UEi HUB2 Refrigeration Analyzer Kit Instruction Manual
- June 12, 2024
- UEi
Table of Contents
HUB2 / HUB4 / HUB6
INSTRUCTION MANUAL
HUB2 Refrigeration Analyzer Kit
1-800-547-5740
www.ueitest.com • email:
info@ueitest.com
HUB2
2 WHP1
4 Batteries (AAA)
Carrying case| HUB4
2 WPP1
2 WPC1
4 Batteries (AA)
Carrying case| HUB6
2 WHP1
2 WPP1
2 WPC1
8 Batteries (4x AA, 4x AAA) Carrying case
---|---|---
IMPORTANT SAFETY WARNINGS
WARNING
Read entire safety notes section regarding potential hazard and proper
instructions before using these probes. In this manual the word “WARNING” is
used to indicate conditions or actions that may pose physical hazards to the
user. The word “CAUTION” is used to indicate conditions or actions that may
damage these instrument.
WARNING
To ensure safe operation and service of these probes, follow these
instructions.
Failure to observe these warnings can result in severe injury or death.
WARNING
Maximum over pressure is: 1000 PSI.
WARNING
- Do not open these probes to replace batteries while the probes are connected to an HVACR or other mechanical system.
- To avoid false readings, replace batteries if a low battery indicator appears.
- Do not use this these probes if they appear damaged.
- Always adhere to national and local safety codes. Use proper personal protective equipment (PPE).
WARNING
These probes are designed for trade professionals who are familiar with the
hazards of their trade. Observe all recommended safety procedures that include
proper lockout utilization and use of personal protective equipment that
includes safety glasses, gloves and flame resistant clothing.
WHP1 OVERVIEW
1. Hygrometer (WHP1): Hub 2 & Hub 6
A. Lock Button: Press to open or close probe
B. 1/4” diameter probe.
C. Magnetic Mount
D. Battery Cover.
E. Light: Blinks GREEN when probe is powered on. Blinks RED when low battery.*
CAUTION: Press down Lock Button to release probe. Failure to do so may
break probe and is not covered under warranty.
GENERAL SPECIFICATIONS
Temperature Range: 32˚F to 140˚F (0˚C to 60˚C)
Temperature Accuracy: ±0.5˚F (0.3˚C)
Relative Humidity Range: 0% to 100%
Relative Humidity Resolution: 0.1%
Relative Humidity Accuracy: ±3% 20% to 80%
otherwise ±5%
Operating Temperature: 41°F to 140°F (5°C to 60°C)
Storage Temperature: 14°F to 140°F (-10°C to 60°C)
Operating Humidity: 20% RH to 80% RH
Recommended: Do Not use longer than 60 hours out of range
Dimensions: 6.84 in x 1.93 in x 1.53 in (17.4 cm x 4.9 cm x 3.9 cm)
Item Weight: 4.4 oz (125 gr)
Certification: CE Conformity, FCC/IC
Battery Type: (AAA) 2
Battery Life: 100+ hours
- NOTE: Low battery indicator is also in the “Tool Connection” screen Battery level are displayed in the tool connection screen to the right of each probe connected.
Caution: Take care not to lose the screws when opening battery compartments
- Remove battery cover.
- Replace the old batteries with 2 new (AAA) batteries.
- Replace the battery cover.
