AO Smith TJVHP-250A Heat Pump Storage Tank Instruction Manual

June 12, 2024
AO Smith

AO Smith TJVHP-250A Heat Pump Storage Tank

AO-Smith-TJVHP-250A-Heat-Pump-Storage-Tank-PRO

These A. O. Smith heat pump storage tanks are optimized for heat pump DHW applications requiring long duration recovery periods.

Product Information

The A. O. Smith heat pump storage tanks are designed for commercial heat pump DHW applications that require long duration recovery periods. These tanks are optimized for efficient heat pump operation and come with several features to ensure optimal performance.

  • Four models available: TJVHP-250A, TJVHP-500A, TJVHP-750A, TJVHP-1000A
  • Anode protection to prevent corrosion
  • Heavy gauge steel jacket for durability
  • Threaded openings for easy installation
  • ASME tank construction for safety
  • 10-year warranty for peace of mind

Usage Instructions

To use the A. O. Smith heat pump storage tank:

  1. Select the appropriate model based on your desired storage capacity. The available models are TJVHP-250A (250 gallons), TJVHP-500A (450 gallons), TJVHP-750A (650 gallons), and TJVHP-1000A (850 gallons).
  2. Ensure that the tank is installed in a suitable location, following any local building codes and regulations.
  3. Connect the tank to your heat pump DHW system using the provided threaded openings.
  4. Make sure that the tank has proper anode protection to prevent corrosion.
  5. Verify that the tank is constructed with a heavy gauge steel jacket for durability.
  6. Check that the tank has a working pressure of 125 PSI.
  7. Inspect the glass-lined interior of the tank, which is fired to 1600°F for a molecular fusing of glass and steel.
  8. Ensure that the tank is fully insulated with a minimum of 5 inches thick, high-density polyurethane foam insulation, providing an insulating value of R30.
  9. Monitor the jacket dimensions, which can be found in the product specifications, to ensure proper fit and installation.
  10. Refer to the warranty information provided for any questions or concerns regarding the warranty coverage.
  11. For additional technical information or assistance, contact A.O. Smith Corporation at 800-527-1953.

Note: A.O. Smith Corporation reserves the right to make product changes or improvements without prior notice.

FEATURES

Heat pump DHW production often relies on minimal input and full utilization of off-peak periods to heat the stored water. These tanks are designed to take full advantage of these systems by reducing turbulence and providing unprecedented stratification. The proprietary stratification system employs a unique baffle that arrests water velocity into and out of the tank to prevent disruption of the stratified layers. An impressive R30 insulation value helps retain heat until it is demanded by the system. Draw down of 95% sets these tanks apart from others, delivering more hot water from a given capacity.

  • FOUR MODELS

    • 250-gallons (model TJVHP-250A)
    • 450-gallons (model TJVHP-500A)
    • 650-gallons (model TJVHP-750A)
    • 850-gallons (model TJVHP-1000A)
  • GLASS-LINED TANK
    Alkaline borosilicate composition permanently fused to steel by firing at a temperature of 1600°F, providing years of corrosion protection and dependable use

  • ANODE PROTECTION
    Furnished with magnesium anodes for additional anti-corrosion protection

  • HEAVY GAUGE STEEL JACKET
    The jacket is constructed from heavy gauge galvanized steel, primed and painted on both sides

  • THREADED OPENINGS
    Furnished with two 3” bolted flange circulating connections, one 1-1/4” NPT relief valve connection, four 3/4” NPT aquastat openings and one 1” NPT drain connection

  • INSULATION
    Completely encased in a minimum of 5” thick, high density polyurethane foam insulation and have an insulating value of R30, exceeding the minimum thermal insulation requirements of the U. S. Department of Energy and current edition of ASHRAE/IESNA 90.1

  • ASME TANK CONSTRUCTION

    • Constructed in accordance with ASME Boiler and Pressure Vessel Code requirements, and “HLW” stamped and registered with the National Board of Boiler and Pressure Vessel Inspectors
    • 125 PSI ASME standard working pressure
  • 10 YEAR WARRANTY
    If the tank should leak any time during the first 10 years, under the terms of the warranty, A. O. Smith will repair or replace the tank. Installation, labor, handling and local delivery are extra. For complete information, consult the written warranty.

DIMENSION

AO-Smith-TJVHP-250A-Heat-Pump-Storage-Tank-1

SPECIFICATION

Model Number

|

Rated Storage Capacity (Gallons)

|

A

|

B

|

C

|

D

|

Shipping Weight

---|---|---|---|---|---|---
TJVHP-250A| 250| 99-1/2”| 40”| 19-1/2”| 95”| 1,180
TJVHP-500A| 450| 100”| 52”| 23”| 95-1/2”| 1,726
TJVHP-750A| 650| 136”| 52”| 23”| 131-1/2”| 2,911
TJVHP-1000A| 850| 137”| 58”| 25”| 132-1/2”| 3,458

SUGGESTED SPECIFICATION

  • Storage tank shall be A. O. Smith tank, Model ____ with vertical construction having a storage capacity of _____ gallons. The tank shall be constructed with an inner chamber baffle designed to receive all circulation to and from the water heater to eliminate turbulence in the tank. The baffled tank shall supply 95% of tank capacity without a drop in outlet temperature, regardless of rate of draw.
  • Storage tank shall be constructed in accordance with ASME Boiler and Pressure Vessel Code requirements, and “HLW” stamped and registered with the National Board of Boiler and Pressure Vessel Inspectors. The tank shall be furnished with the following connections: two 3” bolted flange circulating connections, one 1-1/4” NPT relief valve connection, four 3/4” NPT aquastat openings and one 1” NPT drain connection. The tank shall be furnished with a man-way for ease of inspection, clean-out and service.
  • Storage tank shall have a working pressure of 125 PSI. The interior of the storage tank shall be glass-lined and fired to 1600o F to ensure a molecular fusing of glass and steel. Storage tank shall be furnished with magnesium anodes. Storage tank shall have a ten (10) year limited warranty as outlined in the written warranty.
  • The storage tank shall be constructed with a heavy gauge galvanized steel jacket assembly, primed and painted on both sides with a minimum dry film thickness of 0.70 mills. The storage tank shall be completely encased in a minimum of 5” thick, high density polyurethane foam insulation and have an insulating value of R30.
  • The jacket dimensions shall be ” wide, ” deep and ____” high.

For Technical Information call 800-527-1953. A.O. Smith Corporation reserves the right to make product changes or improvements without prior notice.

© June 2021 A. O. Smith Corporation. All Rights Reserved
www.hotwater.com | 800-527-1953 Toll-Free USA | A. O. Smith Corporation | 500 Tennessee Waltz Parkway | Ashland City, TN 37015

http://waterheatertimer.org/Two-water-heaters.html

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals