MITSUBISHI ELECTRIC MSZ-AY25VGKP Split-Type Air Conditioners Instruction Manual
- June 12, 2024
- Mitsubishi Electric
Table of Contents
- SPLIT-TYPE AIR CONDITIONERS
- SAFETY PRECAUTIONS
- DISPOSAL
- NAME OF EACH PART
- PREPARATION BEFORE OPERATION
- PREPARATION BEFORE OPERATION
- CLEANING
- Wi-Fi® INTERFACE SETTING UP
- SPECIFICATIONS
- WHEN YOU THINK THAT TROUBLE HAS OCCURRED
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
SPLIT-TYPE AIR CONDITIONERS
INDOOR UNIT
MSZ-AY25VGKP MSZ-AY35VGKP MSZ-AY42VGKP MSZ-AY50VGKP
MSZ-AY25VGK MSZ-AY35VGK MSZ-AY42VGK MSZ-AY50VGK
OPERATING INSTRUCTIONS
Manual Download
http://www.mitsubishielectric.com/ldg/ibim/
This manual is brief version. Go to the above website and choose language to download full version OPERATING INSTRUCTIONS and INSTALLATION MANUAL.
SAFETY PRECAUTIONS
Meanings of symbols displayed on indoor unit and/or outdoor unit
| WARNING
(Risk of fire)| This unit uses a flammable refrigerant.
If refrigerant leaks and comes in contact with fire or heating part, it will
create harmful gas and there is risk of fire.
---|---|---
| Read the OPERATING INSTRUCTIONS carefully before operation.
| Service personnel are required to carefully read the OPERATING INSTRUCTIONS
and INSTALLATION MANUAL before operation.
| Further information is available in the OPERATING INSTRUCTIONS, INSTALLATION
MANUAL, and the like.
- Since rotating parts and parts which could cause an electric shock are used in this product, be sure to read these “Safety Precautions” before use.
- Since the cautionary items shown here are important for safety, be sure to observe them.
- After reading this manual, keep it together with the installation manual in a handy place for easy reference.
- Wi-Fi® is a registered trademark of Wi-Fi Alliance®.
Marks and their meanings
WARNING : Incorrect handling could cause serious hazard, such as death, serious injury, etc. with a high probability.
CAUTION : Incorrect handling could cause serious hazard depending on the conditions.
Meanings of symbols used in this manual
: Be sure not to do.
: Be sure to follow the instruction.
: Never insert your finger or stick, etc.
: Never step onto the indoor/outdoor unit and do not put anything on them.
: Danger of electric shock. Be careful.
: Be sure to disconnect the power supply plug from the power outlet.
: Be sure to shut off the power.
: Risk of fire.
: Never touch with wet hand.
: Never splash water on the unit.
WARNING
| Do not connect the power cord to an intermediate point, use an extension cord, or connect multiple devices to a single AC outlet.
- This may cause overheating, fire, or electric shock.
Make sure the power plug is free of dirt and insert it securely into the outlet.
- A dirty plug may cause fire or electric shock.
Do not bundle, pull, damage, or modify the power cord, and do not apply heat or place heavy objects on it.
- This may cause fire or electric shock.
Do not turn the breaker OFF/ON or disconnect/connect the power plug during operation.
- This may create sparks, which can cause fire.
- After the indoor unit is switched OFF with the remote controller, make sure to turn the breaker OFF or disconnect the power plug.
Do not expose your body directly to cool air for a prolonged length of time.
- This could be detrimental to your health.
The unit should not be installed, relocated, disassembled, altered, or repaired by the user.
- An improperly handled air conditioner may cause fire, electric shock, injury, or water leakage, etc. Consult your dealer.
- If the power supply cord is damaged, it must be replaced by the manufacturer or its service agent in order to avoid a hazard.
When installing, relocating, or servicing the unit, make sure that no substance other than the specified refrigerant (R32) enters the refrigerant circuit.
- Any presence of foreign substance such as air can cause abnormal pressure rise and may result in explosion or injury.
- The use of any refrigerant other than that specified for the system will cause mechanical failure, system malfunction, or unit breakdown. In the worst case, this could lead to a serious impediment to securing product safety.
This appliance is not intended for use by persons (including children) with
reduced physical, sensory or mental capabilities, or lack of experience and
knowledge, unless they have been given supervision or instruction concerning
use of the appliance by a person responsible for their safety.