WPP1 OVERVIEW
2. Pressure Probe (WPP1): Hub 4 & Hub 6
A. Cable connector plug-in: for connecting the pipe clamp sensor (WPC1).
B. Battery cover
C. Light: Blinks GREEN when probe is powered on and blinks RED when low
battery.*
D. Power Button: Hold for one second to power on
E. 1/4”pressure connector
F. 1/4” pass-through *connector NOTE:** Low battery indicator is in the
“Tool Connection” screen
GENERAL SPECIFICATIONS
Range: 0 to 725 PSIg
Resolution: 0.1 PSI
Accuracy: 0.5% F.S. (at 25˚C ±3˚C) Total 1% F.S. 32˚F to 158˚F (0˚C to 70˚C)
Operating Temperature: 14°F to 158°F (-10°C to 70°C)
Storage Temperature: 14°F to 140°F (-10°C to 60°C)
Operating Humidity: 30% RH to 85% RH
Over-range: 1000 PSI
Dimensions: 6.70 in x 1.56 in x 1.44 in (17 cm x 4 cm x 3.7 cm)
Item Weight: 7.4 oz (210 gr)
Certification: CE Conformity, FCC/IC
Battery Type: (AA) 2
Battery Life: 100+ hours
Battery level are displayed in the tool connection screen to the right of each probe connected.
Caution: Take care not to lose the screws when opening battery compartments
- Remove battery cover.
- Replace the old batteries with 2 new (AA) batteries.
- Replace the battery cover.
WPC1 OVERVIEW
3. Pipe clamp sensor (WPC1): Hub 4 & Hub 6
A. Temperature sensor
B. Cable connector plug-in: for connecting WPC1 to the WPP1.
NOTE: Maximum pipe diameter is 1.5 in. (3.8cm) GENERAL SPECIFICATIONS
Range: 32˚F to 176˚F (0˚C to 80˚C)
Resolution: 0.1˚F
Accuracy: ±(0.6˚F (0.3˚C))
Response Time: <30 sec.
Operating Temperature: -40°F to 185°F (-40°C to 85°C)
Storage Temperature: 14°F to 140°F (-10°C to 60°C)
Dimensions: 5.66 in x 3.81 in x 1.10 in (14.4 cm x 9.7 cm x 2.8 cm)
Item Weight: 2.1 oz (60 gr)
Certification: CE Conformity, FCC/IC
UEi HUB OVERVIEW
A. Suction Line Pressure
B. Suction Line Temperature
C. Refrigerant Favorites (tap to view)
D. Liquid Line Pressure
E. Liquid Line Temperature| F. Refrigerant List (tap to view)
G. Air Side Screen (tap or swipe left to view)
H. Vapor Saturation Temperature
I. Liquid Saturation Temperature
---|---
A. Refrigerant Side Screen (tap or swipe right to view)
B. Delta T
C. Target Delta T (assumes 400 CFM/ton)
D. Return Dry Bulb Temperature| E. Return Wet Bulb Temperature
F. Return and Supply Calculations (tap to view)
G. Supply Dry Bulb Temperature
H. Supply Wet Bulb Temperature
---|---
R11
R113
R114
R115
R116
R12
R123
R133ZD
R1234YF
R1324ZE
R124
R125
R13
R134A
R142B
R143A
R152A
R22
R227EA
R23
R236FA
R245FA
R290
R32
R401A
R401B
R401C
R402A
R402B
R403A
R403B| R404A
R405A
R406A
R407A
R407B
R407C
R407E
R407F
R407H
R408A
R409A
R409B
R410A
R410B
R411A
R411B
R412A
R413A
R414A
R414B
(Hotshot)
R416A
R417A
R417C
(Hotshot 2)
R418A
R419A
R420A
R421A
R421B
R422A| R422B
(NU22B)
R422C
(One shot)
R422D
R423A
R424A
R425A
R426A
R427A
R428A
R429A
R430A
R431A
R432A
R433A
R434A
(RS-45)
R435A
R436A
R436B
R438A
(MU99)
R444A
R444B
R448A
R449A
R450A
R452A
R452B
R453A| R454A
R454B
R454C
R455A
R458A
R500
R501
R502
R503
R504
R507A
R508A
R508B
(Suva95)
R509A
R510A
R512A
R513A
R600
(Butane)
R600A
(Isobutane)
R601
(Pentane)
R601A
(Isobu-tane)
---|---|---|---
Refrigerant Favorites Button: displays selected favorites for quick changes.
