nuura Sasi Small Designer Wall Lamp Instruction Manual

June 13, 2024
nuura

nuura Sasi Small Designer Wall Lamp

nuura-Sasi-Small-Designer-Wall-Lamp-product

Product Information

  • Product Name: Sasi Small
  • Fitting: Integrated LED
  • Manufacturer: Nuura
  • Contact Information: info@nuura.com
  • Website: www.nuura.com
  • All Rights Reserved: 2022

Product Usage Instructions

  1. Before starting the installation, ensure that the main cable is disconnected from the power supply. This can be done by removing the fuse or turning off the switch.
  2. Follow the local safety regulations while carrying out the installation.
  3. Prior to drilling holes, check the walls for any cables to prevent damage.
  4. Ensure that all electrical connections, including preassembled lamps, are tightly screwed or fully inserted to establish good contact. Check for tight connections after changing or adjusting lamps. Screwed connections must be tightened after 20 minutes.
  5. Avoid placing objects on the system for decorative purposes unless they were delivered with the system.
  6. Allow the lamps to cool down before touching as they become very hot when in use.
  7. Do not change the light source while it is switched on.
  8. Do not enlarge the system with additional lamps.
  9. Use a compatible dimmer for optimal performance. The dimmer must be compatible with the type of bulb used.
  10. For brass versions, note that color fading may occur when exposed to direct sunlight. Therefore, it is not recommended to mount the lamp under a rooftop window or similar.
  11. If the external flexible cable or cord of the luminaire is damaged, it should be replaced exclusively by the manufacturer, their service agent, or a qualified person to avoid hazards.
  12. The manufacturer reserves the right to make technical alterations to the product.

Assembly Instructions

  1. Mounting Hole Dimensions: 171 mm
  2. Push the power cable through the rubber plug. Place the lamp base flush to the mounting surface.
  3. If surface-mounted cable is desired, use the alternative cable opening at the bottom and provide strain relief.
  4. Mount the lamp to the wall or ceiling using screws. Ensure appropriate rawlplugs/anchors are used for your construction. Make sure the base is properly fixated.
  5. Remove the lid from the driver on the power input side. Connect the power cable to the terminals, matching the brown wire with ‘L’ and the blue wire with ‘N’. Reattach the lid to the driver.
  6. Connect the plug from the driver to the connector on the LED module.
  7. Attach the diffuser and LED module to the lamp by placing it into the shade and tightening the 4 screws on the sides of the lamp.

Safety instructions

Important!
Before commencing installation work disconnect the main cable from the power supply – remove fuse or turn switch to “OFF”!

  1. Installation should be carried out in accordance with the local safety regulations.
  2. In order to prevent damage, please check walls for cables before drilling holes.
  3. Please ensure that all electrical connections (even preassembled lamps) are screwed tightly or are fully inserted as good contact is essential for a long life-span at high currents. Please check for tight connections after changing or adjusting lamps. Screwed connections must be tightened after 20 minutes.
  4. Please do not place objects on your system (e.g. for decorative purposes) if they were not delivered with the system.
  5. The lamps get very hot when in use. Please allow lamps to cool down before touching.
  6. Do not change lightsource when switched on.
  7. System should not be enlarged with additional lamps.
  8. Use of a dimmer is highly recommended. Dimmer must be compatible with type of bulb.
  9. Notice that for brass versions, color fade when exposed to direct sunlight. Therefore it is not recommended to mount the lamp under a rooftop window etc.
  10. If the external flexible cable or cord of this luminaire is damaged, it shall be exclusively replaced by the manufacturer or his service agent or a similar qualified person in order to avoid a hazard.
  11. We reserve the right to make technical alterations.

Please keep these instructions.

  • Fitting: Integrated LED

Installation

  1. Mounting hole dimensions.

  2. Push power cable through rubber plug. Place lamp base flush to the mounting surface.
    Note: If surface mounted cable is desired use alternative cable opening in bottom and strain relief.

  3. Mount the lamp to the wall or ceiling with screws. Make sure to use appropiate rawlplugs/anchors for your construction. Please make sure the base is fixated properly.

  4. Remove the lid from driver on the power in side. Connect the power cable to the terminals. Match the brown wire with “L” the blue wire with “N”. Reattach the lid to the driver.

  5. Connect the plug from the driver to the connector on the LED-module.

  6. Attach the diffuser and LED-module to the lamp by placing it into the shade and tightening the 4 screws on the sides of the lamp.