EDiMAX EW-7889WAX Wireless Adapters Installation Guide
- June 13, 2024
- EDIMAX
Table of Contents
EW‐7889WAX
Quick Installation Guide
Product Specification
Main SPEC
Wireless Technology
| • IEEE 802.11b/g/n/ax 2.4GHz 1024QAM with 1200Mbpps
• IEEE 802.11a/n/ac/ax 5GHz 1024QAM with 2400Mbps
• SupportMU‐MIMO/OFDMA at 2.4GHz and 5GHz
---|---
External Interface
| • 1x 2.5GE LAN (802.3at POE)
• 1 x reset button
• 1 x MicroUSB Console Port(UART)
• 1 x USB
LED| • 1xtri‐color LED
PCB Dimension| • 210 188 1.6mm/6L
Enclosure Dimension| • 225225 43mm
Power supply
| POE 802.3at PD
Operating Temperature| 0℃~+40℃ / 10~90%RH
Key parts
CPU | Qualcomm IPQ8072A |
---|---|
Wi‐Fi 2.4GHz RF | Qualcomm QCN5024 |
Wi‐Fi 5GHz RF | Qualcomm QCN5054 |
SPI NOR Flash | • 8MB |
NAND Flash | • 512MB |
RAM | DDR4 1GB |
• 512MB DDR4*2
Wi‐Fi RF PA/FEM| 2.4GHz FEM:QPF4288A (Board data use QPF4228 for lower
power) 5GHz FEM:QPF4588A(Board data use QPF4528 for lower power)
antenna| 4x Dual band
PD IC| MP8009
Ethernet| QCA8081
Console| Prolific PL2303G4ZJG8P2
TPM| Infineon SLB 9670VQ2.0
Internal connector| M.2 Connector
Housing design & dimension:
LED definition
Description (For Alpha/Beta/Charlie/Delta) | LED |
---|---|
AP is off or reboot started | Off |
Normal Operation | Solid Green |
AP is booting & connecting to wireless controller | Flashing Green |
Error, no wireless controller found. AP will reboot (if not yet claimed by a
controller). Check network connection if error persists.
If reset button pressed: AP preparing configuration rese| ****
Solid Red
Configuration reset in progress | Flashing Slow Red
Firmware update in progress
Note: Do not disconnect from power
| Flashing Fast Red
AP has no connection to the wireless controller| Solid Amber
AP is not claimed by wireless controller| Flashing Amber
Safety Instructions
You can operate the access point (AP) safely if you follow the information in
these Safety Instructions and on the appliance.
Do not reach into the appliance. There are dangerous circuits inside the
appliance that can cause death if you touch them.
Damaged appliances must be returned. It is forbidden to open the hardware
appliance or to change its components. Failure to comply with this rule
results in the loss of warranty cover from EDIMAX.
Connect the device to a power socket with a fully functional earth conductor.
Defective earth conductor connections do not comply with the requirements for
safety and electromagnetic compatibility. Check the power socket before
connecting the hardware appliance.
The socket-outlet shall be installed near the equipment and shall be easily
accessible.
Before you switch on the appliance make sure that your mains voltage complies
with the supply voltage of the appliance. The connection data are shown on the
name plate.
To disconnect the appliance completely take the power cable from the power
socket. Make sure that the power plug is freely accessible.
Make sure that no one can trip over the power cable and that it cannot be
damaged by objects.
Only connect system peripherals complying with the requirements for protective
extra-low voltage according to EN/IEC 62368-1.
Only use parts and accessories validated by EDIMAX. Using non-approved parts
and accessories may affect the functioning of the appliance and your safety.
The appliance produces heat. Ensure that there is sufficient air circulation
to remove the heat.
Avoid a permanent high level of air humidity and formation of condensation.
Protect the appliance from humidity and chemicals. Safe use of the appliance
is no longer possible if: the chassis is damaged water penetrated the
appliance objects entered the appliance via air opening smoke comes out of the
appliance the power cable is damaged it does not work properly
Immediately turn off the appliance in the event of one of the above problems,
remove the power cable from the power socket and contact your customer service
as soon as possible.
We expressly exclude any product liability and warranty claims if the
appliance is not operated according to the instructions in these notes and to
the notes attached to the appliance itself.
PoE-Injector Safety Information
Caution: The PoE injector is to be connected only to PoE networks without
routing to the outside plant.
The power cord must be a three-conductor type (two current carrying
conductors; one ground conductor terminated on one end by an IEC 60320
appliance coupler (for connection to the PoE-Injector), and on the other end
by a plug containing a ground (earthing) contact).
