| 5,47| 5,88| 6,27| 6,66| 6,23| /
25| 8230| 6963| 6302| 5640| 3292| /| 5,39| 5,74| 6,11| 6,48| 6,04| /
30| 7771| 6669| 6028| 5386| 3124| /| 4,72| 5,06| 5,38| 5,70| 5,30| /
35| 7311| 6024| 5497| 4970| 3012| /| 4,28| 4,63| 4,94| 5,25| 4,91| /
40| 5914| 5147| 4683| 4219| 2523| /| 3,41| 3,68| 3,90| 4,13| 3,82| /
43| 5075| 4040| 3712| 3383| 2111| /| 3,26| 3,43| 3,64| 3,85| 3,57| /

18

| -5| 5185| 4182| 3437| 2691| /| /| 10,32| 11,97| 12,28| 12,59| /| /
0| 4961| 4008| 3297| 2586| /| /| 8,19| 9,70| 9,90| 10,09| /| /
5| 4454| 3557| 3283| 3009| 1914| /| 6,30| 7,07| 7,57| 8,08| 7,62| /
10| 6341| 5079| 4710| 4342| 2815| /| 6,15| 6,91| 7,42| 7,93| 7,51| /
15| 8130| 6911| 6340| 5768| 3577| /| 6,10| 6,56| 7,04| 7,51| 7,10| /
20| 8278| 7013| 6447| 5880| 3678| /| 6,05| 6,50| 6,92| 7,33| 6,83| /
25| 8410| 7274| 6635| 5996| 3628| /| 6,00| 6,45| 6,85| 7,25| 6,74| /
30| 8094| 7032| 6406| 5779| 3476| /| 5,27| 5,63| 5,98| 6,34| 5,89| /
**35 *| 7649| 4500| 3928| 3355| /| /| 4,73| 5,50**| 5,59| 5,62| /| /
40| 6358| 5602| 5130| 4659| 2868| /| 3,75| 4,07| 4,31| 4,54| 4,19| /
43| 5556| 4584| 4199| 3815| 2352| /| 3,56| 3,79| 4,01| 4,23| 3,90| /

20

| -5| 5468| 4450| 3661| 2871| /| /| 10,01| 11,92| 12,15| 12,38| /| /
0| 5247| 4277| 3522| 2767| /| /| 8,08| 9,81| 9,95| 10,09| /| /
5| 4747| 3809| 3520| 3231| 2065| /| 6,34| 7,29| 7,78| 8,28| 7,76| /
10| 6443| 5185| 4815| 4445| 2896| /| 6,40| 7,37| 7,89| 8,40| 7,91| /
15| 8139| 7000| 6388| 5775| 3500| /| 6,44| 7,06| 7,62| 8,17| 7,80| /
20| 8331| 7170| 6643| 6115| 3949| /| 6,42| 6,94| 7,39| 7,84| 7,32| /
25| 8523| 7441| 6845| 6249| 3921| /| 6,40| 6,98| 7,43| 7,87| 7,33| /
30| 8195| 7255| 6664| 6073| 3786| /| 5,63| 6,05| 6,44| 6,84| 6,38| /
35| 7866| 6867| 6328| 5789| 3658| /| 5,06| 5,48| 5,88| 6,27| 5,92| /
40| 6627| 5947| 5483| 5019| 3179| /| 3,95| 4,34| 4,60| 4,86| 4,50| /
43| 5884| 5037| 4609| 4181| 2565| /| 3,74| 4,04| 4,28| 4,52| 4,17| /

