Installation and Safety Instructions

Two wire groups: Group A and Group B

Group A:

  • Connect to Black House Wire
  • Parallel Wire (round & smooth)
  • Wire Colors: White or Grey with Tracer, Brown, Gold or Black without Tracer

Group B:

  • Connect to White House Wire
  • Parallel Wire (square & ridged)
  • Wire Colors: White or Grey without Tracer, Brown, Gold or Black with Tracer
  • Note: When using parallel wire (SPT-I & SPT-2), the tracer wire is square-shaped or ridged, and the less tracer wire is round in shape or smooth (seen best when viewed from wire end).
  • Figure (not provided in the text)

Product Usage Instructions

  1. Identify the house wires:
    Black House Wire and White House Wire.

  2. Separate the fixture wires into two groups:
    Group A and Group B.

  3. Group A Connection

    • Take the fixture wire(s) from Group A.
    • Place the fixture wire(s) evenly against the black wire from the outlet box.
    • Do NOT twist the wires together before using wire connectors.
  4. Group B Connection:

    • Take the fixture wire(s) from Group B.
    • Connect the fixture wire(s) to the white wire from the outlet box.
    • Again, do NOT twist the wires together before using wire connectors.
  5. Wire Connector Installation:

    • Fit a wire connector over the wires of each group.
    • Screw the connector clockwise until you feel firmness.
  6. Follow any additional installation and safety instructions provided in the user manual.

Please note that the text provided includes translations in Spanish (NOTA) and French (NOIR and BLANC). However, since the main text is in English, the usage instructions are provided in English.

FOR YOUR SAFETY

WARNING : BE SURE THE ELECTRICITY TO THE WIRES YOU ARE WORKING ON IS SHUT OFF; EITHER THE FUSE IS REMOVED OR THE CIRCUIT BREAKER IS SHUT OFF.

GENERAL
You don’t need special tools to install this fixture. Be sure to follow the steps in the order given. Under no circumstances should a fixture be hung on house electrical wires, nor should a swag type fixture be installed on a ceiling which contains a radiant type heating system. Read instructions carefully. If you are unclear as to how to proceed, consult a qualified electrician.

NOTE: Proper wiring is essential for the safe operation of this fixture.

**FIXTURE ASSEMBLY

**

Carefully remove the fixture from the carton and check that all parts are included as shown in the figure. Be careful not to misplace any of the screws or parts, which are needed to install this fixture.

INSTALLATION

  • STEP 1: While supporting the fixture, connect the electrical wires. If your post has a ground wire (green or bare copper), connect the fixture ground wire to it. If not, consult your electrician for proper grounding. After the wires are connected, tuck them carefully inside the post (A).
  • STEP 2: Place the fixture onto the pole, and secure it with the 3 mounting screws (C).

GROUNDING INSTRUCTIONS

  • STEP 1: Insert the green grounding screw into the hole with two raised dimples on the mounting bar. Wrap the ground wire from the fixture (if supplied) around the green grounding screw, then connect it to ground wire from the outlet box (if not fixed on the outlet box) using a wire connector (not supplied). If ground wire from the fixture is not supplied, wrap the ground wire (if not fixed on the outlet box) from the outlet box around the green grounding screw and tighten it.
    NEVER CONNECT GROUND WIRE TO BLACK OR WHITE POWER SUPPLY WIRES.

  • STEP 2: Take note of the color of the wire(s) on your fixture. Identify which group your fixture wire(s) falls into and connect the wires according to the directions below:
    GROUP A:

Connect to Black House Wire

| GROUP B:

Connect to White House Wire

---|---
BLACK| WHITE
PARALLEL WIRE (round & smooth)| PARALLEL WIRE (square & ridged)
WHITE OR GREY WITH TRACER| WHITE OR GREY WITHOUT TRACER
BROWN, GOLD OR BLACK WITHOUT TRACER| BROWN, GOLD OR BLACK WITH TRACER

NOTE: When parallel wire (SPT-I & SPT-2) is used, the tracer wire is square shaped or ridged and the less tracer wire is round in shape or smooth (seen best when viewed from wire end.)

  • STEP 3: Take your fixture wire(s) from group A and place evenly against the black wire from the outlet box. Do NOT twist wires together before using wire connectors.
  • STEP 4: Fit a wire connector over the wires and screw the connector clockwise until you feel firmness.
    • The line art shown may not exactly match the fixture enclosed. However, the installations do apply to this fixture
  • STEP 5: Try gently to pull the connector off the wires. If you can pull the connector off, carefully re-do steps 3 and 4 as above, and check again for a firm connection.
  • STEP 6: Connect the fixture wire from group B to the white wire from the outlet box in the same manner. Make sure no bare wires can be seen outside wire connectors.

FINAL ASSEMBLY

  • STEP 1: Take off the roof (F) from the cage (D) by loosening mounting screws (E).
  • STEP 2: Install Bulb E26 medium base (not included). Do not exceed maximum wattage rating.
  • STEP 3: Attach the roof (F) back to the cage (D) by mounting screws (E).

CLEANING

To clean, wipe fixture with a soft cloth. Clean glass with a mild soap. Do not use abrasive materials such as scouring pads or powders, steel wool or abrasive paper.

ORDERING PARTS
Keep this sheet for future reference, and in case you need to order replacement parts. Be sure to use exact wording from illustration when ordering parts.

© Copyright 2022 Satco Products, Inc. 8/22 v1.0