APATOR MWN-JS-S Compound Water Meters
Product Information
The water meters mentioned in the user manual are categorized into different types:
- Vane-wheel water meters
- Vane-wheel water meters with impulse transmitters
- Volumetric water meters
- Propeller water meters with horizontal water axes
- Compound water meters with spring valves
- Well water meters
- Meters for irrigation water
These water meters have different specifications and features. Some of them have additional certifications like CE, MID, HC, WRAS, and different degrees of IP rating (IP65, IP68), which may be available on request.
Product Usage Instructions
- Installation should be performed by individuals withauthorizations related to the use of water supply and sewage networks.
- Prior to installation or dismantling, close all valves and place a vessel underneath the device.
- Install the water meter in line with the flow of water.
- It is recommended to install a sediment filter before the water meter.
- Ensure there are straight sections before and after the water meter that comply with the specified dimensions.
- Avoid air locks by not installing the water meter at the highest point of the installation.
- Do not install the water meter face down.
- Avoid strain resulting from installing the water meter on non-coaxial installations.
- Protect the water meter from flooding, freezing, high temperatures, UV radiation, vibrations, acids, gas, electrical installations, impact, and the hydrodynamic water hammer effect.
- If the water meter is damaged, send it to the service center for repair.
For more detailed information on the operation of the device, please visit www.apator.com.
WATERMETER TYPES
TRANSPORTATION AND STOCK CONDITIONS
Protect against shock and vibration Storage at temperatures above 0°C
ESSENTIAL INFORMATION
| |
---|---|---
DN15| 17| 29| 25 Nm
DN15***| 17| 29| 15 Nm
DN20| 20| 36| 30 Nm
DN25| 36| 47| 35 Nm
DN32| 44| 54| 40 Nm
DN40| 46| 67| 45 Nm
Pipelines may feature other fastener sizes
COMPONENTS REQUIRED TO INSTALL WATER METERS
Couplings available from Apator Powogaz
[G] | [g] | [d] | [L] | Indeks | |
---|---|---|---|---|---|
Set of couplings with gaskets DN 15 mm | ¾” | ½” | 17 mm | 37,5 | 0616-100-018 |
Set of couplings with gaskets DN 20 mm | 1” | ¾” | 23 mm | 45,5 | 0616-100-019 |
Set of couplings with gaskets DN 25 mm | 1¼” | 1” | 29 mm | 46,5 | 0616-100-021 |
Set of couplings with gaskets DN 32 mm | 1½” | 1¼” | 36 mm | 56,0 | 0616-100-026 |
Set of couplings with gaskets DN 40 mm | 2” | 1½” | 43 mm | 66,0 | 0616-100-020 |
Set of couplings with gaskets DN 50 mm | 2½” | 2” | 54 mm | 76,0 | 0616-100-035 |
Gaskets for flange connections compliant with PN-EN 1514-1:2001
| | | d1| d2
---|---|---|---|---
DN40| 49| 92
DN50| 61| 107
DN65| 77| 127
DN80| 89| 142
DN100| 115| 162
DN125| 141| 192
DN150| 169| 218
DN200| 220| 273
DN250| 273| 329
DN300| 324| 384
INSTALLATION AND OPERATION GUIDELINES
Do not place the used device together with municipal waste. Take it to a waste
segregation point – comply with the rules of recycling.
IMPORTANT: Detailed information on the operation of the device can be
found at www.apator.com
INSTALLATION POSSIBILITIES AND REQUIREMENTS
- acceptable deviation from the vertical mounting ± 3°
CLASSIFICATION OF ENVIRONMENTAL CONDITIONS
- Mechanical class acc. to RMG from 18 December 2006 (MID) – M1
- Electromagnetic class acc. to RMG from 18 December 2006 (MID) – E1
- Climatic and mechanical class acc. to PN-EN 14154-3:2005 + A1 – B
CONFIGURATION
CONFIGURATION OF A SPECIFIC WATER METER WITH A TRANSMITTER OR A SLEEVE – DETAILS FROM THE MANUFACTURER
Apator Powogaz S.A. reserves the right to modify and improve the manufactured devices without notice.
Apator Powogaz S.A.
Jaryszki 1c, 62-023 Żerniki, Poland
www.apator.com
Secretariat:
sekretariat.powogaz@apator.com,
tel. +48 61 84 18 101
Sales Department/Customer Service: tel: +48 61 84 18 149
Customer Service Center:
handel.powogaz@apator.com
Export: export.powogaz@apator.com
Technical support:
support.powogaz@apator.com,
tel. +48 61 8418 131, 134, 294
Complaints:
reklamacje.powogaz@apator.com
References