25

| -5| 6094| 4951| 4082| 3212| /| /| 12,66| 14,10| 14,97| 15,83| /| /
0| 5873| 4779| 3944| 3109| /| /| 10,70| 13,31| 13,36| 13,40| /| /
5| 5373| 4360| 4025| 3689| 2348| /| 8,28| 9,77| 10,37| 10,97| 10,17| /
10| 7113| 5789| 5370| 4951| 3212| /| 8,37| 9,89| 10,52| 11,15| 10,39| /
15| 8853| 7437| 6932| 6427| 4249| /| 8,43| 9,29| 10,04| 10,79| 10,32| /
20| 8984| 7821| 7282| 6742| 4438| /| 8,15| 8,98| 9,57| 10,16| 9,50| /
25| 9115| 8049| 7441| 6833| 4375| /| 7,90| 8,85| 9,41| 9,97| 9,28| /
30| 8773| 7854| 7250| 6645| 4228| /| 6,75| 7,44| 7,89| 8,34| 7,72| /
35| 8430| 7688| 7122| 6556| 4232| /| 5,84| 6,39| 6,83| 7,28| 6,84| /
40| 7878| 7147| 6658| 6169| 4070| /| 4,80| 5,41| 5,71| 6,01| 5,51| /
43| 7546| 5969| 4886| 3803| /| /| 4,73| 5,18| 5,28| 5,38| /| /

IDOLA S 3.2 HYBRID 28H 6 – Prestazioni raffreddamento / Cooling capacity

“Tw_out

°C”

| “DB/WB

°C”

| Cooling Capacity [W]| EER
---|---|---|---
130%| 100%| 90%| 70%| 50%| 30%| 130%| 100%| 90%| 70%| 50%| 30%

5

| -5| /| /| /| /| /| /| /| /| /| /| /| /
0| /| /| /| /| /| /| /| /| /| /| /| /
5| /| /| /| /| /| /| /| /| /| /| /| /
10| /| /| /| /| /| /| /| /| /| /| /| /
15| /| /| /| /| /| /| /| /| /| /| /| /
20| 5411| 4218| 3855| 3493| 2132| /| 3,93| 4,14| 4,39| 4,64| 4,30| /
25| 7164| 5674| 5146| 4618| 2722| /| 3,98| 4,21| 4,45| 4,69| 4,31| /
30| 6502| 5229| 4736| 4242| 2484| /| 3,51| 3,74| 3,95| 4,15| 3,81| /
35| 6039| 4737| 4070| 3402| 2735| 2067| 3,06| 3,22| 3,24| 3,27| 3,29| 3,31
40| 3803| 3105| 2792| 2479| 1402| 988| 2,52| 2,70| 2,83| 2,96| 2,69| 2,55
43| 2582| 2120| 1772| 1423| 1075| 726| 2,24| 2,33| 2,34| 2,36| 2,37| 2,38

7

| -5| /| /| /| /| /| /| /| /| /| /| /| /
0| /| /| /| /| /| /| /| /| /| /| /| /
5| /| /| /| /| /| /| /| /| /| /| /| /
10| /| /| /| /| /| /| /| /| /| /| /| /
15| /| /| /| /| /| /| /| /| /| /| /| /
20| 6103| 4836| 4366| 3896| 2248| /| 4,27| 4,54| 4,82| 5,09| 4,72| /
25| 7265| 5919| 5063| 4206| 3350| 2493| 4,07| 4,34| 4,38| 4,42| 4,46| 4,50
30| 7145| 5822| 4989| 4156| 3322| 2489| 3,67| 3,91| 3,95| 3,98| 4,02| 4,05
35| 7108| 6500| 5860| 4719| 3579| 2438| 2,97| 3,00| 3,16| 3,33| 3,49| 3,65
40| 4505| 3737| 3371| 3005| 1727| 1344| 2,66| 2,86| 3,01| 3,17| 2,90| 3,20
43| 3236| 2579| 2207| 1835| 1462| 1090| 2,37| 2,46| 2,48| 2,49| 2,51| 2,52

10

| -5| /| /| /| /| /| /| /| /| /| /| /| /
0| /| /| /| /| /| /| /| /| /| /| /| /
5| /| /| /| /| /| /| /| /| /| /| /| /
10| /| /| /| /| /| /| /| /| /| /| /| /
15| 5887| 4415| 3562| 2708| /| /| 5,33| 5,65| 5,82| 5,99| /| /
20| 6626| 5358| 4605| 3852| 3099| 2346| 4,62| 4,96| 5,01| 5,07| 5,12| 5,17
25| 7365| 6047| 5161| 4276| 3390| 2504| 4,17| 4,49| 4,55| 4,61| 4,66| 4,72
30| 7292| 6076| 5181| 4285| 3390| 2494| 3,84| 4,10| 4,15| 4,20| 4,25| 4,30
35| 7219| 5927| 5350| 4772| 2750| /| 3,55| 3,83| 4,07| 4,31| 4,00| /
40| 5082| 4296| 3882| 3469| 2011| /| 2,81| 3,03| 3,21| 3,38| 3,12| /
43| 3800| 2987| 2708| 2429| 1429| /| 2,51| 2,59| 2,74| 2,90| 2,68| /

15

| -5| 5269| 4243| 3494| 2745| /| /| 8,93| 10,18| 10,55| 10,92| /| /
0| 5048| 4072| 3357| 2642| /| /| 7,28| 8,48| 8,74| 9,00| /| /
5| 4548| 3643| 3362| 3082| 1960| /| 5,74| 6,31| 6,80| 7,29| 6,95| /
10| 6318| 5077| 4709| 4341| 2815| /| 5,61| 6,18| 6,68| 7,18| 6,87| /
15| 8088| 6794| 6266| 5739| 3640| /| 5,55| 5,89| 6,29| 6,70| 6,29| /
20| 8159| 6801| 6200| 5598| 3378| /| 5,47| 5,88| 6,27| 6,66| 6,23| /
25| 8230| 6963| 6302| 5640| 3292| /| 5,39| 5,74| 6,11| 6,48| 6,04| /
30| 7771| 6669| 6028| 5386| 3124| /| 4,72| 5,06| 5,38| 5,70| 5,30| /
35| 7311| 6024| 5497| 4970| 3012| /| 4,35| 4,67| 4,99| 5,31| 4,99| /
40| 5914| 5147| 4683| 4219| 2523| /| 3,41| 3,68| 3,90| 4,13| 3,82| /
43| 5075| 4040| 3712| 3383| 2111| /| 3,26| 3,43| 3,64| 3,85| 3,57| /

18

| -5| 5905| 4764| 3915| 3065| /| /| 10,42| 12,12| 12,41| 12,69| /| /
0| 5681| 4591| 3777| 2962| /| /| 8,49| 10,08| 10,26| 10,44| /| /
5| 5174| 4132| 3814| 3496| 2224| /| 6,73| 7,56| 8,09| 8,62| 8,12| /
10| 6701| 5367| 4978| 4588| 2975| /| 6,33| 7,12| 7,64| 8,16| 7,72| /
15| 8130| 6911| 6340| 5768| 3577| /| 6,10| 6,56| 7,04| 7,51| 7,10| /
20| 8278| 7013| 6447| 5880| 3678| /| 6,05| 6,50| 6,92| 7,33| 6,83| /
25| 8410| 7274| 6635| 5996| 3628| /| 6,00| 6,45| 6,85| 7,25| 6,74| /
30| 8094| 7032| 6406| 5779| 3476| /| 5,27| 5,63| 5,98| 6,34| 5,89| /
35| 7649| 6500| 5999| 5448| 3355| /| 4,73| 4,80| 5,34| 5,79| 5,62| /
40| 6358| 5602| 5130| 4659| 2868| /| 3,75| 4,07| 4,31| 4,54| 4,19| /
43| 5556| 4584| 4199| 3815| 2352| /| 3,56| 3,79| 4,01| 4,23| 3,90| /

20

| -5| 6378| 5190| 4269| 3348| /| /| 11,53| 13,72| 13,99| 14,26| /| /
0| 6157| 5019| 4133| 3247| /| /| 9,39| 11,39| 11,56| 11,72| /| /
5| 5657| 4539| 4195| 3850| 2461| /| 7,48| 8,61| 9,19| 9,77| 9,16| /
10| 6898| 5551| 5155| 4759| 3101| /| 6,83| 7,86| 8,41| 8,97| 8,44| /
15| 8139| 7000| 6388| 5775| 3500| /| 6,44| 7,06| 7,62| 8,17| 7,80| /
20| 8331| 7170| 6643| 6115| 3949| /| 6,42| 6,94| 7,39| 7,84| 7,32| /
25| 8523| 7441| 6845| 6249| 3921| /| 6,40| 6,98| 7,43| 7,87| 7,33| /
30| 8195| 7255| 6664| 6073| 3786| /| 5,63| 6,05| 6,44| 6,84| 6,38| /
35| 7866| 6867| 6328| 5789| 3658| /| 4,98| 5,36| 5,75| 6,14| 5,81| /
40| 6627| 5947| 5483| 5019| 3179| /| 3,95| 4,34| 4,60| 4,86| 4,50| /
43| 5884| 5037| 4609| 4181| 2565| /| 3,74| 4,04| 4,28| 4,52| 4,17| /

