MITSUBISHI ELECTRIC MSZ-AP60VG Split Type Air Conditioners Instruction Manual
- June 13, 2024
- Mitsubishi Electric
Table of Contents
- MSZ-AP60VG Split Type Air Conditioners
- Product Information
- Product Usage Instructions
- SAFETY PRECAUTIONS
- SAFETY PRECAUTIONS
- For installation
- For Wi-Fi interface
- DISPOSAL
- NAME OF EACH PART
- PREPARATION BEFORE OPERATION
- PREPARATION BEFORE OPERATION
- TIME, TIMER set button
- CLEANING
- SPECIFICATIONS
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
MSZ-AP60VG Split Type Air Conditioners
Product Information
- Product Name: Split-Type Air Conditioners
- Indoor Unit Models: MSZ-AP60VG, MSZ-AP71VG, MSZ-AP60VGK, MSZ-AP71VGK
- Languages Available: Polski, Norsk, Suomi, Cestina, Slovencina, Magyar, Lietuviskai, Hrvatski, Srpski, EN, NL, EL, BG, SL, RO, LV, LT, HR, SR
- Manual Download Link: http://www.mitsubishielectric.com/ldg/ibim/
This manual is a brief version. Visit the above website and choose a language to download the full version of the OPERATING INSTRUCTIONS and INSTALLATION MANUAL. ****
Product Usage Instructions
-
Before operating the air conditioner, carefully read the OPERATING INSTRUCTIONS provided in the full version manual downloaded from the given link.
-
Service personnel should also read the OPERATING INSTRUCTIONS and INSTALLATION MANUAL before performing any operations.
-
For additional information on using the product and installation guidelines, refer to the full version OPERATING INSTRUCTIONS, INSTALLATION MANUAL, and other relevant documents available for download.
-
Safety Precautions:
-
The air conditioner uses a flammable refrigerant. In case of refrigerant leakage and contact with fire or heating parts, harmful gas can be released and there is a risk of fire. Take necessary precautions.
-
Pay attention to the symbols displayed on the indoor and/or outdoor unit for their meanings and follow the instructions accordingly.
-
Incorrect handling can result in serious hazards such as death or serious injury. Follow the instructions carefully.
-
Symbols used in the manual indicate actions to be avoided or instructions to be followed. Be cautious and adhere to them. – Do not insert your
finger or any object into the unit. -
Do not step onto the indoor/outdoor unit or place any objects on them.
-
Be careful of the risk of electric shock. Disconnect the power supply plug before performing any maintenance.
-
Ensure to shut off the power when not using the air conditioner.
-
Avoid touching the unit with wet hands and do not splash water on it.
-
In case of any mechanical failure, system malfunction, or unit breakdown, turn off the breaker or disconnect the power plug. Contact the service agent to avoid hazards and ensure product safety. Please refer to the full version OPERATING INSTRUCTIONS and INSTALLATION MANUAL for a complete understanding of product usage and safety guidelines.
-
Manual Download
http://www.mitsubishielectric.com/ldg/ibim/
This manual is brief version. Go to the above website and choose language to download full version OPERATING INSTRUCTIONS and INSTALLATION MANUAL.
SAFETY PRECAUTIONS
Meanings of symbols displayed on indoor unit and/or outdoor unit
-
WARNING (Risk of fi re): This unit uses a flammable refrigerant.
If refrigerant leaks and comes in contact with fi re or heating part, it will create harmful gas and there is risk of fire. -
Read the OPERATING INSTRUCTIONS carefully before operation.
-
Service personnel are required to carefully read the OPERATING INSTRUCTIONS and INSTALLATION MANUAL before operation.
-
Further information is available in the OPERATING INSTRUCTIONS, INSTALLATION MANUAL, and the like.
-
Since rotating parts and parts which could cause an electric shock are used in this product, be sure to read these “Safety Precautions” before use.
-
Since the cautionary items shown here are important for safety, be sure to observe them.
-
After reading this manual, keep it together with the installation manual in a handy place for easy reference.
