ads-tec MMT8000 Series Machine Mounted Terminals Instruction Manual
- June 1, 2024
- ads-tec
Table of Contents
- ads-tec MMT8000 Series Machine Mounted Terminals
- Product Information
- Product Usage Instructions
- FAQs
- Device description
- General safety instructions
- Scope of delivery
- Installation
- Interfaces
- Interfaces of transmitter module
- Operation
- Maintenance, cleaning and disposal
- Technical data
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
ads-tec MMT8000 Series Machine Mounted Terminals
Specifications
- Product Name: Machine Mounted Terminals / Machine Mounted Displays
- Series: MMT8000 series / MMD8000 series
- Version: 3.6
Product Information
Device Description
The MMT8000 series MMD8000 series are machine-mounted terminals and displays designed for industrial use. They provide important information about the product, including its intended use, safety precautions, installation guidelines, utilization instructions, maintenance requirements, and disposal procedures.
General Safety Instructions
The instruction manual contains essential safety information related to the documentation, liability, manufacturer details, device documentation, symbols, data, figures, trademarks, copyright, standards, conformity, and explanation of safety instructions.
Scope of Delivery
The package includes the necessary components for installation. Optional scope of delivery items may be available separately.
Installation
The installation process involves various steps such as adjusting inclination angles, preparing the connecting tube, cable routing, mounting options with different adapters (support arm adapter, crosspiece adapter, VESA 75 adapter, IP69K adapter), and attaching service slot covers.
Interfaces
The product features various interfaces for connectivity.
Details about interfaces for MMT and MMD series are provided along with
information on maximum cable lengths and earthing requirements.
Product Usage Instructions
1. Pre-Installation Checks
Before starting the installation process, ensure all components are included in the package and verify that the area of installation meets the environmental conditions specified in the manual.
2. Installation Process
Follow the step-by-step instructions provided in the manual for installing the device. Pay special attention to details such as adjusting inclination angles, choosing the appropriate mounting adapter, and ensuring proper cable routing.
3. Powering On the Device
Once the device is securely installed, connect the power source according to the guidelines provided. Power on the device and follow any initial setup procedures if required.
4. Interface Connectivity
If connecting external devices or peripherals to the interfaces of the MMT/MMD series, refer to the interface section in the manual for proper connection methods and maximum cable lengths.
5. Maintenance and Care
Regularly inspect the device for any signs of damage or wear.
Follow the maintenance guidelines provided in the manual to ensure optimal
performance and longevity of the product.
FAQs
- Q: Where can I download the instruction manual?
- A: The instruction manual can be downloaded from www.ads-tec.com in the Download area.
“`
Translation of the original instruction manual Version 3.6 Updated 2024-01-19
Instruction manual
Machine Mounted Terminals / Machine Mounted Displays MMT8000 series / MMD8000
series
MMT8000 series / MMD8000 series
v3.6
2
Read these instructions carefully before using and store for future reference. These instructions contain important information about the product, in particular about its intended use, safety, installation, utilisation, maintenance and disposal. Hand over the instructions to the user following installation of the product, and pass the manual on to the new user if the product is resold. These instructions can be downloaded from: www.ads-tec.com in the Download area.
Publisher ads-tec Industrial IT GmbH Heinrich-Hertz-Straße 1 72622 Nürtingen Germany
Phone: Internet: E-mail:
+49 7022 2522-0 www.ads-tec.com mailbox@ads-tec.de
© ads-tec Industrial IT GmbH · Heinrich-Hertz-Str. 1 · 72622 Nürtingen · Germany
MMT8000 series / MMD8000 series
© ads-tec Industrial IT GmbH · Heinrich-Hertz-Str. 1 · 72622 Nürtingen · Germany
MMT8000 series / MMD8000 series
v3.6
5
Device description
The Machine Mounted Terminal (MMT) and Machine Mounted Display (MMD) are designed for the control and visualisation of production processes in the pharmaceutical, foodstuff, beverage and chemical industry. In the case of the MMT, the processing unit is integrated in the housing, making an external PC unnecessary for control (Fig. 1: Use of MMT and MMD). The MMD is a display which can be controlled by an external computer, e.g. from the existing industrial computer environment. With the MMD, cables can be used for distances of up to 15 m between the display and computer. The optional HDBaseTTM Extender Kit has been developed to bridge greater distances of up to 100 m. MMT and MMD are both available in the 17 and 24 inch format.
Figure 1: Use of MMT and MMD
© ads-tec Industrial IT GmbH · Heinrich-Hertz-Str. 1 · 72622 Nürtingen ·
Germany
MMT8000 series / MMD8000 series
v3.6
6
The MMT/MMD8000 series has been specifically designed to meet strict hygiene
conditions according to EHEDG (European Hygienic Engineering & Design Group)
and GMP (Good Manufacturing Practice) guidelines.
This is achieved by the stainless steel housing of the device being completely
closed, having rounded edges and no external screws. This allows the device to
be cleaned simply and effectively. The device has no fan, which means that the
primary source of contamination is not present. Due to its robust, compact
design, the device can also be operated under demanding environmental
conditions. All necessary cables are routed to the device through the
connecting tube so that there are no exposed cables in the operating room.
Thanks to the very latest multi-touch technology, the full-HD display with a
maximum resolution of 1920×1080 pixels can be operated conveniently by
touching and also by means of swiping and dragging movements. Operation with
special gloves is also possible. Additionally, a freely configurable key
module is available which enables e.g. individual production processes to be
started and stopped by simply pressing keys or by operating a switch. An
emergency-stop switch can also be integrated in this module.
Both the MMT and MMD can be mounted either on a stand or on a support arm,
i.e. stand or suspended mounting.
Figure 2: Mounting on support arm and stand
In addition to the T-piece support arm adapter, a crosspiece support arm
adapter is also available (Fig. 3). This allows two monitors to be mounted one
above the other.
Figure 3: Crosspiece adapter
© ads-tec Industrial IT GmbH · Heinrich-Hertz-Str. 1 · 72622 Nürtingen ·
Germany
MMT8000 series / MMD8000 series
v3.6
7
By simply turning and tilting the device and the key module, each device can be adjusted during operation so that the user can view it at the optimum angle (Fig. 4).
Figure 4: Turning and tilting Alternatively, ADS-TEC also offers a VESA
adapter which can be used to connect the device to a VESA 75 mounting system
(Fig. 5).
Figure 5: VESA adapter For applications with increased IP protection
requirements, ADS-TEC offers variants with IP69K:
Figure 6: Variants with IP69K
© ads-tec Industrial IT GmbH · Heinrich-Hertz-Str. 1 · 72622 Nürtingen ·
Germany
MMT8000 series / MMD8000 series
v3.6
8
General safety instructions
2.1 Information about documentation
2.1.1 General remark
This instruction manual is intended to ensure safe and efficient handling and
operation of IT Infrastructure products. The instruction manuals must be read
carefully by personnel before commencing any type of work. All of the safety
instructions and handling instructions given in the manual must be obeyed in
order to ensure that work is carried out safely. Operation of the system is
subject to the laws and regulations which are applicable in the respective
country at national, federal, European and international level. The generally
accepted rules of technology, usually in the form of standards, directives,
regulations, conditions and technical rules specified by national and federal
organisations as well as trade associations and committees for the field of
specialisation concerned, shall apply. Figures used in this instruction manual
are provided for basic understanding and may differ from the actual design.
The operator/operating company is independently responsible for compliance
with and observance of any subsequently introduced technical innovations or
new legal requirements, as well as for all usual obligations of the
operator/operating company. The original version of this instruction manual
was written in German. All non-German versions of this instruction manual are
translations of the German instruction manual.
2.1.2 Limitation of liability
ads-tec Industrial IT GmbH shall not be liable for personal injury, property
damage or damage caused to the device as well as consequential damage that
is/was the result of non-compliance with this instruction manual, improper use
of the device, repairs and other actions on the device by unqualified
electricians and electricians not certified by ads-tec Industrial IT GmbH, or
that is/was the result of using unapproved replacement parts. Failure to
observe the maintenance intervals shall also result in exclusion from
liability. Furthermore, it is strictly forbidden to make any unauthorised
alterations or technical modifications to the device.
© ads-tec Industrial IT GmbH · Heinrich-Hertz-Str. 1 · 72622 Nürtingen · Germany
MMT8000 series / MMD8000 series
v3.6
9
2.1.3 Manufacturer and contact details
The manufacturer of the product is ads-tec Industrial IT GmbH. The company is referred to in the following as ADS-TEC.
ads-tec Industrial IT GmbH
Heinrich-Hertz-Str.1
72622 Nürtingen
Germany
Phone:
+49 7022 2522-0
Email:
Web:
2.1.4 Relevant device documentation
The following documents are decisive to device setup and operation: ·
Instruction manual: Contains information for installation, commissioning and
operation of the device along with technical data of the device hardware. ·
Website: You can download the instruction manual as well as drivers, software,
user manuals, leaflets and flyers from the Download area of our website www
.ads-tec.com
2.1.5 Symbols
Symbol Meaning Designation of batteries. Batteries may not be disposed of with
household waste, but must rather be disposed of separately. Used batteries
must be returned to the point of sale or a disposal system. Labelling of
electrical and electronic devices. Electrical and electronic devices must not
be disposed of with household waste, but must rather be taken to a collection
point for waste electrical equipment. Such a collection point is generally
operated by public waste management authorities, i.e., by municipalities.
Symbol for the protection earth (PE) connection
Symbol for the functional earth (FE) connection
© ads-tec Industrial IT GmbH · Heinrich-Hertz-Str. 1 · 72622 Nürtingen · Germany
MMT8000 series / MMD8000 series
v3.6
10
2.1.6 Data, figures and modifications
All data, text and figures were prepared to the best of our knowledge. They do
not represent any assurance for the properties themselves. Despite taking
utmost care, no liability can be assumed for accuracy, completeness and
actuality of the information. Subject to changes.
2.1.7 Trademarks
It is noted that any software and/or hardware trademarks and any company brand
names mentioned in this documentation are all subject to the general trademark
protection rights. StoraXe®, Big-LinX® and X-Remote are registered trademarks
of ADS-TEC. All other used third-party trademarks are hereby acknowledged. In
the case of trademark infringement, ADS-TEC reserves the right to exercise all
rights.
2.1.8 Copyright
This instruction manual is protected by copyright. For the authorised user,
simple usage rights are granted within the scope of the intent of the
contract. Any modified use or exploitation of the provided content,
particularly duplication, modification or publishing in whatever form is
permitted only with the prior consent of ADS-TEC. In the case of copyright
infringement, ADS-TEC reserves the right to exercise all rights.
© ads-tec Industrial IT GmbH · Heinrich-Hertz-Str. 1 · 72622 Nürtingen · Germany
MMT8000 series / MMD8000 series
v3.6
11
2.1.9 Standards and conformity
The manufacturer hereby declares that the product described in this
instruction manual complies with all relevant stipulations of the following
European directives:
· 2011/65/EU RoHS Directive · 2014/30/EU EMC Directive · 2014/53/EU RED
Directive · 2014/35/EU Low Voltage Directive The EU conformity declaration can
be requested on our website www.ads-tec.com and downloaded in the Download
area. The product is a class A device (industry). Note: For full compliance
with the EMC legislation, all components and cables used for device connection
must also be compliant with these requirements. It is therefore necessary to
employ BUS and LAN cables with shielded connectors and these must be installed
as per the instructions contained in the instruction manual. Cleanroom
requirements The devices were tested by the Fraunhofer Institute for
Manufacturing Engineering and Automation (IPA) for their suitability for
cleanroom production. The result according to the criteria of the “EU
Guidelines for Good Manufacturing Practice” (GMP) is:
· Suitable for Cleanliness Classes A and B.
This assessment concerns the unit in a resting state. The final assessment
must be made on site in the actual manufacturing process. Devices with UL
certification (Underwriter Laboratories / USA) Variants with a UL symbol on
their label also comply with the following UL standards:
· UL 61010-1 Programmable Controllers · UL 61010-2-201 UL file number E343358
· CAN/CSA-C22.2 No. 61010-1 · CAN/CSA-C22.2 No. 61010-2-201 Devices with SDoC
acc. to FCC regulations (Federal Communications Commission / USA):
· This equipment has been tested and found to comply with the limits for a
Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference when
the equipment is operated in a commercial environment. This equipment
generates, uses, and can radiate radio frequency energy and, if not installed
and used in accordance with the instruction manual, may cause harmful
interference to radio communications. Operation of this equipment in a
residential area is likely to cause harmful interference in which case the
user will be required to correct the interference at his own expense.
© ads-tec Industrial IT GmbH · Heinrich-Hertz-Str. 1 · 72622 Nürtingen · Germany
MMT8000 series / MMD8000 series
v3.6
12
2.2 Explanation of safety instructions
2.2.1 Structure of safety instructions
The signal word classifies the hazard. Reference to the type/consequences and
source of the hazard is made underneath the signal word. Information on how to
avoid the hazard is indicated by an arrow ().
DANGER
Type and source of the hazard! Possible consequences if the hazard is
disregarded Measures for avoiding the hazard
© ads-tec Industrial IT GmbH · Heinrich-Hertz-Str. 1 · 72622 Nürtingen · Germany
MMT8000 series / MMD8000 series
v3.6
13
2.2.2 Explanation of signal words
DANGER
Indicates an imminent danger. If not avoided, death or severe injury will
result.
WARNING
Indicates a possible danger. If not avoided, death or severe injury could
result.
CAUTION
Indicates a possible danger. If not avoided, light or minor injuries could
result.
ATTENTION
Indicates a possibly damaging situation. If not avoided, the system or
something in its surroundings could be damaged.
Recommendation for use: Indicates terms and/or conditions that strictly need to be observed to ensure optimised and/or zero-defect operation. Tips and suggestions for the efficient use of the device and software optimisation are also provided.
© ads-tec Industrial IT GmbH · Heinrich-Hertz-Str. 1 · 72622 Nürtingen · Germany
MMT8000 series / MMD8000 series
v3.6
14
2.3 Safety instructions
2.3.1 Basic safety instructions
· All users must read this manual and have access to it at all times. · The
safety notices and the manual itself must be observed by all persons who work
with this
device. · The manual contains the most important instructions on how to use
this device in a safe way. · Intervention by the user is required only for
performing the actions described in this document.
Should any further modifications be required, it is necessary to consult
either with the manufacturer directly or with service personnel authorised by
the manufacturer. · The device must be de-energised during work. Appropriate
measures must be taken to prevent electrostatic discharges on components. · If
the device is opened up by an unauthorised person, the user may be subject to
hazards and the warranty is invalidated. · Installation, commissioning and
operation may only be performed by qualified and trained personnel. · At the
installation site the valid guidelines and regulations for accident prevention
must be observed. · Appropriate storage, proper transport, installation and
commissioning, as well as careful operation are prerequisites for ensuring
safe and proper operation of the device. · The device can be cleaned using
cleaning agents specified in chapter 9.
2.3.2 Environmental conditions
ATTENTION
Damage caused by heat! If the device is exposed to sunlight or any other light
or heat source, it can overheat and suffer damage. Do not expose the device to
direct radiation by sunlight or any other light or heat source!
© ads-tec Industrial IT GmbH · Heinrich-Hertz-Str. 1 · 72622 Nürtingen · Germany
MMT8000 series / MMD8000 series
v3.6
15
ATTENTION
Damage caused by heat! If the device is installed in a panel, casing or
similar, heat accumulation can occur. Make sure that heat can be dissipated
from the device!
ATTENTION
Damage caused by condensation! If the temperature of the device is different
to that of the room in which it is located, condensation can form. Switch on
the device only if it has acclimated to the ambient temperature!
Use of the device is only permitted · in enclosed buildings · in non-explosive
atmospheres · at altitudes below 2000 m · in environments with maximum
contamination grade 2 (IEC/EN 61131-2)
The device can be operated under the environmental conditions (temperature,
humidity, vibration and shock) which are specified in the data sheet in
chapter 11.1.1. Failure to observe any one of these conditions will invalidate
the warranty of the device. ADS-TEC cannot be held liable for any damages
arising from improper use and handling.
The climatic conditions were tested according to: · IEC/EN 60068-2-1 · IEC/EN
60068-2-2 · IEC/EN 60068-2-14 · Protection class depending on the variant:
IP65 or IP69K according to DIN EN 60529 / ISO 20653
© ads-tec Industrial IT GmbH · Heinrich-Hertz-Str. 1 · 72622 Nürtingen · Germany
MMT8000 series / MMD8000 series
v3.6
16
2.3.3 Intended use
The control system is designed for use in the pharmaceutical, food, beverage
and chemical industries. It was specially developed for the hygiene sector.
The device is used for the visualisation and control of a wide range of
processes on systems and machines in various application environments.
The device is only to be assembled, installed and operated within the
permissible specifications. Use in non-specified environments is prohibited.
2.3.4 Improper use
Operation other than or beyond that described for the device shall be deemed
improper use. The device is not allowed to be used to control vehicles or for
applications for which further approvals beyond the manufacturer’s declaration
are necessary, e.g. applications with explosion hazard, medical technology and
shipping industry. The device must not be put into operation in the case of
transport damage or nonconformity with the specifications and, if necessary,
must be taken out of operation in the case of changing conditions. In the case
of improper use, ADS-TEC shall not accept responsibility or liability for
injury or damage that is directly or indirectly attributable to the handling
of the device.
2.3.5 Damage due to improper use
ATTENTION
Risk of mechanical damage! The device can be damaged as a result of
unauthorised mechanical modifications. Make sure that the device is not
drilled, chiselled or perforated and its exterior shape and design is not
modified in any way!
Should the control system have evident signs of damages caused, e.g., by transport, nonconformity with the specifications, improper operation and storage conditions or due to improper use or handling, the device must be shut down immediately. Ensure that it is secured against being started up accidentally.
© ads-tec Industrial IT GmbH · Heinrich-Hertz-Str. 1 · 72622 Nürtingen · Germany
MMT8000 series / MMD8000 series
v3.6
17
2.3.6 Warranty / repairs
During the device warranty period, any repairs must only be performed by the
manufacturer or by service personnel that has been authorised by the
manufacturer.
2.3.7 Treatment and disposal of lithium batteries
WARNING
Hazard due to explosion Danger of explosion if using incorrect battery types.
Use the battery type recommended by the manufacturer!
ATTENTION
Hazard due to thermal loads The more the battery is exposed to higher
temperatures, the faster it ages. Operate the device within its
specifications!
ATTENTION
Damage to the battery Incorrect handling of the battery can cause it to be
damaged or destroyed Lithium batteries should not be exposed to fire,
soldered, recharged, opened, short-circuited, reversed or heated above 100 °C
and they should be disposed of properly as well as protected against sunlight,
humidity and condensation!
This device contains a lithium battery for supplying the system clock with
power as long as the supply voltage is not connected. The battery has a life
cycle of 3-5 years depending on which load is applied. The battery type to be
used is:
· Lithium battery CR2032 230 mAh · ADS-TEC part number: DZ-SONS-04075-1 The
used lithium battery should be disposed of in accordance with local legal
regulations.
© ads-tec Industrial IT GmbH · Heinrich-Hertz-Str. 1 · 72622 Nürtingen · Germany
MMT8000 series / MMD8000 series
v3.6
18
2.3.8 Electrostatically sensitive components
ATTENTION
Damage due to electrostatically sensitive components Damage to the device can
be caused by electrostatic discharges. All installation and service work
performed on the device must be performed only under safe, secure and de-
energised conditions!
Recommendation for use: Always adhere to the safety measures applicable when handling components at risk of being damaged by electrostatic discharges. The provisions of DIN EN 61340-5-1 / DIN EN 61340-5-2 apply.
© ads-tec Industrial IT GmbH · Heinrich-Hertz-Str. 1 · 72622 Nürtingen · Germany
MMT8000 series / MMD8000 series
v3.6
19
Scope of delivery
ATTENTION
Damage to components containing soft parts! If the soft material is subjected
to a concentrated load, e.g., by placing it on a grating, irreversible
impressions will form after some time. Make sure that a suitable surface is
provided when setting down the device on its display side, e.g. a clean, plane
surface!
Please check that all of the following components are contained in the packaging.
MMT8000 series Device
DVG-MMT8017 or DVG-MMT8024
4-pin plug (power supply)
DZ-SONS-01222-3/A
Instructions for drilling template
DZ-HAND-91053-0/*
Drilling template (for support arm adapter) DZ-MECH-32444-0/*
Installation aid (M3 Allen key)
DZ-MECH-33703-0/*
MMD8000 series Device
DVG-MMD8017 or DVG-MMD8024
3-pole plug
DZ-SONS-00994-2
Instructions for drilling template
DZ-HAND-91053-0/*
Drilling template (for support arm adapter) DZ-MECH-32444-0/*
Installation aid (M3 Allen key)
DZ-MECH-33703-0/*
© ads-tec Industrial IT GmbH · Heinrich-Hertz-Str. 1 · 72622 Nürtingen · Germany
MMT8000 series / MMD8000 series
v3.6
20
3.1 Optional scope of delivery
Operating system (only with MMT)
Key module and additional elements (for non-premounted key module)
Front coversheet for key module Insert strip (silver) Insert strip (black)
DZ-MECH-32391-0/ DZ-MECH-32396-0/ DZ-MECH-32396-1/*
Variants with HDBaseTTM (only with MMD)
Transmitter module Receiver module USB cable HDMI cable
DV-MMDEXT-TX (integrated in the MMD) DZ-SONS-05647-0/ DZ-SONS-05646-0/
Cable for power supply
DZ-SONS-09796-0/*
© ads-tec Industrial IT GmbH · Heinrich-Hertz-Str. 1 · 72622 Nürtingen · Germany
MMT8000 series / MMD8000 series
v3.6
21
Installation
ATTENTION
Damage caused by heat! If the device is exposed to sunlight or any other light
or heat source, it can overheat and suffer damage. Do not expose the device to
direct radiation by sunlight or any other light or heat source!
Recommendation for use: At least 2 persons are required to install the device at the installation location.
Recommendation for use: Before installing, make sure that all mechanical
connections are fixed in place in the connecting tube system at the
installation location.
The following tools are needed for installation: Installation with support arm
adapter
· 4 mm Allen key (1 x straight and 1 x angled) · 2.5 mm Allen key · 3 mm Allen
key · 5 mm Allen key or Torx TX10 · 2 mm flap-tip screwdriver · Wrench
(spanner) 17 mm Installation with VESA 75 adapter · 4 mm Allen key · 5 mm
Allen key or Torx TX10 · 5.5 mm Allen key Installation with adapter for MMD
with IP69K · Spanner 8 mm
© ads-tec Industrial IT GmbH · Heinrich-Hertz-Str. 1 · 72622 Nürtingen · Germany
MMT8000 series / MMD8000 series
v3.6
22
4.1 Inclination angles
Inclination angles at support arm adapter or crosspiece adapter
Figure 7: Inclination angles at support arm adapter or crosspiece adapter
© ads-tec Industrial IT GmbH · Heinrich-Hertz-Str. 1 · 72622 Nürtingen ·
Germany
MMT8000 series / MMD8000 series
v3.6
23
4.2 Overview of installation components
4.2.1 Designations
Figure 8: Designations
1
Device
2
Support arm adapter
3
Wing screw
4
Connecting tube
5
Service slot cover
6
USB flap
7
Service slot
8
Fastening screws
© ads-tec Industrial IT GmbH · Heinrich-Hertz-Str. 1 · 72622 Nürtingen · Germany
MMT8000 series / MMD8000 series
v3.6
24
4.2.2 Service slot MMT
Figure 9: Service slot MMT 8000 series
1
Power supply
2
2 x LAN RJ45
3
1 x 2.5″ SSD mass storage
3.1 Removal aid
3.2 Cover plate with screw fastening
4
2 x USB 3.0
1 x USB 2.0
5
1 x SD-Card Slot
6
2 x FE connection
7
Battery
© ads-tec Industrial IT GmbH · Heinrich-Hertz-Str. 1 · 72622 Nürtingen · Germany
MMT8000 series / MMD8000 series
v3.6
25
4.2.3 Service slot MMD
The new installation-space-optimised variant of the industrial monitors has the following interfaces:
Figure 10: Service slot MMD8000 series
1
Power supply
2
DisplayPort
3
HDMI
4
3 x USB 2.0 type A
5
1 x USB 2.0 type B
6
Optional: HDBaseT extender (RJ45)
7
2 x PE connection
© ads-tec Industrial IT GmbH · Heinrich-Hertz-Str. 1 · 72622 Nürtingen · Germany
MMT8000 series / MMD8000 series
v3.6
26
4.3 Order of installation
Installation with support arm adapter
1. Make sure that the device and all cables are disconnected from the power
supply. 2. Remove the support arm adapter from the device. 3. Optional:
Assemble and install the key module, chap. 4.4.2. 4. Optional: Adjust the
support arm adapter to the installation position you require, chap.4.4.3. 5.
Countersink the connecting tube, chap. 4.4.4. 6. Guide all necessary cables
through the connecting tube and support arm adapter, chap. 4.4.5. 7. Mount the
support arm adapter on the connecting tube (to 6 Nm), chap. 4.4.6. 8.
Optional: Slide the extender kit into the mounting slot and connect the
cables, chap.6. 9. Mount the device on the support arm adapter, chap. 4.4.8.
10. Connect all cables to the interfaces in the service slot, chap. 5. 11.
Connect the device to the power supply (only after all of the above steps have
been
performed).
Installation with VESA 75 adapter
1. Make sure that the device and all cables are disconnected from the power
supply. 2. Screw the VESA adapter to the device. 3. Guide the cables through
the VESA adapter, chap. 4.6. 4. Mount the VESA adapter on your connection
system. 5. Connect all cables to the interfaces in the service slot, chap. 5.
6. Connect the device to the power supply (only after all of the above steps
have been
performed).
© ads-tec Industrial IT GmbH · Heinrich-Hertz-Str. 1 · 72622 Nürtingen · Germany
MMT8000 series / MMD8000 series
v3.6
27
4.4 Installation with support arm adapter
If you do not intend to use a support arm adapter, you can skip chapter 4.4.
4.4.1 Detaching support arm adapter from device
Recommendation for use: If the support arm adapter is already attached to the
device when delivered, remove it. This will make subsequent installation
easier.
Loosen the four threaded pins (A) and remove the two screws (B). Pull the
support arm adapter off the device.
Figure 11: Screw connection of adapter to device
A
4 x M5 x 12 threaded pins (4 mm Allen key)
B
2 x M5 x 16 screws (4 mm Allen key)
© ads-tec Industrial IT GmbH · Heinrich-Hertz-Str. 1 · 72622 Nürtingen · Germany
MMT8000 series / MMD8000 series
v3.6
28
4.4.2 Key module
If you do not intend to use a key module or if your key module has already
been installed by ADSTEC, you can skip chapter 4.4.2.
ATTENTION
Damage to key module Opening the key module incorrectly can cause damage. Open
the key module on the right side (as viewed from the front)!
Switches, buttons and illuminated emergency-stop switches from various switch
ranges can be installed on the key module for a hole diameter of 22.5 mm.
Determine the exact dimensions from the technical drawing. Assemble and
install the key module as described below:
Open the key module on the right side (as viewed from the front) using a wide,
blunt object.
Figure 12: Opening key module Break the prepunched openings out of the key
front as required. You can install up to seven switches/keys.
© ads-tec Industrial IT GmbH · Heinrich-Hertz-Str. 1 · 72622 Nürtingen ·
Germany
MMT8000 series / MMD8000 series
v3.6
29
Punch the required Ø 22.5 mm openings in the front coversheet from behind, or cut them out. The openings are highlighted in Fig. 13.
Figure 13: Prepunched openings in key module Print or write the appropriate
labelling on the insert strip. o The dimensions (given in mm) are shown in
Fig. 14. There are seven printable areas each measuring 6.5 mm in height and
40 mm in length. The gap on the left side is 11 mm and the gaps between the
areas are 8.3 mm.
Figure 14: Labelling strip Slide the labelling strip from behind into the key
front.
Figure 15: Inserting labelling strip Mount your keys on the key front. Install
all necessary cables at the front keys. Guide the cables through the arms of
the mounting bracket.
© ads-tec Industrial IT GmbH · Heinrich-Hertz-Str. 1 · 72622 Nürtingen · Germany
MMT8000 series / MMD8000 series
v3.6
30
Figure 16: Cables of key module Make sure that the key module electronics are
earthed via the device.
Close the key module: Position the front of the key module on the housing so
that the panel lies against the left edge (as viewed from the front). Press
the front of the key module into the housing of the key module. o Make sure
that the front is also properly pressed down at the middle of the housing.
Figure 17: Closing key module
© ads-tec Industrial IT GmbH · Heinrich-Hertz-Str. 1 · 72622 Nürtingen · Germany
MMT8000 series / MMD8000 series
v3.6
31
4.4.3 Adjusting position of support arm adapter
You can install the device both in the support arm position and in the stand position.
Figure 18: Mounting on support arm and stand
If the support arm adapter is not already set to the desired position, adjust
it as required. In order to do this, it is advantageous if the support arm is
not connected to the device.
Loosen the screws marked in the drawing (4 mm Allen key). Remove the screws
and the clamping block from the support arm adapter, e.g. using a
magnetic screwdriver. If the clamping block is jammed, turn in the
installation aid (hexagonal rod with 3 mm grub screw, included in the scope of
delivery).
Figure 19: Screws in support arm adapter and clamping block Grip the T-piece
at one of the black areas and turn the metal tube to the other position. The
support arm position (suspended mounting) is shown on the left and the stand
position (stand mounting) is shown on the right:
Figure 20: Support arm and stand position
© ads-tec Industrial IT GmbH · Heinrich-Hertz-Str. 1 · 72622 Nürtingen ·
Germany
MMT8000 series / MMD8000 series
v3.6
32
Loosely screw the rubberized side of the installation aid (rod with 3 mm
threaded pins at the end) into the clamping block.
Insert the screws into the clamping block. Guide the clamping block into the
support arm adapter.
Figure 21: Inserting screws in adapter
Remove the installation aid. Tighten the screws to a torque of 6.5 Nm (4 mm
Allen key).
© ads-tec Industrial IT GmbH · Heinrich-Hertz-Str. 1 · 72622 Nürtingen · Germany
MMT8000 series / MMD8000 series
v3.6
33
4.4.4 Preparing the connecting tube
WARNING
Risk of injury! If the connecting tube is too thin, the device can work loose
in the support arm position and fall to the ground. Make sure that the
connecting tube meets the specifications!
The connecting tube must have a diameter of 48.3 mm with a maximum tolerance
of +/- 0.3 mm.
Support arm mounting Attach the self-adhesive installation template to the end
of the connecting tube. o The “Display front” marking must be on the side on
which the display will later be. o The arrows must point to the end of the
connecting tube. o Attach the template to the connecting tube as far as the
“Overlap” marking. o Fold over the template at the “Folding edge” marking so
that the end sticks to the back of the “Overlap” area.
Figure 22: Installation template
Countersink the connecting tube at the three marked points (min. M6 drill bit
with 120° drill tip). o Drill max. 2 mm deep.
Figure 23: Countersinking connecting tube (support arm) Remove the template.
© ads-tec Industrial IT GmbH · Heinrich-Hertz-Str. 1 · 72622 Nürtingen ·
Germany
MMT8000 series / MMD8000 series
v3.6
34
Stand mounting Attach the self-adhesive installation template to the end of the connecting tube. o The “Display front” marking must be opposite the side on which the display will later be. o The arrows must point to the end of the connecting tube. o Attach the template to the connecting tube as far as the “Overlap” marking. o Fold over the template at the “Folding edge” marking so that the end sticks to the back of the “Overlap” area.
Figure 24: Installation template
Countersink the connecting tube at the three marked points (min. M6 drill bit
with 120° drill tip). o Drill max. 2 mm deep.
Figure 25: Countersinking connecting tube (stand) Remove the template.
© ads-tec Industrial IT GmbH · Heinrich-Hertz-Str. 1 · 72622 Nürtingen · Germany
MMT8000 series / MMD8000 series
v3.6
35
4.4.5 Cable routing
Recommendation for use: Use cables long enough so that they hang out of the
connecting tube by min. 30 35 cm.
Recommendation for use: Route the cables according to the interface positions
in the service slot.
Support arm mounting Guide all cables out of the connecting tube and through the support arm adapter: o Guide the USB cables through opening A. o Guide the power supply cable, earth cable and LAN cable through opening B.
Figure 26: Cable routing for support arm mounting
Stand mounting Guide all cables out of the connecting tube and through the
support arm adapter: o Guide the USB cables through opening A. o Guide the
power supply cable, earth cable and LAN cable through opening B.
Figure 27: Cable routing for stand mounting
© ads-tec Industrial IT GmbH · Heinrich-Hertz-Str. 1 · 72622 Nürtingen ·
Germany
MMT8000 series / MMD8000 series
v3.6
36
4.4.6 Mounting support arm adapter on connecting tube
WARNING
Risk of injury! If the support arm adapter is attached too loosely, the device
can work loose and fall to the ground. Observe the specified torques!
Support arm mounting: Turn the foot of the support arm adapter so that the
wing screw is opposite the connection openings.
Stand mounting: Turn the foot of the support arm adapter so that the wing
screw is on the same side as the connection openings.
Attach the support arm adapter to the tube. The connection openings must be on
the side to which the display is to point.
Figure 28: Screwing adapter to tube (left: support arm; right: stand mounting)
© ads-tec Industrial IT GmbH · Heinrich-Hertz-Str. 1 · 72622 Nürtingen · Germany
MMT8000 series / MMD8000 series
v3.6
37
Fasten the support arm adapter as follows:
Older version of the fastening elements: 3 x threaded pin with tip ISO4027
M6x5 Allen A2 with PA thread lock: Tighten with 6 Nm (Allen 3 mm).
Newer version of the fastening elements: 3 x threaded pin with tip ISO4027
M6x10 Allen A2 with PA thread lock: Tighten with 5 Nm (Allen 3 mm) The
threaded pins are secured with one of the following: 3 x cap nuts with PA
clamping part DIN986 M6 A2: Tighten with 2.5 Nm 3 x flat nut ISO4035 M6 A2:
Tighten with 2.5 Nm At the end, the nuts must fit evenly against the tube.
Figure 29: Newer version of fastening with threaded pins and nuts
© ads-tec Industrial IT GmbH · Heinrich-Hertz-Str. 1 · 72622 Nürtingen · Germany
MMT8000 series / MMD8000 series
v3.6
38
4.4.7 Detaching and attaching service slot cover
ATTENTION
Risk of dirt and moisture penetration! If the USB flap is not closed
completely, dirt or moisture can enter the device. Close the USB flap
completely before commissioning!
Removing service slot cover Open the USB flap Undo the screw underneath (5 mm Allen key or Torx TX10).
Figure 30: USB flap Remove the service slot cover.
Figure 31: Removing service slot cover
© ads-tec Industrial IT GmbH · Heinrich-Hertz-Str. 1 · 72622 Nürtingen · Germany
MMT8000 series / MMD8000 series
v3.6
39
Attaching service slot cover If required, insert the USB cable on the back of the service slot cover into the USB socket (USB 3.0).
Figure 32: USB cable on service slot cover Position the lower edge of the service slot cover so that the retainer tabs engage in the frame.
Figure 33: Retainer tabs of service slot cover Tighten the mounting screw o
The service slot cover must be completely closed. The two sealing lips of the
service slot cover must no longer be visible. Close the USB flap.
Figure 34: USB flap
© ads-tec Industrial IT GmbH · Heinrich-Hertz-Str. 1 · 72622 Nürtingen ·
Germany
MMT8000 series / MMD8000 series
v3.6
40
4.4.8 Mounting device on support arm adapter
WARNING
Risk of injury! If a person attempts to install the device alone, it may fall
to the ground causing injury and damage. Have a second person assist in
installing the device!
Hold the device in front of the support arm adapter. Guide the cables out of
the support arm adapter and through the service slot openings. Mount the
device on the support arm adapter.
Figure 35: Mounting device on adapter Screw on the device securely using the two screws B and the four threaded pins A.
Figure 36: Screwing device to adapter
A
4 x M5 x 12 threaded pins (4 mm Allen key)
B
2 x M5 x 16 screws (4 mm Allen key)
© ads-tec Industrial IT GmbH · Heinrich-Hertz-Str. 1 · 72622 Nürtingen · Germany
MMT8000 series / MMD8000 series
v3.6
41
4.5 Installation with crosspiece adapter
The crosspiece adapter allows you to mount two devices one above the other.
Figure 37: Installation with crosspiece adapter
Turn the two vertical tube sections of the crosspiece adapter so that the wing
screws point away from the openings.
Countersink the connecting tube with the aid of a drill (see chap. 4.4.4). o
You can attach the adapter to a suspended tube (support arm mounting) or to a
standing tube (stand mounting).
Guide the cables through the adapter.
Figure 38: Crosspiece adapter o The upper side of the crosspiece adapter is
the side with the four protruding metal pins (Fig. 39). o Route the cables
according to the interface positions in the service slot (chap. 4.4.5).
Attach the crosspiece adapter to the connecting tube (chap. 4.4.6). Open the
service slot cover of the device (chap. 0). Secure the device to the
crosspiece adapter (chap. 4.4.8). Connect the cables to the interfaces (chap.
5).
© ads-tec Industrial IT GmbH · Heinrich-Hertz-Str. 1 · 72622 Nürtingen ·
Germany
MMT8000 series / MMD8000 series
v3.6
42
4.6 Installation with VESA 75 adapter
ATTENTION
Penetration of dirt! If you route the cables through openings which do not
match the cable diameters, dirt can enter through the opening. Route the
cables to the openings according to the diameter table given below!
Recommendation for use: Route the cables according to the interface positions
in the service slot.
Screw the VESA adapter to the device. o To do so, secure using the four threaded pins and the two screws (chap. 4.4.8).
Figure 39: Device with VESA adapter Remove the retainer plates (8 screws, 5.5
mm Allen key)
Figure 40: Retainer plates on VESA adapter
© ads-tec Industrial IT GmbH · Heinrich-Hertz-Str. 1 · 72622 Nürtingen ·
Germany
MMT8000 series / MMD8000 series
v3.6
43
Open the service slot cover (chap. 0). Push the rubber inserts upwards out of
the bracket. Pull out the sealing plugs at all cable glands that you require.
o To do so, pull the frame to the side (Fig. 42). o The sealing plugs attached
to the rubber insert must NOT be cut off as they may be
needed for modifications made later.
Figure 41: Rubber insert of VESA adapter
Guide the cables through the openings.
o For each cable, use the opening (S, M or L) which matches the cable diameter.
o Diameter table:
S:
Ø = 2.4 4.0 mm
M: Ø = 4.0 6.0 mm
L:
Ø = 6.0 7.4 mm
Press the rubber inserts into the bracket. Screw on the retainer plates. Screw
the bracket to your VESA connection system.
o Screws M6, length depending on your system, lock washers etc. o Maximum
screw-in depth into the blind rivet nuts: 7 mm.
ATTENTION
Damage due to excessive tightening torque
The device can be damaged if the permitted tightening torque is not observed
when the VESA bracket is screwed on.
Tighten the screws to max. 5 Nm. If necessary: also use a suitable
threadlocker, e.g., low-strength
liquid adhesive.
© ads-tec Industrial IT GmbH · Heinrich-Hertz-Str. 1 · 72622 Nürtingen · Germany
MMT8000 series / MMD8000 series
v3.6
44
4.7 Installation with IP69K adapter
The diagram shows the arrangement of the seals:
Fig. 42: Overview of seals for the variant with IP69K
6 x
Fig. 43: Overview of screws for the variant with IP69K Tools: Spanner 8 mm,
torque: 3.5 Nm
© ads-tec Industrial IT GmbH · Heinrich-Hertz-Str. 1 · 72622 Nürtingen ·
Germany
MMT8000 series / MMD8000 series
v3.6
45
4.8 Installation of the service slot cover IP69K
The graphic shows the fully equipped service slot cover as delivered ex factory:
Fig. 44: Service slot cover IP69K
Remove the 6 screws and seals shown (framed red in Fig. 44) and pull the
service slot cover off the housing.:
Fig. 45: Service slot cover IP69K
© ads-tec Industrial IT GmbH · Heinrich-Hertz-Str. 1 · 72622 Nürtingen ·
Germany
MMT8000 series / MMD8000 series
v3.6
46
Loosen the screws of one or, if necessary, both cloverleaf holders and remove the cloverleaf seals (see Fig. 46). Be careful not to lose the lock washers (circled in red in the picture).
Fig. 46: Service slot cover IP69K
Fig. 47: Service slot cover IP69K
© ads-tec Industrial IT GmbH · Heinrich-Hertz-Str. 1 · 72622 Nürtingen ·
Germany
MMT8000 series / MMD8000 series
v3.6
47
Make all electrical connections and feed the cables through the cloverleaf seal(s) to comply with the IP protection class:
2,5…4 mm2
4…6 mm2 Fig. 48: Service slot cover IP69K
6…8 mm2 (newer version) 4…6 mm2 (older version)
Assembly is done in reverse order of disassembly. Pay particular attention that the lock washers circled in red in Fig. 46 are present. Torque: 3.5 Nm
© ads-tec Industrial IT GmbH · Heinrich-Hertz-Str. 1 · 72622 Nürtingen · Germany
MMT8000 series / MMD8000 series
v3.6
48
Interfaces
WARNING
Hazard due to excessive current! Excessive current can cause overloading of
the electronics which could then result in injury or damage. Operate the
device with a power supply that complies with NEC Class 2.
ATTENTION
Damage to the electronics! The electronics can be damaged if plug-in
connections are connected or disconnected while power is still being applied.
Make sure that no power is being applied while connecting and disconnecting
cables!
© ads-tec Industrial IT GmbH · Heinrich-Hertz-Str. 1 · 72622 Nürtingen · Germany
MMT8000 series / MMD8000 series
v3.6
49
5.1 Interfaces MMT
All device connections are in the service slot. Strain relief fixtures are provided on the support arm adapter.
Figure 49: MMT service slot
1
Power supply
2
2 x LAN RJ45
3
1 x 2.5″ SSD mass storage
3.1 Removal aid
3.2 Cover plate with screw fastening
4
2 x USB 3.0
1 x USB 2.0
5
1 x SD-Card Slot
6
Earth connection
7
Battery
Figure 50: Strain relief fixtures on support arm adapter
© ads-tec Industrial IT GmbH · Heinrich-Hertz-Str. 1 · 72622 Nürtingen ·
Germany
MMT8000 series / MMD8000 series
v3.6
Power supply MMT You will need a power adapter with the following technical data: Voltage: 18…30 V (NEC Class 2) Current depending on the device:
MMT… Processor Max. permanent current (incl. USB) Max. switch-on current Fuse (recommended)
17″ Celeron 3 A
4 A 4 A slow
i5 4 A
4 A 6 A slow
24″ Celeron 3 A
4 A 4 A slow
50
i5 4 A 4 A 6 A slow
For the power supply, use only the 4-pole plug connector included in the scope of delivery.
1
n.c.
2
0 V
3
Earth connection (FE)
4
24 V
(The Fig. shows the socket inside the device)
USB The sockets comply with the USB 2.0 standard (white interface) and the USB
3.0 standard (blue interfaces). The USB 2.0 interfaces are downward compatible
to USB 1.0, and the USB 3.0 interfaces are downward compatible to USB 2.0 and
USB 1.0.
LAN You can integrate the device in an Ethernet network which supports 1
Gbit/s. For this purpose, use the 1Gbit RJ45 LAN ports. If required, the
necessary drivers can be downloaded at www.ads-tec.com. The specifications for
the network topology must be observed.
© ads-tec Industrial IT GmbH · Heinrich-Hertz-Str. 1 · 72622 Nürtingen · Germany
MMT8000 series / MMD8000 series
v3.6
51
Mass storage Hard disk / Flash SSD The following storage options are
available:
1. mSATA module (permanently installed) 2. 2.5″ SSD mass storage with up to
500 GB via SATA (removable, see chapter 8.5.2) External drives External
storage media can be connected via USB interfaces.
ATTENTION
Risk of data loss! Data can be lost if an external data drive is connected or
disconnected during operation. Switch off the device before connecting or
disconnecting an external data drive!
© ads-tec Industrial IT GmbH · Heinrich-Hertz-Str. 1 · 72622 Nürtingen · Germany
MMT8000 series / MMD8000 series
v3.6
52
5.2 Interfaces MMD
The new installation-space-optimised variant of the industrial monitors has the following interfaces:
Figure 51: MMD service slot
1
Power supply
2
DisplayPort
3
HDMI
4
3 x USB 2.0 type A
5
1 x USB 2.0 type B
6
Optional: HDBaseT extender (RJ45)
7
2 x Earth connection
Figure 52: Strain relief fixtures on support arm adapter
© ads-tec Industrial IT GmbH · Heinrich-Hertz-Str. 1 · 72622 Nürtingen ·
Germany
MMT8000 series / MMD8000 series
v3.6
53
Power supply MMD
You will need a power adapter with the following technical data:
Voltage:
18…30 V (NEC Class 2)
Current depending on the device:
MMD… Typical current Max. permanent current Max. switch-on current Fuse (recommended)
17″ (without HDBaseT) 1,2 A 2 A 3 A 4 A slow
24″ (without HDBaseT) 1,2 A 2 A 3 A 4 A slow
For the power supply, use only the 3-pole plug connector included in the scope of delivery.
1
0 V
2
n.c.
3
24 V
(the figure shows the socket in the device)
© ads-tec Industrial IT GmbH · Heinrich-Hertz-Str. 1 · 72622 Nürtingen · Germany
MMT8000 series / MMD8000 series
v3.6
54
5.2.1 Maximum cable lengths
Recommendation for use: Note the maximum cable lengths for the respective application type.
The maximum length of cables which can be used to connect the display and
computer is: · HDMI up to max. 15 m · DisplayPort up to max. 10m · USB 2.0 up
to max. 15 m
For greater distances between the display and computer, you will require the
HDBaseTTM variant of the MMD:
· HDBaseTTM up to max. 100 m
© ads-tec Industrial IT GmbH · Heinrich-Hertz-Str. 1 · 72622 Nürtingen · Germany
MMT8000 series / MMD8000 series
v3.6
55
5.3 Earthing
5.3.1 General informations regarding earthing
Recommendation: The device is operated with extra-low voltage (ELV).
Therefore, the PE connection is optional.
· Protective earth (PE): Personal protection through housing earthing, e.g. to
dissipate static charges. Cable colour: green-yellow.
· Functional earth (FE): For compliance with EMC regulations. Cable colour
must not be greenyellow.
· If both are used, PE and FE should not be brought together directly at the
device, but only in the control cabinet.
· Conductor cross sections: 0V / FE / 24V: AWG 18 ( 1 mm2) or AWG 16 ( 1,5
mm2). With cable length > 5 m, use the larger cross section. PE: AWG16 ( 1.5
mm2), optimum: AWG 10 ( 2.5 mm2)
5.3.2 Earthing MMT
Figure 53: MMT earthing in the service slot
© ads-tec Industrial IT GmbH · Heinrich-Hertz-Str. 1 · 72622 Nürtingen ·
Germany
MMT8000 series / MMD8000 series
v3.6
56
5.3.3 Earthing MMD
The new industrial monitors of the type MMD8017/24 are operated with extra low
voltage (ELV). Nevertheless, a protective earth conductor (PE) should be
connected to the housing.