25

| -5| 6768| 5498| 4533| 3567| /| /| 10,62| 12,96| 13,07| 13,17| /| /
0| 6547| 5328| 4397| 3465| /| /| 8,85| 11,01| 11,05| 11,08| /| /
5| 6047| 4907| 4530| 4153| 2643| /| 7,20| 8,49| 9,01| 9,53| 8,84| /
10| 7450| 6063| 5624| 5185| 3364| /| 7,88| 9,31| 9,90| 10,50| 9,78| /
15| 8853| 7437| 6932| 6427| 4249| /| 8,43| 9,29| 10,04| 10,79| 10,32| /
20| 8984| 7821| 7282| 6742| 4438| /| 8,15| 8,98| 9,57| 10,16| 9,50| /
25| 9115| 8049| 7441| 6833| 4375| /| 7,90| 8,85| 9,41| 9,97| 9,28| /
30| 8773| 7854| 7250| 6645| 4228| /| 6,75| 7,44| 7,89| 8,34| 7,72| /
35| 8430| 7688| 7122| 6556| 4232| /| 5,84| 6,39| 6,83| 7,28| 6,84| /
40| 7878| 7147| 6658| 6169| 4070| /| 4,80| 5,41| 5,71| 6,01| 5,51| /
43| 7546| 5969| 4886| 3803| /| /| 4,73| 5,18| 5,28| 5,38| /| /

IDOLA S 3.2 HYBRID 28H 8 – Prestazioni raffreddamento / Cooling capacity

“Tw_out

°C”

| “DB/WB

°C”

| Cooling Capacity [W]| EER
---|---|---|---
130%| 100%| 90%| 70%| 50%| 30%| 130%| 100%| 90%| 70%| 50%| 30%

5

| -5| /| /| /| /| /| /| /| /| /| /| /| /
0| /| /| /| /| /| /| /| /| /| /| /| /
5| /| /| /| /| /| /| /| /| /| /| /| /
10| /| /| /| /| /| /| /| /| /| /| /| /
15| /| /| /| /| /| /| /| /| /| /| /| /
20| 5683| 4430| 4049| 3668| 2239| /| 4,96| 5,21| 5,53| 5,85| 5,42| /
25| 6474| 5128| 4651| 4173| 2460| /| 4,36| 4,61| 4,87| 5,14| 4,73| /
30| 7266| 5844| 5292| 4740| 2775| /| 3,85| 4,10| 4,33| 4,56| 4,19| /
35| 7395| 5746| 5173| 4600| 2618| /| 3,22| 3,45| 3,65| 3,84| 3,54| /
40| 6609| 5395| 4851| 4308| 2437| /| 2,62| 2,81| 2,95| 3,09| 2,80| /
43| 5092| 4181| 3494| 2806| 2119| 1431| 2,23| 2,32| 2,33| 2,35| 2,36| 2,37

7

| -5| /| /| /| /| /| /| /| /| /| /| /| /
0| /| /| /| /| /| /| /| /| /| /| /| /
5| /| /| /| /| /| /| /| /| /| /| /| /
10| /| /| /| /| /| /| /| /| /| /| /| /
15| /| /| /| /| /| /| /| /| /| /| /| /
20| 6462| 5121| 4623| 4125| 2379| /| 5,18| 5,52| 5,85| 6,19| 5,73| /
25| 7245| 5830| 5015| 4200| 3384| 2569| 4,56| 4,87| 4,92| 4,96| 5,01| 5,05
30| 8029| 6557| 5634| 4711| 3788| 2865| 4,03| 4,31| 4,35| 4,38| 4,42| 4,45
35| 8195| 7450| 6298| 5196| 4093| 2991| 3,21| 3,35| 3,51| 3,64| 3,76| 3,89
40| 7113| 5892| 5308| 4724| 2697| 1877| 2,86| 3,08| 3,25| 3,41| 3,12| 2,89
43| 5443| 4351| 3709| 3068| 2426| 1784| 2,39| 2,49| 2,51| 2,52| 2,54| 2,55

