Product Information

The water meters mentioned in the user manual are categorized into different types:

  • Vane-wheel water meters
  • Vane-wheel water meters with impulse transmitters
  • Volumetric water meters
  • Propeller water meters with horizontal water axes
  • Compound water meters with spring valves
  • Well water meters
  • Meters for irrigation water

These water meters have different specifications and features. Some of them have additional certifications like CE, MID, HC, WRAS, and different degrees of IP rating (IP65, IP68), which may be available on request.

Product Usage Instructions

  • Installation should be performed by individuals withauthorizations related to the use of water supply and sewage networks.
  • Prior to installation or dismantling, close all valves and place a vessel underneath the device.
  • Install the water meter in line with the flow of water.
  • It is recommended to install a sediment filter before the water meter.
  • Ensure there are straight sections before and after the water meter that comply with the specified dimensions.
  • Avoid air locks by not installing the water meter at the highest point of the installation.
  • Do not install the water meter face down.
  • Avoid strain resulting from installing the water meter on non-coaxial installations.
  • Protect the water meter from flooding, freezing, high temperatures, UV radiation, vibrations, acids, gas, electrical installations, impact, and the hydrodynamic water hammer effect.
  • If the water meter is damaged, send it to the service center for repair.

For more detailed information on the operation of the device, please visit www.apator.com.

WATERMETER TYPES

APATOR-MWN-JS-S-Compound-Water-Meters- \(1\)

TRANSPORTATION AND STOCK CONDITIONS
Protect against shock and vibration Storage at temperatures above 0°C

ESSENTIAL INFORMATION

APATOR-MWN-JS-S-Compound-Water-Meters- \(2\)

 | |
---|---|---
DN15| 17| 29| 25 Nm
DN15***| 17| 29| 15 Nm
DN20| 20| 36| 30 Nm
DN25| 36| 47| 35 Nm
DN32| 44| 54| 40 Nm
DN40| 46| 67| 45 Nm

Pipelines may feature other fastener sizes

COMPONENTS REQUIRED TO INSTALL WATER METERS

Couplings available from Apator Powogaz

  [G] [g] [d] [L] Indeks
Set of couplings with gaskets DN 15 mm ¾” ½” 17 mm 37,5 0616-100-018
Set of couplings with gaskets DN 20 mm 1” ¾” 23 mm 45,5 0616-100-019
Set of couplings with gaskets DN 25 mm 1¼” 1” 29 mm 46,5 0616-100-021
Set of couplings with gaskets DN 32 mm 1½” 1¼” 36 mm 56,0 0616-100-026
Set of couplings with gaskets DN 40 mm 2” 1½” 43 mm 66,0 0616-100-020
Set of couplings with gaskets DN 50 mm 2½” 2” 54 mm 76,0 0616-100-035

Gaskets for flange connections compliant with PN-EN 1514-1:2001

|  |  | d1| d2
---|---|---|---|---

DN40| 49| 92
DN50| 61| 107
DN65| 77| 127
DN80| 89| 142
DN100| 115| 162
DN125| 141| 192
DN150| 169| 218
DN200| 220| 273
DN250| 273| 329
DN300| 324| 384

INSTALLATION AND OPERATION GUIDELINES

APATOR-MWN-JS-S-Compound-Water-Meters- \(7\) APATOR-
MWN-JS-S-Compound-Water-Meters- \(8\)

Do not place the used device together with municipal waste. Take it to a waste segregation point – comply with the rules of recycling.
IMPORTANT: Detailed information on the operation of the device can be found at www.apator.com

INSTALLATION POSSIBILITIES AND REQUIREMENTS

APATOR-MWN-JS-S-Compound-Water-Meters- \(9\)

  • acceptable deviation from the vertical mounting ± 3°

CLASSIFICATION OF ENVIRONMENTAL CONDITIONS

  • Mechanical class acc. to RMG from 18 December 2006 (MID) – M1
  • Electromagnetic class acc. to RMG from 18 December 2006 (MID) – E1
  • Climatic and mechanical class acc. to PN-EN 14154-3:2005 + A1 – B

CONFIGURATION

CONFIGURATION OF A SPECIFIC WATER METER WITH A TRANSMITTER OR A SLEEVE – DETAILS FROM THE MANUFACTURER

APATOR-MWN-JS-S-Compound-Water-Meters- \(10\) APATOR-MWN-JS-S-Compound-Water-Meters- \(11\)

Apator Powogaz S.A. reserves the right to modify and improve the manufactured devices without notice.

Apator Powogaz S.A.
Jaryszki 1c, 62-023 Żerniki, Poland
www.apator.com

Secretariat: sekretariat.powogaz@apator.com, tel. +48 61 84 18 101
Sales Department/Customer Service: tel: +48 61 84 18 149
Customer Service Center: handel.powogaz@apator.com
Export: export.powogaz@apator.com
Technical support: support.powogaz@apator.com,
tel. +48 61 8418 131, 134, 294
Complaints: reklamacje.powogaz@apator.com

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals