eta 2630 Fainer Air Dehumidifier Instructions

June 13, 2024
ETA

eta LOGOeta Fainer LOGO Air dehumidifier
INSTRUCTIONS FOR USEeta 2630 Fainer Air Dehumidifier

2630 Fainer Air Dehumidifier

eta 2630 Fainer Air Dehumidifier - FIGURE 1eta
2630 Fainer Air Dehumidifier - FIGURE 2The pictures are only illustrative

INSTRUCTIONS FOR USE
Dear customer, thank you for buying our product. Before putting the appliance into operation, read carefully these instructions for use and store this manual properly together with the certificate of warranty, a cash voucher and possibly with the package and the internal contents of the package. The appliance is designed for moderate climate.

SAFETY WARNING

Caution, risk of fire
GENERAL PROVISIONS:

  • Consider the instructions for use as a part of the appliance and pass them on to any other user of the appliance.
  • Check whether the data on the type label corresponds with the voltage in your socket. The power cord plug may only be connected to the electrical socket complying with the applicable standards.
  • This appliance may only be used by children aged 8 years or older, and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.
  • Before exchanging any accessories or accessible parts, before assembly and disassembly, before cleaning and maintenance or after finishing the work, switch off the appliance and disconnect it from mains by unplugging the power cord plug from the electrical socket!
  • ATTENTION: Do not use this heater in series with an external timer, remote controller or any other device that switches on the appliance automatically, since a fire risk exists when the heater is accidentally covered or displaced at the moment it switches on.
  • The appliance can be used continuously without any limitation on the operating time. However, for safety reasons, it is essential that an adult is always present in the household where the appliance is used.
  • The appliance must not be immersed into water or other liquids (even partially) and it must not be used in close proximity of bathtubs, showers, wash basins or other water containers, including a swimming pool. If the appliance falls into water, do not take it out! First of all unplug the power cord from the socket and only then take out the fan. In this case take the appliance to a special service to check its safety and proper function.
  • The appliance cannot be used in bathrooms in zones 0, 1 and 2 (fig.3)! It must not be used in close proximity of bathtubs, a shower or a swimming pool.
  • Do not plug the power cord in the electrical socket and do not unplug it with wet hands or by pulling the power cord!
  • Do not modify the appliance surface in any manner (e.g. by self-adhesive wallpapers, foils, etc.)!
  • Never put fingers or other objects into inlet and outlet holes of the fan.
  • Do not touch aluminium fins.
  • WARNING: There is a risk of injury in case of incorrect use (not in accordance with the manual) of the appliance.
  • Only use this appliance for the purpose it was designed for, as specified in this manual. Never use the appliance for any other purpose.
  • The appliance must be installed in accordance with national regulations for installing; this appliance is mobile, transferrable, and it is not intended for the installation into the electric supply system.
  • Place the appliance at a distance at least 1 m from devices radiating electromagnetic field and under a window with a distance at least 30 cm from the rear and side walls.
  • When displacing, don’t tilt the appliance by more than 35° nor turn over it upside-down. And empty the condensate container before any manipulation. If the appliance was tilted more than 45°, let it stand in the vertical position for at least 24 hours before putting it into operation.
  • The appliance has to be installed, operated and stored in premises with the floor area more than 4 m².
  • Only authorized ETA service specialists are allowed to perform service.
  • The manufacturer assumes no responsibility for any damage caused by improper handling of the appliance and its accessories (e.g. electric shock, fire), and the appliance guarantee will become void if any of the aforementioned safety instructions are not observed.

USE OF THE APPLIANCE:

  • Use the appliance only when properly assembled (protective grid, condensation vessel, even if you are using the drain tube).
  • The appliance is intended for home use and similar (in shops, offices and similar workplaces, in hotels, motels and other residential environments, in facilities providing accommodation with breakfast). It is not intended for commercial use!
  • Do not place any objects on the top of the appliance.
  • This appliance is not intended for outdoor use.
  • Only use the appliance in the working position at places with no risk of overturning and in a sufficient distance from other objects (such as curtains, drapes, etc.), heat sources (e.g. fireplace, heater, stove, cooker, radiators, hot air ovens, grills) and wet surfaces (e. g. sinks, wash basins).
  • For the purpose of stability, the appliance must be placed on a flat and hard surface. It should not stand on a soft material.
  • Make sure that no impurities get inside the appliance (e.g. dust clouds, hairs etc.). If impurities are sucked and settle inside the appliance, clean it.
  • Do not place the appliance below/near electrical socket and other electrical appliances.
  • When handling the appliance, avoid causing any injury.
  • Do not place any device with open flame in the air flow coming out from the appliance because of danger of burning process interruption.
  • Never expose yourself (or animals) to the air flow for an extended period of time. It may cause health problems.
  • Only use original components designed for this type.
  • To maintain the maximum efficiency of the appliance and avoid overloading, do not use the dehumidifier in larger rooms than it is designed for.
  • Holes for air ventilation must not be covered.
  • The appliance is only intended for use with coolant R-290 (propane).
  • The cooling circuit is sealed. Technical service only be performed must by a qualified technician!
  • Do not release the coolant into the environment.
  • R-290 (propane) is flammable and heavier than air. It will collect lower, near the floor, but can be dispersed in the room by fans.
  • If propane is present or even suspected in the air, do not allow not properly trained persons to attempt to find the cause.
  • The gas used in the appliance is odourless. Absence of odour does not mean absence of gas leaks.
  • If a leak is detected, immediately evacuate all persons and properly ventilate the room (apartment). Ventilation must be intensive, with adequate duration.
  • Do not use open flames, cigarettes or other potential sources of ignition in the room or near the room.
  • Individual components are intended for use with propane and are non-flammable and non-sparking. These components can only be replaced by identical parts, authorized by the manufacturer.
  • The appliance has a protective feature (3-minutes time delay for the start of the compressor). Wait 3 minutes before resuming the operation of the appliance.

POWER CORD:

  • Never use the appliance if the power cord or power plug are damaged, if the appliance is not correctly operating or if it has fallen on the floor and been damaged, or if it has fallen into water. In such cases take the appliance to a professional service centre to verify its safety and correct function.
  • If the power cord of the appliance is corrupted, it has to be replaced by the manufacturer, its service technician or a similarly qualified person so as to prevent dangerous situations.
  • Never put the power cord on hot surfaces and never let it hang over table edge or worktop edge. If the cord is caught or pulled, e.g. by children, the appliance may overturn and fall down, causing a serious injury!
  • The power cord must not be damaged with sharp or hot objects, open fire, it must not be sunk into water or bent over sharp edges.
  • If you need to use an extension cord for justified reasons, it must be undamaged and comply with the applicable standards.

DESCRIPTION OF THE APPLIANCE (Fig. 1)

A – Appliance body
A1 – RH indication levels
A2 – Air outlet
A3 – Condensed water vessel
A4 – Water level indicator
A5 – Drain tube
A6 – Condenser water outlet
A7 – Air inlet protection grid
A8 – Relative humidity sensor (% RH)
A9 – Handle
A10 – Castors
A11 – Power supply cable
A12 – Water vessel cover
B – Control panel
B1 – On/Off switch
B2 – On/Off switch indicator lamp
B3 – Operation mode selection button
B4 – Operation mode indicator lamps
B5 – RH setting button
B6 – LED display
B7 – Timer
B8 – Timer indicator lamp
B9 – Fan speed selector button
B10 – Fans speed indicator lamp
B11 – Button lock
B12 – Button lock indicator lamp
B13 – Condensed water indicator lamp
C – Drain tube

PREPARATION FOR USE

Remove all the packing material and take out the appliance. Remove all possible adhesion foils, stick–on labels or paper from the appliance. Place the appliance on a suitable flat and dry surface. Leave free space for due ventilation. Vents in the appliance ensure air circulation during ventilation and they must not be covered or blocked in another way. Make sure that the power cord is not damaged and that it does not lead any sharp or hot surfaces. The electric socket must be easily accessible so that the appliance can be easily disconnected from power supply if danger appears.
INSTALLATION AND POSITION OF THE APPLIANCE
Place the appliance on a flat surface in a good ventilated room. Avoid direct sunshine, observe minimum distance of 30 cm from back and side walls or other obstacles.
Observe the instruction provided in the Safety section.
RH indication levels (RH = Relative humidity)
The appliance shows 3 basic colours indicating RH level.

Blue RH < 45%
Green 45 % ≤ RH ≤ 65 %
Red RH > 65 %

Remarks related to the functioning of the appliance

  • Functional principle of the appliance consists in circulation of air in the cooling circuit, where condensation of air humidity and its drainage into the condensed water tank occurs.
  • Compressor dehumidifiers are most efficient at higher ambient temperatures (approx. 30 °C). The lower ambient temperature, the lower dehumidification efficiency. In standard household, the appliance should be used at 22 – 25 °C or higher temperatures. Therefore, it is advisable to combine drying with air heating in the event of increased dehumidification requirements (e.g. using hot air fan, which will increase the temperature and, at the same time, air circulation intensity).
  • Optimum air humidity in summer ranges 40 – 55 %, in winter 45 – 60 %.

AUTOMATIC DEFROSTING „NO FROST“
The appliance has an automatic defrosting function which turns off the compressor during operation and activates the highest fan speed for 10 minutes. Indicator lamp B2 will be flashing in the defrosting mode. The following conditions are relevant for this function:
A. At ambient temperature <5 °C or >35 °C, the compressor stops and the fan will be switched off after 30 seconds.
B. At ambient temperature 5 – 35 °C:
– defrosting function will be activated at temperatures 5 – 10 °C and also continual compressor operation for 30 minutes.
– defrosting function will be activated at temperatures 11 – 18 °C and also continual compressor operation for 45 minutes
– At current temperatures > 18 °C, the compressor runs continuously, no defrosting occurs.
Remarks
– When defrosting is complete, the appliance will continue to operate as set.
– The defrosting process should not be interrupted! In case of interruption, the following shall apply:
– if the appliance will be switched off and on within 5 minutes, the defrosting process will be deactivated;
– if the appliance will be switched off (or if condensed water vessel A3 is full) and also after 5 minutes of the defrosting time, the defrosting process will be resumed, provided the appliance is switched on (or condensed water vessel A3 drained) within 30 minutes.

INSTRUCTIONS FOR USE

After connection to the mains, the appliance will be switched to stand by mode (sound signal will be issued and all indicator lamps, A1 indicator and the display will go on for a moment; then only indicator lamp B2 will remain lighting).
By pressing B1 in standby mode, the appliance will be turned on in automatic mode at high speed of the fan and set RH value of 50% (corresponding icons will light up on the control panel). At the same time, current RH value in the room will be displayed. Now you can change the modes and functions using the corresponding buttons, see below. For disabling any function and switching the appliance in stand by mode, press button B1 again. If the compressor is running, it will be stopped immediately, however, the fan continues running and it will be stopped after 30 seconds (time delay).
Remark

  • If the appliance is active, the control system will be switched to economy mode (indicator lamps will be dimmed) after several minutes. Press any button to disable the economy mode.
  • At hot days, the air outlet is warm at touching. This is normal.
  • The appliance will resume the recent operation mode set by the user. If the appliance is on and has been switched off by disconnecting power cable, stand by mode will be skipped and set program will be activated immediately.
  1. DEHUMIDIFICATION MODES
    The appliance has three basic dehumidification modes, they can be changed by pressing
    B3 in the following sequence: automatic> continual > sleep > automatic …
    a) Automatic mode (indicator lamp B4 is on )
    As soon as ambient RH value is ≥ than the RH value you have set (+ 3 %), the fan and the compressor will be activated. If subsequently RH value drops below/is equal to the RH value RH you have set (-3 %), the compressor will be switched off. The fan will be switched off after 30 seconds.
    (Setting fan speed and required humidity can be made).
    b) Continual mode (indicator lamp B4 is on )
    Continual dehumidification at the highest fan speed is active until this mode has not been deactivated A3 vessel has been filled.
    (Setting fan speed and required humidity level is not possible).
    c) Sleep mode (indicator lamp B4 is on )
    Fan speed will be adjusted to minimum, sound signal (including ‟water vessel full‟ signal) will be disabled; at the same time, indication A1 and fan indicator lamp B10 will be switched off by display B6 10 seconds after activation of this mode. Press any button to switch on the lamps and the display for a moment.
    Note:
    – The appliance will be switched off if ambient RH value is ≤ 57 %.
    – The appliance will be activated as soon as ambient RH value is ≥ 63 %.
    (Setting fan speed and required humidity level is not possible).

