Danby DPA100E5WDB-6 Portable AC
Product Information
- Product Name: Portable Air Conditioner
- Model Numbers: DPA100E5WDB-6, DPA100HE5WDB-6, DPA100HE5BDB-6
- Manufacturer: Danby Products Limited, Ontario, Canada N1H 6Z9
- Date: 2021.10.21
Product Usage Instructions
- Read the Owner’s Manual for installation help, troubleshooting, and maintenance assistance.
- For self-service tools, FAQs, and more information, visit www.Danby.com and search your model number in the search bar.
- If you need customer service, fill out the web form at www.danby.com/support. Your submission will be directed to an expert who can assist you. Average response times are between 20 minutes and 2 hours during EST business hours.
- If you prefer to speak with a representative, call 1-800-263-2629. Please note that hold times may exceed one hour during peak hours.
Important Safety Information
- Read and follow all safety instructions provided.
- The appliance must be grounded to reduce the risk of electrical shock.
- Do not damage the refrigerant circuit to avoid the risk of fire or explosion.
- This appliance is not intended for use by individuals with reduced capabilities or lack of experience or knowledge, unless supervised or trained by a responsible person.
- Do not allow the refrigerant to vent into the open air during maintenance or disposal of the air conditioner.
- Any person working on the refrigerant circuit should hold a valid certificate authorizing their competence to handle refrigerants safely.
- Ensure the availability of appropriate fire extinguishing equipment when conducting hot work on the refrigeration equipment or associated parts.
- Follow manufacturer’s recommendations for servicing and perform maintenance and repair under the supervision of a competent person.
- Properly recover the refrigerant during maintenance or disposal and do not discharge it directly into the air.
Welcome to the Danby family.
- We are proud of our quality products and we believe in dependable service. We suggest that you read this owner’s manual before plugging in your new appliance as it contains important operation information, safety information, troubleshooting, and maintenance tips to ensure the reliability and longevity of your appliance.
- You are entitled to the warranty coverage as described in the owner’s manual provided with your new appliance.
- Please write down your appliance information below. You must keep the original proof of purchase receipt to validate and receive warranty services.
- Register your product online and receive a FREE 2 MONTH WARRANTY EXTENSION after filling out a product survey, at www.danby.com/support/product-registration/Model
- Number: ____
- Serial Number: ____
- Date of Purchase: __
Need Help?
- Read your Owner’s Manual for installation help, troubleshooting, and maintenance assistance.
- Visit www.Danby.com to access self-service tools, FAQs and much more by searching your model number in the search bar.
- For the Quickest Customer Service, please fi ll out the web form at www.danby.com/support. Your submission will go directly to an expert on your particular appliance. Our average response times are between 20 minutes and 2 hours, during EST business hours.
- Call 1-800-263-2629 – please note that during peak hours, hold times can exceed one hour.
Important Safety Information
READ AND FOLLOW ALL SAFETY INSTRUCTIONS
SAFETY REQUIREMENTS
DANGER: Risk of fi re or explosion. Flammable refrigerant used. Do not
damage the refrigerant circuit.
- Ensure that servicing is done by factory authorized service personnel, to minimize product damage or safety issues.
- Consult repair manual or owner’s guide before attempting to service this product. All safety precautions must be followed.
- Dispose of properly in accordance with federal or local regulations.
- Follow handling instructions carefully.
- Keep ventilation openings, in the appliance clear of obstruction.
- Do not use mechanical devices or other means to accelerate the defrosting process.
- Children should be supervised to ensure that they do not play with the appliance.
- Do not store or install the appliance near continuously operating ignition sources such as open flames or a gas stove.
- Do not operate near water or in a wet room.
- Do not pierce or burn.
- Be aware that refrigerants may not contain an odor.
- The appliance must be stored so as to prevent mechanical damage from occurring.
All wiring must comply with local and national codes and must be installed by
a qualified electrician. Check the available power supply and resolve any
wiring problems before installing and operating this appliance.
The rating plate located on the right side of the appliance just above the
power cord contains electrical and other technical data.
This appliance is not intended for use by persons (including children) whose
physical, sensory or mental capabilities may be different or reduced, or who
lack experience or knowledge, unless such persons receive supervision or
training to operate the appliance by a person responsible for their safety.
GROUNDING INSTRUCTIONS
- This appliance must be grounded. Grounding reduces the risk of electrical shock by providing an escape wire for the electrical current.
- This appliance has a cord that has a grounding wire with a 3-prong plug. The power cord must be plugged into an outlet that is properly grounded. If the outlet is a 2-prong wall outlet, it must be replaced with a properly grounded 3-prong wall outlet. The serial rating plate indicates the voltage and frequency the appliance is designed for.
- WARNING – Improper use of the grounding plug can result in a risk of electric shock.
- Consult a qualified electrician or service agent if the grounding instructions are not completely understood, or if doubt exists as to whether the appliance is properly grounded.
- Do not connect your appliance to extension cords or together with another appliance in the same wall outlet. Do not splice the power cord. Do not under any circumstances cut or remove the third ground prong from the power cord. Do not use extension cords or ungrounded (two prongs) adapters.
- If the power supply cord is damaged, it must be replaced by the manufacturer, its service agent or similar qualified person in order to avoid hazard.
CAUTION: RISK OF FIRE
Flammable refrigerant used. When maintaining or disposing of the air
conditioner, the refrigerant must not be allowed to vent into the open air.
- Any person involved with working on the refrigerant circuit should hold a current, valid certificate from an industry accredited assessment authority which authorizes their competence to handle refrigerants safely in accordance with an industry recognized assessment specification.
- Servicing shall only be performed as recommended by the manufacturer. Maintenance and repair requiring the assistance of other skilled personnel shall be carried out under the supervision of the person competent in the use of fl ammable refrigerants.
- When maintaining or disposing of the appliance the refrigerant must be recovered properly and should not be allowed to discharge to the air directly.
Information on servicing
-
Checks to the area: Prior to beginning work on systems containing fl ammable refrigerants, safety checks are necessary to ensure that the risk of ignition is minimized. For repair to the refrigerating system, the following precautions shall be complied with prior to conducting work on the system.
-
Work procedure: Work shall be undertaken under a controlled procedure so as to minimize the risk of a fl ammable gas or vapour being present while the work is being performed.
-
General work area: All maintenance staff and others working in the local area shall
be instructed on the nature of work being carried out. Work in confined spaces shall be avoided. The area around the work space shall be sectioned off. Ensure that the conditions within the work area have been made safe by removing all fl ammable material. -
Checking for the presence of refrigerant: The area shall be checked with an appropriate refrigerant detector prior to and during work to ensure the technician is aware of potentially fl ammable atmospheres. Ensure that the leak detection equipment being used is suitable
for use with fl ammable refrigerants, i.e. non-sparking, adequately sealed and intrinsically safe. -
Presence of fi re extinguisher: If any hot work is to be conducted on the refrigeration equipment or any associated parts, appropriate fi re extinguishing equipment shall be available
to hand. Have a dry powder or C02 fi re extinguisher adjacent to the work area. -
No ignition sources: No person carrying out work in relation to a refrigeration system which involves exposing any pipe work that contains or has contained fl ammable refrigerant shall use any sources of ignition in such a manner that it may lead to risk of fi re or explosion. All possible ignition sources including cigarette smoking, should be kept sufficiently far away from the site of installation, repairing, removing and disposal during which fl ammable refrigerant can possibly be released to the surrounding space. Prior to work taking place, the area around the equipment is to be surveyed to make sure there are no fl ammable hazards or ignition risks. No smoking signs shall be displayed.
-
Ventilated area: Ensure that the area is in the open or that it is adequately ventilated before breaking into the system or conducting any hot work. A degree of ventilation shall continue during the period that the work is carried out. The ventilation should safely disperse any released refrigerant and preferable expel it externally into the atmosphere.
-
Checks to the refrigeration equipment: Where electrical components are being changed, they shall be fi t for the purpose and to the correct specification. At all times the manufacturer’s maintenance and service guidelines shall be followed. If in doubt consult the manufacturer’s technical department for assistance.
The following checks shall be applied to installations using fl ammable refrigerants:- The charge size is in accordance with the room size within which the refrigerant containing parts are installed.
- The ventilation machinery and outlets are operating adequately and are not obstructed.
- If an indirect refrigerating circuit is being used, the secondary circuit shall be checked for the presence of refrigerant.
- Marking to the equipment continues to be visible and legible. Markings and signs that become illegible must be corrected.
- Refrigeration pipe or components are installed in a position where they are unlikely to be exposed to any substance which may corrode refrigerant containing components, unless the components are constructed of materials which are inherently resistant to being corroded or are suitable protected against being corroded.
