APATOR Elf 2 DN 15-20 Compact Heat Meter Instruction Manual

June 12, 2024
APATOR

APATOR-logo

APATOR Elf 2 DN 15-20 Compact Heat Meter

APATOR-Elf-2-DN-15-20-Compact-Hea-Meter-product

Product Information

  • Product Name: Heat Meter
  • Product Type: Compact heat meter
  • Model: Elf 2 DN 15-20
  • Certifications: CE, MID, IP65

Transportation and Stock Conditions
Protect against shock and vibration

Essential Information

  • Operating range: Not specified
  • Ambient temperature range: Not specified
  • Operating pressure: max 16 bar
  • DN15: 17-29
  • DN20: 20-36
  • Pipelines may feature other fastener sizes
  • Parametrs Elf 2 :
    • Q3 [m3/h]: 0.6, 1, 1.5, 1.5, 2.5
    • DN [mm]: 15, 15, 15, 20, 20
    • Length [mm]: 110, 110, 110, 130, 130

Components Required for Heat Meter Installation

  • Couplings available from Apator Powogaz:
    • G [d] [L] Indeks Set of couplings with gaskets DN 15 mm: 1
    • G [d] [L] Indeks Set of couplings with gaskets DN 20 mm: 1

Classification of Environmental Conditions

  • Technical class acc. to RMG from 18 December 2006 (MID): M1
  • Electromagnetic class acc. to RMG from 18 December 2006 (MID): E1
  • Climatic and mechanical class acc. to PN-EN 14154-3:2005 + A1: B

Product Usage Instructions

  1. Installation shall be performed by persons with authorizations related to the use of water supply and sewage networks.
  2. Close all valves prior to installation/dismantling. When installing/dismantling the valves, place a vessel underneath the device.
  3. Install the heat meter in the direction of water flow.
  4. Straight sections before and after the heat meter should be used according to the recommendations contained in the manual at www.apator.com.
  5. Protect from air locks, do not install at the highest point of the installation.
  6. Do not install the heat meter with the counter downwards.
  7. Protect against stress resulting from mounting on misaligned installation.
  8. Protect from flooding.
  9. Protect from freezing.
  10. Protect from high temperatures and UV radiation.
  11. Do not expose to vibrations.
  12. Do not use near acids, gas, and electrical installations.
  13. Protect from impact.
  14. Protect from the hydrodynamic water hammer effect.
  15. Protect from contaminants at the installation site.

Service
Send damaged water meters to the service center.

IMPORTANT: Detailed information on the
operation of the device can be found at www.apator.com

DETAILED MOUNTING OPTIONS AND REQUIREMENTS ARE SPECIFIED IN THE MANUAL AVAILABLE AT: www.apator.com Mounting Positions

  • Elf 2: U, D, U0, D0, M, nx, U, D, nx, U5, D3

Configuration of a Specific Heat Meter with Transmitter and Water Meter – Details from the Manufacturer

  • Water meter: NK white

  • Transmitter: brown US < 30 VDC IS < 100 mA YTLY cable
    2×0,14 mm2, L = 2 m

  • Optical Pulse module:

    • white – Pulse out #1
    • green – GDN
    • brown – Pulse out #2
    • yellow UO < 30 VDC IO = 250 mA YTLY cable 4×0,14 mm2, L = 1,45 m
  • Inductive Pulse Module:

    • white – Pulse out #1
    • brown – Pulse out #2
    • yellow – Alarm output
    • green – GDN
    • blue – Wire break sensing
  • M-Bus + 4 pulse inputs: W1, W2

  • Heat meter:

    • W3 Elf 2
    • W4 M-Bus + 2 pulse inputs + 1 pulse output RS485 Modbus enabled USB (service access) Wireless M-Bus T1 + 2 pulse inputs
  • Short-circuit current up to 100 mA Max voltage 30 V 5-wire cable, L = 3 m

Apator Powogaz S.A. reserves the right to modify and improve the manufactured devices without notice.

Apator Powogaz S.A. Jaryszki 1c, 62-023 erniki
Website: www.apator.com
Office: [email protected], tel. +48 61 84 18 101
Sales Department/Customer Service: tel: +48 61 84 18 149
Customer Service Center: [email protected]
Export: [email protected]
Technical support: [email protected], tel. +48 61 8418
131, 134, 294
Complaints: [email protected]

HEAT METER TYPE

APATOR-Elf-2-DN-15-20-Compact-Hea-Meter- \(1\)

TRANSPORTATION AND STOCK CONDITIONS

  • Protect against shock and vibration
  • Storage at temperatures above 0°C

ESSENTIAL INFORMATION

Operating range max 0,1-90°C
Ambient temperature range 5-55°C
Operating pressure max 16 bar
Parametrs Q3 [m 3 /h]

Connection
---|---|---|---|---




Elf 2

| 0,6| 15| 110| G¾
1| 15| 110| G¾
1,5| 15| 110| G¾
1,5| 20| 130| G1
2,5| 20| 130| G1
| | **
---|---|---
DN15| 17| 29| 25 Nm
DN20**| 20| 36| 30 Nm

Pipelines may feature other fastener sizes

COMPONENTS REQUIRED TO HEAT METER INSTALL

Couplings available from Apator Powogaz| [G]| [g]| [d]| [L]| Indeks
---|---|---|---|---|---
Set of couplings with gaskets DN 15 mm| ¾”| ½”| 17 mm| 37,5| 0616-100-018
Set of couplings with gaskets DN 20 mm| 1”| ¾”| 23 mm| 45,5| 0616-100-019

APATOR-Elf-2-DN-15-20-Compact-Hea-Meter- \(7\)

CLASSIFICATION OF ENVIRONMENTAL CONDITIONS

  •  Technical class acc. to RMG from 18 December 2006 (MID)
  • M1  Electromagnetic class acc. to RMG from 18 December 2006 (MID)
  • E1 Climatic and mechanical class acc. to PN-EN 14154-3:2005 + A1 – B

INSTALLATION AND OPERATION GUIDELINES

  • Installation shall be performed by persons with authorisations related to the use of water supply and sewage networks

  • Close all valves prior to installation/dismantling

  • When installing/dismantling the valves, place a vessel underneath the device

  • Install the heat meter in the direction of water flow

  • Straight sections before and after the heat meter should be used according to the recommendations contained in the manual at www.apator.com

  • Protect from air locks, do not install at the highest point of the installation

  • Do not install the heat meter with the counter downwards

  • Protect against stress resulting from mounting on misaligned installation

  • Protect from flooding

  • Protect from freezing
    APATOR-Elf-2-DN-15-20-Compact-Hea-Meter- \(13\)

  • Protect from high temperatures and UV radiation

  • Do not expose to vibrations

  • Do not use near acids, gas and electrical installations

  • Protect from impact

  • Protect from the hydrodynamic water hammer effect
    APATOR-Elf-2-DN-15-20-Compact-Hea-Meter- \(14\)

  • Protect from contaminants at the installation site

  • SERVICE Send damaged water meters to the service centre

Do not place the used device together with municipal waste. Take it to a waste segregation SERVICE point – comply with the rules of recycling.

IMPORTANT: Detailed information on the operation of the device can be found at www.apator.com

DETAILED MOUNTING OPTIONS AND REQUIREMENTS ARE SPECIFIED IN THE MANUAL AVAILABLE AT: www.apator.com

APATOR-Elf-2-DN-15-20-Compact-Hea-Meter- \(16\)

CONFIGURATION OF A SPECIFIC HEAT METER WITH TRANSMITTER AND WATER METER – DETAILS FROM THE MANUFACTURER

APATOR-Elf-2-DN-15-20-Compact-Hea-Meter- \(17\)

Apator Powogaz S.A. reserves the right to modify and improve the manufactured devices without notice.

Apator Powogaz S.A. Jaryszki 1c, 62-023 Żerniki www.apator.com

Office: [email protected], tel. +48 61 84 18 101
Sales Department/Customer Service: tel: +48 61 84 18 149
Customer Service Center: [email protected]
Export: [email protected]
Technical support: [email protected],
tel. +48 61 8418 131, 134, 294
Complaints: [email protected]

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

APATOR User Manuals

Related Manuals