MULTIPLEX ULTIPLE 2100 FreshBlender EcoBlend Retrofit Instructions

June 13, 2024
MULTIPLEX

ULTIPLE 2100 FreshBlender EcoBlend Retrofit

Product Information

Part Number Description
WBL-95-207 INSTRUCTION ECOBLEND RETROFIT KIT
3547881 LOCKING CLIP, RED 1/4,PTC
WBL-96-110 1/4 TUBE OD UNION ELBOW
WBL-96-141 BLENDER SHAFT NOZZLE, CLEAR
WBL-96-142 BLENDER BLADE NOZZLE, CLEAR
WBL-96-143 BLENDER BLADE NOZZLE WING NUT
WBL-96-144 DISPENSE DRAIN NOZZLE, CLEAR
WBL-96-145 BLENDER BLADE NOZZLE GASKET
WBL-96-146 CUP HOLDER, CLEAR
WBL-96-147 O-RING QUATTRO SEAL #013 .426 ID X .566 OD .07 THK BLK
WBL-94-065 CUP HOLDER BUSHING .5 OD X .26 ID LDPE BLK

Product Usage Instructions

  1. Ensure that the refrigeration cabinet door is closed to keep
    the product chilled while the unit is off.

  2. Power off and unplug the unit, then unlock the door.

  3. Remove the left and right side panels and the splash
    guard.

  4. Remove the drink shuttle and shuttle rail.

  5. Disconnect the ribbon cable from the Auxiliary Board and push
    it aside.

  6. Wear cut-resistant gloves when installing the blender shaft as
    it has sharp blades. Remove the blender shaft.

  7. From the blend chamber side of the unit, unscrew the cup holder
    rods one at a time until they are removed from the cup holder. Be
    careful not to damage the shaft with the spring attached. Remove
    the old cup holder.

  8. Locate the three cup holder guide rods near the blender motor.
    Unhook one end of each of the two springs from the two closest
    rods, leaving the spring attached to the rod furthest away.

  9. Locate three bushings.

  10. Lift each cup holder rod and install one bushing on each rod,
    ensuring that the bushing is installed below the blender motor
    plate. You can prop up the blender motor plate using the end of a
    universal screwdriver for assistance.

  11. Loosen the three cup holder rods. Pliers can be used at the top
    of the rods if needed.

  12. Install the new cup holder by screwing in each rod by hand. For
    the rod with the spring still attached, screw counter-clockwise
    several turns, place the screw into the top of the cup holder, and
    slowly release the rod so that it self-screws from spring tension.
    Ensure that all rods have been screwed into the cup holder
    completely.

  13. Carefully install the blender shaft, ensuring that it is not
    cross-threaded. If any resistance occurs while tightening the
    shaft, it means that the shaft is not seated properly. You may need
    to disconnect the farthest John Guest Fitting from the water line
    to get the fitting over the stem. The access hole in front of the
    unit can be used to remove the retaining clip and fitting.

  14. Reattach the springs to the cup holder rods.

  15. Remove any items used to hold the blender motor plate up.

Instruction Sheet

MULTIPLEX 2100 FUTURE DRIVE, SELLERSBURG, IN 47172
800-689-0157 OR 844-724-CARE WWW.MULTIPLEXBEVERAGE.COM
Refreshing the Experience
Subject: FreshBlender EcoBlend Retrofit
SCOPE: ALL MULTIPLEX FRESHBLENDERS

TOOLS REQUIRED · Pliers (needle nose and regular) · Universal Screwdriver · Ratchet, 9/16″ or metric 14 (short handle recommended) · Gloves (cut resistant) · Clean Towels

PARTS REQUIRED

· WBL-40-002 EcoBlend Kit (kit parts listed below)

QTY

DESCRIPTION

1 INSTRUCTION ECOBLEND RETROFIT KIT

5 LOCKING CLIP, RED 1/4,PTC

1 1/4″ TUBE OD UNION ELBOW

1 BLENDER SHAFT NOZZLE, CLEAR

1 BLENDER BLADE NOZZLE, CLEAR

1 BLENDER BLADE NOZZLE WING NUT

1 DISPENSE DRAIN NOZZLE, CLEAR

1 BLENDER BLADE NOZZLE GASKET

1 CUP HOLDER, CLEAR

1 O-RING QUATTRO SEAL #013 .426 ID X .566 OD .07 THK BLK
3 CUP HOLDER BUSHING .5 OD X .26 ID

LDPE BLK

PART NUMBER WBL-95-207 3547881 WBL-96-110 WBL-96-141 WBL-96-142 WBL-96-143 WBL-96-144 WBL-96-145 WBL-96-146 WBL-96-147
WBL-94-065

I mportant
Keep refrigeration cabinet door closed so product remains chilled while unit is off.

