Safety Considerations
- Never touch the nozzle of SPARKULAR TRIPLE, danger of getting burnt.
- Never touch the sparks which shooting out from the nozzle.
- Cover of nozzle of SPARKULAR TRIPLE is prohibited.
- Keep audience, animals or flammable objects at a minimum distance of 3m (for front and rear side) and 5m (for left and right side) from SPARKULAR TRIPLE. Make sure sparks shoot out from SPARKU- LAR TRIPLE can NOT touch any objects in the air.
- Ensure that children, animals and unauthorized persons don’t have access to the SPARKULAR TRIPLE!
- Unauthorized repair are prohibited, it may cause serious incident.
- Keep SPARKULAR TRIPLE dry and do NOT use in rain or snow.
- Make sure lid of feeding hopper are well covered when use SPARKULAR TRIPLE. Accidentally burning of Composite Ti can only use sands to extinguish. Composite Ti should keep away from moisture and stored in a dry sealed environment.
- Clear material is necessary both before and after the show. Please check nozzle of SPARKULAR TRIPLE after each show, if there are consumable agglomerated in the nozzle, please clear it with screw- driver, otherwise it will affect the sparks effects and even damage the machine.
- Maximum cascade of SPARKULAR TRIPLE is 2 units with one standard power cable. Otherwise it may damage the machine and even cause fire.
- For better heat dissipation, block the air intake and air outlet is prohibited.
Model: BT51/BT52
| Parameters
Dimension| 400x290x270mm
Weight| 20kg
Input| 6T51:AC200-240V, 50/60Hz
BT52:AC100-120V, 50/60Hz
Work power| 1500w
Working Temperature| -10 C- 50 C
Casing| Metal
Effect height| 2.0-4.0m adjustable (HC8200 MEDIUM) 2.0-5.0m adjustable (HC8200
LARGE)
Hopper capacity| 160g * 3
HC8200 consumption| 17g/min’ 3
Feature:
- Triple heads, multi effect
- Each nozzle can be controlled separately
- Faster response, stronger bursts
- RDMX function, status can be monitored by original host controller
Operation Panel
LED display area:
READY1、READY2、READY3 shows the status of 3 heads respectively;
After turn on, the machine pre-heating automatically, pre-heating time is
around 5min. When “READY” turns from flashing into long on, indicates that the
machine is ready to work.
DMX:Flashing shows that DMX signal is connected, otherwise is without signal
Control button area:
MENU: Short press to switch interface, press for 3 seconds can switch to the
advanced setup interface.
DOWN: Parameters down
UP: Parameters up
ENTER: Confirm and save parameters
Radio frequency identification area:
Composite Ti with RFID card, swiping cards to identify parameters and types of
granules.
Please note that granules RFID card can increase the single machine specific
working time. The card is disposable, can only use once.
Interface
Main Interface:
First line: temp. and error info. of each nozzle of machine Left shows nozzle
3, middle shows nozzle 2, right show nozzle 1.
Second line:shows DMX address, and remaining working time 10min 22seconds
Error information:
Error information | Explanation |
---|---|
E0 System IC | System error. |
E2 Temp. Sensor | Temperature sensor was damaged. |
E3 P Temp. Over | Machine stops working due to the chassis temperature is too |
high
E4 Time Remain| Insufficient granules or remaining time, please swiping RFID
card.
E5 K Temp. Over| Machine stops working due to the inner core temperature is
too high
E6 Heat Fail| Heating failed.
Setting interface:
Press “MENU” to enter the Setting interface, press the “MENU” button to enter
different options until you return to the main interface.
Options | Range | Instructions |
---|---|---|
Set DMX Address | 1-512 | Set the DMX address. |
Manual Fountain | ON/OFF | Manual fountain switch, for testing purpose only. |
Fountain Height | 1-10 | Manual fountain, set shooting height, for testing |
purpose only.
Advanced menu:
Press “MENU” 3 seconds to enter the advanced setup interface, press MENU key
to enter different options, wait 3 seconds to return to the main interface.
Options | Range | Explanation |
---|---|---|
Set Temperature | 500-610 | Setup inner Core temperature. Please don’t change |
default value without engineers suggestion from SHOWVEN.
Auto Heat| ON/OFF| Auto preheat function switch after turning on machine
Density| 70-100| Adjust the sparks density. Please don’t change default
value without engineers suggestion from SHOWVEN.
Mode Selection| Factory Model
User Mode| Factory Mode is factory debugging mode, User Mode is using mode
Default Parameter Mode| | Press “ENTER” to restore all parameters to the
factory settings.
Standby Switch| On/Off| When it’s on, the machine can only generate spark when
pre-heating finish.
When using the DMX controller, the system takes 6 channels, each nozzle takes 2 channels.
First channel (nozzle 1) | Functions |
---|---|
0-15 | Fountain OFF |
16-255 | Fountain ON, Height adjustable |
Second Channel (nozzle 1) | Functions |
60-80 | Clear Material |
20-40 | Emergency Stop |
0-10 | Pre-heat OFF (Disable in Auto-heat) |
240-255 | Pre-heat ON ( Disable in Auto-heat) |
Third Channel (nozzle 2) | Functions |
--- | --- |
0-15 | Fountain OFF |
16-255 | Fountain ON, Height adjustable |
Fourth Channel (nozzle 2) | Functions |
60-80 | Clear Material |
20-40 | Emergency Stop |
0-10 | Pre-heat OFF ( Disable in Auto-heat ) |
240-255 | Pre-heat ON I Disable in Auto-heat ) |
Fifth Channel (nozzle 3) | Functions |
0-15 | Fountain OFF |
16-255 | Fountain ON, Height adjustable |
Sixth Channel (nozzle 3) | Functions |
60-80 | Clear Material |
20-40 | Emergency Stop |
0-10 | Pre-heat OFF ( Disable in Auto-heat) |
240-255 | Pre-heat ON ( Disable in Auto-heat) |
Please set DMX address following below rules when connect with SHOWVEN host controller.
SPARKULAR
TRIPLE No.| 1| 2| 3| 4| 5| 6
---|---|---|---|---|---|---
DMX Address| 1| 7| 13| 19| 25| 31
Note: Wrong DMX address setting may cause uncontrolled shooting of SPARKULAR TRIPLE.
Warranty instructions
▲Sincere thanks for your choosing our products, you will receive quality
service from us.
▲The product warranty period is one year, If there is any quality problems, we
can exchangea brand new same model machine to you within seven days after
receive the product.
▲We will offer free of charge maintenance service for machines which with
hardware malfunction (except for the instrument damage caused by human
factors) in warranty period. Please don’t repair machine without factory
permission.
Below situation NOT included in warranty service:
- Damage caused by improper transportation, using, management, and maintenance, or damage caused by human factors;
- Disassemble, modified or maintenance products without Showven’s permission;
- Damage caused by external reasons (lightning strike, power supply etc);
- Damage caused by improper installation or use;
For product damage not included in warranty range, we can provide paid
service.
Invoice and warranty card are necessary when asking for service from SHOWVEN.
Warranty card
Product Name:| | Serial NO.:|
---|---|---|---
Purchase Date:|
Contact Number:|
Address:|
Customer Feedback
Information:|
Actual malfunction:|
Maintenance details:|
Maintenance person:| | Maintenance Date:|
https://www.facebook.com/Showven-228026294663699/?modal=admin_todo_tour
Showven Technologies Co., Ltd
Add:Building B1, Changsha E-Center, Liuyang Economic Development
Zone, 410300, Hunan, China.
Tel :+86-731-83833068
Web :www.showven.com
E-mail :info@showven.com
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>