10

| -5| /| /| /| /| /| /| /| /| /| /| /| /
0| /| /| /| /| /| /| /| /| /| /| /| /
5| /| /| /| /| /| /| /| /| /| /| /| /
10| /| /| /| /| /| /| /| /| /| /| /| /
15| 5972| 4479| 3613| 2747| /| /| 6,84| 7,24| 7,47| 7,69| /| /
20| 7063| 5711| 4908| 4106| 3303| 2500| 5,46| 5,86| 5,93| 5,99| 6,06| 6,12
25| 7817| 6417| 5477| 4538| 3598| 2658| 4,81| 5,17| 5,24| 5,30| 5,37| 5,43
30| 8570| 7141| 6089| 5036| 3984| 2931| 4,25| 4,54| 4,60| 4,65| 4,71| 4,76
35| 8769| 7199| 6498| 5797| 3341| /| 3,80| 4,09| 4,35| 4,60| 4,28| /
40| 7421| 6273| 5669| 5065| 2936| /| 3,14| 3,38| 3,58| 3,77| 3,48| /
43| 5643| 4436| 4021| 3607| 2122| /| 2,58| 2,67| 2,83| 2,99| 2,76| /

15

| -5| 6387| 5143| 4236| 3328| /| /| 10,07| 11,38| 11,62| 11,86| /| /
0| 6173| 4979| 4105| 3230| /| /| 8,69| 9,94| 10,16| 10,38| /| /
5| 5959| 4774| 4406| 4038| 2568| /| 7,30| 7,96| 8,52| 9,08| 8,55| /
10| 6288| 5053| 4686| 4320| 2801| /| 8,54| 9,32| 10,00| 10,69| 10,11| /
15| 7334| 6161| 5682| 5204| 3300| /| 7,38| 7,83| 8,37| 8,91| 8,37| /
20| 8380| 6986| 6368| 5750| 3469| /| 6,22| 6,69| 7,13| 7,58| 7,09| /
25| 9263| 7836| 7092| 6348| 3705| /| 5,52| 5,87| 6,25| 6,63| 6,18| /
30| 10145| 8707| 7869| 7032| 4078| /| 4,93| 5,28| 5,61| 5,95| 5,53| /
35| 10214| 8416| 7680| 6943| 4208| /| 4,43| 4,77| 5,10| 5,44| 5,12| /
40| 8883| 7730| 7033| 6336| 3790| /| 3,51| 3,79| 4,02| 4,25| 3,93| /
43| 6732| 5359| 4924| 4488| 2801| /| 3,16| 3,32| 3,52| 3,73| 3,46| /

18

| -5| 7402| 5972| 4908| 3843| /| /| 10,51| 12,01| 12,22| 12,42| /| /
0| 6808| 5501| 4525| 3549| /| /| 9,28| 10,69| 10,91| 11,13| /| /
5| 6214| 4963| 4581| 4198| 2670| /| 8,04| 8,88| 9,48| 10,09| 9,46| /
10| 7199| 5767| 5349| 4931| 3198| /| 9,05| 10,00| 10,71| 11,41| 10,75| /
15| 8336| 7067| 6475| 5883| 3630| /| 7,71| 8,32| 8,93| 9,54| 9,03| /
20| 9473| 8006| 7360| 6714| 4202| /| 6,36| 6,86| 7,31| 7,76| 7,24| /
25| 10401| 8918| 8140| 7362| 4467| /| 5,75| 6,20| 6,60| 6,99| 6,51| /
30| 11329| 9852| 8979| 8106| 4886| /| 5,26| 5,65| 6,01| 6,37| 5,93| /
**35 *| 11131| 8300| 7847| 7295| 4863| /| 4,69| 5,05**| 5,41| 5,76| 5,43| /
40| 9692| 8541| 7823| 7104| 4376| /| 3,81| 4,15| 4,40| 4,65| 4,30| /
43| 7546| 6230| 5707| 5184| 3196| /| 3,48| 3,71| 3,93| 4,15| 3,84| /