The power cord must be razed for a minimum of 250 VAC RMS operation, with a
minimum rated current capacity of 5 A (or a minimum wire gauge of 18 AWG (0.75
mm2)).
A PoE-Injector installed in Australia requires power cords with a minimum wire
gauge of 16 AWG (1.0 mm2).
The PoE-Injector “Data In” and “Data & Power Out” ports are shielded RJ45 data
sockets. They cannot be used as Plain Old Telephone Service (POTS) telephone
sockets. Connect RJ45 data connectors only to those sockets.
The AC wall socket-outlet must be near the PoE-Injector and easily accessible.
You can remove AC power from the PoE-Injector by disconnecting the AC power
cord from either the wall socket-outlet or the PoE-Injector appliance coupler.
The PoE-Injector “Data In” and “Data & Power Out” interfaces are qualified as
Safety Extra-Low Voltage (SELV) circuits according to IEC 62368-1. Connect
these interfaces only to SELV interfaces on other equipment.
Warnings
Connect the PoE-Injector only to the IP device with which it was bought. Using
the PoE-Injector with other IP devices can cause damage to the IP device.
Read the installation instructions before connecting the PoE-Injector to its
power source.
Follow basic electricity safety measures whenever connecting the PoE-Injector
to its power source.
A voltage mismatch can cause equipment damage and may pose a fire hazard. If
the voltage indicated on the label is different from the power outlet voltage,
do not connect the PoE-Injector to that power outlet.
Federal Communication Commission Interference Statement
This device complies with Part 15 of the FCC Rules. Operation is subject to
the following two conditions: (1) This device may not cause harmful
interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class
B digital device, pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and
on, the user is encouraged to try to correct the interference by one of the
following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
FCC Caution: Any changes or modifications not expressly approved by the party
responsible for compliance could void the user’s authority to operate this
equipment.
This transmitter must not be co-located or operating in conjunction with any
other antenna or transmitter.
This device meets all the other requirements specified in Part 15E, Section
15.407 of the FCC Rules.
Radiation Exposure Statement:
This equipment complies with FCC radiation exposure limits set forth for an
uncontrolled environment. This equipment should be installed and operated with
minimum distance 49cm between the radiator & your body.
Note: The country code selection is for non-US model only and is not
available to all US model.
Per FCC regulation, all WiFi product marketed in US must fixed to US operation
channels only.
FCC regulations restrict the operation of this device to indoor use only.
Industry Canada statement
This device contains licence-exempt transmitter(s)/receiver(s) that comply
with Innovation, Science and Economic Development Canada’s licence-exempt
RSS(s). Operation is subject to the following two conditions:
- This device may not cause interference.
- This device must accept any interference, including interference that may cause undesired operation of the device.
Operation shall be limited to indoor use only;
Radiation Exposure Statement
This equipment complies with ISED radiation exposure limits set forth for an
uncontrolled environment. This equipment should be installed and operated with
greater than 30cm between the radiator & your body.
RED Compliance Statement
Compliance with 2014/53/EU Radio Equipment Directive (RED)
In accordance with Article 10.8(a) and 10.8(b) of the RED, the following table
provides information on the frequency bands used and the maximum RF transmit
power of the product for sale in the EU:
Frequency Range (MHz) | Max. Transmit Power (dBm) EIRP |
---|---|
2412 ~ 2472 | 19.96 dBm |
5180 ~ 5240 | 22.95 dBm |
5250 ~ 5320 | 22.93 dBm |
--- | --- |
5500 ~ 5700 | 29.99 dBm |
This equipment should be installed and operated with minimum distance 20cm between the radiator & your body.
| AT| BE| BG| HR| CY| CZ| DK
---|---|---|---|---|---|---|---
EE| FI| FR| DE| EL| HU| IE
IT| LV| LT| LU| MT| NL| PL
PT| RO| SK| SI| ES| SE| UK(NI)
This device is restricted to indoor use
Edimax Technology Co., Ltd.
No. 278, Xinhu 1st Rd., Neihu Dist., Taipei City, Taiwan
Email: support@edimax.com.tw
Edimax Technology Europe B.V.
Fijenhof 2, 5652 AE Eindhoven, The Netherlands
Email: support@edimax.nl
Edimax Computer Company
530 Technology Drive Suite 100, Irvine, CA 92618, USA
Email: support@edimax.us
Read User Manual Online (PDF format)