DEHUMIDIFIER
Owner’s Manual
MODEL: DDR050BLPBDB-ME
DDR050BLPBDB-ME 50 Pint Dehumidifier with Pump
Welcome to the Danby family.
We are proud of our quality products and we believe in dependable service. We
suggest that you read this owner’s manual before plugging in your new
appliance as it contains important operation information, safety information,
troubleshooting, and maintenance tips to ensure the reliability and longevity
of your appliance.
You are entitled to the warranty coverage as described in the owner’s manual
provided with your new appliance.
- Please write down your appliance information below. You must keep the original proof of purchase receipt to validate and receive warranty services.
- Register your product online and receive a FREE 2 MONTH WARRANTY EXTENSION after filling out a product survey, at www.danby.com/support/product-registration/
Model Number: ____
Serial Number: ____
Date of Purchase: __
Need Help?
- Read your Owner’s Manual for installation help, troubleshooting, and maintenance assistance.
- Visit www.Danby.com to access self-service tools, FAQs and much more by searching your model number in the search bar.
- For the Quickest Customer Service, please fill out the web form at www.danby.com/support. Your submission will go directly to an expert on your particular appliance. Our average response times are between 20 minutes and 2 hours, during EST business hours.
- Call 1-800-263-2629 – please note that during peak hours, hold times can exceed one hour.
Important Safety Information
READ AND FOLLOW ALL SAFETY INSTRUCTIONS
SAFETY REQUIREMENTS
This appliance is not intended for use by persons (including children) whose
physical, sensory or mental capabilities may be different or reduced, or who
lack experience or knowledge, unless such persons receive supervision or
training to operate the appliance by a person responsible for their safety.
Children should be supervised to ensure that they do not play with the
appliance.
To avoid risk of electric shock, do not operate this dehumidifier in an area
that is likely to accumulate standing water. If this condition develops,
disconnect the power supply before stepping into the water.
Do not store or use combustible materials such as gasoline or other fl ammable
vapors or liquids in the vicinity of this or any other appliance.
Do not insert fingers or other objects into grills or openings in the
appliance.
Do not cover or block the intake and exhaust openings.
Do not operate the appliance without the fi lter installed.
Do not operate the appliance near heat sources.
This appliance is intended for indoor, residential applications only. Do not
use this dehumidifier outdoors. Do not use this dehumidifier for commercial or
industrial applications.
GROUNDING INSTRUCTIONS
This appliance must be grounded. Grounding reduces the risk of electrical
shock by providing an escape wire for the electrical current.
This appliance has a cord that has a grounding wire with a 3-prong plug. The
power cord must be plugged into an outlet that is properly grounded.
If the outlet is a 2-prong wall outlet, it must be replaced with a properly
grounded 3-prong wall outlet. The serial rating plate indicates the voltage
and frequency the appliance is designed for.
WARNING – Improper use of the grounding plug can result in a risk of
electric shock.
Consult a qualified electrician or service agent if the grounding instructions
are not completely understood, or if doubt exists as to whether the appliance
is properly grounded.
Do not connect the appliance to extension cords, adapters or together with
another appliance in the same wall outlet.
Do not splice the power cord. Do not under any circumstances cut or remove the
third ground prong from the power cord.
If the power supply cord is damaged, it must be replaced by the manufacturer,
its service agent or similar qualified person in order to avoid hazard.
SAVE THESE INSTRUCTIONS!
OPERATING INSTRUCTIONS
FEATURES
- Control panel
- Handles (both sides)
- Water bucket
- Water level indicator
- Air outlet
- Air fi lter
- Continuous drain outlet
- Power cord storage strap
- Power cord storage band
- Power cord
- Pump drain outlet
LOCATION
- Place the dehumidifier on a smooth, level floor that is strong enough to support the appliance with a full bucket of water.
- Do not place the dehumidifier on carpeting as this can block air fl ow around the appliance. Do not force casters to move over carpeting as the appliance can become unbalanced and spill water.
- To maintain efficiency, operate the appliance in an enclosed area. Keep nearby doors and windows closed.
- Maintain a minimum clearance of 40 cm (16 inches) around the air outlets and 20 cm (8 inches) on other sides of the appliance to allow for proper air circulation.
