Product Information
- Product Name: Heat Meter
- Product Type: Compact heat meter
- Model: Elf 2 DN 15-20
- Certifications: CE, MID, IP65
Transportation and Stock Conditions
Protect against shock and vibration
Essential Information
- Operating range: Not specified
- Ambient temperature range: Not specified
- Operating pressure: max 16 bar
- DN15: 17-29
- DN20: 20-36
- Pipelines may feature other fastener sizes
- Parametrs Elf 2 :
- Q3 [m3/h]: 0.6, 1, 1.5, 1.5, 2.5
- DN [mm]: 15, 15, 15, 20, 20
- Length [mm]: 110, 110, 110, 130, 130
Components Required for Heat Meter Installation
- Couplings available from Apator Powogaz:
- G [d] [L] Indeks Set of couplings with gaskets DN 15 mm: 1
- G [d] [L] Indeks Set of couplings with gaskets DN 20 mm: 1
Classification of Environmental Conditions
- Technical class acc. to RMG from 18 December 2006 (MID): M1
- Electromagnetic class acc. to RMG from 18 December 2006 (MID): E1
- Climatic and mechanical class acc. to PN-EN 14154-3:2005 + A1: B
Product Usage Instructions
- Installation shall be performed by persons with authorizations related to the use of water supply and sewage networks.
- Close all valves prior to installation/dismantling. When installing/dismantling the valves, place a vessel underneath the device.
- Install the heat meter in the direction of water flow.
- Straight sections before and after the heat meter should be used according to the recommendations contained in the manual at www.apator.com.
- Protect from air locks, do not install at the highest point of the installation.
- Do not install the heat meter with the counter downwards.
- Protect against stress resulting from mounting on misaligned installation.
- Protect from flooding.
- Protect from freezing.
- Protect from high temperatures and UV radiation.
- Do not expose to vibrations.
- Do not use near acids, gas, and electrical installations.
- Protect from impact.
- Protect from the hydrodynamic water hammer effect.
- Protect from contaminants at the installation site.
Service
Send damaged water meters to the service center.
IMPORTANT: Detailed information on the
operation of the device can be found at
www.apator.com
DETAILED MOUNTING OPTIONS AND REQUIREMENTS ARE SPECIFIED IN THE MANUAL AVAILABLE AT: www.apator.com Mounting Positions
- Elf 2: U, D, U0, D0, M, nx, U, D, nx, U5, D3
Configuration of a Specific Heat Meter with Transmitter and Water Meter – Details from the Manufacturer
-
Water meter: NK white
-
Transmitter: brown US < 30 VDC IS < 100 mA YTLY cable
2×0,14 mm2, L = 2 m -
Optical Pulse module:
- white – Pulse out #1
- green – GDN
- brown – Pulse out #2
- yellow UO < 30 VDC IO = 250 mA YTLY cable 4×0,14 mm2, L = 1,45 m
-
Inductive Pulse Module:
- white – Pulse out #1
- brown – Pulse out #2
- yellow – Alarm output
- green – GDN
- blue – Wire break sensing
-
M-Bus + 4 pulse inputs: W1, W2
-
Heat meter:
- W3 Elf 2
- W4 M-Bus + 2 pulse inputs + 1 pulse output RS485 Modbus enabled USB (service access) Wireless M-Bus T1 + 2 pulse inputs
-
Short-circuit current up to 100 mA Max voltage 30 V 5-wire cable, L = 3 m
Apator Powogaz S.A. reserves the right to modify and improve the manufactured devices without notice.
Apator Powogaz S.A. Jaryszki 1c, 62-023 erniki
Website: www.apator.com
Office:
sekretariat.powogaz@apator.com, tel.
+48 61 84 18 101
Sales Department/Customer Service: tel: +48 61 84 18 149
Customer Service Center:
handel.powogaz@apator.com
Export: export.powogaz@apator.com
Technical support:
support.powogaz@apator.com, tel. +48 61
8418
131, 134, 294
Complaints:
reklamacje.powogaz@apator.com
HEAT METER TYPE
TRANSPORTATION AND STOCK CONDITIONS
- Protect against shock and vibration
- Storage at temperatures above 0°C
ESSENTIAL INFORMATION
Operating range | max 0,1-90°C |
---|---|
Ambient temperature range | 5-55°C |
Operating pressure | max 16 bar |
Parametrs | Q3 [m 3 /h] |
Connection
---|---|---|---|---
Elf 2
| 0,6| 15| 110| G¾
1| 15| 110| G¾
1,5| 15| 110| G¾
1,5| 20| 130| G1
2,5| 20| 130| G1
| | **
---|---|---
DN15| 17| 29| 25 Nm
DN20**| 20| 36| 30 Nm
Pipelines may feature other fastener sizes
COMPONENTS REQUIRED TO HEAT METER INSTALL
Couplings available from Apator Powogaz| [G]|
[g]| [d]| [L]| Indeks
---|---|---|---|---|---
Set of couplings with gaskets DN 15 mm| ¾”| ½”| 17 mm| 37,5| 0616-100-018
Set of couplings with gaskets DN 20 mm| 1”| ¾”| 23 mm| 45,5| 0616-100-019
CLASSIFICATION OF ENVIRONMENTAL CONDITIONS
- Technical class acc. to RMG from 18 December 2006 (MID)
- M1 Electromagnetic class acc. to RMG from 18 December 2006 (MID)
- E1 Climatic and mechanical class acc. to PN-EN 14154-3:2005 + A1 – B
INSTALLATION AND OPERATION GUIDELINES
-
Installation shall be performed by persons with authorisations related to the use of water supply and sewage networks
-
Close all valves prior to installation/dismantling
-
When installing/dismantling the valves, place a vessel underneath the device
-
Install the heat meter in the direction of water flow
-
Straight sections before and after the heat meter should be used according to the recommendations contained in the manual at www.apator.com
-
Protect from air locks, do not install at the highest point of the installation
-
Do not install the heat meter with the counter downwards
-
Protect against stress resulting from mounting on misaligned installation
-
Protect from flooding
-
Protect from freezing
-
Protect from high temperatures and UV radiation
-
Do not expose to vibrations
-
Do not use near acids, gas and electrical installations
-
Protect from impact
-
Protect from the hydrodynamic water hammer effect
-
Protect from contaminants at the installation site
-
SERVICE Send damaged water meters to the service centre
Do not place the used device together with municipal waste. Take it to a waste segregation SERVICE point – comply with the rules of recycling.
IMPORTANT: Detailed information on the operation of the device can be found at www.apator.com
DETAILED MOUNTING OPTIONS AND REQUIREMENTS ARE SPECIFIED IN THE MANUAL AVAILABLE AT: www.apator.com
CONFIGURATION OF A SPECIFIC HEAT METER WITH TRANSMITTER AND WATER METER – DETAILS FROM THE MANUFACTURER
Apator Powogaz S.A. reserves the right to modify and improve the manufactured devices without notice.
Apator Powogaz S.A. Jaryszki 1c, 62-023 Żerniki www.apator.com
Office:
sekretariat.powogaz@apator.com, tel.
+48 61 84 18 101
Sales Department/Customer Service: tel: +48 61 84 18 149
Customer Service Center:
handel.powogaz@apator.com
Export: export.powogaz@apator.com
Technical support:
support.powogaz@apator.com,
tel. +48 61 8418 131, 134, 294
Complaints:
reklamacje.powogaz@apator.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>