-
Checks to electrical devices: Repair and maintenance to electrical components shall include initial safety checks and component inspection procedures. If a fault exists that could compromise safety, then no electrical supply shall be connected to the circuit until it is satisfactorily dealt with. If the fault cannot be corrected immediately but it is necessary to continue operation, an adequate temporary solution shall be used. This shall be reported to the owner of the equipment so all parties are advised.
Initial safety checks shall include:
- That capacitors are discharged. This shall be done in a safe manner to avoid possibility of sparking.
- That no live electrical components and wiring are exposed while charging, recovering or purging the system.
- That there is continuity of earth bonding.
Repairs to sealed components
- During repairs to sealed components, all electrical supplies shall be disconnected from the equipment being worked upon prior to any removal of sealed covers, etc. If it is absolutely necessary to have an electrical supply to equipment during servicing then a permanently operating form of leak detection shall be located at the most critical point to warn of a potentially hazardous situation.
- To ensure that by working on electrical components the casing is not altered in such a way that the level of protection is affected, particular attention shall be paid to the following:
- Damage to cables, excessive number of connections, terminals not made to original specification, damage to seals, incorrect fitting of glands, etc.
- Ensure the apparatus is mounted securely.
- Ensure that seals or sealing materials have not degraded such that they no longer serve the purpose of preventing the ingress of flammable atmospheres. Replacement parts shall be in accordance with the manufacturer’s specifications.
Note: The use of silicon sealant may inhibit the effectiveness of some types of leak detection equipment. Intrinsically safe components do not have to be isolated prior to working on them.
Repair to intrinsically safe components
- Do not apply any permanent inductive or capacitance loads to the circuit without ensuring that this will not exceed the permissible voltage and current permitted for the equipment in use.
- Intrinsically safe components are the only types that can be worked on while live in the presence of a flammable atmosphere.
- The test apparatus shall be at the correct rating. Replace components only with parts specified by the manufacturer.
- Other parts may result in the ignition of refrigerant in the atmosphere from a leak.
Cabling
Check that cabling will not be subject to wear, corrosion, excessive pressure,
vibration, sharp edges or any other adverse environmental effects. The check
shall also take into account the effects of aging or continual vibration from
sources such as compressors or fans.
Detection of fl ammable refrigerants
Under no circumstances shall potential sources of ignition be used in the
searching for or detection of refrigerant leaks. A halide torch or any other
detector using a naked fl ame shall not be used.
Leak detection methods
The following leak detection methods are deemed acceptable for systems
containing fl ammable refrigerants:
- Electronic leak detectors shall be used to detect fl ammable refrigerants but the sensitivity may not be adequate or may need recalibration. Detection equipment shall be calibrated in a refrigerant-free area. Ensure that the detector is not a potential source of ignition and is suitable for the refrigerant used.
- Leak detection equipment shall be set at a percentage of the LFL of the refrigerant and shall be calibrated to the refrigerant employed and the appropriate percentage of gas (25%maximum) is confirmed.
- Leak detection fluids are suitable for use with most refrigerants but the use of detergents containing chlorine shall be avoided as the chlorine may react with the refrigerant and corrode the copper or pipe-work.
- If a leak is suspected, all naked flames shall be removed or extinguished.
- If a leakage of refrigerant is found which requires brazing, all of the refrigerant shall be recovered from the system or isolated by means of shut off valves in a part of the system remote from the leak. Oxygen free nitrogen (OFN) shall then be purged through the system both before and during the brazing process.
Removal and evacuation
When breaking into the refrigerant circuit to make repairs or for any other
purpose conventional procedures shall be used. However, it is important that
the best practice is followed since flammability is a consideration. The
following procedures shall be adhered to:
- Remove refrigerant.
- Purge the circuit with inert gas.
- Evacuate.
- Purge again with inert gas.
- Open the circuit by cutting or brazing.
- The refrigerant charge shall be recovered into the correct recovery cylinders. The system shall be flushed with OFN to render the unit safe. This process may need to be repeated several times. Compressed air or oxygen shall not be used for this task.
- Flushing shall be achieved by breaking the vacuum in the system with OFN and continuing to fill until the working pressure is achieved, then venting to atmosphere and finally pulling down to a vacuum. This process shall be repeated until no refrigerant is within the system. When the final OFN charge is used, the system shall be vented down to atmospheric pressure to enable work to take place. This operation is absolutely vital is brazing operations on the pipe-work are to take place.
- Ensure that the outlet for the vacuum pump is not close to any ignition sources and there is ventilation available.
Charging procedures
In addition to conventional charging procedures, the following requirements
shall be followed:
- Ensure that contamination of different refrigerants does not occur when using charging equipment. Hoses or lines shall be as short as possible to minimize the amount of refrigerant contained in them.
- Cylinders shall be kept upright.
- Ensure that the refrigeration system is earthed prior to charging the system with refrigerant.
- Label the system when charging is complete, if not already labeled.
- Extreme care shall be taken not to overfill the refrigeration system.
- Prior to recharging the system it shall be pressure tested with OFN. The system shall be leak tested on completion of charging but prior to commissioning. A follow up leak test shall be carried out prior to leaving the site.
Decommissioning
Before carrying out this procedure, it is essential that the technician is
completely familiar with the equipment in all its detail. It is recommended
good practice that all refrigerants are recovered safely. Prior to the task
being carried out, an oil and refrigerant sample shall be taken in case
analysis is required prior to re-use of reclaimed refrigerant. It is essential
that electrical power is available before the task is commenced.
- Become familiar with the equipment and its operation.
- Isolate system electrically.
- Before attempting the procedure ensure that:
- Mechanical handling equipment is available if required for handling refrigerant cylinders.
- All personal protective equipment is available and being used correctly.
- The recovery process is supervised at all times by a competent person.
- Recovery equipment and cylinders conform to the appropriate standards.
- Pump down refrigerant system, if possible.
- If a vacuum is not possible, make a manifold so that refrigerant can be removed from various parts of the system.
- Make sure that cylinder is situated on the scales before recovery takes place.
- Start the recovery machine and operate in accordance with the manufacturer’s instructions.
- Do not overfill cylinders. No more than 80%volume liquid charge.
- Do not exceed the maximum working pressure of the cylinder, even temporarily.
- When the cylinders have been filled correctly and the process is completed, make sure that the cylinders and the equipment are removed from the site promptly and all isolation valves on the equipment are closed off.
- Recovered refrigerant shall not be charged into another refrigeration system unless it has been cleaned and checked.
Labeling
Equipment shall be labeled stating that it has been decommissioned and emptied
of refrigerant. The label shall be dated and signed. Ensure that there are
labels on the equipment stating the equipment contains fl ammable refrigerant.
Recovery
- When removing refrigerant from a system, either for servicing or decommissioning, it is recommended good practice that all refrigerants are removed safely.
- When transferring refrigerant into cylinders, ensure that only appropriate refrigerant recovers cylinders are employed. Ensure that the correct number of cylinders for holding the total system charge are available. All cylinders to be used are designed for the recovered refrigerant and labeled for that refrigerant, i.e. special cylinders for the recovery of refrigerant. Cylinders shall be complete with pressure relief valve and associated shut-off valves in good working order. Empty recovery cylinders are evacuated and, if possible, cooled before recovery occurs.
- The recovery equipment shall be in good working order with a set of instructions concerning the equipment that is at hand and shall be suitable for the recovery of fl ammable refrigerants. In addition, a set of calibrated weighing scales shall be available and in good working order. Hoses shall be complete with leak-free disconnect couplings and in good condition. Before using the recovery machine, check that is it in satisfactory working order, has been properly maintained and that any associated electrical components are sealed to prevent ignition in the event of a refrigerant leak. Consult the manufacturer if in doubt.
- The recovered refrigerant shall be returned to the refrigerant supplier in the correct recovery cylinder and the relevant waste transfer note shall be arranged. Do not mix refrigerants in recovery units and especially not in cylinders. If compressors or compressor oils are to be removed, ensure that they have been evacuated to an acceptable level to make certain that fl ammable refrigerant does not remain within the lubricant. The evacuation process shall be carried out prior to returning the compressor to the suppliers. Only electric heating to the compressor body shall be employed to accelerate this process. When oil is drained form a system, it shall be carried out safely.
INSTALLATION INSTRUCTIONS
ACCESSORIES
- Air outlet adapter
- Exhaust hose
- Window slider adapter
- 8 bolts
- Window slider A and B
- Window slider C and D
- Foam seal A and B (adhesive)
- Foam seal C (non-adhesive)
- Drain hose
- Remote control and batteries
Important: The drain hose is only included on models that include heat mode.
REQUIRED TOOLS
- Medium sized Phillips screwdriver
- Tape measure or ruler
- Knife or scissors
- Saw (in the event that the window sliders need to be cut to size)
ASSEMBLING THE WINDOW KIT
- Attach the air outlet adapter and the window slider adapter onto either end of the exhaust hose.
- Insert the air outlet adapter into the back of the appliance by placing over the air exhaust and then pushing in the direction of the arrow to lock into place.
- Measure the window opening where the window kit will be installed. Assemble as many sliders as necessary to fi t the window. If the length of the window requires all three sliders, use two bolts to fasten the sliders at the correct length. If the window opening is less that the minimum length of a single slider, use the slider that has the hole in it and cut it to the correct length. Make sure not to cut the end that has the hole as this is necessary to attach the exhaust hose adapter.
INSTALLING THE WINDOW KIT
The window kit can be used in either a hung window or a sliding window
application. The images at the right are for a hung window. The steps for a
sliding window are the same.
- Cut the adhesive foam seals A and B to the correct length for the window. Attach them to the window sash and frame as shown.
- Insert the assembled window slider kit into the window opening.
- Cut the non-adhesive foal seal C to match the width of the window. Insert the foam seal between the glass and the window frame to prevent air and insects from getting into the room.
- Attach the window slider adapter to the hole in the window slider kit.
- Note: It may be easier to attach the window slider adapter to the window slider kit before placing the kit in the window.
- Note: Do not over extend or bend the hose as this will impede air flow.
IMPORTANT WARNING
Do not leave this appliance unattended in a space where people or animals who
cannot react to a malfunction are located. A malfunction such as the exhaust
hose becoming dislocated, can cause extreme overheating or death in an
enclosed, unattended space.
OPERATING INSTRUCTIONS
FEATURES
- Control panel
- Louver
- Remote control receiver
- Handle (both sides)
- Casters
- Air intake grille
- Air outlet grille
- Continuous drain
- Air intake grille
- Power cord
- Condenser drain
LOCATION
-
Place the air conditioner on a smooth, level floor that is strong enough to support it and all included accessories.
-
Make sure the appliance is level to minimize noise and vibration.
-
The appliance must be installed near a grounded receptacle and the overflow drain outlet on the rear of the appliance must be accessible.
-
Do not cover air inlets or outlets or the remote control receiver on the control panel.
-
The appliance requires 45 cm (17.7 inches) of clearance on the front and sides.
-
The appliance requires at least 50 cm (20 inches) of clearance on the back.
CONTROL PANEL
- Timer button: Used to set the automatic timer.
- Fan button: Used to choose the fan speed.
- Temperature control buttons : Used to increase or decrease the set temperature.
- Mode button: Used to choose the mode; cool, fan or dry.
- Power button: Used to turn the appliance on or off.
Note: Images are for instructional purposes only. Your control panel may look slightly different.
OPERATING MODES
Cool Mode
- Press the mode button to choose cool mode.
- Use the temperature control buttons to choose the desired temperature.
- Use the fan button to choose the desired fan speed.
- The temperature can be set within a range of 18
- 32°C (64 – 90°F).
- The exhaust hose should be installed during cool mode to ensure the best results.
Fan Mode
- Press the mode button to choose fan mode.
- Press the fan button to choose the desired fan speed.
- The exhaust hose does not need to be installed during fan mode.
OPERATING MODES Dry Mode
- Press the mode button to choose dry mode.
- The fan speed will be set to auto.
- The exhaust hose should be installed during dry mode to ensure the best results.
- It may be necessary to install the continuous drain hose during dry mode to remove excess water.
Heat Mode
- Press the mode button to choose heat mode.
- Use the temperature control buttons to choose the desired temperature.
- Press the fan button to choose the desired fan speed.
- The temperature can be set within a range of 13
- 27°C (55 – 81°F).
- The exhaust hose should be installed during heat mode to ensure the best results.
- It may be necessary to install the continuous drain hose during heat mode to remove excess water.
- Heat mode is not available on all models.
Smart Mode
- Press the mode button the choose smart mode.
- The appliance will choose whether to run cool, fan or heat mode automatically based on the ambient temperature in the air.
- Smart mode is not available on all models.
TIMER FUNCTION
The timer function can be used to turn the appliance on or off after a period
of time to conserve energy.
To set the timer to turn the appliance off:
- While the appliance is running, press the timer button. The time display will fl ash.
- Press the timer button to choose the number of hours before the appliance will turn off.
- Wait 5 seconds to confirm the setting. The timer icon will illuminate.
To set the timer to turn the appliance on:
- Turn the appliance on and choose the desired mode and settings. Turn the appliance off.
- While the appliance is turned off, press the timer button. The time display will fl ash.
- Press the timer button to choose the number of hours before the appliance will turn on.
