APATOR MH IP68 DN50, DN65 Hydrant Water Meters Owner’s Manual

June 12, 2024
APATOR

**APATOR MH IP68 DN50, DN65 Hydrant Water Meters

**

MH IP68

MH IP68 is a screw, dry Woltman type water meter with a vertical rotor axis. The meter body, installed on a stand, is adapted for assembly using a standardised connector to an underground hydrant. Given the exposure of the water meter to various atmospheric conditions in the open, the counting mechanism has been placed in a casing made of copper sheet, which is hermetically sealed at the top by rolling in mineral glass seated on a rubber gasket.

The device is compatible with clip-on communication modules for automatic wired or wireless meter reading. The water meter is designed and manufactured to the MID (Measuring Instruments Directive) and in compliance with EN14154, OIML R49 and ISO4064.

Application

The hydrant water meter is designed for local distribution and measurement of cold water consumption with a temperature of up to 50°C and a maximum allowable working pressure of 16 bar. The water meter can be used by water supply companies, construction and agricultural companies, as well as by individual users. The structure of the water meter stand allows for quick connection to an underground water network hydrant with a diameter of 80mm. The stand can be made in two material variants: aluminium for water intake for domestic purposes and acid-resistant steel for water intake for food purposes. The water meter outlet is equipped with a quick-disconnect nozzle of size 75T. The water meter performs excellently in challenging environmental conditions, and the rotating counter enables easy reading of the water meter readings in the appropriate working positions. The standard water meter version is designed for use with universal induction communication modules which feature

UTIP (Universal TI Plug).

Advantages

Convenient use:

  • The compact construction of the water meter along with the associated stand facilitates transport
  • The structure of the water meter stand allows for quick connection to an underground water network hydrant with a diameter of 80mm
  • The MH-08 water meter is adapted to work with universal inductive clip-on modules from #UTIP
  • Alarm output capability: the meter with a universal induction communication module is capable of remote indication of any removal of or damage to the module, disruption of operation, reverse flows, leakages, and more
  • Ease of reading due to the counter’s ability to rotate freely within 358°
  • Fog-resistant hermetic counter: counter mechanism enclosed in a glass-copper casing with an IP68 protection rating

Reliability

  • Tested and robust design
  • Durably protected by design from strong magnetic field interference per EN-14154
  • Long operating life thanks to advanced wear-resistant materials of bearings and pivots
  • The counter mechanism is protected against mechanical damage
  • Permanently mounted strainer at the inlet to the water meter’s measuring chamber

Key features

  • The water meter is adapted to work in harsh environmental conditions, independently or with an installed communication module for remote readings in the AMR system
  • Magnetic coupling
  • Counter protected by a lid
  • Protection against:
    • strong magnetic field interference per EN 14154
    • mechanical tampering (with a robust, tamper-proof counter and cover design)
  • Potable water approved materials

Design of the cover and dial of the MH-08 hydrant water meter with an IP68 protection rating

Regulatory and standard compliance

  • Directive 2014/32/EC of the European Parliament and of the Council of 26 February 2014 on the harmonisation of the laws of the Member States relating to the making available on the market of measuring instruments
  • Polish Act of 13/04/2016 on market surveillance and compliance assessment systems
  • OIML R 49-1:2013 – Water meters intended for the metering of cold potable water and hot water. Part 1: Metrological and technical requirements
  • OIML R 49-2:2013 – Water meters intended for the metering of cold potable water and hot water. Part 2: Test methods
  • OIML R 49-3:2013 – Water meters intended for the metering of cold potable water and hot water. Part 3: Test report format
  • EN 14154-1:2005+A2:2011 – Water meters. Part 1: General requirements
  • EN 14154-2:2005+A2:2011 – Water meters. Part 2: Installation and conditions of use
  • EN 14154-3:2005+A2:2011 – Water meters. Part 3: Test methods and equipment
  • EN ISO 4064-1:2017 – Water meters for cold potable water and hot water. Part 1: Metrological and technical requirements
  • EN ISO 4064-2:2017 – Water meters for cold potable water and hot water. Part 2: Test methods
  • EN ISO 4064-5:2017 – Water meters for cold potable water and hot water. Part 5: Installation requirements
  • EU type examination certificate no. – SK 16-MI001-SMU044
  • Classification of environmental climate and mechanical conditions: Class B (ref. EN-ISO 4064-1:2014 (E)
  • Classification of mechanical environmental conditions: Class M1, as per Directive 2014/32/EC of the European Parliament and of the Council of 26 February 2014
  • Classification of environmental electromagnetic conditions: Class E1, E2 (ref. EN– ISO 4046: 2014 and with Directive 2014/32/EU of the European Parliament and of the Council of February 26, 2014.

**PZH National Institute of Hygiene and WRAS certificates (all materials used in MH water meters have Hygiene Certificates for use with potable water).

**

Table 1. Technical data

Parameter MH-08
MH50-08 MH65-08
Nominal diameter DN
Permanent flow rate Q3
Overload flow rate Q4
Transitional flow rate Q2
Minimum flow rate Q1
Volumetric flow rate at a pressure loss of 0.1 bar
Coefficient Q2/ Q1
Measurement range, R Q3/ Q1
Scale interval
Temperature class (rated operating temperature)
Flow profile sensitivity class
Indicating range
Resolution of reading
Maximum pressure Pmax
Maximum pressure loss at Q3 Δp
Maximum permissible error range: Q2 ≤ Q ≤ Q4 __

ε

| %| ±2 for 0.1≤T ≤30°C cold water

±3 for T >30°C water

Maximum permissible error range: Q1 ≤ Q < Q2| __

ε

| %| ±5% for 0.1≤T≤30°C
Ingress protection rating| –| –| IP68
Height| H| mm| 906| 912.5
h| mm| 807| 801.3
Length| L| mm| 130| 130
S| mm| 330| 330
Diameter| d| mm| 65| 65
Weight| –| kg| 10| 10.3

Example of the MH IP68 water meter with compatible data communication

modules:

IN-GSM clip-on module #UTIP (Universal TI Plug)

DN 50 65
H1 mm 1006 1013.26
H2 mm 1010 1017.26

IN-WMBUS clip-on module #UTIP (Universal TI Plug)

DN 50 65
H1 mm 966.7 1003.96
H2 mm 987.7 1024.96

Pressure loss chart

Typical error chart

Remote indication relay & flow rate measurement

Customer Support

The data presented in the datasheet was correct on the date of publication.
The manufacturer has the right to modify and improve the products without notice.
This publication is indicative only and should not be construed as a commercial offer under the Polish Civil Code.

Apator Powogaz S.A.
Jaryszki 1c, 62-023 Żerniki
Office: sekretariat.powogaz@apator.com, tel. +48 61 84 18 101
Sales / Customer Service: tel.: +48 61 84 18 149
Customer Service Centre Support: handel.powogaz@apator.com
Exports: export.powogaz@apator.com
Technical Support: support.powogaz@apator.com, tel. +48 61 8418 131, 134, 294
Warranty Claims: reklamacje.powogaz@apator.com

www.apator.com

References