20

| -5| 8213| 6683| 5498| 4312| /| /| 10,82| 12,50| 12,70| 12,89| /| /
0| 7256| 5914| 4870| 3826| /| /| 9,76| 11,31| 11,55| 11,79| /| /
5| 6298| 5053| 4670| 4286| 2740| /| 8,69| 9,69| 10,34| 10,99| 10,29| /
10| 7911| 6367| 5912| 5458| 3556| /| 9,45| 10,55| 11,29| 12,02| 11,31| /
15| 9108| 7833| 7147| 6462| 3916| /| 7,94| 8,70| 9,39| 10,08| 9,62| /
20| 10305| 8868| 8216| 7564| 4885| /| 6,43| 6,95| 7,40| 7,85| 7,33| /
25| 11253| 9823| 9036| 8249| 5176| /| 5,92| 6,46| 6,87| 7,28| 6,78| /
30| 12200| 10801| 9921| 9040| 5636| /| 5,54| 5,94| 6,33| 6,72| 6,28| /
35| 11740| 10249| 9444| 8639| 5459| /| 4,89| 5,26| 5,64| 6,03| 5,70| /
40| 10234| 9183| 8467| 7751| 4909| /| 4,07| 4,47| 4,74| 5,01| 4,64| /
43| 8151| 6977| 6385| 5792| 3554| /| 3,75| 4,06| 4,30| 4,53| 4,18| /

25

| -5| 8735| 7096| 5850| 4603| /| /| 12,31| 14,03| 14,37| 14,71| /| /
0| 7756| 6312| 5209| 4105| /| /| 11,05| 12,86| 13,10| 13,34| /| /
5| 6777| 5499| 5076| 4654| 2962| /| 9,78| 10,76| 11,52| 12,28| 11,57| /
10| 8300| 6755| 6266| 5776| 3747| /| 10,53| 11,60| 12,45| 13,30| 12,59| /
15| 9726| 8169| 7615| 7060| 4668| /| 8,67| 9,55| 10,32| 11,09| 10,61| /
20| 11151| 9708| 9039| 8369| 5509| /| 6,81| 7,50| 7,99| 8,49| 7,93| /
25| 12757| 11264| 10413| 9563| 6123| /| 6,33| 7,09| 7,54| 7,99| 7,44| /
30| 14363| 12859| 11870| 10880| 6923| /| 6,00| 6,61| 7,01| 7,41| 6,86| /
35| 13586| 12390| 11478| 10566| 6820| /| 5,42| 5,94| 6,35| 6,77| 6,36| /
40| 12275| 11137| 10375| 9613| 6342| /| 4,34| 4,89| 5,16| 5,42| 4,97| /
43| 10042| 7943| 6502| 5061| /| /| 4,03| 4,41| 4,50| 4,58| /| /

IDOLA S 3.2 HYBRID 28H 10 – Prestazioni raffreddamento / Cooling capacity

“Tw_out

°C”

| “DB/WB

°C”

| Cooling Capacity [W]| EER
---|---|---|---
130%| 100%| 90%| 70%| 50%| 30%| 130%| 100%| 90%| 70%| 50%| 30%

5

| -5| /| /| /| /| /| /| /| /| /| /| /| /
0| /| /| /| /| /| /| /| /| /| /| /| /
5| /| /| /| /| /| /| /| /| /| /| /| /
10| /| /| /| /| /| /| /| /| /| /| /| /
15| /| /| /| /| /| /| /| /| /| /| /| /
20| 6198| 4832| 4416| 4001| 2442| /| 4,86| 5,11| 5,42| 5,73| 5,31| /
25| 7130| 5647| 5121| 4596| 2709| /| 4,24| 4,49| 4,74| 5,00| 4,60| /
30| 8062| 6484| 5872| 5260| 3080| /| 3,71| 3,95| 4,17| 4,39| 4,03| /
35| 8126| 6314| 5685| 5055| 2877| /| 3,12| 3,28| 3,47| 3,66| 3,37| /
40| 6609| 5395| 4851| 4308| 2437| /| 2,62| 2,81| 2,95| 3,09| 2,80| /
43| 5092| 4181| 3494| 2806| 2119| 1431| 2,23| 2,32| 2,33| 2,35| 2,36| 2,37