CONTROL PANEL
- Auto defrost light: The light will illuminate when frost builds up on the evaporator coils. The compressor will cycle off and the fan will continue to run until the frost melts.
- Bucket full light: The light will illuminate when the bucket is full or incorrectly positioned inside the cabinet. The compressor and fan operation will stop as a safety feature. When the bucket is emptied or correctly re-positioned the dehumidifier will resume operation automatically.
- Display: Shows the actual (± 5% accuracy) room humidity level in a range of 30% to 90%. Otherwise, displays selection when programming humidity or timer.
- Pump button: Press to activate the drain pump. Ensure that a drain hose is connected before starting the pump.
- Smart dehumidify: This function will automatically adjust the humidity level with the fluctuating room temperatures. The humidity level cannot be adjusted in this setting, it will stabilize between 45% – 55%. Press the humidity adjust buttons to cancel this feature.
- Filter button: The check fi lter light will fl ash after 250 hours of operation. After cleaning the fi lter, press the fi lter button to turn off the light. Press and hold the fi lter button for 3 seconds to activate the wireless feature.
- Continuous button: Press to activate the continuous dehumidifying operation.
- Fan button: Press to select normal or high fan speed. The light will illuminate when set to high fan speed.
- Timer button: Press to set the timer.
- Humidity adjust buttons: The humidity level can be set within a range of 35% to 85% relative humidity in 5% increments. For drier air, set to a lower percentage value. For more damp air, set a higher percentage value.
- Power button: Press to turn the dehumidifier on or off.
OPERATION
- The recommended ambient operating temperature is between 5°C (41°F) and 32°C (90°F).
- Any time the appliance is placed on its back or side, it must be allowed to stand upright for 6 hours before plugging in to avoid damage to internal components.
- The default setting is 40% and high fan speed. Depending on conditions the dehumidifier may not start automatically under the default setting. This means the ambient humidity is less than 40%. Press the humidity adjust buttons to lower the set humidity until the it is lower than the ambient humidity.
- For optimal performance, ensure that the humidity setting is 10% lower than the ambient humidity. It is normal for the ambient humidity to vary up to 5% above or below the set humidity.
- It is recommended in normal conditions to set the humidity between 40-45%.
- It is normal for the dehumidifier to exhaust warm air from the air outlet.
- The power cord storage band can be found in the water bucket and it can be installed by pressing it onto the back of the cabinet until it clicks.
WIRELESS CONNECTION
This appliance can be controlled with a wireless application on your wireless
device.
Visit https://www.danby.com/support/apps
to download the application and learn about its operation.
TIMER
Auto Off
- When the dehumidifier is turned on, press the timer button to activate the auto off timer.
- Press the humidity adjust buttons to change the set time in 0.5 hour increments up to 10 hours and then in 1 hour increments up to 24 hours.
Auto On
- When the dehumidifier is turned off, press the timer button to activate the auto on timer.
- Press the humidity adjust buttons to change the set time in 0.5 hour increments up to 10 hours and then in 1 hour increments up to 24 hours.
Using Auto On and Auto Off Together
The auto on and auto off timers can be used at the same time by first setting
one and then the other.
For example, if the dehumidifier is running, you can set the auto off timer to
let it run for a set amount of time before turning off and then set the auto
on timer to turn it back on at a later time.
Or, if the dehumidifier is not running, you can set the auto on timer to turn
it on at a later time and then set the auto off timer to shut it off after
running for a period of time.
Note: The timer will not cycle the dehumidifier on and off indefinitely.
The auto on and auto off timers will function one time and then the
dehumidifier will return to regular functioning.
Turning the dehumidifier on or off at any time or changing the timer setting to
0.0 will cancel the timer settings.
WATER REMOVAL
There are three ways to remove collected water from the appliance.
-
Water Bucket
The dehumidifier will automatically collect condensed water in the water bucket. When the bucket is full, the compressor and fan will turn off and the full bucket indicator light will turn on. The display will show “P2”.
To empty the bucket, gently remove it from the appliance by gripping both sides and pulling outward. Be cautious when removing the bucket, it will be full and can be heavy.
Do not place the water bucket directly on the floor.
The bottom of the bucket is uneven and it will fall over and spill water.
Empty the bucket and replace it in the appliance.
The dehumidifier will not function without the bucket installed.
Never tamper with or attempt to defeat the water level fl oat system. Proper installation of the water
bucket is crucial in maintaining reliable operation.
Note: When removing the bucket, the pump arm for the drain pump may fall down. It must be gently pushed upward back into the correct position before replacing the bucket. -
Continuous Drain
Water can be removed using the continuous drain with a standard garden hose and female threaded end (not provided).
Before using any automatic drain functions, check that all drain ports are clean. There is one drain port inside the bucket compartment of the appliance, remove the bucket to see it. There is one drain port on the back of the appliance where the female threaded end and garden hose attach. All drain ports should be cleaned with a pipe cleaner prior to use.
To use the continuous drain you must purchase a garden hose and female threaded end.
The required dimensions are:
• Female threaded end: ID:M=1’’
• Garden hose: ID≥Φ5/16’’
Remove the cover from the continuous drain outlet and attach the female threaded end and the garden hose to the back of the appliance. Direct the other end of the garden hose to a bucket or floor drain.
Ensure that the garden hose is not bent and goes straight down from the back of the appliance. The continuous drain is only activated by gravity so any bends or upward motion in the hose will stop the water from draining.
The garden hose should be cut so that it is no more than 1.8 m (6 feet) long. If the drain hose is too long water may not drain completely which can lead to stagnant water and mildew build up inside the hose.
Notes:
• Do not clean the drain ports with anything more rigid than a pipe cleaner as this can damage the appliance.
• If the drain ports are clogged or dirty it can cause water to leak from the bottom of the appliance.
• The continuous drain is fed by gravity alone. -
Pump Drain
If the continuous drain is inconvenient, water can be removed from the appliance using the pump drain.
When using the pump, the appliance will first fill the bucket with water and then the pump arm will pump water from the bucket through the drain and out the hose.
Note that the pump will not completely empty the bucket, it will only remove approximately 20% of the water from the bucket. Water will remain in the bucket as the pump operates.
When using the pump drain, the water bucket should be emptied every few days to ensure that the water in the bucket does not become stagnant or grow mildew Remove the continuous drain hose from the unit and rotate the black plastic cover to the continuous drain hose outlet clockwise.
Peel off the fixed tape, insert the pump drain hose into the pump drain hose outlet for depth of 15 mm at least or until it clicks and make sure the hose is secure so there are no leaks.
Direct the other end of the hose to a drain. Press the pump button to activate the pump function. When the bucket is full, the pump will begin to work.
Ensure that the drain hose is not bent, this can stop the water from draining correctly and overwork the pump.
Do not connect the provided hose together with another hose. The maximum length of the pump drain hose should be no more than 4.6 m (15 feet). If the drain hose is too long water may not drain completely which can lead to stagnant water and mildew build up inside the hose.
To remove the hose, press inward on the ring around the drain and pull the hose outward.
Important: If the drain pump is activated, water will exit the drain whether a hose is attached or not.
Ensure that the drain pump is deactivated when the hose is removed to avoid damage to floor due to leaking water.
CARE & MAINTENANCE
AIR FILTER
The air fi lter should be cleaned approximately every 2 weeks. The air fi lter
may require more frequent cleaning if there is significant dander or fur in the
air.
Approximately every two weeks, the fi lter indicator light on the control panel
will illuminate as a reminder to clean the fi lter. Follow the steps below to
clean the fi lter and return the appliance to normal functioning.
- The air fi lter is located behind the rear intake grill. To remove the air fi lter, grasp the fi lter tab on the bottom of the grill and slide it downward.
- Use a vacuum cleaner with a soft brush attachment to remove any large debris or dust build up from the air fi lter.
- Wash the fi lter in lukewarm, soapy water, below 40°C (104°F), or use a neutral cleaning agent.
- Rinse the fi lter with clean water and dry thoroughly before reinstalling in the appliance.
- Press the fi lter button on the control panel to resume normal functioning.
Note: Do not operate the appliance without the air fi lter installed.
ERROR CODES
If the display panel shows any of the below error codes, unplug the appliance,
let it stand for 5-10 minutes and then plug it back in. If the error persists,
call for service.
AS – Humidity sensor error
ES – Temperature sensor error
P2 – Full bucket
Eb – bucket removed or not in correct position
CLEANING
To avoid possible electric shock, ensure that the appliance is unplugged
before performing any cleaning or maintenance.
The outside of the appliance can be wiped clean with a soft cloth or with a
lukewarm, damp cloth if necessary.
Do not use gasoline, benzene, thinner or any other chemicals to clean this
appliance as these substances can cause damage to the finish and deformation of
plastic parts.
Never pour water directly onto the appliance as this will cause deterioration
of electrical components and wiring insulation.
Ensure that the drain ports on the interior of the appliance and the drain
ports on the back of the appliance are free of dirt and calcium build up.
END OF SEASON CARE
Unplug the dehumidifier and ensure the fi lter is clean. Ensure the bucket is
empty and then allow both the bucket and the dehumidifier to dry completely
before storing for the off season. It could take a few days for water inside
the dehumidifier to completely evaporate. You can speed up this process by
wiping the bucket with a dry cloth and ensuring the lower drain of the
dehumidifier has been emptied. Store the dehumidifier covered in a dry location.
DISPOSAL
This appliance may not be treated as regular household waste, it should be
taken to the appropriate waste collection point for recycling of electrical
components. Check for local regulatory compliance regarding approved and safe
disposal of this appliance.
FREQUENTLY ASKED QUESTIONS
What is the best humidity setting?
We recommend setting your dehumidifier between 40-45%.
Is the air that comes out of the dehumidifier supposed to be hot?
Yes, usually this air feels warm.
Why isn’t the dehumidifier collecting any water?
There may not be enough humidity in your environment or the relative humidity might be set higher than ambient humidity.
Does the fan run continuously?
In continuous mode, the fan will run continuously. In smart dehumidify mode or manual mode the fan will cycle on and off.
Can I use an extension cord?
No, the dehumidifier is built to operate using the power cord provided.
Does the timer cycle on and off forever?
The on and off timers can be used at the same time however, they will only cycle one time and then resume normal functioning.
How do I hook up my direct drain?
To use the continuous drain you must purchase a garden hose and female threaded end. The dimensions required are: • female threaded end: ID:M=1’’ • garden hose: ID≥Φ5/16’’. Remove the cover from the continuous drain outlet and attach the female threaded end and the garden hose to the back of the appliance. Direct the other end of the garden hose to a bucket or floor drain.
Does the filter light come on when it is dirty?
The filter light comes on automatically after about 250 hours of use even if the filter is clean. Clean the filter and then press the filter button to turn the filter light off.
What is the plastic piece in the bucket?
This rounded piece is called a buckle and is clipped on to the back of the dehumidifier. It is used to wrap the power cord during long term storage of the dehumidifier.
TROUBLESHOOTING
Appliance will not operate
- Plug is not fully inserted into the wall outlet
- Blown fuse or circuit breaker
- Ambient humidity is lower than the set humidity
- Bucket is full or is not in the proper position
Insufficient dehumidifying
- Air fi lter is dirty
- Blocked air flow
- Appliance size is too small for application
- Ambient humidity is lower than the set humidity
Noise
- Air fi lter is dirty
- Bucket is not in proper position
- Floor surface is not level
Odors
- Formation of mold or mildew on internal wet surfaces
- Place an algaecide tablet in the water bucket
Water on floor
- Hose connection is loose
- Drain cover has been removed
Frost build up
- When ambient temperature is below 5°C (41°F) frost may form
- Switch the appliance to fan only mode until the frost melts
FCC WIRELESS REQUIREMENTS
This equipment has been tested and found to comply with the limits for a Class
B digital device, pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a
particular installation.
If this equipment does cause harmful interference to radio or television
reception, which can be determined by turning the equipment off and on, the
user is encouraged to try to correct the interference by one or more of the
following measures:
- Reorient or relocate the receiving antenna
- Increase the separation between the equipment and receiver
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected
- Consult the dealer or an experienced radio/TV technician for help
Changes or modifications not approved by the party responsible for FCC and
Industry Canada compliance could void the user’s authority to operate the
equipment. This appliance complies with Part 15 of the FCC Rules and license-
exempt RSS standards.
Operation is subject to the following conditions:
- This device may not cause interference.
- This device must accept any interference received, including interference that may cause undesired operation.
This equipment complies with FCC RF and IC RSS-102 radiation exposure limits
set forth for an uncontrolled environment. This equipment should be installed
and operated with minimum distance 20cm(8 inches) between the radiator and
your body.
This device complies with RSS-247 of Industry Canada. Operation is subject to
the condition that this device does not cause harmful interference.
This device contains:
FCC ID: 2ADQOMDNA21
IC: 12575A-MDNA21
LIMITED “CARRY IN” WARRANTY
This quality product is warranted to be free from manufacturer’s defects in
material and workmanship, provided that the unit is used under the normal
operating conditions intended by the manufacturer.
This warranty is available only to the person to whom the unit was originally
sold by Danby Products Limited [Canada] or Danby Products Inc. (U.S.A.)
(hereafter “Danby”) or by an authorized distributor of Danby, and is non-
transferable.
TERMS OF WARRANTY
Plastic parts are warranted for thirty (30) days from the date of purchase,
with no extensions provided.
First 24 months During the first twenty four (24) months, any functional parts
of this product found to be defective, will be repaired or replaced, at
warrantor’s option, at no charge to the original purchaser.
To obtain service Contact the dealer where the unit was purchased, or contact
the nearest authorized Danby service depot, where service must be performed by
a qualified service technician. If service is performed on the unit by anyone
other than an authorized service depot, all obligations of Danby under this
warranty shall be void.
It is the responsibility of the purchaser to transport the appliance to the
nearest authorized service depot.
Transportation charges to and from the service location are not protected by
this warranty and are the responsibility of the purchaser.
Nothing within this warranty shall imply that Danby will be responsible or
liable for any spoilage or damage to food or other
contents of this appliance, whether due to any defect of the appliance, or its
use, whether proper or improper.
EXCLUSIONS
Save as herein provided, by Danby, there are no other warranties, conditions,
representations or guarantees, express or implied, made or intended by Danby
or its authorized distributors and all other warranties, conditions,
representations or guarantees, including any warranties, conditions,
representations or guarantees under any Sale of Goods Act or like legislation
or statute is hereby expressly excluded. Save as herein provided, Danby shall
not be responsible for any damages for persons or property, including the unit
itself, howsoever caused or any consequential damages arising tromp the
malfunction of the unit and by the purchase of the unit, the purchaser does
hereby agree to indemnify and hold harmless Danby from any claim for damages
to persons or property caused by
the unit.
GENERAL PROVISIONS
No warranty or insurance herein contained or set out shall apply when damage
or repair is caused by any of the following: :
- Power failure.
- Damage in transit or when moving the appliance. :
- Improper power supply such as low voltage, defective house wiring or inadequate fuses.
- Accident, alteration, abuse or misuse of the appliance such as inadequate air circulation in the room or abnormal operating , conditions (ie. extremely high or low room temperature}.
- Use for commercial or industrial purposes (ie. If the appliance is not installed in a domestic residence). )
- Fire, water damage, theft, war, riot, hostility, acts of God such as hurricanes, floods etc.
- Service calls resulting in customer education. ,
- Improper Installation {ie. Building-in of a free standing appliance or using an appliance outdoors that is not approved for outdoor application, including but not limited to: garages, patios, porches or anywhere that is not properly insulated or climate controlled).
Proof of purchase date will be required for warranty claims; retain bills of sale. In the event that warranty service is required, present the root of purchase for our authorized service depot.
Warranty Service
Carry In
Danby Products Limited
PO Box 1778, Guelph, Ontario, Canada N1H 6Z9
Telephone: 519-837-0920
FAX: 519-837-0449
1-800-263-2629
04/09
Danby Products Inc.
PO Box 669, Findlay, Ohio, U.S.A. 45840
Telephone: 419-425-8627
FAX: 419-425-8629
*Trademark of Danby Products
Danby Products Limited, Guelph, Ontario, Canada N1H 6Z9
Danby Products Inc. Findlay, Ohio, U.S.A. 45840
www.Danby.com 2023.01.16
Printed in China