- Wait 5 seconds to confirm the setting. The timer icon will illuminate.
Notes: Turning the appliance on or off at any time or adjusting the timer setting to 0 hours will cancel the timer settings.
CHILD LOCK
- The child lock can be activated by pressing the temperature control buttons on the remote control at the same time for 3 seconds. The buttons on the remote control cannot be used while the child lock is active. To deactivate the child lock, press and hold the temperature control buttons at the same time for 3 seconds.
- The child lock can only be activated or deactivated using the remote control.
TURBO
The turbo setting will run the air conditioner at maximum settings to cool the
room as quickly
as possible. Press the turbo button and the turbo symbol will fl ash 10 times
on the display. The fan speed and temperature cannot be adjusted.
SLEEP
- The sleep feature can be used to conserve energy during sleeping hours. This feature can be used during cool and heat mode.
- When selected in cool mode, the set temperature will increase by 1 degree per hour for 2 hours. The appliance will hold the new set temperature for 6 hours before automatically returning to normal operation.
- When selected in heat mode, the set temperature will decrease by 1 degree per hour for 3 hours. The appliance will hold the new set temperature for 5 hours before automatically returning to normal operation.
- The sleep feature can only be activated with the remote control and can be canceled at any time by pressing the sleep button.
FOLLOW ME
- The follow me feature can only be activated from the remote control.
- The remote control has a thermostat inside of it. Keep the remote control will you and the air conditioner will automatically adjust the set temperature based on the ambient temperature at your location.
- The maximum distance for the follow me feature is 8 meters (26 feet). This feature is available in cool and auto modes.
- To activate follow me, press the turbo button and then press the temperature control buttons until the follow me icon appears on the display and then press the turbo button to confirm the selection.
- The remote control display will show the actual ambient temperature at its location. The remote control will sent a signal to the air conditioner every 20 minutes to update the set temperature. If the air conditioner does not receive a signal from the remote control during any 25 minute period, the follow me feature will deactivate.
- To deactivate follow me, press the turbo button and then press the temperature control buttons until the follow me icon fl ashes on the display and then press the turbo button to confirm the selection.
REMOTE CONTROL
- Power button: Used to turn the appliance on or off.
- Turbo button: The turbo function can be used to cool a room quickly.
- Temperature control buttons: Used to increase or decrease the set temperature.
- Timer button: Used to set the timer function.
- Mode button: Used to choose the mode.
- Swing button: The swing feature is not available on this model.
- Sleep button : Used to set the sleep function.
- Fan button : Used to set the fan speed.
- °C/°F button: Used to change the temperature scale between Celsius and Fahrenheit.
Note: The remote control will function within a range of 7 meters (23 feet) of the appliance.
REMOTE DISPLAY
The digital display on the remote control will show the below symbols. Please
note that not all features may be available on your model. If you try to use a
feature that your model does not support, the appliance will default to fan
mode.
REPLACING THE REMOTE BATTERIES
This air conditioner comes with two AAA batteries. Place the batteries in the
remote control before use.
- Slide the back cover from the remote downward to expose the battery compartment.
- Insert the batteries, ensure to match the (+) and (-) symbols on the ends of the batteries with the symbols inside the battery compartment.
- Slide the battery cover back into place.
Notes :
- The air conditioner will not respond if curtains, doors or other materials block the signal from the remote control to the unit.
- Prevent any liquid from contact with the remote control. Do not expose the remote control to direct sunlight or heat.
- If the infrared signal receiver on the indoor unit is exposed to direct sunlight, the air conditioner may not function properly. Use curtains to prevent the sunlight from falling on the receiver.
- Do not mix old and new batteries or batteries of different types.
- Do not leave the batteries in the remote control if it is not going to be used for more than 2 months.
- This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation.
- If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna
- Increase the separation between the equipment and receiver
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected
- Consult the dealer or an experienced radio/TV technician for help
Changes or modifications not approved by the party responsible for FCC compliance could void the user’s authority to operate the equipment. This appliance complies with Part 15 of the
FCC Rules
Operation is subject to the following conditions:
- This device may not cause harmful interference.
- This device must accept any interference received, including interference that may cause undesired operation.
This device complies with Canadian CAN ICES-3 (B) / NMB-3 (B)
IMPORTANT
Do not dispose of batteries as unsorted municipal waste. Refer to local laws
for proper disposal of batteries.
WATER DRAINAGE
- When the internal drain pan becomes full the appliance will stop operating and the display will show error code “Ft”. The air conditioning or dehumidifying action will stop but the fan may continue to operate.
