RAB Post Top Serise Light Instructions

June 4, 2024
RAB

RAB Post Top Serise Light

RAB Lighting is committed to creating high-quality affordable well-designed and energy-efficient LED Lighting and controls that make 1t easy for electricians to install and end users to save energy Wed love to hear your comments Please call the Marketing Department at 888-RAB-1000 or email: [email protected]

  • HIDFA-XXS-E26-8CCT-BYP/3SP
  • HIDFA-XXXS-EX39-8CCT-BYP/3SP

Our sensor product numbers include MW-S/SMW-5, PIR-5/SPIR-S and DAYLIGHT-5 are optional accessories for select Post Top lamps. The lamps will perform as normal if no sensor is inserted. Please note that RAB lamps can’t operate with other brand sensors.

IMPORTANT

READ CAREFULLY BEFORE INSTALLING LED HID BULBS. RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE, RAB LED HID Bulbs must be wired in accordance with the National Electrical Code and all applicable codes. Proper grounding is required for safety. THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE BY A PERSON FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED.

WARNINGS

  • Main applications include for use in post top, street lights and other suitable light fixtures.
  • Operating temperature:-30°C to 60°C (-22°F to 140°F).
  • These LED Lamps require all ballasts, capacitors, and ignitors to be bypassed or removed. Do not operate lamps on existing ballasts.
  • Dimmable with optional control modules.
  • Do not use with standard dimmers. Only use the control provided with or specified by these instructions to control this lamp. This lamp will not operate properly when connected to a standard( incandescent) dimmer or dimming control.
  • This device is not intended for use with emergency exits.
  • Can be used in enclosed fixtures. Do not install 120W in horizontal applications.
  • Before installation make certain the AC power to the fixture is off.
  • Risk of fire or electric shock. Luminaire wiring and electrical parts may be damaged when drilling for the installation of an LED retrofit kit. Check for enclosed wiring and components.
  • Risk of fire or electric shock. LED Retrofit lamp installation requires knowledge of luminaire electrical systems. If not qualified, do not attempt installation. Contact a qualified electrician.
  • Do not make or alter any open holes in an enclosure of wiring or electrical components during kit installation.
  • Installers should not disconnect existing wires from lamp holder terminals to make new connections at lampholder terminals. Instead, installers should cut existing lamp holder leads away from the lamp holder and make new electrical connections to lamp holder lead wires by employing applicable connectors.
  • To prevent wiring damage or abrasion, do not expose wiring to edges of sheet metal or other sharp objects.
  • Risk of fire or electric shock. Install this kit only in luminaires that have the construction features and dimensions shown in the photographs or drawings and where the input rating of the retrofit kit does not exceed the input rating of the luminaire.
  • Use only with a portable luminaire that is provided with shade.
  • The added weight of the device may cause instability of a free-standing portable luminaire.
  • Text or diagram showing how the supply connections are made to the lamp holders.
  • Risk of fire or electric shock. Install this kit only in luminaires that have the construction features and dimensions shown in the photographs and/or drawings and where the input rating of the retrofit kit does not exceed the input rating of the luminaire.
  • RISK OF FIRE OR ELECTRIC SHOCK. LUMINAIRE WIRING, POWER SUPPLY, OR OTHER ELECTRICAL PARTS MAY BE DAMAGED WHEN DRILLING FOR THE INSTALLATION OF RETROFIT KIT HARDWARE. INSPECT WIRING AND COMPONENTS FOR DAMAGE.
  • THE RETROFIT KIT IS ACCEPTED AS A COMPONENT OF A LUMINAIRE WHERE THE SUITABILITY OF THE COMBINATION SHALL BE DETERMINED BY AUTHORITIES HAVING JURISDICTION. THE PRODUCT MUST BE INSTALLED BY A QUALIFIED ELECTRICIAN IN ACCORDANCE WITH THE APPLICABLE AND APPROPRIATE ELECTRICAL CODES. THE INSTALLATION GUIDE DOES NOT SUPERSEDE LOCAL OR NATIONAL REGULATIONS FOR ELECTRICAL INSTALLATIONS.

FCC STATEMENT

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation, This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

LAMP INSTALLATION

  1. Turn off the power before installation. Remove old ballast or disconnect from the existing lamp holder. Remove and dispose of ballast in the correct manner. 5hown as Figure 1. (North America 100-277VAC)
  2. Reconnect directly to the existing lampholder. Shown as in Figure 2. (North America 100-277VAC.
  3. Select power and CCT of the new LED replacement lamp before installation.
  4. Install new LED replacement lamp. Shown as in Figure 3. Please make sure the old fitting is correctly earth. Attach the retrofit label to the luminaire.(North America 100-277VAC)

Securely fasten the earth fly lead cable to the main body structure. If the cable is damaged in any way please replace it. (Do not use existing but out cables) The cable if needs replacement must be 1.0mm in size and insulated from heat.

SELECTABILITY

Power and CCT Selectable

RAB-Post-Top-Serise-Light-FIG-1

INSTRUCTIONS

POST TOP SERIES

Model Number Power Selectable CCT Selectable

HIDFA-36S-E26-BCCT-BYP/3SP HIDFA-36S-EX39-BCCT-BYP/3SP

| lBW| 3OOOK
27W| 4OOOK
36W| SOOOK

HIDFA 455-E26-8CCT-BYP / 3SP HIDFA-45S EX39 -BCCT-BYP / 3SP

| 27W| 3OOOK
36W| 4OOOK
45W| SOOOK
HIDFA-54S-E26-BCCT-8YP / 3SP HIDFA 54S EX39 BCCT BYP / lSP| 36W| 3000K
45W| 4000K
54W| SOOOK
Model Number| Power Selectable| CCT Selectable
---|---|---

HIDFA-63S-EX39-BCCT-BYP / 3SP

| 45W| 3OOOK
54W| 4OOOK
63W| SOOOK

HIDFA-805-EX39-8CCT-8YP / 3SP

| 54W| 3OOOK
63W| 4000K
BOW| SOOOK

HIDFA-1OOS-EX39-BCCT-BYP / 3SP

| 63W| 3000K
BOW| 4000K
100W| SOOOK

HIDFA-120S-EX39-8CCT-BYP / 3SP

| BOW| 3000K
100W| 4000K
120W| SOOOK

SAFETY CABLE INSTALLATION INSTRUCTION

WARNING: You must use the safety cable to tighten the lamps equal to or over 80W in case of falling down due to old sockets.

RAB-Post-Top-Serise-Light-FIG-3

RAB WARRANTY

CONTACTS

Free Lighting Layouts Answered online or by request.

2021 RAB LIGHTING Inc.

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

RAB User Manuals

Related Manuals