Tap to select or enter units
A. Pressure Units
B. Temperature Units
C. Enthalpy Units
D. Elevation
E. Units
A. Tool Assigned
B. Forget Tool
C. Tool found but not assigned
D. Battery Level
E. Signal Strength
F. Refresh nearby tools
A. Contacts
B. Manual (English, Spanish and French)
C. Find a distributor@UEitest.com
D. Tap to view Features + Benefits Video
FCC/IC INFORMATION
FCC and IC STATEMENT
This equipment has been tested and found to comply with the limits for a Class
B digital device, pursuant to part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and
on, the user is encouraged to try to correct the interference by one or more
of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
This equipment complies with FCC/IC RSS102 radiation exposure limits set forth
for an uncontrolled environment.
This device complies with Industry Canada license-exempt RSS standard(s).
Operation is subject to the following two conditions: (1) this device may not
cause interference, and (2) this device must accept any interference,
including interference that may cause undesired operation of the device.
Under Industry Canada regulations, this radio transmitter may only operate
using an antenna of a type and maximum (or lesser) gain approved for the
transmitter by Industry Canada. To reduce potential radio interference to
other users, the antenna type and its gain should be so chosen that the
equivalent isotropically radiated power (e.i.r.p.) is not more than that
necessary for successful communication.
FCC AND IC NOTICE
This device complies with Part 15 of the FCC rules and Industry Canada license
exempt RSS 247. Operation is subject to the following two conditions: (1) This
device may not cause harmful interference; and (2) this device must accept any
interference received, including interference that may cause undesired
operation.
FCC CAUTION
The device must not be co-located or operated in conjunction with any other
antenna or transmitter.
Caution the user that changes or modifications not expressly approved by the
party responsible for compliance could void the user’s authority to operate
the equipment.
a. The device should be installed and operated with a minimum distance of 20cm
between the radiator and your body.
b. This device complies with RSS247 of Industry Canada. This device complies
with Industry Canada license-exempt RSS standard(s). Operation is subject to
the following two conditions: (1) this device may not cause interference, and
(2) this device must accept any interference, including interference that may
cause undesired operation of the device.
This Class B digital apparatus complies with Canadian ICES-003.
DISPOSAL
Caution: This symbol indicates that equipment and its accessories shall be subject to separate collection and correct disposal.
CLEANING
Periodically clean your probe using a damp cloth. DO NOT use abrasive, flammable liquids, cleaning solvents, or strong detergents as they may damage the finish, impair safety, or affect the reliability of the structural components.
STORAGE
Remove the batteries when instrument is not in use for a prolonged period of time. Do not expose to high temperatures or humidity. After a period of storage in extreme conditions exceeding the limits mentioned in the General Specifications section, allow the instrument to return to normal operating conditions before using it.
WARRANTY
The HUB is warranted to be free from defects in materials and workmanship for
a period of 1 year from the date of purchase. If within the warranty period
your instrument should become inoperative from such defects, the unit will be
repaired or replaced at UEi’s option. This warranty covers normal use and does
not cover damage which occurs in shipment or failure which results from
alteration, tampering, accident, misuse, abuse, neglect or improper
maintenance. Batteries and consequential damage resulting from failed
batteries are not covered by warranty.
Any implied warranties, including but not limited to implied warranties of
merchantability and fitness for a particular purpose, are limited to the
express warranty. UEi shall not be liable for loss of use of the instrument or
other incidental or consequential damages, expenses, or economic loss, or for
any claim or claims for such damage, expenses or economic loss.
Warranty only covers hardware and does not extend to software applications.
A purchase receipt or other proof of original purchase date will be required
before warranty repairs will be rendered. Instruments out of warranty will be
repaired (when repairable) for a service charge
For more information on warranty and service, contact:
www.ueitest.com Email:
info@ueitest.com
1-800-547-5740
This warranty gives you specific legal rights. You may also have other rights,
which vary from state to state.
Copyright © 2023 Kane USA Inc. All Rights Reserved. 17500 03/23