V I V O FAN7291 Integrated Bathroom Heat Fan Light Instruction Manual

June 12, 2024
V I V O

V I V O FAN7291 Integrated Bathroom Heat Fan Light

VIVO-FAN7291-Integrated-Bathroom-Heat-Fan-Light-
product

Product Information

  • The VIVO Integrated Bathroom Heat-Fan-Light Model: FAN7291 is an all-in-one unit designed to provide heat, ventilation, and lighting in your bathroom. It is important to follow the installation instructions and hire a registered electrician to ensure compliance with electrical and building regulations.
  • The unit should not be installed in a location where water splashing into the heater is possible. Proper ventilation is necessary for efficient operation, and replacement air must be able to enter the room to maintain air flow. The appliance should not be covered with insulating material.
  • Clearance requirements should be followed to prevent overheating or fire risks. The unit must be mounted at least 2.1 meters above the floor and at least 250mm away from vertical walls. The area behind the installation location should be clear of cables, pipes, joists, or hidden utilities.
  • Installation involves cutting a hole in the ceiling using the provided template. The clamping arms should be adjusted to ensure a proper fit. The unit should be gently inserted into the cut-out hole, and the clamping arms should be rotated out and tightened to secure the unit. The LED panel power connector should be connected, and the fascia should be attached aligning the HEATER marking on the inside of the fascia with the HEATER marking on the HFL body.
  • Ducting can be attached to extract air to the soffit or outer wall using the provided flexible ducting, duct clamp, and vent outlet grille.

Product Usage Instructions

  1. Ensure that the installation location is suitable and meets clearance requirements.
  2. Read and save the installation instructions for future reference.
  3. Ensure proper ventilation by allowing replacement air to enter the room, such as through a door undercut or slightly open window.
  4. Check for obstructions in the ceiling space and ensure sufficient height clearance for the housing.
  5. Make sure the electrical wiring can be routed from the wall switches to the mounting location.
  6. Mount the unit at least 2.1 meters above the floor and at least 250mm away from vertical walls.
  7. Use the provided template to mark and cut a hole in the ceiling, ensuring sufficient space for the clamping arms to operate.
  8. Remove the rear terminal cover and connect the wires according to the provided wiring diagram. Refit the terminal cover.
  9. If ducting is required, connect it after the unit is installed in the ceiling.
  10. Gently insert the unit into the cut-out hole, making sure to move the side clamping arms inwards to avoid damaging the plasterboard.
  11. Rotate all six clamping arms out using the levers, then tighten the six screws to clamp and secure the unit.
  12. Connect the LED panel power connector.
  13. Attach the fascia to the body, aligning the HEATER marking on the inside of the fascia with the HEATER marking on the HFL body. Tighten the screws, avoiding overtightening.
  14. Attach ducting to extract air to the soffit or outer wall using the provided flexible ducting, duct clamp, and vent outlet grille.
  • Please read all instructions before commencing installation.

IMPORTANT

  • This integrated VIVO bathroom heat-fan-light unit must be installed by a registered electrician and its installation and connection to the power supply must comply with all current Australian and New Zealand electrical and building regulations including
  • AS/NZS3000, or latest edition thereof.
  • The power supply cable must be suitably rated by a registered electrician to satisfy the total load on that circuit.

FOR YOUR SAFETY

  • Use this heat-fan-light unit only as described in this manual. Any other use not recommended by the manufacturer may cause fire, electric shock, or injury to persons. If you have questions, contact the manufacturer or local agent.
  • To prevent electrical shock, please ensure that power is DISCONNECTED before installing.
  • All wiring must be carried out by a licensed electrician in accordance with all national wiring codes.
  • When cutting into the ceiling, do not damage electrical wiring and other hidden utilities.
  • The heat-fan-light unit must be properly earthed.
  • This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
  • Children should be supervised to ensure that they do not play with the unit.
  • The surface is extremely hot when in use. Allow surface to cool sufficiently before touching or replacement.
  • Exhaust fans may adversely affect the safe operation of burning gas or other fuels (including those in other rooms) due to back flow of combustion gases. These gases can potentially result in carbon monoxide poisoning. After installation of an exhaust fan \
  • such as a partition fan or a duct fan the operation of flued gas appliances should be tested by a competent person to ensure that back flow of combustion gases does not occur.
  • Any alterations or additions to building wiring must be completed by a licensed electrician or person authorised by legislation to work on the fixed wiring of any electrical installation.

INTRODUCTION AND CONSIDERATIONS

  • Read these instructions carefully before installing & using the product.
  • Always operate this product from a power source of the same voltage, frequency and rating as indicated on rating label.
  • This product is designed for installation in flat ceilings only. Don’t mount on a sloping ceiling or a vertical wall.
  • Locate and install the product in accordance with the requirements of AS/NZS 3000 and local building codes.
  • Do not install in a location where there is a possibility of water splashing into the heater.

VENTILATION REQUIREMENTS

  • For the exhaust fan to work efficiently, replacement air of a volume equivalent to what is being extracted must be able to enter the room.
  • Generally, air would be drawn under the door (20mm undercut), or through a slightly open window. If the room is airtight, the fan will operate poorly. Air flow path should ideally pass over the steam source.
  • Before commencing any cutting, check in the ceiling space that there are no obstructions such as ceiling joists and that there is sufficient height clearance for the housing. Check that the electrical wiring can be routed from the wall switches to the mounting location.
  • The appliance shall, under no circumstances, be covered with insulating, or similar, material.

CLEARANCE REQUIREMENTS

  • This unit must be mounted at least 250mm away from vertical walls.
  • A minimum clearance of 100mm is required above the top of the unit.
  • Additionally a minimum of 50mm clearance is required between the sides of unit and joists, walls or insulation.
  • The minimum clearance distance of 100 mm from the top of the luminaire to any normally flammable building element.
  • The minimum clearance distance of 100 mm from the top of the luminaire to any building insulation.
  • The minimum clearance distance of 50 mm from the side of the luminaire to any normally flammable building element.
  • The minimum clearance distance of 50 mm from the side of the luminaire to any building insulation.c

WARNING
RISK OF OVERHEATING OR FIRE IF THE CLEARANCE DISTANCES ARE COMPROMISED.VIVO-
FAN7291-Integrated-Bathroom-Heat-Fan-Light-fig-2

INSTALLATION

  1. This unit must be mounted at least 2.1 meters above the floor and at least 250mm away from vertical walls.
  2. Ensure area behind the installation location is clear of all cables, pipes, joists or hidden utilities.
  3. Use the template provided to mark and cut a hole in the ceiling (Refer specifications for hole size) ensure sufficient space for the clamping arms to operate.
    • Ensure the gap between the clamping arm and lip of the body is slightly larger than the thickness of the ceiling. Adjust accordingly.
  4. Remove rear terminal cover and connect wires as per wiring diagram below. Refit terminal cover.
    • Note: Connect ducting (if required) after the unit is installed in the ceiling.
  5. Gently insert the unit into the cut out hole ensuring to move the side clamping arms inwards so that the body can pass through the hole without damaging the plasterboard. Rotate all 6 clamping arms out using the levers then tighten the 6 screws to clamp and secure the unit.
  6. Connect the LED panel power connector.
  7. Attach the fascia to the body aligning the “HEATER” marking in the inside of the fascia with the “HEATER” marking on the HFL body and tighten screws avoid overtightening DO NOT use an electric drill or impact driver.
  8. Attach ducting to extract the air to the soffit or outer wall using 3m long flexible ducting, duct clamp and vent outlet grille provided.
    • Fix and tighten duct clamp firmly to hold the flexible duct to the unit and the outer wall vent.

ELECTRICAL WIRING DIAGRAM

  1. Ensure the power is switched “OFF” at the mains before commencing installation.
  2. Remove the cover on the back of the enclosure to access the terminals.
  3. Connect wires as per electrical wiring diagram and markings adjacent to terminal block.
  4. Replace the cover removed earlier.VIVO-FAN7291-Integrated-Bathroom-Heat-Fan-Light-fig-3
  • This unit uses PTC heating as a heat source. It also has an extract fan, a heater fan and an LED panel.
  • The remote switch operation is described below
  1. Lighting – “LIGHT” switch turns on and off the LED light panel
  2. Extract – “EXTRACT” switch On/Off. This unit can exhaust odours and steam in a quick and efficient way by turning on the “EXTRACT” switch.
  3. Heating – Left “HEAT 1” switch turns on PTC heater and blower fan (1400W)
  • Right “HEAT 2” switch boosts the heating power of the PTC heater (2000W).
  • The PTC heater and fan will not run if the left “HEAT 1” switch is off.

AIRFLOW BY DUCT LENGTH

LAMPS

  • LED panel – FAN7291: DC25-40V, 0.6A, 20W, 1900 lm, Cool White (4000K).
    • The light source of this luminaire is not replaceable when the light source reaches its end of life the whole luminaire should be replaced.

MAIN TECHNICAL PARAMETERS

Input| Power| Static Pressure| Free Air

Fan Performance

| Sound Level

@ 3m

| Hole-cutting Size| IP Rating| Dimensions

(W x H x D)

| **** Weight
---|---|---|---|---|---|---|---|---
220-240V AC

50Hz

| 2100W| 115Pa| 92 l/s, 330m3/hr| 49.5dB(A)| 590mm x 320mm| IPX2| 350mm x 630mm x 145mm| 5.6kg

LIST OF COMPONENTS SUPPLIED

VIVO Bathroom Heat Fan Light Unit 1 piece
Ø125mm Duct 3m Length 1 piece
Exterior Grille 1 piece
4 Gang Wall Switch 1 piece
Installation instruction and cutting template 1 piece

CLEANING

  • Switch off the power before commencing cleaning and wait until the heater cools down.
  • Regularly wipe front fascia with a soft cloth soaked with water or neutral detergent if required.
  • Clean the exhaust fan from dust and dirt with dry or wet cloth if required.
  • Clean the exhaust ducting kit and ensure airways are clean and there are no obstructions at the exit from the wall.

WARRANTY

  • This unit is warranted against defects in manufacturing and workmanship for a period of 5 years. The warranty does not extend to installation of the unit or any associated wiring or any damage caused by installation or wiring.
  • The installation must be conducted by a registered electrician and a suitable certificate of safety is to be issued by the electrician who installed the unit. Warranty claims will be voided unless a certificate of safety can be produced when required, prior to service or repair.

This warranty does not cover damages or loss caused by:

  1. Any consequential losses arising from incorrect installation or operation or maintenance of this product.
  2. Any consequential losses arising from incorrect wiring of this product.
  3. Any modifications or changes made to the unit, other than those recommended by the manufacturer.
  • Fill out the following details and file along with your purchase receipt and certificate of safety.
  • Model No.:
  • Purchased from:
  • Purchased date:
  • Instructions are subject to change without notice.
  • Distributed by Simx Limited
  • PO Box 14347, Panmure, Auckland 1741, New Zealand
  • e sales@simx.co.nz I www.manrose.co.nz

Documents / Resources

| V I V O FAN7291 Integrated Bathroom Heat Fan Light [pdf] Instruction Manual
FAN7291, FAN7291 Integrated Bathroom Heat Fan Light, Integrated Bathroom Heat Fan Light, Bathroom Heat Fan Light, Heat Fan Light, Fan Light, Light
---|---

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

V I V O User Manuals

Related Manuals