7

| -5| /| /| /| /| /| /| /| /| /| /| /| /
0| /| /| /| /| /| /| /| /| /| /| /| /
5| /| /| /| /| /| /| /| /| /| /| /| /
10| /| /| /| /| /| /| /| /| /| /| /| /
15| /| /| /| /| /| /| /| /| /| /| /| /
20| 6722| 5356| 4840| 4323| 2504| /| 4,98| 5,31| 5,63| 5,96| 5,52| /
25| 7728| 6253| 5383| 4512| 3642| 2771| 4,37| 4,68| 4,72| 4,77| 4,81| 4,85
30| 8633| 7174| 6168| 5162| 4155| 3149| 3,86| 4,12| 4,16| 4,19| 4,23| 4,26
35| 8529| 8200| 6965| 5729| 4494| 3258| 3,21| 3,25| 3,42| 3,53| 3,65| 3,76
40| 7043| 5869| 5290| 4711| 2697| 2388| 2,86| 3,08| 3,25| 3,41| 3,12| 2,98
43| 5389| 4334| 3697| 3059| 2422| 1784| 2,39| 2,49| 2,51| 2,52| 2,54| 2,55

10

| -5| /| /| /| /| /| /| /| /| /| /| /| /
0| /| /| /| /| /| /| /| /| /| /| /| /
5| /| /| /| /| /| /| /| /| /| /| /| /
10| /| /| /| /| /| /| /| /| /| /| /| /
15| 6302| 4727| 3813| 2899| /| /| 5,89| 6,24| 6,43| 6,62| /| /
20| 7193| 5816| 4999| 4181| 3364| 2546| 5,17| 5,55| 5,61| 5,67| 5,73| 5,79
25| 8264| 6785| 5791| 4798| 3804| 2810| 4,56| 4,91| 4,97| 5,03| 5,09| 5,15
30| 9335| 7779| 6633| 5486| 4340| 3193| 4,05| 4,32| 4,37| 4,43| 4,48| 4,53
35| 9482| 7785| 7027| 6269| 3613| /| 3,72| 4,01| 4,26| 4,51| 4,19| /
40| 7421| 6273| 5669| 5065| 2936| /| 3,14| 3,38| 3,58| 3,77| 3,48| /
43| 5643| 4436| 4021| 3607| 2122| /| 2,58| 2,67| 2,83| 2,99| 2,76| /

15

| -5| 6834| 5503| 4532| 3561| /| /| 9,92| 11,21| 11,45| 11,68| /| /
0| 6605| 5328| 4392| 3456| /| /| 8,56| 9,79| 10,01| 10,23| /| /
5| 6376| 5108| 4714| 4321| 2748| /| 7,19| 7,84| 8,39| 8,94| 8,42| /
10| 6545| 5259| 4878| 4496| 2916| /| 8,73| 9,53| 10,23| 10,92| 10,33| /
15| 7607| 6389| 5893| 5397| 3423| /| 7,35| 7,80| 8,34| 8,87| 8,33| /
20| 8668| 7226| 6587| 5948| 3589| /| 5,97| 6,42| 6,85| 7,28| 6,81| /
25| 9872| 8352| 7559| 6766| 3949| /| 5,24| 5,58| 5,94| 6,30| 5,88| /
30| 11076| 9507| 8593| 7678| 4453| /| 4,62| 4,95| 5,26| 5,58| 5,19| /
35| 11033| 9091| 8296| 7500| 4546| /| 4,21| 4,53| 4,85| 5,16| 4,86| /
40| 8883| 7730| 7033| 6336| 3790| /| 3,51| 3,79| 4,02| 4,25| 3,93| /
43| 6732| 5359| 4924| 4488| 2801| /| 3,16| 3,32| 3,52| 3,73| 3,46| /

18

| -5| 7936| 6403| 5258| 4112| /| /| 10,35| 11,83| 12,04| 12,24| /| /
0| 7299| 5898| 4848| 3798| /| /| 9,14| 10,53| 10,75| 10,96| /| /
5| 6662| 5320| 4909| 4497| 2857| /| 7,92| 8,74| 9,34| 9,93| 9,32| /
10| 7476| 5989| 5553| 5117| 3314| /| 9,51| 10,51| 11,25| 12,00| 11,30| /
15| 8680| 7358| 6740| 6122| 3772| /| 7,91| 8,54| 9,17| 9,80| 9,28| /
20| 9884| 8354| 7678| 7002| 4377| /| 6,31| 6,80| 7,24| 7,69| 7,18| /
25| 11110| 9526| 8692| 7858| 4762| /| 5,55| 5,99| 6,37| 6,75| 6,28| /
30| 12335| 10726| 9773| 8819| 5309| /| 4,91| 5,26| 5,60| 5,93| 5,53| /
35| 12055| 9900| 9195| 8391| 5256| /| 4,49| 4,55| 5,15| 5,51| 5,21| /
40| 9711| 8558| 7836| 7114| 4376| /| 3,81| 4,15| 4,40| 4,65| 4,30| /
43| 7561| 6242| 5716| 5191| 3196| /| 3,48| 3,71| 3,93| 4,15| 3,84| /

20

| -5| 8788| 7151| 5883| 4614| /| /| 10,66| 12,31| 12,50| 12,69| /| /
0| 7763| 6328| 5211| 4094| /| /| 9,61| 11,14| 11,38| 11,61| /| /
5| 6739| 5407| 4996| 4586| 2931| /| 8,56| 9,54| 10,18| 10,82| 10,13| /
10| 8171| 6576| 6106| 5637| 3673| /| 10,18| 11,37| 12,16| 12,95| 12,18| /
15| 9480| 8153| 7439| 6726| 4076| /| 8,38| 9,18| 9,90| 10,63| 10,14| /
20| 10789| 9285| 8602| 7919| 5114| /| 6,57| 7,10| 7,56| 8,02| 7,49| /
25| 11998| 10474| 9635| 8796| 5519| /| 5,79| 6,32| 6,72| 7,13| 6,64| /
30| 13206| 11691| 10738| 9786| 6101| /| 5,14| 5,51| 5,87| 6,23| 5,82| /
35| 12697| 11084| 10214| 9343| 5904| /| 4,73| 5,09| 5,46| 5,84| 5,52| /
40| 10234| 9183| 8467| 7751| 4909| /| 4,07| 4,47| 4,74| 5,01| 4,64| /
43| 8151| 6977| 6385| 5792| 3554| /| 3,75| 4,06| 4,30| 4,53| 4,18| /

25

| -5| 9346| 7593| 6260| 4926| /| /| 12,13| 13,82| 14,16| 14,49| /| /
0| 8299| 6754| 5574| 4393| /| /| 10,88| 12,66| 12,90| 13,14| /| /
5| 7251| 5884| 5432| 4979| 3169| /| 9,63| 10,60| 11,35| 12,10| 11,40| /
10| 8796| 7159| 6640| 6122| 3971| /| 10,22| 11,26| 12,09| 12,91| 12,22| /
15| 10641| 8938| 8331| 7725| 5107| /| 8,84| 9,74| 10,52| 11,30| 10,81| /
20| 12485| 10869| 10120| 9370| 6168| /| 7,45| 8,21| 8,75| 9,29| 8,68| /
25| 13929| 12299| 11370| 10442| 6686| /| 6,42| 7,18| 7,64| 8,10| 7,54| /
30| 15372| 13763| 12704| 11645| 7409| /| 5,51| 6,08| 6,44| 6,81| 6,30| /
35| 14507| 13230| 12256| 11282| 7283| /| 5,06| 5,54| 5,92| 6,31| 5,93| /
40| 12275| 11137| 10375| 9613| 6342| /| 4,34| 4,89| 5,16| 5,42| 4,97| /
43| 10042| 7943| 6502| 5061| /| /| 4,03| 4,41| 4,50| 4,58| /| /

Lamborghini Caloreclima – www.lamborghinicalor.it è un marchio commerciale di FERROLI S.p.A. – Via Ritonda 78/a
37047 San Bonifacio (Verona) Italy – tel. +39.045.6139411 – fax. +39.045.6100933 www.ferroli.co

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Lamborghini User Manuals

Related Manuals