  2. SETTING REQUIRED HUMIDITY LEVEL
    Use button B5 to set individual RH value to be maintained in the room. Humidity setting range: 30 % – 35 % – 40 % – 45 % – 50 % – 55 % – 60 % – 65 % –70 % – 75 % – 80 %.
    As soon as the required value has been set, its value will flash on display several times and it will be confirmed after a while. Current RH value will be displayed and the setting will be stored.
    Remark
    Press long B5 to display room temperature for a couple of seconds.

  3. FAN BLOWING SPEED
    Two blowing speeds can be switched (low – high ), using B9. The relevant value is indicted by lighting up B10.
    (Can be changed in automatic mode).

  4. TIMER
    The timer has two basic functions: delayed start, delayed switching off. The function you have set will be indicated by B8. Use B7 for setting the relevant time delay, ranging 1-24 hours (in 1-hour intervals). Value ‟00“–the timer is disabled.
    A) Delayed switching off – can be set in active mode. After expiration of set period of time, the appliance will be switched to stand by mode.
    B) Delayed start – start of the appliance can be set in stand by mode. After expiration of set period of time (watch countdown on display), the appliance will be switched on. After switching on, the recent setting (stored in memory) will be activated.

  5. CHILD LOCK
    Press long B11 to lock all buttons. Press long B11 again to unlock all buttons.
    Active function will be indicted by lighting B12.

Draining condensed water
Condensed water collects in vessel A3. Its level is shown by indicator A4. As soon as the vessel is full, operation of the appliance will be interrupted, sound signal will be issued and indicator lamp B13 will light up. Switch off the appliance, drain condensed water through the hole in the corner of the water vessel cover A12, then put the vessel back to its place (water indicator lamp B13 must go out). Then switch on the appliance again and proceed the required activity.
If circumstances and location of the appliance permit, you can connect external drain tube C (fig. 1, steps 4 and 5) to the appliance and drain condensed water to a suitable tank/piping. Do not immerse the tube in water, condensed water must be allowed to drip freely.
Remark

  • If you use external drain tube, it must not be bent or elevated (risk of water flowing into the room).

  • The ambient temperature of the drain tube while used must not fall below zero C°.
    Drained water could freeze in the tube which could result in getting water into the appliance and resulting leakage into the room.

  • When removing the vessel during operation, sound signal will be heard and indicator lamp B13 will go on.

MAINTENANCE

Disconnect the appliance from mains before any maintenance. Wipe individual parts of the body and the control panel using damp cloth or sponge. Avoid water to enter into the appliance and/or control panel. Do not use any aggressive and/or abrasive cleaning agents. Rinse condensed water vessel A3 with clean water and allow to dry.
Filter
Remove the filter in grid A7 and clean it after approx. 100 hours of operation (or as required). The filter can be washed in warm water with added non- aggressive detergent or cleaned using vacuum cleaner. Allow to dry and return back to its place.
Accessories
Wipe the drain tube using damp cloth with added non-aggressive detergent. Rinse it in clean water and allow to dry.
Storage
Empty condensed water vessel A3 and clean it (incl. filter). Allow to dry all cleaned parts incl. the entire interior system of the appliance! Store the appliance in a dry, well-ventilated and safe place, out of the reach of children and unauthorized persons to avoid mechanical damage.
The appliance must be stored in a room without permanently functioning devices/power sources (e.g. open flame, functioning gas device or electric heating radiator).