Figure 54: MMD earthing in the service slot
Please note: The new MMD8017/24 are operated without functional earth (FE).
© ads-tec Industrial IT GmbH · Heinrich-Hertz-Str. 1 · 72622 Nürtingen · Germany
MMT8000 series / MMD8000 series
v3.6
57
5.3.4 Earthing of accessories
The following applies to the earthing of accessories, e.g. the optional key
module:
· The PE connections (if used) of accessories and MMD/MMT may be connected
together in the service slot.
· The FE connections (if required) of various components may not be connected
together in the service slot.
Recommendation: EMC interference on a component that is discharged via FE
should not be coupled to further components, but discharged directly to earth.
Each FE connection must be connected separately to the central earth rail in
the control cabinet.
Figure 55: Example: PE connection of the optional key module
© ads-tec Industrial IT GmbH · Heinrich-Hertz-Str. 1 · 72622 Nürtingen ·
Germany
MMT8000 series / MMD8000 series
v3.6
58
HDBaseTTM variant of the MMD
Receiver
Transmitter
Figure 56: Use of HDBaseTTM variant
With HDBaseTTM, the connection between the computer and monitor is established using a LAN cable with RJ45 plugs. The distances that can be bridged depend on the network infrastructure used:
·
with a CAT6a patch cable without sockets etc.: max. 70 m
·
with a Cat. 7 or 7a LAN installation cable + sockets + two 1 m patch cables: max. 100 m
The receiver module is already integrated in the MMD if the corresponding variant is ordered.
© ads-tec Industrial IT GmbH · Heinrich-Hertz-Str. 1 · 72622 Nürtingen · Germany
MMT8000 series / MMD8000 series
v3.6
59
6.1
Interfaces of transmitter module
The transmitter module is intended for mounting on a top-hat rail (TS35) in the cabinet.
Figure 57: Interfaces of transmitter module
1
24 V
2
HDBaseTTM 100Mbit
3
USB 2.0
4
HDMI
5
SYS LEDs
Connect the receiver module to the transmitter module via the HDBaseTTM
connection.
Recommendation for use: The following CAT cables are recommended for
connecting the transmitter to the receiver module: CAT6a cable 100 m with min.
24AWG / 27AWG
Power supply
You will need a power adapter with the following technical data: Input
voltage: 18 to 30 V (NEC Class 2) Max. switch on current: 0.6 A
For the power supply, use only the supplied 3-pole plug connector.
PIN
Signal
1
24 V
2
FE
3
0 V
The figure shows the socket inside the transmitter module.
© ads-tec Industrial IT GmbH · Heinrich-Hertz-Str. 1 · 72622 Nürtingen · Germany
MMT8000 series / MMD8000 series
v3.6
60
6.2 Status indicators on transmitter module
The transmitter module has LEDs which indicate the status of the transmitter. They provide information about the graphics link (HDCP), the power supply (PWR), the firmware (FW) and the HDBaseTTM connection (HDBT). The table below lists the various states.
Figure 58: Status indicators on transmitter module
HDCP PWR HDBT
FW
LED signal Flashing Off On (blue)
Off On Flashing slowly Flashing rapidly Off Flashing
Off
Action Graphics link is present
No graphics link The device is supplied with voltage via POWER and is ready
for operation No power supply HDBaseTTM link present
Low Power Mode
Ethernet Fallback Mode
No link Firmware is loaded and ready for operation No firmware action
© ads-tec Industrial IT GmbH · Heinrich-Hertz-Str. 1 · 72622 Nürtingen · Germany
MMT8000 series / MMD8000 series
v3.6
61
Commissioning
WARNING
Hazard due to excessive current! Excessive current could result in injury or
damage. Operate the device only with a power supply that complies with NEC
Class 2!
ATTENTION
Hazard due to excessive voltage! The electronics can be damaged if the
permissible voltage is exceeded. Make sure to meet the permissible voltage for
this device!
ATTENTION
Damage to the electronics! The electronics can be damaged if plug-in
connections are connected or disconnected while power is still being applied.
Make sure that no power is being applied while connecting and disconnecting
cables!
ATTENTION
Damage to the electronics! Condensation can damage the device. Switch on the
device only after it has acclimated to the ambient temperature!
Recommendation for use: The shielding of a data cable must always be connected with the connector housing (EMC).
© ads-tec Industrial IT GmbH · Heinrich-Hertz-Str. 1 · 72622 Nürtingen · Germany
MMT8000 series / MMD8000 series
v3.6
62
Recommendation for use:
Insofar as they are specified in the scope of delivery or in the replacement
parts list, only connectors and cables offered by ADS-TEC are to be used for
commissioning and during operation. All other connectors and cables which you
use for commissioning and during operation must have been approved.
Check for operational readiness Make sure that the screw connections between –
the device and support arm adapter – the support arm adapter and connecting
tube are tightened to the specified torques. Make sure that the service slot
and the USB flap are completely closed.
Commissioning device
When connecting and disconnecting cables, make sure that no power is being
applied to the device or cables.
Connect the cables to the interfaces in any order. Secure the cables to the
support arm adapter using the strain relief fixtures. Make sure that the 24 V
power supply complies with NEC Class 2. Connect the device to the power
supply.
© ads-tec Industrial IT GmbH · Heinrich-Hertz-Str. 1 · 72622 Nürtingen · Germany
MMT8000 series / MMD8000 series
v3.6
63
Operation
8.1 Switching on and off
ATTENTION
Damage to the electronics! The electronics can be damaged if the device is
switched off and then on again too quickly. After switching off and before
switching on you must wait for at least 5 seconds!
Switch on the device by connecting it to the external power supply. If an
operating system (Windows or Linux) is installed, it now starts. When the
device is on, the status LED of the monitor lights up. This LED is on the
front at the bottom right.
Switch off the device by shutting down the operating system.
8.2 Multifunction touch-screen
Figure 59: Touch-screen Operate the multifunction touch-screen using up to 10
fingers. It is not only possible to tap elements swiping and dragging
movements are also possible. Recommendation for use: The touch calibration
data is stored independent of the operating system and requires no additional
calibration by the user.
© ads-tec Industrial IT GmbH · Heinrich-Hertz-Str. 1 · 72622 Nürtingen ·
Germany
MMT8000 series / MMD8000 series
v3.6
64
The necessary driver software is already integrated in the respective operating system. If you need other drivers, you can download them at http://www.ads-tec.com in the Download area.
Recommendation for use: With older operating systems, a driver may be required for the touch-screen functionality.
8.3 Turning/tilting device and key module
Tilting the device Stand behind the device. On the left side, unscrew the end
cap provided with finger recesses approx. 3 turns. Adjust the tilt of the
device. Screw down the end again.
Figure 60: Tilting the device Recommendation for use: Make sure that the
fastening screw of the support arm adapter is screwed out far enough so that
the device moves smoothly. If rattling noises are heard when turning the
device, unscrew the end further.
© ads-tec Industrial IT GmbH · Heinrich-Hertz-Str. 1 · 72622 Nürtingen ·
Germany
MMT8000 series / MMD8000 series
v3.6
65
Tilting the key module
1. Stand behind the device. 2. Unscrew completely the end cap without finger
recesses on the right side of the support arm
adapter. 3. Loosen the spacer sleeve with a suitable tool (width across flats:
17 mm). 4. Adjust the angle of the key module. 5. Tighten the spacer sleeve
again. 6. Screw down the end cap again.
Figure 61: Tilting the key module
Turning the device Undo the wing screw. Turn the device (it can be turned
through max. 340°). Tighten the wing screw again.
Figure 62: Turning the device
8.4 WiFi and Bluetooth
If available, these optional functions can be used with the means of the
installed operating system.
© ads-tec Industrial IT GmbH · Heinrich-Hertz-Str. 1 · 72622 Nürtingen ·
Germany
MMT8000 series / MMD8000 series
v3.6
66
8.5 Component replacement
ATTENTION
Risk of short circuit! A short circuit can occur if components are replaced
while the device is still switched on. Before replacing components, disconnect
the power supply from the device!
8.5.1 Replacing BIOS battery on MMT
ATTENTION
Risk of explosion! Hazard due to overheating of the battery Make sure that the
battery is of the correct type and that it is inserted with the correct
polarity!
Recommendation for use: Avoid touching both battery poles at the same time.
The device of the MMT8000 series contains a lithium battery for supplying the
system clock with power as long as the supply voltage is not connected. The
battery has a life cycle of 3-5 years depending on which load is applied. It
is in the service slot. The battery type to be used is: · Lithium battery type
CR2032 (230 mAh / 3 V)
Recommendation for use: Use only the battery type recommended by ADS-TEC.
© ads-tec Industrial IT GmbH · Heinrich-Hertz-Str. 1 · 72622 Nürtingen · Germany
MMT8000 series / MMD8000 series
v3.6
67
Replacing battery
Pull out the battery drawer (pull both sides of the battery drawer at the same time).
Remove the old battery. Press the new battery (1) into the drawer (2);
the battery must engage in the drawer. o The positive and negative terminal is
indicated on the battery holder.
Turn the drawer (3) over so that the negative terminal is pointing upwards.
Insert the drawer into its slot (4); the drawer must engage in the slot.
1
2
3
© ads-tec Industrial IT GmbH · Heinrich-Hertz-Str. 1 · 72622 Nürtingen · Germany
MMT8000 series / MMD8000 series
v3.6
68
8.5.2 Replacing mass storage device
On the MMT8000 series, there may be a mass storage device in the service slot.
Removing mass storage device
Remove the cover plate. o To do so, undo the fastening screw (PH1 cross-tip screwdriver).
Grip the mass storage device by its removal aid (white flap) and pull it carefully and parallel along its guides into the slot.
Remove the mass storage device at an angle in an upward direction.
© ads-tec Industrial IT GmbH · Heinrich-Hertz-Str. 1 · 72622 Nürtingen · Germany
MMT8000 series / MMD8000 series
v3.6
69
Installing mass storage device
Insert the mass storage device into the slot at an angle.
Lower the mass storage device and push it in all the way parallel to its
guides.
Insert the retainer tabs of the cover into the guide slots and close the
cover.
Screw in the fastening screw fingertight (PH1 cross-tip screwdriver)
© ads-tec Industrial IT GmbH · Heinrich-Hertz-Str. 1 · 72622 Nürtingen · Germany
MMT8000 series / MMD8000 series
v3.6
70
8.5.3 Replacement parts list
Insofar as they are specified in the scope of delivery or in the replacement
parts list, only connectors and cables offered by ADS-TEC are to be used for
commissioning and during operation. All other connectors and cables which you
use for commissioning and during operation must have been approved.
The following components can be ordered as replacement parts from ADS-TEC:
Device/designation
Designation
MMT
Plug 4-pole plug with locking lever, green
BIOS battery Lithium battery CR2032 230mAh
Part number
DZ-SONS-01222-3/A DZ-SONS-04075-1
MMD
Plug 3-pole plug, green
DZ-SONS-00994-2
HDBaseT transmitter Cable USB2.0 1 m Cable HDMI Male-Male 1 m Cable HDMI Male- DP Male 1 m Plug 3-pole plug, black
DZ-SONS-05642-x DZ-SONS-05643-x DZ-SONS-05644-x DZ-SONS-01212-x
© ads-tec Industrial IT GmbH · Heinrich-Hertz-Str. 1 · 72622 Nürtingen · Germany
MMT8000 series / MMD8000 series
v3.6
71
Maintenance, cleaning and disposal
Maintenance and cleaning must be performed by appropriately qualified personnel.
9.1 Maintenance
The following maintenance intervals must be observed:
Interval Daily
Monthly
3 years Optional, if installed Daily
Location Overall device Fixing screws BIOS battery
Emergency stop button
Activity Visually inspect for loose objects and visible damage Check that they
are seated securely; tighten as necessary Change
Check that it functions correctly
9.2 Cleaning
How often you need to clean the system depends on your work and the operating
environment. If necessary, follow the on-site cleaning plan.
Clean and maintain your system regularly.
9.2.1 Devices with protection class IP69K
Units with protection class IP69K have been extensively tested for cleaning
under high pressure. For material-friendly and hygienic cleaning, we recommend
the use of foam cleaner and subsequent rinsing of the units. The MMT/MMD
series has been tested for a variety of cleaning agents, see chapter 9.3.
© ads-tec Industrial IT GmbH · Heinrich-Hertz-Str. 1 · 72622 Nürtingen · Germany
MMT8000 series / MMD8000 series
v3.6
72
9.3 Cleaning agents and disinfectants
We recommend cleaning the devices using commercially available glass cleaning
agents. The following cleaning agents have also been successfully tested:
Ethanol and isopropanol based:
· Deconex Solarsept · Bacillol · Meliseptol
Neutral cleaning agents: · P3-Cosa Foam 40 · P3-Cosa PUR 80
Acidic cleaning agents: · P3-cosa CIP 72
Alkaline cleaning agents · P-cosa CIP 92
Quarternary ammonium compounds: · Klerdice-CR Biocide A · Deconex Surface AF
Disinfectants: · Hydrogen peroxide 3 % (Recommendation: Wipe off the product
completely after use, otherwise water stains may form.)
9.4 Disposal
Electrical and electronic devices must not be disposed of with household
waste, but must rather be taken to a collection point for waste electrical
equipment. Such a collection point is generally operated by public waste
management authorities, i.e., by municipalities.
© ads-tec Industrial IT GmbH · Heinrich-Hertz-Str. 1 · 72622 Nürtingen · Germany
MMT8000 series / MMD8000 series
v3.6
73
Nomenclature of ADS-TEC products and accessories
10.1 Main articles
A typical ADS-TEC article number is DVG-MMT8017 123-AB.
Many ADS-TEC article numbers for main products follow this logic:
· Starting letters until -
: DV hardware product without software DVG
hardware product with software DVK kit; a combination of several products.
Single products are normally also sold as DV or DVG. Mainly used for
customized bundles in large contracts.
· Three letters after -
: describe product category, e.g. MMD Machine
Mounted Display MMT Machine Mounted Terminal OPD Operating Panel Display
OPC Operating Panel Computer
· First two digits: series, e.g. series 8000 is 80. · Following two digits:
size of screen, e.g. 17 for 17 inch and 24 for 24 inch. · Three digits after
the blank: 123 or xxx is a continuous number between 001 and 999 and defines
the system configuration. · Last two letters: AB or yy are two varying letters
depending on the operating system.
© ads-tec Industrial IT GmbH · Heinrich-Hertz-Str. 1 · 72622 Nürtingen · Germany
MMT8000 series / MMD8000 series
v3.6
74
10.2 Accessory articles
10.2.1 Display and USB transmission
For distances up to 100m, a HDBaseTTM kit is available. It is named DVK-
MMDEXT-KIT xxx-yy and contains two components:
· a receiver DV-MMDEXT-RX xxx-yy
· a transmitter DV-MMDEXT-TX xxx-yy
For distances less than 15m, HDMI and USB cables are available as an option.
Their article numbers are e.g. DV-MMXOPT-04 xxx-yy.
Analogous to this, spare parts and additional small components are all named
DV-MMXOPT-zz xxxyy.
© ads-tec Industrial IT GmbH · Heinrich-Hertz-Str. 1 · 72622 Nürtingen · Germany
MMT8000 series / MMD8000 series
v3.6
75
10.2.2 Support arm adapter
DVG-MMD80zz xxx-yy and DVG-MMT80zz xxx-yy can be mounted using the support arm
adapter DV-MMXADAPT xxx-yy. Several versions of DV-MMXADAPT xxx-yy are
available, the differences are indicated by xxx-yy. Examples for this are:
Front foils and keys can be customized, if this is done at ADS-TEC, this
changes xxx-yy in the article number. Details are described in chapter 4.4.2.
10.2.3 Product kits
Combinations of several products are called kits and denoted by DVK in the
article number. The single products are normally also sold as DV or DVG. This
is mainly used for customized bundles in large contracts or for typical
combinations that are useful for many customers.
Examples:
· DVK-MMDEXT-KIT xxx-yy contains a receiver DV-MMDEXT-RX xxx-yy and a
transmitter DV-MMDEXT-TX xxx-yy.
· DVK-MMD8017 xxx.yy contains DVG-MMD8017 xxx.yy DV-MMDEXT-RX xxx-yy DV-
MMDEXT-TX xxx-yy DV-MMXADAPT xxx-y
· Likewise, DVK-MMD8024, DVK-MMT8017, DVK-MMT8024, DVK-OPD8017 and DVK-OPD8024
are available.
© ads-tec Industrial IT GmbH · Heinrich-Hertz-Str. 1 · 72622 Nürtingen ·
Germany
MMT8000 series / MMD8000 series
v3.6
76
Technical data
11.1 MMT/MMD technical data
11.1.1 Data sheet
Housing Display Resolution
Touch
Processor
MMT8017
MMT8024
MMD8017
MMD8024
Fully enclosed stainless steel housing
17.3″ LED backlight 23.8″ LED backlight 17.3″ LED backlight 1920 x 1080 pixels 1920 x 1080 pixels 1920 x 1080 pixels
23.8″ LED backlight 1920 x 1080 pixels
PCAP multi-touch / toughened glass
Intel® CeleronTM 1.6 GHz (2980U) or
–
Intel® CoreTM i5 1.9 GHz (4300U)
RAM
to 8 GB DDR3
–
Mass storage *)
SSD to 500 GB or
–
mSATA SSD to 128 GB
Network
2 x 1 Gbit/s Ethernet RJ45
–
Wireless (optional)
WLAN: IEEE 802.11ac/a/b/g/n
–
Bluetooth V4.2, V4.0 LE, V3.0+HS,
V2.1+EDR
Interfaces
1 x USB 2.0/2 x USB 3.0 (1 x accessible from outside, optional)
3 x USB 2.0 (1 x accessible from outside, optional)
1 x USB slave
1 x HDMI, 1 x DisplayPort
Power adapter
18 30 V NEC Class 2
Operating system
Windows 10 IoT (64 Bit)
–
Protection class
Depending on variant IP65 or IP69K (not verified by UL, tested by ADS-TEC)
Operating temperature 0 °C to +50 °C
0 °C to +45 °C
0 °C to +50 °C
0 °C to +45 °C
Storage temperature
-20 °C to +70 °C
Dimensions (WxHxD) **) 431 x 261 x 68 mm
-20 °C to +60 °C 578 x 347 x 67 mm
-20 °C to +70 °C 431 x 261 x 68 mm
-20 °C to +60 °C 578 x 347 x 67 mm
Weight
Vibration Shock resistance
Approx. 5 kg
(without key module)
Approx. 7.5 kg
Approx. 5 kg
Approx. 7.5 kg
(without key module) (without key module) (without key module)
10 m/s2; 2 200 Hz (class 3M4 of standard IEC/EN 60721-3-3)
100 m/s2; t=11 ms (class 3M4 of standard IEC/EN 60721-3-3)
Humidity
10 to 85% non-condensing
*) Due to e.g. additionally implemented security functions of the SSD manufacturer, the freely available capacity of the mass storage may be slightly reduced.
**) Without support arm and key module.
© ads-tec Industrial IT GmbH · Heinrich-Hertz-Str. 1 · 72622 Nürtingen · Germany
MMT8000 series / MMD8000 series
v3.6
77
11.1.2 External device dimensions MMT8017
Figure 63: External device dimensions MMT8017
© ads-tec Industrial IT GmbH · Heinrich-Hertz-Str. 1 · 72622 Nürtingen ·
Germany
MMT8000 series / MMD8000 series
v3.6
78
11.1.3 External device dimensions MMT8024
Figure 64: External device dimensions MMT8024
© ads-tec Industrial IT GmbH · Heinrich-Hertz-Str. 1 · 72622 Nürtingen ·
Germany
MMT8000 series / MMD8000 series
v3.6
79
11.1.4 External device dimensions MMD8017
Figure 65: External device dimensions MMD8017
© ads-tec Industrial IT GmbH · Heinrich-Hertz-Str. 1 · 72622 Nürtingen ·
Germany
MMT8000 series / MMD8000 series
v3.6
80
11.1.5 External device dimensions MMD8024
Figure 66: External device dimensions MMD8024
© ads-tec Industrial IT GmbH · Heinrich-Hertz-Str. 1 · 72622 Nürtingen ·
Germany
MMT8000 series / MMD8000 series
v3.6
81
11.1.6 External dimensions MMD with IP69K
The dimensions of these monitors correspond to those of the standard versions,
only the installation depth differs.
For the variant with service slot cover (right), the installation depth
essentially depends on the design of the customer’s VESA mount.
Fig. 67: External dimensions MMD with IP69K
© ads-tec Industrial IT GmbH · Heinrich-Hertz-Str. 1 · 72622 Nürtingen ·
Germany
MMT8000 series / MMD8000 series
v3.6
82
11.2 HDBaseTTM technical data
11.2.1 Data sheet
Housing Interfaces
Power supply Protection class Operating temperature Dimensions (W x H x D)
Weight Humidity
Transmitter Tx Aluminium die-casting housing 1 x USB 2.0 1 x HDMI 1 x HDBaseTTM 100Mbit 18 30 V NEC Class 2 IP 20 0° to 55°C 140 x 159 x 35 mm 0.7 kg 10…85 %, non condensing
© ads-tec Industrial IT GmbH · Heinrich-Hertz-Str. 1 · 72622 Nürtingen · Germany
MMT8000 series / MMD8000 series
v3.6
83
11.2.2 External dimensions HDBaseTTM transmitter
Figure 68: External device dimensions HDBaseTTM transmitter
© ads-tec Industrial IT GmbH · Heinrich-Hertz-Str. 1 · 72622 Nürtingen ·
Germany
MMT8000 series / MMD8000 series
v3.6
84
List of figures
Figure 1: Use of MMT and MMD ………………………………………………………………………………………………. 5 Figure 2: Mounting on support arm and stand ……………………………………………………………………………. 6 Figure 3: Crosspiece adapter …………………………………………………………………………………………………… 6 Figure 4: Turning and tilting……………………………………………………………………………………………………… 7 Figure 5: VESA adapter…………………………………………………………………………………………………………… 7 Figure 6: Variants with IP69K …………………………………………………………………………………………………… 7 Figure 7: Inclination angles at support arm adapter or crosspiece adapter …………………………………… 22 Figure 8: Designations…………………………………………………………………………………………………………… 23 Figure 9: Service slot MMT 8000 series ………………………………………………………………………………… 24 Figure 10: Service slot MMD8000 series ………………………………………………………………………………. 25 Figure 11: Screw connection of adapter to device …………………………………………………………………….. 27 Figure 12: Opening key module ……………………………………………………………………………………………… 28 Figure 13: Prepunched openings in key module ……………………………………………………………………….. 29 Figure 14: Labelling strip ……………………………………………………………………………………………………….. 29 Figure 15: Inserting labelling strip …………………………………………………………………………………………… 29 Figure 16: Cables of key module…………………………………………………………………………………………….. 30 Figure 17: Closing key module ……………………………………………………………………………………………….. 30 Figure 18: Mounting on support arm and stand ………………………………………………………………………… 31 Figure 19: Screws in support arm adapter and clamping block …………………………………………………… 31 Figure 20: Support arm and stand position ………………………………………………………………………………. 31 Figure 21: Inserting screws in adapter …………………………………………………………………………………….. 32 Figure 22: Installation template ………………………………………………………………………………………………. 33 Figure 23: Countersinking connecting tube (support arm) ………………………………………………………….. 33 Figure 24: Installation template ………………………………………………………………………………………………. 34 Figure 25: Countersinking connecting tube (stand) …………………………………………………………………… 34 Figure 26: Cable routing for support arm mounting …………………………………………………………………… 35 Figure 27: Cable routing for stand mounting …………………………………………………………………………….. 35 Figure 28: Screwing adapter to tube (left: support arm; right: stand mounting) ……………………………… 36 Figure 29: Newer version of fastening with threaded pins and nuts …………………………………………….. 37 Figure 30: USB flap ………………………………………………………………………………………………………………. 38 Figure 31: Removing service slot cover …………………………………………………………………………………… 38 Figure 32: USB cable on service slot cover ……………………………………………………………………………… 39 Figure 33: Retainer tabs of service slot cover …………………………………………………………………………… 39 Figure 34: USB flap ………………………………………………………………………………………………………………. 39 Figure 35: Mounting device on adapter ……………………………………………………………………………………. 40 Figure 36: Screwing device to adapter …………………………………………………………………………………….. 40 Figure 37: Installation with crosspiece adapter …………………………………………………………………………. 41 Figure 38: Crosspiece adapter ……………………………………………………………………………………………….. 41 Figure 39: Device with VESA adapter ……………………………………………………………………………………… 42 Figure 40: Retainer plates on VESA adapter ……………………………………………………………………………. 42
© ads-tec Industrial IT GmbH · Heinrich-Hertz-Str. 1 · 72622 Nürtingen · Germany
MMT8000 series / MMD8000 series
v3.6
85
Figure 41: Rubber insert of VESA adapter ……………………………………………………………………………….. 43 Fig. 42: Overview of seals for the variant with IP69K…………………………………………………………………. 44 Fig. 43: Overview of screws for the variant with IP69K ………………………………………………………………. 44 Fig. 44: Service slot cover IP69K ……………………………………………………………………………………………. 45 Fig. 45: Service slot cover IP69K ……………………………………………………………………………………………. 45 Fig. 46: Service slot cover IP69K ……………………………………………………………………………………………. 46 Fig. 47: Service slot cover IP69K ……………………………………………………………………………………………. 46 Fig. 48: Service slot cover IP69K ……………………………………………………………………………………………. 47 Figure 49: MMT service slot …………………………………………………………………………………………………… 49 Figure 50: Strain relief fixtures on support arm adapter ……………………………………………………………… 49 Figure 51: MMD service slot…………………………………………………………………………………………………… 52 Figure 52: Strain relief fixtures on support arm adapter ……………………………………………………………… 52 Figure 53: MMT earthing in the service slot ……………………………………………………………………………… 55 Figure 54: MMD earthing in the service slot……………………………………………………………………………… 56 Figure 55: Example: PE connection of the optional key module………………………………………………….. 57 Figure 56: Use of HDBaseTTM variant ……………………………………………………………………………………… 58 Figure 57: Interfaces of transmitter module………………………………………………………………………………. 59 Figure 58: Status indicators on transmitter module……………………………………………………………………. 60 Figure 59: Touch-screen ……………………………………………………………………………………………………….. 63 Figure 60: Tilting the device …………………………………………………………………………………………………… 64 Figure 61: Tilting the key module ……………………………………………………………………………………………. 65 Figure 62: Turning the device…………………………………………………………………………………………………. 65 Figure 63: External device dimensions MMT8017 …………………………………………………………………….. 77 Figure 64: External device dimensions MMT8024 …………………………………………………………………….. 78 Figure 65: External device dimensions MMD8017…………………………………………………………………….. 79 Figure 66: External device dimensions MMD8024…………………………………………………………………….. 80 Fig. 67: External dimensions MMD with IP69K …………………………………………………………………………. 81 Figure 68: External device dimensions HDBaseTTM transmitter ……………………………………………….. 83
© ads-tec Industrial IT GmbH · Heinrich-Hertz-Str. 1 · 72622 Nürtingen · Germany
MMT8000 series / MMD8000 series
v3.6
86
Service & support
ADS-TEC and its partner companies offer you comprehensive maintenance and
support services, ensuring quick and competent support should you have any
questions or concerns with regard to ADS-TEC products and equipment.
Because ADS-TEC products are also used by partner companies, these devices may
have customised configurations. Should any questions arise with regard to such
specific configurations and software installations, please contact the system
supplier in question as ads-tec will not be able to answer such questions.
ADS-TEC does not provide support services for any device that was not
purchased directly from ADSTEC. In this case, maintenance and support is
provided by the partner company.
13.1 ADS-TEC support
The ADS-TEC support team is available for inquiries from direct customers
between 8:30am and 5:00pm, Monday to Friday and can be reached via phone, fax
or e-mail: Phone: +49 7022 2522-202 Email: support.iit@ads-tec.de
Alternatively, you can contact us by completing a support form on our website
www.ads-tec.com. Our Support team will then get in touch with you as soon as
possible.
© ads-tec Industrial IT GmbH · Heinrich-Hertz-Str. 1 · 72622 Nürtingen · Germany
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>