PREPARATION 1. Power unit OFF and unplug, then unlock door.
2. Remove left and right side panels, then remove splash guard.
3. Remove drink shuttle and shuttle rail.
4. Disconnect ribbon cable from Auxiliary Board and gently push aside so it is out of the way.

1 of 5 Document Number: WBL-95-207 11/22/2021

CUP HOLDER

, CAUTION

Blender shaft has sharp blades. Wear cut resistant gloves when installing blender shaft.

5. Remove blender shaft.

Subject: FreshBlender EcoBlend Retrofit
8. From blend chamber side of unit, unscrew cup holder rods one at a time until removed from cup holder. Be careful not to damage shaft with spring attached. Remove old cup holder.

6. Locate the three (3) cup holder guide rods near the blender motor. On the two closest rods, unhook one end on each of the two springs. Leave spring attached to rod furthest away.

9. Locate three (3) bushings.
10. Lift each cup holder rod and install one bushing on each rod. Make sure bushing is installed below the blender motor plate.

NOTE: It may be helpful to prop up the blender motor plate using end of universal screwdriver.
11. Locate new cup holder.

7. Loosen the three (3) cup holder rods. Pliers can be used at top of rods if needed.

12. Install new cup holder by screwing in each rod by hand. For the rod with spring still attached, screw counter
clockwise several turns, place screw into top of cup
holder and slowly release rod so rod self screws from spring tension. Make sure all rods have been screwed into cup holder completely.

2 of 5 Document Number: WBL-95-207 11/22/2021

Subject: FreshBlender EcoBlend Retrofit

, CAUTION
Blender shaft has sharp blades. Wear cut resistant gloves when installing blender shaft.
13. Carefully install blender shaft. DO NOT cross-thread. When tightening shaft, if any resistance occurs, the shaft is not seated properly.

NOTE: May need to disconnect farthest John Guest Fitting from water line to get fitting over stem. Access hole in front of unit can be used to remove the retaining clip and fitting.

14. Reattach springs to the cup holder rods.

18. Hold stem fitting inside unit with one hand and unscrew blender shaft rinse nozzle block with other hand. Set stem fitting and rinse nozzle block aside. Repeat for other blender shaft rinse block and stem fitting.

15. Remove screwdriver or any items used to hold blender motor plate up.
16. Plug unit in and power ON. NOTE: Watch to see that the cup holder and blender shaft move freely when unit cycles ON.
BLENDER SHAFT RINSE NOZZLE I mportant
Do NOT tug or pull on water lines.
17. Disconnect the two (2) John Guest fittings connecting blender shaft rinse nozzles from the rinse nozzle stems by removing bottom retaining clips

19. Locate new blender shaft rinse nozzle. 20. Place new rinse nozzle assembly stems into holes.

3 of 5 Document Number: WBL-95-207 11/22/2021

21. Push retaining clips over new rinse nozzle assembly stems to hold in place.

Subject: FreshBlender EcoBlend Retrofit
25. Clean basin if needed, then install new rinse nozzle from top of basin into hole and tighten plastic wing nut underneath basin. Make sure foam seal is on top side of basin

22. Reconnect both John Guest elbow fittings. Makes sure connections to water lines and new nozzle assembly
are secure to prevent leaks. Make sure to install red retaining clips.

26. Carefully pull fitting attached to water line out. Remove metal block fitting and replace with new John Guest elbow.

27. Connect new John Guest elbow to new rinse nozzle stem. Be careful not to damage plastic wing nut. Make sure to install red retaining clips.
BLENDER BLADE RINSE NOZZLE 23. Use 9/16″ or metric 14 ratchet to remove bottom rinse
nozzle, hold bottom fitting under basin while ratcheting. Do NOT damage basin.
BASIN RINSE NOZZLE 28. Disconnect John Guest fitting from outside left side
of basin.
24. Locate new rinse nozzle and John Guest elbow.

4 of 5 Document Number: WBL-95-207 11/22/2021

Subject: FreshBlender EcoBlend Retrofit 29. Remove old block nozzle and stem fitting.

33. Reconnect John Guest fitting to new nozzle. Make sure to install red retaining clips.

30. Remove any silicone in basin and clean area.
Silcone

31. Locate new rinse nozzle.

TOP

Reassembly
34. Power unit OFF. 35. Plug ribbon cable back in. 36. Replace drink shuttle and rail. 37. Power unit ON. 38. Make a drink and check for leaks around new connections. 39. Replace side panels. 40. Lock door.

32. Install new nozzle and connect retaining clip to outside of basin. Make sure o-ring is inside basin.

NOTE: New nozzle should be installed with thickest part of plastic at top so spray cutout faces down into basin.

5 of 5 Document Number: WBL-95-207 11/22/2021