Product Information

  • Product Mode l: IB525002EN
  • Brand: Cooper Lighting Solutions

Warnings

  • Make certain power is OFF before starting installation or attempting any maintenance.
  • Risk of fire/electric shock. If not qualified, consult an electrician.
  • Do not mount luminaire within 6″ of a combustible surface.
  • Do not handle luminaire by the glass. Do not touch LEDs.

Notes

  • These instructions do not claim to cover all details or variations in the equipment, procedure, or process described, nor to provide directions for meeting every possible contingency during installation, operation or maintenance. When additional information is desired to satisfy a problem not covered sufficiently for user’s purpose, please contact your nearest representative.
  • Care must be taken not to set lighting fixture down on optical lenses or lift the fixture in the lens area.
  • Specifications and dimensions subject to change without notice.

Product Usage Instructions – Photocontrol Receptacle Supplement

Installation
Tools Required (Figures 2 – 3)

  • Flat head screwdriver.
  1. If your luminaire is equipped with a photocontrol receptacle, use the figures provided to identify your photocontrol receptacle and follow the instructions on that diagram and all applicable notes below.
    • Note: 3-PIN photocontrol receptacle cannot be used with the 7-PIN photocontrol.
    • Note: The orientation procedure is only required for photocontrols which specifically require the cell to be aimed North. Otherwise pre-selected factory orientation will function properly. Follow the directions recommended by the photocontrol supplier for proximity to light sources. Lighted signs, building surface reflection, floodlights, tree branches, etc. may affect final position of the photocontrol.
    • Note: The photocontrol (not included) must contain a soft, resilient gasket fastened to the bottom surface to assure a proper weather seal between the control and the receptacle.
    • Note: Do not loosen screws on 7-PIN tool-less receptacle. (Figure 1.)
    • Note: Once receptacle is in desired position, torque the two screws to 25 in-lbs. maximum. (Figure 2 – 3.)
  2. Loosen Screws and Rotate Receptacle to Desired Position (Figure 2 for 7-PIN)
  3. Insert Flat Head Screwdriver and Rotate Receptacle to Desired Position (Figure 1 for 7-PIN Tool-less)
  4. Rotate to Point Photocontrol in North Direction (Figure 3 for 3-PIN)

Installation Instructions – Photocontrol Receptacle Supplement

Instructions

WARNING
Make certain power is OFF before starting installation or attempting any maintenance.

WARNING
Risk of fire/electric shock. If not qualified, consult an electrician.

WARNING
Risk of Electric Shock – Disconnect power at fuse or circuit breaker before installing or servicing.

WARNING
Risk of Personal Injury – Fixture may become damaged and/or unstable if not installed properly.

  • Do not mount luminaire within 6” of a combustible surface.
  • Do not handle luminaire by the glass. Do not touch LEDs.

WARNING
Risk of Burn – Disconnect power and allow fixture to cool before servicing.

Note: These instructions do not claim to cover all details or variations in the equipment, procedure, or process described, nor to provide directions
for meeting every possible contingency during installation, operation or maintenance. When additional information is desired to satisfy a problem not covered sufficiently for user’s purpose, please contact your nearest representative.

Note: Care must be taken not to set lighting fixture down on optical lenses or lift the fixture in the lens area.
Note: Specifications and dimensions subject to change without notice.

IMPORTANT: Read carefully before installing fixture. Retain for future reference.

GENERAL: Upon receipt of the fixture, thoroughly inspect for any freight damage which should be brought to the attention of the delivery carrier. Compare the catalog description listed on the packing slip with the fixture label on the housing to assure you have received the correct material.

SAFETY: This fixture must be wired in accordance with the National Electrical Code and applicable local codes and ordinances. Proper grounding is required to insure personal safety. Carefully observe grounding procedure under installation section.

APPLICATIONS: This lighting fixture is designed for outdoor lighting services, and should not be used in area of limited ventilation or inside high ambient temperature enclosures. It must be stored in a dry location prior to installation. Do not expose lighting fixture to rain, dust or other environmental conditions prior to installation and insertion of photocontrol or shorting cap (if so equipped). Do not install the fixture near combustible materials or locate next to airflow
blocking surfaces within 6 inches. Best results will be obtained if installed and maintained according to the following recommendations.

Installation Instructions – Photocontrol Receptacle Supplement

INSTALLATION

Photocontrol – If Equipped
Tools Required (Figures 2 – 3.)
Flat head screwdriver.1. If your luminaire is equipped with a photocontrol receptacle, use the figures provided to identify your photocontrol receptacle and follow the instructions on that diagram and all applicable notes below.

Note: 3-PIN photocontrol receptacle cannot be used with the 7-PIN photocontrol .
Note: The orientation procedure is only required for photocontrols which specifically require the cell to be aimed North. Otherwise pre-selected factory orientation will function properly. Follow the directions recommended by the photocontrol supplier for proximity to light sources. Lighted signs, building surface reflection, floodlights, tree branches, etc. may affect final position of the photocontrol.
Note: The photocontrol (not included) must contain a soft, resilient gasket fastened to the bottom surface to assure a proper weather seal between the control and the receptacle.
Note: Do not loosen screws on 7-PIN tool-less receptacle. (Figure 1.)
Note: Once receptacle is in desired position, torque the two screws to 25 in-lbs. maximum. (Figure 2 – 3.)

Figure 1. ( 7-PIN Tool-less) Figure 2. (7-PIN)

Figure 3. (3-PIN)

Warranties and Limitation of Liability
Please refer to www.cooperlighting.com for our terms and conditions.

Cooper Lighting Solutions

Imprimé aux États-Unis
Impreso en los EE. UU. Publication No. IB525002EN July 04, 2016

Cooper Lighting Solutions is a registered trademark.

  • All trademarks are property
  • of their respective owners.
  • Cooper Lighting Solutions est une marque de commerce
  • Cooper Lighting Solutions

Product availability, specifications, and compliances are subject to change without notice.

Documents / Resources

| Lumark NFFLD-L Night Large Falcon Light [pdf] Instruction Manual
NFFLD-L Night Large Falcon Light, NFFLD-L, Night Large Falcon Light, Large Falcon Light, Falcon Light, Light
---|---

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals