3M 9205+ Workplace Occupational Respirator User Guide
- June 13, 2024
- 3M
Table of Contents
3M 9205+ Workplace Occupational Respirator
USING INSTRUCTION
Always read and follow all user instructions.
For additional information to help you select appropriate 3M™ Respirators for your workplace, including a list of applicable airborne contaminants, please visit: 3M.com/respiratorselector
POTENTIAL APPLICATIONS
| Disposable Respirators| Disposable Respirators with Cool Flow
™ Valve| Reusable Respirators
---|---|---|---
N95| N95| R95
Nuisance Level Acid Gas Odor1 Relief
| R95
Nuisance Level Organic Vapor
Odor1 Relief
| N95| P95
Nuisance Organic Vapor Odor1 Relief
| N100
Lead
| OV/P95| 0V/P95
Full Face
| P100
Lead & Mold Nuisance Organic Vapor Odor1 Relief
| P100
Lead Paint
| OV/P100| OV/AG/P100
Products
| | | | | | | | | | | |
WOODWORKING
Painting| | | | Nuisance Level Odor1| | | | X| X| | | X| X
Sanding, Sawing, Lathing, Routing, Drilling| X| X| X| X| X| X| X| X|
X| X| X| X| X
Varnish, Staining| | | | Nuisance Level Odor1| | Nuisance Level Odor1| |
X| X| Nuisance Level Odor1| | X| X
Certain Cleaning Solvents
(like paint thinner and mineral spirits)
| | | | Nuisance Level Odor1| | Nuisance Level Odor1| | X| X| Nuisance Level
Odor1| | X| X
Glues| | | | Nuisance Level Odor1| | Nuisance Level Odor1| | X| X|
Nuisance Level Odor1| | X| X
CUSTODIAL
Dust from Basement, Garage, etc.| X| X| X| X| X| X| X| X| X| X| X| X| X
Fireplace Cleaning| | | | X| | X| | X| X| X| | X| X
Cleaners – Bleach| | | Nuisance Level Odor1| | | | | | | | | | X
Window Cleaner, Floor Cleaner (solvent-based only)| | | | Nuisance
Level Odor1| | Nuisance Level Odor1| | X| X| Nuisance Level Odor1| | X| X
Sweeping, Vacuuming| X| X| X| X| X| X| X| X| X| X| X| X| X
Pool/Hot Tub Cleaning, Chlorinated Materials| | | | | | | | | | | | |
X
Rust Removal with Acid-based Solution| | | | | | | | | | | | | X
ABATEMENT
Mold Removal – Dry Removal 2| X| X| X| X| X| X| X| X| X| X| X| X| X
Mold Removal – Bleach 2| | | Nuisance Level Odor1| | | | | | | | | |
X
REMODELING AND REPAIR
Cement Mixing 3| | See www.OSHA.gov or Call
3M at 1-800-243-4630
Cutting or Sanding Sheetrock/ Drywall/Plaster 3| X| X| X| X| X|
X| X| X| X| X| X| X| X
Driveway Resealing| | | | Nuisance Level Odor1| | Nuisance Level Odor1|
| X| X| Nuisance Level Odor1| | X| X
Installing Fiberglass Insulation| X| X| X| X| X| X| X| X| X| X| X| X| X
Insulation (spray foam) 4| | | | | | | | X| X| | | X| X
Coatings (powder)| X| X| X| X| X| X| X| X| X| X| X| X| X
Cutting Brick/Pavers, Stone Dust, Brick Dust 3| | See
www.OSHA.gov or Call 3M at
1-800-243-4630
Metalworking, Welding, Soldering, Grinding, Torch Cutting| | | | | |
| | | | X| X| |
Concrete Polishing 3| | See www.OSHA.gov or
Call 3M at 1-800-243-4630
Sanding Wood, Plastic, Metal| X| X| X| X| X| X| X| X| X| X| X| X| X
GROUNDSKEEPING
Fertilizing (dry or certain sprays)| X| X| X| X| X| X| X| X| X| X| X| X|
X
Lawn Mowing, Grass Clippings, Leaf Blowing, Mulching Bark/Leaves| X|
X| X| X| X| X| X| X| X| X| X| X| X
Pesticides, Mixing and Applying| | Refer to Pesticide Product Label for
Respirator Guidance or call 3M at
1-800-243-4630
Garbage Composting| | | | Nuisance Level Odor1| | Nuisance Level Odor1|
| X| X| Nuisance Level Odor1| | X| X
Pollen| X| X| X| X| X| X| X| X| X| X| X| X| X
PAINTING
Latex Paint| | | | Nuisance Level Odor1| | Nuisance Level Odor1| | X| X|
Nuisance Level Odor1| | X| X
Oil-based Paints, Lacquers, Enamels| | | | Nuisance Level Odor1| |
Nuisance Level Odor1| | X| X| Nuisance Level Odor1| | X| X
Automotive Spray Paint 4| | | | | | | | X| X| | | X| X
Paint Spraying| | | | | | | | X| X| | | X| X
SPECIAL CONSIDERATIONS
Asbestos Removal, Lead-based Paint Removal, Cement Mixing 3 ,
Concrete Polishing 3 , Cutting Brick/Pavers 3 , Stone
Dust 3 , Brick Dust 3| | | See www.OSHA.gov
or call 3M at
1-800-243-4630| | | |
- For nuisance-level odors only. Nuisance level refers to concentrations not exceeding the OSHA PEL or applicable government occupational exposure limits, whichever is lower.
- For areas less than 100 sq./feet, follow EPA Guidelines for mold removal: epa.gov/mold
- See Silica Standard OSHA.gov
- Not for use with isocyanates in Canada
FOR THE US AND CANADA ONLY
Warning: Respirators help protect against certain airborne contaminants.
Before use, the wearer must read and understand the User Instructions provided
as a part of the product packaging. Follow all local regulations. In the
U.S.A., a written respiratory protection program must be implemented meeting
all the requirements of OSHA 29 CFR 1910.134, including training, fit testing,
and medical evaluation. In Canada, CSA standards Z94.4 requirements must be
met and/or requirements of the applicable jurisdiction, as appropriate. Misuse
may result in sickness or death. For correct use, consult the supervisor and
User Instructions, or call 3M Personal Safety Division (PSD) Technical Service
in the U.S.A. at 1-800-243-4630. In
Canada, call 1-800-267-4414.
© 3M 2021. All rights reserved. 3M and Cool Flow are trademarks of 3M.
Documents / Resources
| 3M
9205+ Workplace Occupational
Respirator
[pdf] User Guide
9205 Workplace Occupational Respirator, 9205, Workplace Occupational
Respirator, Occupational Respirator
---|---
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>