- There are two methods to drain water from the appliance:
Drain Plug
- Turn the appliance off and unplug it from the power source.
- Carefully move the appliance to a location where the water can be drained.
- Remove the drain plug and allow the water to completely drain.
- Replace the bottom drain plug, pressing firmly to ensure a tight fi t and no leaks.
- The “Ft” error symbol will disappear and the appliance will resume regular function once power is restored.
Continuous Drain
- During the dry mode, you may wish to set up the continuous drain option so that the appliance will automatically drain collected water. Ensure that the appliance is turned off and unplugged from the power source before setting up the drain hose.
- Remove the drain plug and attach the drain hose that was provided with the appliance. Ensure that there are no kinks or bends in the drain hose as this can stop water from draining.
- Place the open end of the drain hose over the receptacle that the appliance will drain into; this could be a basement floor drain, a sink or similar.
- Remember that there is no drain pump in this appliance, the continuous drain is activated by gravity only. Ensure that the drain hose goes straight down toward the floor from the drain connection. If the hose is not positioned directly downwards, water will not drain correctly.
- This appliance also includes a secondary drain in the middle of the back panel. If the hose is not draining when attached to the lower drain, move the hose to the middle drain using the same steps outlined above. The middle drain being higher off the ground, can provide better draining based on the pull of gravity.
CARE & MAINTENANCE
CLEANING
- Unplug the appliance before cleaning or servicing.
- Clean the cabinet with a lukewarm damp cloth and neutral detergent. Dry the cabinet with a lint-free dry cloth.
- Do not use gasoline, paint thinner or other chemicals to clean the appliance.
- Do not wash the appliance directly under a tap or using a hose. It may cause electrical damage.
AIR FILTER
- The filters in this appliance should be cleaned every two weeks to ensure efficient performance.
- In households with animals, the air filters may need to be cleaned more often and the external grills may need to be wiped to prevent blocked air flow.
LONG-TERM STORAGE
- Drain all water from the appliance.
- Run the appliance on fan mode for half a day in a warm room to dry the inside of the appliance and prevent mold formation.
- Turn off the appliance and unplug it, wrap the cord and bundle it with tape.
- Remove the battery from the remote control.
- Clean the air filters and reinstall them.
- Store the appliance in a cool, dark place. Prolonged exposure to direct sunlight or extreme heat can shorten the lifespan of the appliance.
DISPOSAL
- This appliance should not be treated as regular household waste. Check for local regulatory compliance regarding the approved and safe disposal of this appliance.
- Do not dispose of batteries as unsorted municipal waste. Refer to local laws for proper disposal of batteries.
ERROR CODES
- Lt – low temperature – the appliance will pause functioning if ice forms on the internal structure; the appliance will resume normal functioning automatically when the ice melts
- PF – sensor failure – unplug the appliance for 5 minutes to reset the internal sensors; if the error code persists after plugging the appliance back in, please contact consumer care for servicing information
- Ft – water tray is full – attach drain hose and drain excess water
FREQUENTLY ASKED QUESTIONS
-
Can I leave my AC in place through the winter?
This is not recommended. -
What are the standard wattage and amps used?
Information pertaining to watts and amps can be found on the rating plate located on the side of the unit. -
When should I use the exhaust hose?
The exhaust hose should be used in cool, dry, heat and auto modes. It is not required in fan mode. -
Can I use an extension cord?
No, an extension cord may not be used. -
Can I extend the length of the exhaust hose?
No. The unit was designed with the length of the hose in mind and has only been tested under those conditions. Instead use an additional fan to blow the cool air to other locations. -
When should I use the drain hose?
The drain hose should be used in heat mode, dry mode or if using the continuous drain. -
Where do I drain water from?
The water drains from the drainage port. If you are not using the continuous drain, the internal pan drains from the bottom outlet.
Odors
Odour is caused by the formation of mold or mildew on internal surfaces. This
can happen when there is poor air circulation, a dirty fi lter or the air
conditioner was not used for a period of time.
- Ensure the filter is clean.
- Run the unit on fan mode to remove any internal moisture.
- Check for any blockages in the drain lines and ensure there are no obstructions.
Please give your unit a hard reboot. Unplug it and plug it back in after 15-20
minutes. This allows the unit to warm and drain if there is any frost stopping
draining and go back to factory settings
For odour in a unit, we suggest using an algaecide tablet. You fi rst need to
turn the unit off, remove the lower grill and fi lter from the grill at the
base of the unit, and then place the tablet in base.