Marks and their meanings
- WARNING: Incorrect handling could cause serious hazard, such as death, serious injury, etc. with a high probability.
- CAUTION: Incorrect handling could cause serious hazard depending on the conditions.
Meanings of symbols used in this manual
WARNING
-
Do not connect the power cord to an intermediate point, use an extension cord, or connect multiple devices to a single AC outlet.
This may cause overheating, fire, or electric shock. -
Make sure the power plug is free of dirt and insert it securely into the outlet.
A dirty plug may cause fire or electric shock. -
Do not bundle, pull, damage, or modify the power cord, and do not apply heat or place heavy objects on it.
This may cause fire or electric shock. -
Do not turn the breaker OFF/ON or disconnect/connect the power plug during operation.
- This may create sparks, which can cause fire.
- After the indoor unit is switched OFF with the remote controller, make sure to turn the breaker OFF or disconnect the power plug.
-
Do not expose your body directly to cool air for a prolonged length of time.
This could be detrimental to your health. -
The unit should not be installed, relocated, disassembled, altered, or repaired by the user.
- An improperly handled air conditioner may cause fire, electric shock, injury, or water leakage, etc. Consult your dealer.
- If the power supply cord is damaged, it must be replaced by the manufacturer or its service agent in order to avoid a hazard.
-
When installing, relocating, or servicing the unit, make sure that no substance other than the specified refrigerant (R32) enters the refrigerant circuit.
- Any presence of foreign substance such as air can cause abnormal pressure rise and may result in explosion or injury.
- The use of any refrigerant other than that specified for the system will cause mechanical failure, system malfunction, or unit breakdown. In the worst case, this could lead to a serious impediment to securing product safety.
-
This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
Children should be supervised to ensure that they do not play with the appliance. -
Do not insert your finger, a stick, or other objects into the air inlet or outlet.
This may cause injury, since the fan inside rotates at high speeds during operation. -
In case of an abnormal condition (such as a burning smell), stop the air conditioner and disconnect the power plug or turn the breaker OFF.
A continued operation in the abnormal state may cause a malfunction, fire, or electric shock. In this case, consult your dealer. -
When the air conditioner does not cool or heat, there is a possibility of refrigerant leakage. If any refrigerant leakage is found, stop operations and ventilate the room well and consult your dealer immediately. If a repair involves recharging the unit with refrigerant, ask the service technician for details.
- The refrigerant used in the air conditioner is not harmful. Normally, it does not leak. However, if refrigerant leaks and comes in contact with fire or heating part of such a fan heater, kerosene heater, or cooking stove, it will create harmful gas and there is risk of fire.
- The user should never attempt to wash the inside of the indoor unit. Should the inside of the unit require cleaning, contact your dealer.
- Unsuitable detergent may cause damage to plastic material inside the unit, which may result in water leakage. Should detergent come in contact with electrical parts or the motor, it will result in a malfunction, smoke, or fire.
- The appliance shall be stored in a room without continuously operating ignition sources (for example: open flames, an operating gas appliance or an operating electric heater).
- Be aware that refrigerants may not contain an odour.
- Do not use means to accelerate the defrosting process or to clean the appliance, other than those recommended by the manufacturer.
- Do not pierce or burn.
- The indoor unit must be installed in rooms which exceed the floor space specified. Please consult your dealer.
-
This appliance is intended to be used by expert or trained users in shops, in light industry and on farms, or for commercial use by lay persons.
CAUTION
-
Do not touch the air inlet or the aluminum fins of the indoor/outdoor unit.
This may cause injury. -
Do not use insecticides or flammable sprays on the unit.
This may cause a fire or deformation of the unit. -
Do not expose pets or houseplants to direct airfl ow.
This may cause injury to the pets or plants.
To use this unit correctly and safely, be sure to read these operating instructions before use.
SAFETY PRECAUTIONS
-
Do not place other electric appliances or furniture under the indoor/ outdoor unit.
Water may drip down from the unit, which may cause damage or malfunction. -
Do not leave the unit on a damaged installation stand.
The unit may fall and cause injury. -
Do not step on an unstable bench to operate or clean the unit.
This may cause injury if you fall down. -
Do not pull the power cord.
This may cause a portion of the core wire to break, which may cause overheating or fire. -
Do not charge or disassemble the batteries, and do not throw them into a fire.
This may cause the batteries to leak, or cause a fire or explosion. -
Do not operate the unit for more than 4 hours at high humidity (80% RH or more) and/or with windows or outside door left open.
- This may cause the water condensation in the air conditioner, which may drip down, wetting or damaging the furniture.
- The water condensation in the air conditioner may contribute to growth of fungi, such as mold.
-
Do not use the unit for special purposes, such as storing food, raising animals, growing plants, or preserving precision devices or art objects. This may cause deterioration of quality, or harm to animals and plants.
-
Do not expose combustion appliances to direct airfl ow.
This may cause incomplete combustion. -
Never put batteries in your mouth for any reason to avoid accidental ingestion.
Battery ingestion may cause choking and/or poisoning. -
Before cleaning the unit, switch it OFF and disconnect the power plug or turn the breaker OFF.
This may cause injury, since the fan inside rotates at high speeds during operation. -
When the unit will be unused for a long time, disconnect the power plug or turn the breaker OFF.
The unit may accumulate dirt, which may cause overheating or fire. -
Replace all batteries of the remote controller with new ones of the same type.
- Using an old battery together with a new one may cause overheating, leakage, or explosion.
- If the battery fluid comes in contact with your skin or clothes, wash them thoroughly with clean water.
- If the battery fluid comes in contact with your eyes, wash them thoroughly with clean water and immediately seek medical attention.
-
Ensure that the area is well-ventilated when the unit is operated together with a combustion appliance.
Inadequate ventilation may cause oxygen starvation. -
Turn the breaker OFF when you hear thunder and there is a possibility of a lightning strike.
- The unit may be damaged if lightning strikes.
-
After the air conditioner is used for several seasons, perform inspection and maintenance in addition to normal cleaning.
- Dirt or dust in the unit may create an unpleasant odor, contribute to growth of fungi, such as mold, or clog the drain passage, and cause water to leak from the indoor unit. Consult your dealer for inspection and maintenance, which require specialized knowledge and skills.
-
Do not operate switches with wet hands.
This may cause electric shock. -
Do not clean the air conditioner with water or place an object that contains water, such as a flower vase, on it.
This may cause fire or electric shock. -
Do not step on or place any object on the outdoor unit.
This may cause injury if you or the object falls down.
IMPORTANT
- Dirty filters cause condensation in the air conditioner which will contribute to the growth of fungi such as mold. It is therefore recommended to clean air filters every 2 weeks.
- Before starting the operation, ensure that the horizontal vanes are in the closed position. If operation starts when the horizontal vanes are in the open position, they may not return to the correct position.
For installation
WARNING
-
Consult your dealer for installing the air conditioner.
It should not be installed by the user since installation requires specialized knowledge and skills. An improperly installed air conditioner may cause water leakage, fire, or electric shock. -
Provide a dedicated power supply for the air conditioner.
A non-dedicated power supply may cause overheating or fire. -
Do not install the unit where flammable gas could leak.
If gas leaks and accumulates around the outdoor unit, it may cause an explosion. -
Earth the unit correctly.
Do not connect the earth wire to a gas pipe, water pipe, lightning rod, or a telephone earth wire. Improper earthing may cause electric shock.
CAUTION
-
Install an earth leakage breaker depending on the installation location of the air conditioner (such as highly humid areas).
If an earth leakage breaker is not installed, it may cause electric shock. -
Ensure that the drain water is properly drained.
If the drain passage is improper, water may drip down from the indoor/outdoor unit, wetting and damaging the furniture.
In case of an abnormal condition
Immediately stop operating the air conditioner and consult your dealer.
For Wi-Fi interface
WARNING
(Improper handling may have serious consequences, including serious injury or
death.)
-
This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved.
Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision. Do not use the Wi-Fi interface nearby the medical electrical equipment or people who have a medical device such as a cardiac pacemaker or an implantable cardioverter-defi brillator. -
It can cause an accident due to malfunctions of the medical equipment or device.
-
Do not install the Wi-Fi interface nearby the automatic control devices such as automatic doors or fire alarms.
-
It can cause accidents due to malfunctions.
-
Do not touch the Wi-Fi interface with wet hands.
-
It can cause damage to the device, electric shock, or fire.
-
Do not splash water on the Wi-Fi interface or use it in a bathroom.
-
It can cause damage to the device, electric shock, or fire.
-
When the Wi-Fi interface is dropped, or the holder or cable is damaged, disconnect the power supply plug or turn the breaker OFF.
-
It may cause fire or electric shock. In this case, consult your dealer.
CAUTION
(Improper handling may have consequences, including injury or damage to
building.)
Do not step on unstable stepstool to set up or clean the Wi-Fi interface.
- It may cause injury if you fall down.
- Do not use the Wi-Fi interface nearby other wireless devices, microwaves, cordless phones, or facsimiles.
- It can cause malfunctions.
DISPOSAL
To dispose of this product, consult your dealer.
Note:
This symbol mark is for EU countries only.
This symbol mark is according to the directive 2012/19/EU Article 14
Information for users and Annex IX, and/or to the directive 2006/66/EC Article
20 Information for end-users and Annex II.
Your MITSUBISHI ELECTRIC product is designed and manufactured with high
quality materials and components which can be recycled and/or reused.
This symbol means that electrical and electronic equipment, batteries and
accumulators, at their end-of-life, should be disposed of separately from your
household waste.
If a chemical symbol is printed beneath the symbol (Fig. 1), this chemical
symbol means that the battery or accumulator contains a heavy metal at a
certain concentration. This will be indicated as follows:
Hg: mercury (0.0005%), Cd: cadmium (0.002%), Pb: lead (0.004%)
In the European Union there are separate collection systems for used
electrical and electronic products, batteries and accumulators.
Please, dispose of this equipment, batteries and accumulators correctly at
your local community waste collection/recycling centre.
Please, help us to conserve the environment we live in!
NAME OF EACH PART
PREPARATION BEFORE OPERATION
Before operation: Insert the power supply plug into the power outlet and/or turn the breaker on.
Installing the remote controller batteries
Setting current time
PREPARATION BEFORE OPERATION
Remote controller
TIME, TIMER set button
Change the time forward/backward
CLEANING
Instructions:
- Switch off the power supply or turn off the breaker before cleaning.
- Be careful not to touch the metal parts with your hands.
- Do not use benzine, thinner, polishing powder, or insecticide.
- When dirt stands out, wash it with kitchen neutral detergent diluted with luke-warm water to the specified concentration, then wipe off the detergent with a damp towel.
- Do not use a scrubbing brush, a hard sponge, or the like.
- Do not soak or rinse the horizontal vane.
- Do not use water hotter than 50°C.
- Do not expose parts to direct sunlight, heat, or fi re to dry.
- Do not apply excessive force on the fan as it may cause cracks or breakage.
This information is based on REGULATION (EU) No 528/2012
MODEL NAME| Treated Article
(Parts name)
| Active Substances
(CAS No.)
| Property| Instruction for Use
(Safe handling information)
---|---|---|---|---
MSZ-AP60/71VG
|
FILTER
| Dimethyloctadecyl[3-(trimethoxysilyl) propyl]ammonium chloride
(27668-52-6)
Silver sodium hydrogen zirconium
phosphate
(265647-11-8)
2-octyl-2H-isothiazol-3-one (OIT) (26530-20-1)
|
Antivirus Antibacterial Antimold
|
• Use this product in line with the instruction manual indications and for the intended purpose only.
• Do not put into mouth. Keep away from children.
MAC-2460FT-E
|
FILTER
| Dimethyloctadecyl[3-(trimethoxysilyl) propyl]ammonium chloride
(27668-52-6)
| Antivirus Antibacterial Antimold| • Use this product in line with the instruction manual indications and for the intended purpose only.
• Do not put into mouth. Keep away from children.
Wi-Fi INTERFACE SETTING UP (VGK type only)
This Wi-Fi interface, communicates the status information and controls the
commands from the MELCloud by connecting to the indoor unit.
Note:
- Set up a connection between the Wi-Fi interface and the Router. Refer to the SETUP MANUAL and SETUP QUICK REFERENCE GUIDE provided with the unit.
- For SETUP MANUAL, please go to the website below. http://www.melcloud.com/Support
- For MELCloud User Manual, please go to the website below. http://www.melcloud.com/Support
SPECIFICATIONS
Model | Indoor | MSZ-AP60VG(K) | MSZ-AP71VG(K) |
---|---|---|---|
Outdoor | MUZ-AP60VG | MUZ-AP71VG | |
Function | Cooling | Heating | Cooling |
Power supply | ~ /N, 230 V, 50 Hz | ||
Capacity | kW | 6.1 | 6.8 |
Input | kW | 1.59 | 1.67 |
Weight | Indoor | kg | 16 |
Outdoor | kg | 40 | 55 |
Refrigerant filling capacity (R32) | kg | 1.05 | 1.50 |
IP code | Indoor | IP 20 | |
Outdoor | IP 24 |
Permissible excessive
operating pressure
| LP ps| MPa| 2.77
HP ps| MPa| 4.17
Noise level (SPL)
| Indoor (Super High/
High/Med./Low/Silent)
| dB(A)| 48/45/41/37/29| 48/45/41/37/30| 49/45/41/37/30| 51/45/41/37/30
Outdoor| dB(A)| 56| 57| 56| 55
Guaranteed operating range
Indoor | Outdoor |
---|
Cooling
| Upper limit| 32°C DB
23°C WB
| 46°C DB
—
Lower limit| 21°C DB
15°C WB
| -10°C DB
—
Heating
| Upper limit| 27°C DB
—
| 24°C DB
18°C WB
Lower limit| 20°C DB
—
| -15°C DB
-16°C WB
- DB: Dry Bulb
- WB: Wet Bulb
Note: Rating condition
- Cooling — Indoor: 27°C DB, 19°C WB
- Outdoor: 35°C DB
- Heating — Indoor: 20°C DB
- Outdoor: 7°C DB, 6°C WB
Wi-Fi interface
Model | MAC-567IFB2-E | MAC-577IF2-E |
---|---|---|
Input Voltage | DC12.7 V (from indoor unit) | |
Power consumption | MAX. 2 W | |
Size H×W×D (mm) | 79×44×18.5 | 73.5×41.5×18.5 |
Weight (g) (including cable) | 60 | 46 |
Transmitter power level (MAX.) | 17.5 dBm @IEEE 802.11b | 20 dBm @IEEE 802.11b |
RF channel | 1ch ~ 13ch (2412~2472 MHz) | |
Radio protocol | IEEE 802.11b/g/n (20) | |
Encryption | AES | |
Authentication | WPA2-PSK | |
Software Version | XX.00 |
For Declaration of Conformity, please go to the website below. http://www.mitsubishielectric.com/ldg/ibim/
WHEN YOU THINK THAT TROUBLE HAS OCCURRED
In the following cases, stop using the air conditioner and consult your
dealer.
- When water leaks or drips from the indoor unit.
- When the operation indicator lamp blinks.
- When the breaker trips frequently.
- The remote control signal is not received in a room where an electronic ON/OFF type fluorescent lamp (inverter-type fluorescent lamp, etc.) is used.
- Operation of the air conditioner interferes with radio or TV reception. An amplifi er may be required for the affected device.
- When an abnormal sound is heard.
- When any refrigerant leakage is found.
References
- aparatul.ro
- Dit domein is gereserveerd - Denit hosting solutions
- Durchlesen.de steht zum Verkauf! Domains für Domain-Pofis und Investoren sofort kaufen
- The domain name tension.fr is for sale | Dan.com
- uso.it
- MELCloud
- Support
- MITSUBISHI ELECTRIC
- Support
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>