Children should be supervised to ensure that they do not play with the
appliance.
| Do not insert your finger, a stick, or other objects into the air inlet or outlet.
- This may cause injury, since the fan inside rotates at high speeds during operation.
| In case of an abnormal condition (such as a burning smell), stop the air conditioner and disconnect the power plug or turn the breaker OFF.
- A continued operation in the abnormal state may cause a malfunction, fire, or electric shock. In this case, consult your dealer.
| When the air conditioner does not cool or heat, there is a possibility of refrigerant leakage. If any refrigerant leakage is found, stop operations and ventilate the room well and consult your dealer immediately. If a repair involves recharging the unit with refrigerant, ask the service technician for details.
- The refrigerant used in the air conditioner is not harmful. Normally, it does not leak. However, if refrigerant leaks and comes in contact with fire or heating part of such a fan heater, kerosene heater, or cooking stove, it will create harmful gas and there is risk of fire.
The user should never attempt to wash the inside of the indoor unit. Should the inside of the unit require cleaning, contact your dealer.
- Unsuitable detergent may cause damage to plastic material inside the unit, which may result in water leakage. Should detergent come in contact with electrical parts or the motor, it will result in a malfunction, smoke, or fire.
- The appliance shall be stored in a room without continuously operating ignition sources (for example: open flames, an operating gas appliance or an operating electric heater).
- Be aware that refrigerants may not contain an odour.
- Do not use means to accelerate the defrosting process or to clean the appliance, other than those recommended by the manufacturer.
- Do not pierce or burn.
The indoor unit must be installed in rooms which exceed the floor space specified. Please consult your dealer.
- AY25/35: 2.0 m², AY42: 2.5 m², AY50: 3.2 m²
| This appliance is intended to be used by expert or trained users in shops, in light industry and on farms, or for commercial use by lay persons.
CAUTION
| Do not touch the air inlet or the aluminum fins of the indoor/outdoor unit.
- This may cause injury.
Do not use insecticides or flammable sprays on the unit.
- This may cause a fire or deformation of the unit.
Do not expose pets or houseplants to direct airflow.
- This may cause injury to the pets or plants.
Do not place other electric appliances or furniture under the indoor/ outdoor unit.
- Water may drip down from the unit, which may cause damage or malfunction.
Do not leave the unit on a damaged installation stand.
- The unit may fall and cause injury.
Do not step on an unstable bench to operate or clean the unit.
- This may cause injury if you fall down.
Do not pull the power cord.
- This may cause a portion of the core wire to break, which may cause overheating or fire.
Do not charge or disassemble the batteries, and do not throw them into a fire.
- This may cause the batteries to leak, or cause a fire or explosion.
Do not operate the unit for more than 4 hours at high humidity (80% RH or more) and/or with windows or outside door left open.
- This may cause the water condensation in the air conditioner, which may drip down, wetting or damaging the furniture.
- The water condensation in the air conditioner may contribute to growth of fungi, such as mold.
Do not use the unit for special purposes, such as storing food, raising animals, growing plants, or preserving precision devices or art objects.
- This may cause deterioration of quality, or harm to animals and plants.
Do not expose combustion appliances to direct airflow.
- This may cause incomplete combustion.
Never put batteries in your mouth for any reason to avoid accidental ingestion.
- Battery ingestion may cause choking and/or poisoning.
| Before cleaning the unit, switch it OFF and disconnect the power plug or turn the breaker OFF.
- This may cause injury, since the fan inside rotates at high speeds during operation.
When the unit will be unused for a long time, disconnect the power plug or turn the breaker OFF.
- The unit may accumulate dirt, which may cause overheating or fire.
Replace all batteries of the remote controller with new ones of the same type.
- Using an old battery together with a new one may cause overheating, leakage, or explosion.
If the battery fluid comes in contact with your skin or clothes, wash them thoroughly with clean water.
- If the battery fluid comes in contact with your eyes, wash them thoroughly with clean water and immediately seek medical attention.
Ensure that the area is well-ventilated when the unit is operated together with a combustion appliance.
- Inadequate ventilation may cause oxygen starvation.
Turn the breaker OFF when you hear thunder and there is a possibility of a lightning strike.
- The unit may be damaged if lightning strikes.
After the air conditioner is used for several seasons, perform inspection and maintenance in addition to normal cleaning.
- Dirt or dust in the unit may create an unpleasant odor, contribute to growth of fungi, such as mold, or clog the drain passage, and cause water to leak from the indoor unit. Consult your dealer for inspection and maintenance, which require specialized knowledge and skills.
| Do not operate switches with wet hands.
- This may cause electric shock.
Do not clean the air conditioner with water or place an object that contains water, such as a flower vase, on it.
- This may cause fire or electric shock.
| Do not step on or place any object on the outdoor unit.
- This may cause injury if you or the object falls down.
To use this unit correctly and safely, be sure to read these operating instructions before use.
IMPORTANT
Dirty filters cause condensation in the air conditioner which will
contribute to the growth of fungi such as mold. It is therefore recommended to
clean air filters every 2 weeks.
Before starting the operation, ensure that the horizontal vanes are in the
closed position. If operation starts when the horizontal vanes are in the open
position, they may not return to the correct position.
For installation
WARNING
| Consult your dealer for installing the air conditioner.
- It should not be installed by the user since installation requires specialized knowledge and skills. An improperly installed air conditioner may cause water leakage, fire, or electric shock.
Provide a dedicated power supply for the air conditioner.
- A non-dedicated power supply may cause overheating or fire.
Do not install the unit where flammable gas could leak.
- If gas leaks and accumulates around the outdoor unit, it may cause an explosion.
| Earth the unit correctly.
- Do not connect the earth wire to a gas pipe, water pipe, lightning rod, or a telephone earth wire. Improper earthing may cause electric shock.
CAUTION
| Install an earth leakage breaker depending on the installation location of the air conditioner (such as highly humid areas).
- ****If an earth leakage breaker is not installed, it may cause electric shock.
Ensure that the drain water is properly drained.
- If the drain passage is improper, water may drip down from the indoor/outdoor unit, wetting and damaging the furniture.
In case of an abnormal condition
Immediately stop operating the air conditioner and consult your dealer.
For Wi-Fi® interface
WARNING
(Improper handling may have serious consequences, including serious injury or death.)
| This appliance can be used by children aged from 8 years and above and
persons with reduced physical, sensory or mental capabilities or lack of
experience and knowledge if they have been given supervision or instruction
concerning use of the appliance in a safe way and understand the hazards
involved.
Children shall not play with the appliance. Cleaning and user maintenance
shall not be made by children without supervision.
Do not use the Wi-Fi® interface nearby the medical electrical equipment or
people who have a medical device such as a cardiac pacemaker or an implantable
cardioverter-defibrillator.
- It can cause an accident due to malfunctions of the medical equipment or device.
Do not install the Wi-Fi® interface nearby the automatic control devices such as automatic doors or fire alarms.
- It can cause accidents due to malfunctions.
| Do not touch the Wi-Fi® interface with wet hands.
- It can cause damage to the device, electric shock, or fire.
| Do not splash water on the Wi-Fi® interface or use it in a bathroom.
- It can cause damage to the device, electric shock, or fire.
| When the Wi-Fi® interface is dropped, or the holder or cable is damaged, disconnect the power supply plug or turn the breaker OFF.
- It may cause fire or electric shock. In this case, consult your dealer.
CAUTION
(Improper handling may have consequences, including injury or damage to building.)
| Do not step on unstable stepstool to set up or clean the Wi-Fi® interface.
- It may cause injury if you fall down.
Do not use the Wi-Fi® interface nearby other wireless devices, microwaves, cordless phones, or facsimiles.
- It can cause malfunctions.
DISPOSAL
Fig. 1
To dispose of this product, consult your dealer.
Note:
This symbol mark is for EU countries only.
This symbol mark is according to the directive 2012/19/EU Article 14
Information for users and Annex IX, and/or to the directive 2006/66/EC Article
20 Information for end-users and Annex II.
Your MITSUBISHI ELECTRIC product is designed and manufactured with high
quality materials and components which can be recycled and/or reused.
This symbol means that electrical and electronic equipment, batteries and
accumulators, at their end-of-life, should be disposed of separately from your
household waste.
If a chemical symbol is printed beneath the symbol (Fig. 1), this chemical
symbol means that the battery or accumulator contains a heavy metal at a
certain concentration. This will be indicated as follows:
Hg: mercury (0.0005%), Cd: cadmium (0.002%), Pb: lead (0.004%)
In the European Union there are separate collection systems for used
electrical and electronic products, batteries and accumulators.
Please, dispose of this equipment, batteries and accumulators correctly at
your local community waste collection/recycling centre.
Please, help us to conserve the environment we live in!
NAME OF EACH PART
Indoor unit
-
Air cleaning filter
(V Blocking Filter) -
Air filter
-
Front panel
-
Air inlet
-
Air purifying device
(VGKP type only) -
Wi-Fi® interface
-
Emergency operation switch *2
-
Spec name plate *1
-
Horizontal vane
-
Fan guard
-
Air outlet
-
Heat exchanger
-
Operation indicator lamp
-
Remote control receiving section
Outdoor unit
- Air inlet (back and side)
- Spec name plate *1
- Refrigerant piping
- Drainage hose
- Air outlet
- Drain outlet
Outdoor units may be different in appearance.
*1 The manufacturing year and month are indicated on the spec name plate.
*2 When the remote controller cannot be used…
Emergency operation can be activated by pressing the emergency operation
switch (E.O. SW) on the indoor unit.
Each time the E.O. SW is pressed, the operation changes in the following
order:
-
Emergency
COOL -
Emergency
HEAT -
Stop
: Lit
: Not lit
Set temperature : 24°C
Fan speed : Medium
Horizontal vane : Auto
PREPARATION BEFORE OPERATION
Before operation: Insert the power supply plug into the power outlet and/or turn the breaker on.
Installing the remote controller batteries
- Remove the front lid.
- Insert the negative pole of AAA alkaline batteries first.
- Install the front lid.
- Press RESET.
Setting current time
-
Press CLOCK.
-
Press either the TIME button or the TIMER buttons to set the time.
Each press changes the clock 1 minute forward/backward (10 minutes when pressed longer). -
Press the DAY button to set the day.
-
Press CLOCK again.
● OPERATING INSTRUCTIONS ●
PREPARATION BEFORE OPERATION
Remote controller
-
Battery replacement indicator
-
Signal transmitting section
Distance of signal : About 6 m
Beep(s) is (are) heard from the indoor unit when the signal is received. -
OFF/ON (stop/operate) button
-
FAN speed control button
-
WIDE VANE button
-
VANE control button
-
PURIFIER button (VGKP type only)
-
TIME, TIMER set buttons forward button backward button
-
WEEKLY TIMER set buttons
-
RESET button
-
Lid
Slide the lid down to open the remote controller. Slide it down further to get to the weekly timer buttons. -
CLOCK button
-
SELF CLEAN button
-
NIGHT MODE button
-
i-save button
-
ECONO COOL button
-
Operation select button
-
Temperature buttons
-
Operation display section
TIME, TIMER set button
Change the time forward/backward
(ON timer) : The unit turns ON at the set time.
(OFF timer) : The unit turns OFF at the set time.
Press (forward) and (backward) to set the time of timer.
WEEKLY TIMER set buttons
Press to enter the weekly timer setting mode.
Press and to select setting day and number.
Press , , and to set ON/OFF, time, and temperature.
Press to complete and transmit the weekly timer setting.
Press to turn the weekly timer ON. ( lights.)
Press again to turn the weekly timer OFF. ( goes out.)
OFF/ON (stop/operate) button
Operation select button
Temperature buttons
Each press raises or lowers the temperature by 1°C.
FAN speed control button
Left-right airflow control button
Up-down airflow control button
ECONO COOL button
The set temperature and the airflow direction are automatically changed by the
microprocessor.
i-save button
A simplified set back function enables to recall the preferred (preset)
setting with a single push of the button. Press the button again and you can
go back to the previous setting in an instance.
NIGHT MODE button
NIGHT MODE operation changes the brightness of the operation indicator,
disables the beep sound and limits the noise level of the outdoor unit.
AIR PURIFYING button
In the AIR PURIFYING operation, the indoor unit built-in device reduces
airborne fungi, viruses, mold, and allergens.
CLEANING
Instructions:
-
Switch off the power supply or turn off the breaker before cleaning.
-
Be careful not to touch the metal parts with your hands.
-
Do not use benzine, thinner, polishing powder, or insecticide.
-
When dirt stands out, wash it with kitchen neutral detergent diluted with lukewarm water to the specified concentration, then wipe off the detergent with a damp towel.
-
Do not use a scrubbing brush, a hard sponge, or the like.
-
Do not soak or rinse the horizontal vane.
-
Do not use water hotter than 50°C.
-
Do not expose parts to direct sunlight, heat, or fire to dry.
-
Do not apply excessive force on the fan as it may cause cracks or breakage.
-
-
[1] Front panel
1. Hinge
2. Hole
-
Lift the front panel until a “click” is heard.
-
Hold the hinges and pull to remove as shown in the illustration above.
• Wipe with a soft dry cloth or rinse it with water.
• Do not soak it in water for more than two hours.
• Dry it well in shade before installing it. -
Install the front panel by following the removal procedure in reverse. Close the front panel securely and press the positions indicated by the arrows.
[2] Air filter (Air purifying filter)
- Clean every 2 weeks
- Remove dirt by a vacuum cleaner, or rinse with water.
- After washing with water, dry it well in shade.
[3] Air purifying device (VGKP type only)
Every 3 months:
- Remove dirt by a vacuum cleaner.
When dirt cannot be removed by vacuum cleaning:
- Soak the filter together with its frame in lukewarm water and rinse it.
- After washing, dry it well in shade.
[4] Air cleaning filter
(V Blocking Filter, VGKP type: option)
Every 3 months:
- Remove dirt by a vacuum cleaner.
When dirt cannot be removed by vacuum cleaning:
- Soak the filter and its frame in lukewarm water before rinsing it.
- After washing, dry it well in shade. Install all tabs of the air filter.
Every year:
- Replace it with a new air cleaning filter for best performance.
- Parts Number MAC-2470FT-E
Pull to remove from the air filter
Important
- Clean the filters regularly for best performance and to reduce power consumption.
- Dirty filters cause condensation in the air conditioner which will contribute to the growth of fungi such as mold. It is therefore recommended to clean air filters every 2 weeks.
This information is based on REGULATION (EU) No 528/2012
MODEL NAME| Treated Article
(Parts name)| Active Substances
(CAS No.)| Property| Instruction for Use
(Safe handling information)
---|---|---|---|---
MSZ-AY25/35/42/50VGKP
MSZ-AY25/35/42/50VGK| FILTER| Dimethyloctadecyl[3-(trimethoxysilyl)
propyl]ammonium chloride
(27668-52-6)
Silver sodium hydrogen zirconium phosphate
(265647-11-8)
2-octyl-2H-isothiazol-3-one (OIT)
(26530-20-1)| Antivirus
Antibacterial
Antimold|
- Use this product in line with the instruction manual indications and for the intended purpose only.
- Do not put into mouth. Keep away from children.
MAC-2470FT-E| FILTER| Dimethyloctadecyl[3-(trimethoxysilyl) propyl]ammonium
chloride
(27668-52-6)| Antivirus
Antibacterial
Antimold|
- Use this product in line with the instruction manual indications and for the intended purpose only.
- Do not put into mouth. Keep away from children.
Wi-Fi® INTERFACE SETTING UP
- Front panel
- Wi-Fi® interface
This Wi-Fi® interface, communicates the status information and controls the commands from the MELCloud by connecting to the indoor unit.
Note:
-
Set up a connection between the Wi-Fi® interface and the Router. Refer to the full version and SETUP QUICK REFERENCE GUIDE provided with the unit.
-
For full version, please go to the website below.
http://www.mitsubishielectric.com/ldg/ibim/ -
For MELCloud User Manual, please go to the website below.
https://www.melcloud.com/Support -
-
SPECIFICATIONS
Model| Indoor|
MSZ-AY25VGK(P)
| MSZ-AY35VGK(P)| MSZ-AY42VGK(P)|
MSZ-AY50VGK(P)
---|---|---|---|---|---
Outdoor|
MUZ-AY25VG(H)
| MUZ-AY35VG(H)| MUZ-AY42VG(H)|
MUZ-AY50VG(H)
Function|
Cooling
| Heating| Cooling| Heating| Cooling| Heating| Cooling|
Heating
Power supply|
~ /N, 230 V, 50 Hz
Capacity|
kW
| 2.5| 3.2| 3.5| 4.0| 4.2| 5.2| 5.0|
5.5
Input|
kW
| 0.60| 0.78| 0.99| 1.03| 1.30| 1.39| 1.54|
1.47
Weight| Indoor|
kg
|
VGKP: 11, VGK: 10.5
Outdoor|
kg
| 27| 28.5| 34|
40.5
Refrigerant filling capacity (R32) |
kg
| 0.55| 0.55| 0.70|
1.00
IP code| Indoor|
IP 20
Outdoor|
IP 24
Permissible excessive operating pressure| LP ps|
MPa
|
2.77
HP ps|
MPa
|
4.17
Noise level (SPL)| Indoor (Super High/ High/Med./Low/Silent)|
dB(A)
| 42/36/30/ 24/18| 45/39/34/ 24/18| 42/36/30/ 24/18| 45/38/31/ 24/18| 42/38/34/ 29/21| 45/40/35/ 29/21| 44/40/36/ 33/28|
48/43/38/ 33/28
Outdoor|
dB(A)
| 47| 48| 49| 50| 50| 51| 52|
52
Indoor specification for multi connection REGULATION (EU) 2016/2281
Model| Indoor|
MSZ-AY25VGK(P)
| MSZ-AY35VGK(P)| MSZ-AY42VGK(P)|
MSZ-AY50VGK(P)
---|---|---|---|---|---
Capacity| Cooling| Sensible|
kW
| 2.30| 3.08| 3.23|
3.70
Latent|
kW
| 0.20| 0.42| 0.97|
1.30
Heating|
kW
| 2.90| 4.00| 4.80|
5.70
Input|
kW
| 0.026| 0.026| 0.032|
0.032
Noise level
(Sound power level)| Super High/High/Med./Low/Silent|
dB(A)
| 57/51/45/39/34| 57/51/45/39/34| 57/53/49/44/36|
58/54/50/47/42
Guaranteed operating range
| Indoor| Outdoor
---|---|---
Cooling| Upper limit| 32°C DB
23°C WB| 46°C DB
—
Lower limit
| 21°C DB
15°C WB| -10°C DB
—
Heating| Upper limit| 27°C DB
—| 24°C DB
18°C WB
Lower limit
| 20°C DB
—| -20°C DB
-21°C WB
DB: Dry Bulb
WB: Wet Bulb
Wi-Fi® interface
Model|
MAC-577IF2-E
---|---
Input Voltage|
DC12.7 V (from indoor unit)
Power consumption|
MAX. 2 W
Size H×W×D (mm)|
73.5×41.5×18.5
Weight (g) (including cable)|
46
Transmitter power level (MAX.)|
20 dBm @IEEE 802.11b
RF channel|
1ch ~ 13ch (2412~2472 MHz)
Radio protocol|
IEEE 802.11b/g/n (20)
Encryption|
AES
Authentication|
WPA2-PSK
Software Version|
XX.00
For Declaration of Conformity, please go to the website below.
http://www.mitsubishielectric.com/ldg/ibim/
Note:
Rating condition
Cooling — Indoor: 27°C DB, 19°C WB
Outdoor: 35°C DB
Heating — Indoor: 20°C DB
Outdoor: 7°C DB, 6°C WB
WHEN YOU THINK THAT TROUBLE HAS OCCURRED
In the following cases, stop using the air conditioner and consult your dealer.
- When water leaks or drips from the indoor unit.
- When the operation indicator lamp blinks.
- When the breaker trips frequently.
- The remote control signal is not received in a room where an electronic ON/OFF type fluorescent lamp (inverter-type fluorescent lamp, etc.) is used.
- Operation of the air conditioner interferes with radio or TV reception. An amplifier may be required for the affected device.
- When an abnormal sound is heard.
- When any refrigerant leakage is found.
Wi-Fi® interface setting information
Indoor unit model name|
---|---
Indoor unit serial number|
Outdoor unit model name|
Outdoor unit serial number|
Wi-Fi® interface MAC address (MAC)|
Wi-Fi® interface serial number (ID)|
Wi-Fi® interface SSID (SSID)|
Wi-Fi® interface KEY (KEY)|
System commissioning date|
Wi-Fi® interface installation date|
Installer contact details
Name|
---|---
Telephone number|
MEMO
Name of Importer:
Mitsubishi Electric Europe B.V.