TROUBLESHOOTING
- Appliance will not operate
- Plug is not fully inserted into the wall outlet
- Blown fuse or circuit breaker
- Insufficient cooling
- Air filter is dirty
- Blocked air fl ow
- Appliance size is too small for application
- Noise
- The ground is not level
- The air filter is dirty or blocked
- Gurgling sounds are normal, this is coolant moving inside the appliance
- Odors
- Formation of mold or mildew on internal wet surfaces
]Place an algaecide tablet in the base pan; ensure the appliance is unplugged, remove the upper grille and filter, place the tablet in the middle water tray and replace the grille and filter
- Formation of mold or mildew on internal wet surfaces
LIMITED “IN HOME” WITED IN-HOME APPLIANCEARRANTYWALIM RRANTY
This quality product is warranted to be free from manufacturer’s defects in material and workmanship, provided that the unit is used under the normal operating conditions intended by the manufacturer. This warranty is available only to the person to whom the unit was originally sold by Danby Products Limited (Canada) or Danby Products Inc. (U.S.A.) (hereafter “Danby”) or by an authorized distributor of Danby, and is non-transferable.
TERMS OF WARRANTY
Plastic parts are warranted for thirty (30) days from the date of purchase,
with no extensions provided.
- First 24 months During the first twenty four (24) months, any functional parts of this product found to be defective, will be repaired or replaced, at warrantor’s option, at no charge to the original purchaser.
- To obtain service Contact the dealer where the unit was purchased, or contact the nearest authorized Danby service depot, where service must be performed by a qualified service technician. If service is performed on the unit by anyone other than an authorized service depot, all obligations of Danby under this warranty shall be void.
- Boundaries of in-home service Danby reserves the right to limit the boundaries of “In Home Service” to the proximity of an authorized service depot. Any appliance requiring service outside the limited boundaries of “In Home Service”, will be the consumer’s responsibility to transport at their own expense to the original point of purchase or a service depot for repair. If the appliance is installed in a location that is 100 kilometers (62 miles) or more from the nearest service center, it must be delivered to the nearest authorized
- Danby Service Depo t by the purchaser. Transportation charges to and from the service location are not protected by this warranty and are the responsibility of the purchaser.
Nothing within this warranty shall imply that Danby will be responsible or liable for any spoilage or damage to food or other contents of this appliance, whether due to any defect of the appliance, or its use, whether proper or improper.
EXCLUSIONS
Save as herein provided, by Danby, there are no other warranties,
conditions, representations or guarantees, express or implied, made or
intended by Danby or its authorized distributors and all other warranties,
conditions, representations or guarantees, including any warranties,
conditions, representations or guarantees under any Sale of Goods Act or like
legislation or statute is hereby expressly excluded. Save as herein provided,
Danby shall not be responsible for any damages to persons or property,
including the unit itself, howsoever caused or any consequential damages
arising from the malfunction of the unit and by the purchase of the unit, the
purchaser does hereby agree to indemnity and hold harmless Danby from any
claim for damages to persons or property caused by the unit
GENERAL PROVISIONS
No warranty or insurance herein contained or set out shall apply when damage
or repair is caused by any of the following:
- Power failure.
- Damage in transit or when moving the appliance.
- Improper power supply such as low voltage, defective house wiring or inadequate fuses.
- Accident, alteration, abuse or misuse of the appliance such as inadequate air circulation in the room or abnormal operating conditions (ie. extremely high or low room temperature).
- Use for commercial or industrial purposes (ie. If the appliance is not installed in a domestic residence).
- Fire, water damage, theft, war, riot, hostility, acts of God such as hurricanes, floods etc.
- Service calls resulting in customer education.
- Improper Installation (ie. Building-in of a free standing appliance or using an appliance outdoors that is not approved for outdoor application, including but not limited to: garages, patios, porches or anywhere that is not properly insulated or climate controlled).
Proof of purchase date will be required for warranty claims; retain bills of sale. In the event that warranty service is required, present the proof of purchase to our authorized service depot.
Warranty Service In Home
Danby Products Limited
PO Box 1778, Guelph, Ontario, Canada N1H 6Z9
Telephone: 519-837-0920 FAX:
519-837-0449
References
- Danby® the Appliance Specialists | Canada
- Danby® the Appliance Specialists | Canada
- Danby® the Appliance Specialists | Canada
- Customer Support | Danby Canada
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>