ENVIRONMENT

If the dimensions allow, there are marks of materials used for production of packing, components and accessories as well as their recycling on all parts. The symbols specified on the product or in the accompanying documentation mean that the used electrical or electronic products must not be disposed of together with municipal waste. For proper disposal, hand them over at the special collection places where they will be accepted free of charge. Suitable disposal of the product can help to maintain valuable natural resources and to prevent possible negative impacts on the environment and human health, which could be the possible consequences of improper waste disposal. Ask for more details at the local authority or at a collection site. Fines can be imposed for improper disposal of this type of waste in agreement with the national regulations. If the appliance is to be put out of operation, after disconnecting it from power supply we recommend its cutoff and in this way it will not be possible to use the appliance again.

TROUBLESHOOTING

PROBLEM CAUSE REMEDY
The appliance does not work Incorrect connection Connect the appliance to

the mains.
Condensed water vessel is full| Drain condensed water vessel and return it back.
Ambient temperature < 5°C or > 35 °C| The appliance has protection against switching on in this temperature range
Non-standard functioning| Dirty filter or blocked air inlet/ outlet| Clean the filter and/or remove the obstacles
Excessive operation noise| Uneven surface| Place the appliance on an even surface
Dirty filter| Clean the filter
E2| Humidity sensor failure| Contact technical service
LO| Ambient humidity <20 %| The appliance does not function in these conditions. Wait until the humidity changes.
HI| Ambient humidity >90 %
CL| Ambient humidity je <5 °C
CH| Ambient humidity je >35 °C

TECHNICAL DATA

Operating temperature 5°C – 35°C
Capacity of dehumidification (I/h) 7 1/d (26,7 °C, RH 60 %)

12 l/d (30 °C, RH 80 %)
Electric input| 160 W/0,9 A (26,7 °C, RH 60 %)
185 W/1,0 A (30 °C, RH 80 %)
Condensate tank| 21
Voltage / frequency (V/Hz)| 220V-240V— / 50Hz
Noisiness (dB(A))| 36 db(A)
Weight (kg)| 11 kg
Dimensions (WxDxH); mm| unit 255 x 220 x 470 mm
package 300 x 265 x 520 mm
Coolant| R290
Maximum quantity of coolant| 55 g
Discharge Side Pressure| 3,2 Mpa
Suction Side Pressure| 0,7 Mpa
Effective for a room up to| 60 m2
Minimum Room size| 4 m2
Current fuse| 3,15A 250 V
Electric input in standby mode| < 0,50 W
Appliance with protection class| I.

The manufacturer reserves the right to change the technical specifications and accessories for the respective models.
Circuit diagram

eta 2630 Fainer Air Dehumidifier - Circuit diagram

WARNINGS AND SYMBOLS USED ON THE APPLIANCE, PACKAGING OR IN THE INSTRUCTIONS MANUAL:
DO NOT COVER. HOUSEHOLD USE ONLY. CAUTION: BE CAREFUL OF STEAM.
DO NOT IMMERSE IN WATER OR OTHER LIQUIDS.
TO AVOID DANGER OF SUFFOCATION, KEEP THIS PLASTIC BAG AWAY FROM BABIES AND CHILDREN. DO NOT USE THIS BAG IN CRIBS, BEDS, CARRIAGES OR PLAYPENS. THIS BAG IS NOT A TOY.
The symbol indicates a WARNING.

| CAUTION| This symbol means that flammable coolant is applied in this appliance.
In case of leakage of coolant and if this coolant is exposed to an extern ignition source, there is a threat of fire.
---|---|---
| ATTENTION| This symbol warns that it is necessary to read carefully the Operating Instructions Manual.
| ATTENTION| This symbol specifies that the personnel should manipulate with this appliance preferably after having consulted the installation manual.
| ATTENTION| This symbol specifies that the following information sources such as Operating Instructions Manual or Installation Manual are available.

Note: The product is also equipped with a Service Manual, which supplements some information from this manual and is intended for a qualified service.

eta LOGO © DATE 28/4/2023
e.č.21/2023

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

ETA User Manuals

Related Manuals