Capronilaan 46, 1119 NS, Schiphol Rijk, The Netherlands
French Branch
2, Rue De L’Union, 92565 RUEIL MAISON Cedex
German Branch
Mitsubishi-Electric-Platz 1 40882 Ratingen North Rhine-Westphalia Germany
Belgian Branch
8210 Loppem, Autobaan 2, Belgium
Irish Branch
Westgate Business Park, Ballymount Road, Upper Ballymount, Dublin 24, Ireland
Italian Branch
Palazzo Sirio Ingresso 1, Viale Colleoni, 7, 20864 Agrate Brianza (MI), Italy
Norwegian Branch
Gneisveien 2D, 1914 Ytre Enebakk, Norway
Portuguese Branch
Avda. do Forte 10, 2794-019 Carnaxide, Lisbon, Portugal
Spanish Branch
Av. Castilla, 2 Parque Empresarial San Fernando – Ed. Europa, 28830 San
Fernando de Henares (Madrid), Spain
Scandinavian Branch
Hammarbacken 14, P.O. Box 750, SE-19127, Sollentuna, Sweden
UK Branch
Travellers Lane, Hatfield, Hertfordshire, AL10 8XB. England, UK
Polish Branch
Krakowska 48, PL-32-083 Balice, Poland
MITSUBISHI ELECTRIC TURKEY ELEKTRİK ÜRÜNLERI A.Ş
Şerifali Mahallesi Kale Sokak No: 41 34775 Ümraniye, İstanbul, Turkey
UK DECLARATION OF CONFORMITY
MITSUBISHI ELECTRIC AIR CONDITIONING SYSTEMS MANUFACTURING TURKEY JOINT
STOCK COMPANY.
Manisa OSB 4.Kisim Kecilikoyosb Mah.
Ahmet Nazif Zorlu Bulvari No:19 Yunusemre – Manisa.
hereby declares under its sole responsibility that the air conditioner(s) and heat pump(s) for use in residential, commercial, and light-industrial environments described below:
MITSUBISHI ELECTRIC, MSZ-AY25VGKP/MUZ-AY25VG, MSZ-AY25VGKP/MUZ-AY25VGH,
MSZ-AY25VGK/MUZ-AY25VG, MSZ-AY25VGK/MUZ-AY25VGH
MSZ-AY35VGKP/MUZ-AY35VG, MSZ-AY35VGKP/MUZ-AY35VGH, MSZ-AY35VGK/MUZ-AY35VG,
MSZ-AY35VGK/MUZ-AY35VGH
MSZ-AY42VGKP/MUZ-AY42VG, MSZ-AY42VGKP/MUZ-AY42VGH, MSZ-AY42VGK/MUZ-AY42VG,
MSZ-AY42VGK/MUZ-AY42VGH
MSZ-AY50VGKP, MSZ-AY50VGK
is/are in conformity with provisions of the following UK legislation
Radio Equipment Regulations 2017
The Supply of Machinery (Safety)Regulations 2008
The Restriction of the Use of Certain Hazardous Substances in Electrical
and Electronic Equipment Regulations 2012
Issued: 1 July, 2022 Kenichi SAITO
TURKEY Manager, Quality Assurance Department
EU DECLARATION OF CONFORMITY
MITSUBISHI ELECTRIC AIR CONDITIONING SYSTEMS MANUFACTURING TURKEY JOINT
STOCK COMPANY.
Manisa OSB 4.Kisim Kecilikoyosb Mah.
Ahmet Nazif Zorlu Bulvari No:19 Yunusemre – Manisa.
hereby declares under its sole responsibility that the air conditioner(s) and heat pump(s) for use in residential, commercial, and light-industrial environments described below:
MITSUBISHI ELECTRIC, MSZ-AY25VGKP/MUZ-AY25VG, MSZ-AY25VGKP/MUZ-AY25VGH,
MSZ-AY25VGK/MUZ-AY25VG, MSZ-AY25VGK/MUZ-AY25VGH
MSZ-AY35VGKP/MUZ-AY35VG, MSZ-AY35VGKP/MUZ-AY35VGH, MSZ-AY35VGK/MUZ-AY35VG,
MSZ-AY35VGK/MUZ-AY35VGH
MSZ-AY42VGKP/MUZ-AY42VG, MSZ-AY42VGKP/MUZ-AY42VGH, MSZ-AY42VGK/MUZ-AY42VG,
MSZ-AY42VGK/MUZ-AY42VGH
MSZ-AY50VGKP, MSZ-AY50VGK
is/are in conformity with provisions of the following Union harmonisation legislation.
2014/53/EU: Radio Equipment Directive
2006/42/EC: Machinery Directive
2011/65/EU, (EU) 2015/863 and (EU) 2017/2102: RoHS Directive
Issued: 1 July, 2022 Kenichi SAITO
TURKEY Quality Assurance Department
MITSUBISHI ELECTRIC CORPORATION
HEAD OFFICE: TOKYO BUILDING, 2-7-3, MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN
DG79A01ZL01A
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>